Skip to content

Machine status

The Machine Status unit contains the pages that show what the machine is doing: the current welding cycle or just completed, alarms and the production history.

Pages in the unit:

  • CONTROL PAGE: progress of the current cycle and results of the last cycle;
  • Alarm monitor: active alarms and alarm history;
  • Production report: history of cycles performed;
  • Statistical process control: only if this option is enabled on the machine.

Tapping the unit on the Home page opens a pop-up showing, on the left, the icon, name and description of the unit and, on the right, the list of pages; these same pages are also in the side menu.

Appearance: green square icon with an i.

Machine Status unit pop-up

Position: on the Home page, first group in the top row.

CONTROL PAGE

The CONTROL PAGE displays the progress of the current welding cycle and the results of the last completed cycle. This is the page that the operator keeps open during production in automatic cycle mode.

The page is divided into three areas:

  • top row of cards: from the left, Welding time, Welding depth, Cycle time, Vibration frequency (on machines with vibration only) and Welding result; for users with access to the Welding Parameters page, the Welding Parameters button also appears on the far right;
  • central area: when the machine is in manual mode, it displays the active mode (the green hand labelled Manual); in automatic mode, it displays the cycle stages and, from the start of heating or welding, the cycle graph;
  • bottom row: on the left, the Production batch (or Vacuum cycle, when active); on the right, the Good parts and Scrap pieces counters.

CONTROL PAGE

Position: Machine status > CONTROL PAGE menu.

Welding time

The Welding Time card displays the duration of the weld in the last completed cycle, in seconds (s), to two decimal places.

The value is updated in real time during welding and is finalised at the end of the welding phase. It remains visible until the next cycle, when it is reset to zero upon clamping of the workpieces, immediately after start-up.

The meaning of the value depends on the machine’s technology: see the related entries.

Appearance: a tab with the title Welding time, a grey clock icon with a tick mark, and the value in white digits followed by s.

Welding time

Position: Machine status > CONTROL PAGE page, top row of cards, first card on the left.

Welding time – IR and HP

On infrared (IR) and hot plate (HP) machines, the welding time is the duration of the stages during which the workpieces, after being heated, are joined under pressure. It does not include cooling under pressure or the switching time; if the first joining stage is disabled, the time is zero. The heating duration and switching time can be viewed separately by tapping the Welding Depth tab.

Welding depth

The Weld Depth tab shows how far the workpieces have sunk into one another during welding, in millimetres (mm), to three decimal places.

Depth refers to the movement of the workpieces towards one another due to the melting of the material, measured from the start of melting to the end of welding. The value is updated in real time during welding and cooling, then remains at the final value of the last welding cycle until the start of the next welding. The position from which the calculation begins depends on the technology: see the related entries.

The meaning of the value depends on the machine’s technology: see the related entries.

Appearance: tab with the title Welding depth, a grey icon of a square with a downward-pointing arrow, and the value in white digits followed by mm.

Welding depth

Position: Machine Status > CONTROL PAGE page, top row of cards, second card from the left.

Welding depth – IR

On infrared machines, depth depends on the heating phase (time spent in front of the mirror, distance of the parts from the mirror and heating power) and on the force applied whilst joining the parts. If the cycle includes piece taking, the reference position for calculating depth is acquired during this phase.

Tapping the card opens the Heating / Depth pop-up, which displays:

  • Table and Head: the depth measured separately on the table and on the head, in mm;
  • Time: the duration of the heating phase, in s;
  • Switchover time: the time between the end of the heating phase and the joining of the parts, in seconds;
  • the graph showing the depth of the table and head over time; the light blue eye-shaped icon beneath each axis shows or hides the corresponding curve.

To close the pop-up, tap the down arrow.

On infrared (IR) machines, the depth is the sum of the table and head plunges, measured from the workpiece gripping height, if applicable, or otherwise from the point of contact between the workpieces; the depth limits are controlled based on this sum. The switching time runs from the end of the first full-power heating phase to the moment the table comes into contact with the workpieces: if the second full-power phase is used, its duration is included in the switching time.

Appearance: full-screen pop-up with the title Heating / Depth, four cards at the top and the graph below.

Heating / Depth

Warm-up / Depth

The Heating / Depth pop-up displays the results of the heating phase of the last welding cycle, broken down by table and head. It opens by tapping the Welding Depth card.

It contains four cards at the top (Table, Head, Time, Switchover time) and, below, a graph showing the depth of the table and head during the heating phase. The values on the cards are those displayed when the pop-up is opened: to see the updated values after a new cycle, close and reopen the pop-up.

To close the pop-up, tap the down arrow.

Availability: only on infrared (IR9, IR14, IR20) and with a hot plate (HP9, HP14, HP20, HP-P125) machines.

Appearance: full-screen pop-up with the title Heating and the subtitle Depth, four grey cards with an icon and a value in white digits, and a graph with two curves.

Position: Machine Status > CONTROL PAGE, Heating / Depth pop-up (by tapping the Weld Depth card).

Table

The Table card shows how far the section of the table has sunk during the heating phase of the last cycle, in millimetres (mm), to three decimal places: on IR machines, this refers to the sinking in front of the mirror; on HP machines, it refers to the sinking against the hot plate.

Availability: only on infrared (IR9, IR14, IR20) and with a hot plate (HP9, HP14, HP20, HP-P125) machines.

Appearance: tab labelled Table, featuring a grey icon of a square with a downward-pointing arrow, and the value followed by mm.

Position: Machine Status > CONTROL PAGE, Heating / Depth pop-up (by tapping the Weld Depth card), first card on the left.

The Head card shows how far the head section sank during the heating phase of the last cycle, in millimetres (mm), to three decimal places.

Availability: only on infrared (IR9, IR14, IR20) and with a hot plate (HP9, HP14, HP20, HP-P125).

Appearance: a tab labelled Head, featuring a grey icon of a square with a downward-pointing arrow, and the value followed by mm.

Position: Machine Status > CONTROL PAGE, Heating / Depth pop-up (by tapping the Weld Depth card), second card from the left.

Weather

The Tempo tab displays the heating time for the last cycle, in seconds (s), to two decimal places. The heating time is set under Equipment Settings > Welding Parameters.

Availability: only on infrared (IR9, IR14, IR20) and hot plate (HP9, HP14, HP20, HP-P125) machines.

Appearance: tab titled Time, featuring a grey clock icon with a tick mark and the value followed by s.

Position: Machine Status > CONTROL PAGE, Heating / Depth pop-up (by tapping the Welding Depth card), third card from the left.

Switching time

The Switching time tab shows the time elapsed in the last cycle between the end of heating and the parts coming into contact, in seconds (s): this is the time taken for the mirror or blade to move out of the working area and for the parts to approach each other. A shorter time reduces the cooling of the surfaces prior to joining.

Availability: only on infrared (IR9, IR14, IR20) and with a hot plate (HP9, HP14, HP20, HP-P125) machines.

Appearance: tab with the title Switchover time, a grey clock icon with a tick, and the value followed by s.

Position: Machine Status > CONTROL PAGE, Heating / Depth pop-up (by tapping the Welding Depth card), fourth card from the left.

Heating chart

The graph shows the depth of the head and the table over time during the heating phase of the last cycle, in mm. Below the graph, for each axis, the eye icon shows or hides the corresponding curve.

Availability: only on infrared (IR9, IR14, IR20) and with a hot plate (HP9, HP14, HP20, HP-P125).

Appearance: graph on a dark grey background with two coloured curves, Head and Table, and the legend with the eye icon below the graph.

Position: Machine Status > CONTROL PAGE, Heating / Depth pop-up (by tapping the Weld Depth tab), below the tabs.

Cycle time

The Cycle time tab shows the duration of the last completed welding cycle, in seconds (s), to two decimal places.

The cycle time is the benchmark for assessing the machine’s productivity. It starts when the cycle begins (including clamping of the workpieces and closing of the gates) and stops after the gates have opened: on machines with vibration and laser systems, at the start of unloading; on machines with an IR mirror, and on IR and HP machines, when the workpieces are released; unloading is never included. The value is updated in real time, remains static whilst awaiting confirmation of a reject, and is reset to zero at the start of the next cycle.

Appearance: a card with the title Cycle time, a grey clock icon with a circular arrow, and the value in white digits followed by s.

Cycle time

Position: Machine status > CONTROL PAGE, top row of cards, to the right of the Weld depth card.

Welding result

The Welding Result card indicates whether the last completed cycle produced a good part or a reject.

The result is based on the parameters set in Equipment Settings > Welding Parameters and on the limits set in Equipment Settings > Welding Parameters > Welding Limits. When the part is a reject, the reason appears next to the indicator light:

  • Minimum welding time / Maximum welding time;
  • Minimum depth / Maximum depth;
  • Welding start position too low / Welding start position too high;
  • End height too low / End height too high;
  • Minimum welding switching time / Maximum welding switching time (IR and HP machines);
  • a welding error other than those listed above; if the reason is not available, the message Reject appears.

There is only one reason per welding cycle: if several limits are exceeded, the first one is displayed in the following order: minimum time, maximum time, minimum depth, maximum depth, minimum and maximum welding start position, minimum and maximum end welding height, minimum and maximum switching time, table heating heights, head heating heights, other welding machine alarm. The reason is reset at the start of the next welding procedure.

Appearance: a card with the title Weld Result and a round indicator light:

  • green indicator light and the text Good: the welding procedure is within the set limits;
  • red indicator and the reason for rejection;
  • grey indicator, with no text: no result available.
Status Appearance
Pass Pass result
Reject Reject result
No result No result

Position: Machine Status > CONTROL PAGE, top row of cards, on the right; with the Welding Parameters button visible, the card is to its left.

Welding parameters

1.1.16

The Welding Parameters button opens the Equipment Settings > Welding Parameters page directly, allowing you to check or edit the welding parameters for the loaded tool.

The button is only visible to users with access to the Welding Parameters page.

Availability: visible only to users with access to the Welding Parameters page.

Appearance: a box with the text Welding Parameters in white and, to its right, a round green button with a dark icon of an arrow emerging from a square.

Welding Parameters

Position: Machine Status > CONTROL PAGE, top row of cards, far right, next to the Welding Result card.

Cycle chart

The cycle graph shows the trend of the main welding parameters over time, in seconds (s). It appears automatically in automatic mode at the start of welding; the graph is divided into sections, one for each phase of the cycle completed, with the name of the phase (e.g. Stabilisation, Settling, Cooling).

Below each vertical axis, the Show icon displays or hides the corresponding curve. By tapping a curve and dragging the slider, you can read the values point by point.

Icon Action
Show1 Show2 Show3 Show on: displays the curve.
Hide1 Hide2 Hide3 Show off: hides the curve.

The available curves depend on the machine’s technology: see the related entries.

Appearance: graph on a dark grey background with the vertical axes on the left (light blue labels, one per curve), the time axis at the bottom and, beneath each vertical axis, a light blue eye icon. To the right of the graph, the Current phase box showing the active phase remains visible.

Cycle graph

Position: Machine Status > CONTROL PAGE, central area, to the left of the Current phase box.

Cycle chart – IR and HP

On infrared (IR) and hot plate (HP) machines, the welding graph shows two curves: the force (kgf) and the depth (mm).

During preheating, the preheating graph appears in place of the welding graph, showing the depth of the head and the table (mm); the Current phase box displays the Preheating phase with the red heat waves icon. The same graph opens when you tap the Welding depth tab.

Preheating graph

Stages of the cycle

In automatic mode, the central area of the page shows the progress of the cycle, stage by stage. In the centre is the current stage, illustrated and labelled; on either side, in a paler shade, are the previous and next stages. At the bottom, there is a strip displaying icons for all the stages of the cycle, with a green line beneath those that have already been completed.

What the machine does in each stage and which components it is waiting for is described on the Tool Settings > Cycle Settings page: see the linked entry.

From the start of the heating or welding process, the stages move into a narrow box on the right, labelled Current Stage, and the cycle graph appears in the centre.

The icon in the top-right corner of the area changes the display:

Icon Action
Expand Expand: displays the diagram in full-screen mode.
Collapse Collapse: displays the cycle phases in full-screen mode.

Appearance: colour illustrations of the stages (tools, parts, gates) under the heading Current stage; the active stage is larger and brighter. In the menu on the right-hand side of the screen, the automatic cycle icon (two circular arrows) lights up in green and the manual hand icon turns grey.

Cycle stages

Position: Machine status > CONTROL PAGE, central area; the Expand / Collapse icon is in the top-right corner of the area.

Production batch

The Production batch shows how many good parts have been welded compared to the total number of parts in the batch.

  • The first number is the count of good parts in the current batch.
  • The field to the right of the bar is the batch size: tap it to change it.
  • The Reset button resets the batch count to zero after confirmation. If the Reset piece count with password option is enabled in Machine settings > General settings, the reset requires a password to proceed.

When the batch is managed by an external system, the batch size cannot be changed and the Reset button does not appear.

When the count reaches the set size (other than zero), the current cycle is completed, but another cycle cannot be started until the batch is reset to zero; the HMI displays a ‘batch completed’ pop-up. No alarm is generated.

When the vacuum cycle is active, the vacuum cycle box appears in place of the batch, showing the number of vacuum cycles performed compared to those set; the set number cannot be changed from this page and the Reset button does not appear. The yellow DRY indicator also appears in the top bar of the screen.

Appearance: a box with a grey icon of a pyramid made up of small squares and the text Production batch, followed by the count in white digits, a slash /, the batch size field bordered in green, and a round green button with a circular arrow (Reset). When the vacuum cycle is active, the icon changes to two circular arrows with the text DRY and the field turns grey.

Status Appearance
Production batch Production batch
Vacuum cycle Vacuum cycle

Position: Machine status > CONTROL PAGE, bottom row, on the left.

Piece counter

The Good pieces and Rejects counters show how many good pieces and how many rejects have been produced since the last reset.

The Reset button to the right of the counters resets both of them after confirmation; the Production batch has its own reset and does not change. If the option Reset piece count with password is enabled in Machine settings > General settings, the reset requires password authentication.

The counters also include test cycles and idle cycles; idle cycles do not check the welding limits and are normally recorded as ‘good’. A cycle that is interrupted by exiting the automatic cycle is not counted as either ‘good’ or ‘reject’.

Appearance: on the left, a green tick with the text Good pieces and the number in green; on the right, a red X with the text Scrap pieces and the number in red; on the far right, a round green button with a circular arrow (Reset).

Piece counter

Position: Machine status > CONTROL PAGE, bottom row, on the right.

Dry run cycle

The Dry run cycle box appears in place of the Production batch when the dry run cycle is enabled: the machine performs repeated cycles automatically for testing purposes. It displays the number of dry run cycles performed and, in the field following the / slash, the number of repetitions set, which cannot be changed from this page.

The vacuum cycle is enabled, along with the number of repetitions, in the Vacuum cycle tab on the Machine Diagnostics > Machine Test page, with Putting into service active. When enabled, the yellow DRY indicator also appears in the top bar.

Appearance: a box containing a white icon of two circular arrows with the text DRY, the text DRY RUN CYCLE, the count in white digits, a slash / and the grey field showing the number of repetitions.

Dry run cycle

Position: Machine Status > CONTROL PAGE, bottom row, on the left, in place of the Production batch.

Scrap piece(s)

The SCRAP PIECE(S) box appears at the end of a cycle that results in a reject when the machine is set to request confirmation: the message Confirmation required to continue indicates that the machine remains stopped until the operator confirms that they have seen the scrap piece by tapping the button with the tick symbol.

With the Confirmation required with login behaviour, the button can only be used by a logged-in user who has the Allow tool unlock permission (Machine settings > Password/badge); for other users, tapping the button opens the login pop-up. After confirmation, the button turns grey.

Availability: machine option: appears if Rejection behaviour is set to Confirm request or Confirm request with login (Machine settings > General settings > Optionals, Rejection behaviour); option configured by CEMAS.

Appearance: large text SCRAP PIECE(S), below the message and, to the right, a round green button with a black tick.

Position: Machine Status > CONTROL PAGE, central area, in place of the cycle graph.

Feedback requested

The Feedback Requested box asks the operator, at the end of the cycle, to check the part on the tool and indicate whether it is good or a reject. The cycle waits for a response.

  • Select the green tick (good part) or the red X (reject).
  • For rejects, select the type of reject from the drop-down menu; for some types, the Description field (up to 250 characters) also appears, and is mandatory when the message A description is required for this type of reject appears below.
  • Tap the tick button to confirm: this can only be used once the selection is complete.

The operator’s judgement overrides that of the machine in the Production Report, where the Result column also shows the original outcome. Reject types are set for each tool in the Reject Type pop-up on the User Feedback card.

Availability: tool option: appears if User Feedback is set to Always, or Only with scrap and the machine classifies the cycle as scrap (Equipment Settings > Configuration, User Feedback tab).

Appearance: large text reading Feedback required with the message, two selection buttons showing a green tick and a red X, the drop-down menu for the reject type and, on the right, the round green button with a tick.

Position: Machine Status > CONTROL PAGE, central area, in place of the cycle graph.

Alarm monitor

The Alarm Monitor page displays the active alarms on the machine and the history of past alarms.

The page is organised into tabs:

  • Current alarms: a list of active alarms, with a Reset button;
  • Alarm History: alarms recorded over a specific time period, filterable by category;
  • Smart Accessory: alarms from the smart accessory, available only on machines equipped with one.

Appearance: at the top are the tabs with white text; the selected tab has a darker background than the others. Below, the list of alarms on rows coloured according to category.

Alarm Monitor

Alarm Monitor tabs

Position: Machine Status > Alarm Monitor menu. The same tabs also open in a pop-up when you tap the alarm button on the top bar of the screen: the button with the warning triangle and the number of active alarms, which flashes red when there are alarms.

Current alerts

The Active Alarms tab lists the active alarms on the machine, one per line, showing the ID, Event Time and Alarm Message.

Tapping the arrow to the right of a row expands the row to show the alarm description; in help mode, the badge on the row opens the alarm’s information card in the alarm guide, showing possible causes and corrective actions.

The Reset button, below the list, acknowledges the alarms. If the Reset faults with password option is enabled in Machine settings > General settings, the reset requires a password to proceed.

The list is updated every second. Stored alarms (welding limits, cycle alarms) disappear upon reset and reappear at the next check if the cause is still present. Alerts linked to a condition (safety features, incomplete checklist, test cycle required, initialisation required, movement constraints disabled) remain as long as the condition is present and disappear automatically, without requiring a reset.

When there are no active alarms, the tab displays the message No alarms present.

Appearance: the colour of the row indicates the alarm category.

Category Appearance Meaning
Alarm red row with yellow text Alarm condition preventing the machine from operating
Warning yellow row with black text abnormal condition that may prevent the automatic cycle but not manual operation
Info dark grey row with white text Info information for the operator that does not affect operation

To the right of each line is a small downward-pointing arrow, which changes to an upward-pointing arrow when the line is expanded. The Reset button is round, green, with a dark circular arrow icon.

Expanded alarm

Reset

Position: Machine Status > Alarm Monitor page, first tab; the Reset button is in the centre, below the list.

Id

The Id column shows the alarm identification code, consisting of a letter, a number and an index (for example, M44000-0.01). This code enables you to find the alarm in the alarm guide and to report it to the support team.

Position: Machine Status > Alarm Monitor page, Active Alarms and Alarm History tabs, first column of the list.

Time of the event

The Event time column shows the date and time when the alarm was triggered.

Position: Machine status > Alarm monitor page, Active alarms and Alarm history tabs, second column of the list.

Report text

The Alarm Text column provides a brief description of the alarm: it specifies the part of the machine affected and the condition detected, separated by the symbol >.

Position: Machine Status > Alarm Monitor page, Current Alarms and Alarm History tabs, last column of the list.

Alarm history

The Alarm History tab lists the alarms recorded by the machine over a given time period, to check for any problems that have arisen.

  • The time period is selected using start and end dates; by default, it covers the last two days.
  • The Alarm, Warning and Info checkboxes filter the list by category: if none are selected, all categories are displayed.
  • The list shows ID, Event time, Category and Message text; below the list are the ‘Previous’ and ‘Next’ buttons and the total number of entries found.

If there are no alarms within the range, the tab displays the message No alarms found.

Layout: at the top, a bar with, on the left, the two dates in white, each with a round green calendar button, and on the right, the three tick boxes with green borders; below, the column headings and the list.

Alarm history

Position: Machine Status > Alarm Monitor page, second tab.

Id

The Id column shows the alarm identification code, consisting of a letter, a number and an index (for example, M44000-0.01). This code enables you to find the alarm in the alarm guide and to report it to the support team.

Position: Machine Status > Alarm Monitor page, Active Alarms and Alarm History tabs, first column of the list.

Time of the event

The Event time column shows the date and time when the alarm was triggered.

Position: Machine status > Alarm monitor page, Active alarms and Alarm history tabs, second column of the list.

Report text

The Alarm Text column provides a brief description of the alarm: it specifies the part of the machine affected and the condition detected, separated by the symbol >.

Position: Machine Status > Alarm Monitor page, Current Alarms and Alarm History tabs, last column of the list.

Selecting a time range

Selecting a time range limits the list to data falling between a start date and time and an end date and time.

Tapping the button next to each date opens the date and time selector; the list is updated with the new range. When opened, the range covers the last two days in the Alarm Monitor and the Production Report, and the last 30 days in Statistical Process Control.

Icon Action
Select start date Select end date Date selection: sets the start or end date and time of the range.

Appearance: two blank date fields, each followed by a round green button with a dark calendar icon.

Time interval

Position: top left of the Alarm History tab on the Machine Status > Alarm Monitor page, and on the Machine Status > Production Report and Machine Status > Statistical Process Control pages.

Filter by category

The Alarm, Warning and Info checkboxes filter the history by category: if one or more checkboxes are ticked, the list shows only the alarms in those categories; if none are ticked, it shows them all.

Appearance: three square tick boxes with green borders, each followed by the category name in white.

Filter by category

Position: Machine Status > Alarm Monitor page, Alarm History tab, top right.

Category

The Category column indicates the type of message: Alarm (a fault that stops the machine or the machine cycle), Warning (a fault requiring attention) or Info (information on the machine’s status). The categories can be filtered using the boxes in the top right-hand corner.

Position: Machine Status > Alarm Monitor page, Alarm History tab, third column of the list.

Pages from the historian’s work

Below the list of past alarms, the buttons with arrows show the previous or next page of the list; between the two buttons appears the current page number out of the total (for example, 1/5) and, on the left, the total number of records found (Records).

Appearance: two round green buttons with an arrow pointing left and right; the button is greyed out when there are no further pages in that direction.

Position: Machine Status > Alarm Monitor page, Alarm History tab, bar below the list, centred.

Machine

The Machine tab displays the welding machine’s alarms: it contains the Current Alarms and Alarm History tabs and, on machines equipped with the smart accessory, the Smart Accessory tab.

Appearance: a tab labelled Machine, above the alarm tabs.

Position: Machine Status > Alarm Monitor page, top-left tab.

Smart accessory

The Smart accessory tab displays the alarm page for the smart accessory – the external device connected to the machine – as presented by the device itself. Until the machine is connected to the smart accessory, a message stating that the connection is in progress is displayed.

The alarms on this tab do not appear in the Current Alarms and Alarm History lists: for causes and remedies, refer to the smart accessory’s documentation.

Availability: machine option: appears only on machines with a smart accessory that has an alarms page; option configured by CEMAS.

Appearance: tab labelled Smart accessory; the content is the smart accessory’s web page.

Position: Machine Status > Alarm Monitor page, Machine tab, third tab, to the right of Alarm History.

Production report

The Production Report page displays the history of the welding cycles carried out by the welding machine, one cycle per row, showing the main results for each cycle.

  • Top bar: date range (the last two days are displayed by default), tool selection and the Update list button.
  • Cycle table: the Date/Time and Result columns remain visible at all times; the others can be scrolled through by dragging the table to the left. For each cycle, there are buttons for the process graph and cycle alarms.
  • Bottom bar: number of cycles found, previous and next pages, export to USB stick.

If there are no cycles within the specified range, the page displays the message No records found.

Production report

Appearance: top bar showing the two dates, the Select... drop-down menu with a green border and the text Update list with the round green button featuring two circular arrows.

Top bar

Position: Machine status > Production report menu.

Export

Option

The Export button saves the report cycles to a USB stick in an Excel file with the date and time in the filename (… Export data.xlsx). A confirmation message appears once the export is complete.

The button can only be used when a USB stick is connected to the panel.

Availability: machine option: this appears in the Production Report if Enable export is enabled (Machine settings > General settings > Optionals, Production Report); in Product Selection if Import/Export tool parameters is enabled (Machine settings > General settings > Optionals).

Appearance: a round green button with an arrow icon emerging from a box; next to it, a small red badge with the USB symbol when no USB stick is connected.

Export

Position: Machine Status > Production Reports page, bottom bar, on the right.

Report controls

Icon Action
Next page Next page: displays the cycles on the next page.
Previous page Previous page: displays the cycles on the previous page.
Export Export: saves the cycles for the selected range to a USB stick.
Refresh Refresh list: reloads the cycles for the selected time period and tools; the list is also loaded when the page is opened.

Position: Machine Status > Production Reports page: Refresh list in the top-right bar; the other commands are in the bottom bar.

Next page

The Next Page button displays the cycles on the next page of the table; the Previous Page button takes you back to the previous page. Between the two buttons, the current page number out of the total is shown (for example, 1/5); to the left is the total number of cycles found (Records).

Appearance: two round green buttons with an arrow pointing to the right (next) and to the left (previous); the button is greyed out when there are no further pages in that direction. The buttons only appear when the machine cycles span more than one page.

Pages

Position: Machine Status > Production Report page, bottom bar, on the left.

Previous page

The Previous Page button displays the rows on the previous page of the table.

Appearance: a round green button with a left-pointing arrow; it is greyed out when the table is already displaying the first page.

Pages

Position: Machine Status > Production Report page, bottom bar, to the left of the page number.

Selecting a time range

Selecting a time range limits the list to data falling between a start date and time and an end date and time.

Tapping the button next to each date opens the date and time selector; the list is updated with the new range. When opened, the range covers the last two days in the Alarm Monitor and the Production Report, and the last 30 days in Statistical Process Control.

Icon Action
Select start date Select end date Date selection: sets the start or end date and time of the range.

Appearance: two blank date fields, each followed by a round green button with a dark calendar icon.

Time interval

Position: top left of the Alarm History tab on the Machine Status > Alarm Monitor page, and on the Machine Status > Production Report and Machine Status > Statistical Process Control pages.

Tool selection

The Select... drop-down menu restricts the table to the cycles of a single tool. If no selection is made, the table displays the cycles of all tools within the range. After a tool change, press Refresh list if the table does not update.

Appearance: drop-down menu labelled Select... (or the name of the selected tool), with a green border and a small down arrow.

Tool selection

Position: Machine Status > Production Report page, top bar, centre.

Report information

After selecting the time interval of interest and, if necessary, the tool for which you want to view the report, the page will always display some information.

Cycle graph and alarms

At the start of each row in the table there are two buttons:

  • Graph: opens the cycle process graph in full-screen mode (force and depth over time, with phase bands), showing the code and name of the tool and the workpiece’s serial number in the title bar. If the cycle has no process data, a message appears.
  • Alarms: opens the Alarm History showing the alarms recorded during that cycle.

Appearance: two round buttons side by side: the first is green with a broken line icon (graph), the second has a warning triangle icon; it is bright green if the cycle has alarms and dark green (inactive) if it does not.

Cycle buttons

Process graph

Position: Machine Status > Production Reports page, cycle table, first column of each row.

Date/Time

The Date/Time column shows the date and time of the cycle, in the time zone set on the machine.

Position: Machine Status > Production Reports page, cycle table, Date/Time column.

Result

The Result column indicates whether the cycle produced a good part or a reject. If the operator has corrected the result after the cycle, the machine’s original result and an arrow appear in small grey text before the final icon.

Appearance: a green tick for a good part, a red X for a reject.

Result

Position: Machine Status > Production Report page, cycle table, Result column.

ID

The ID column shows the identification number of the tool used to run the cycle.

Position: Machine Status > Production Reports page, cycle table, ID column.

Name: CEMAS

The CEMAS Name column shows the tool code assigned by CEMAS.

Position: Machine Status > Production Report page, cycle table, CEMAS Name column.

Customer name

The Customer Name column shows the name of the tool used by the customer.

Position: Machine Status > Production Reports page, cycle table, Customer Name column.

Serial number

The Serial number column shows the serial number of the part welded during the cycle.

Position: Machine status > Production reports page, cycle table, Serial number column.

Model

The Model column indicates the side of the tool to which the part has been welded, for tools with multiple sides or models.

Availability: machine option: appears if Single-cavity machine is not enabled (Machine settings > General settings > Optionals).

Position: Machine status > Production report page, cycle table, Model column.

Cycle time

The Cycle time column shows the duration of the cycle, in seconds (s).

Position: Machine status > Production reports page, cycle table, Cycle time column.

Welding time

The Welding time column shows the duration of the weld during the welding cycle, in seconds (s), to two decimal places. This is the same value as the Welding time field on the CONTROL PAGE at the end of the welding cycle.

The meaning of the value depends on the machine’s technology: see the related entries.

Position: Machine Status > Production Report page, cycle table, Welding time column.

Welding time – IR and HP

For infrared (IR) and hot plate (HP) machines, this column shows the duration of the stages during which the workpieces, after heating, are joined under pressure; it does not include the heating, changeover time or cooling under pressure.

Depth

The Depth column shows the welding depth achieved during the cycle, in millimetres (mm).

Position: Machine Status > Production Reports page, cycle table, Depth column.

Welding start position for table welding

This column shows the position of the workpiece at the start of welding, in millimetres (mm). On machines with vibration and laser, this is the position at the end of transducer stabilisation (or settling, if active); on IR and HP machines, it is the reference depth: the piece taking grip, if fitted, or otherwise the point of contact between the workpieces. On vibration machines with an IR mirror, the position is recorded at the start of vibration even when the depth is measured by the piece taking gripper: in this case, the difference between the final and initial positions does not correspond to the depth.

Position: Machine Status > Production Report page, cycle table, Welding start position table column.

End-of-welding position on the table

This column shows the position of the table at the end of welding, in millimetres (mm). The difference between the end and start positions corresponds to the table’s depth.

Position: Machine Status > Production Report page, cycle table, Table end-of-welding position column.

Welding start position of the welding head

This column shows the position of the head at the start of welding, in millimetres (mm); it is relevant for machines with a movable head (IR and HP).

Position: Machine Status > Production Report page, cycle table, Welding start position column.

End-of-welding height (head)

This column shows the position of the head at the end of welding, in millimetres (mm); it is relevant for machines with a movable head (IR and HP).

Position: Machine Status > Production Report page, cycle table, Head end-of-weld position column.

Rejection code

The Reject Code column shows the reason why the machine classified the cycle as a reject, i.e. the welding limit was exceeded: Minimum welding time or Maximum welding time, Minimum depth or Maximum depth, Welding start position too low or too high, End welding start position too low or too high, Minimum or maximum welding switching time (IR and HP only), or Other welding error for other welding errors. For good parts, the cell is empty.

The limits are set in Equipment settings > Welding parameters, Welding limits tab.

Position: Machine status > Production report page, cycle table, Reject code column.

Discard

The Reject column shows the type of reject indicated by the operator in the Feedback Requested box on the CONTROL PAGE, when the tool requests feedback from the operator. If no feedback is provided, or for good parts, the cell is left blank.

*Availability*: tool option: this column is populated only when User Feedback is enabled (Tool Settings > Configuration, User Feedback** tab).

Position: Machine Status > Production Report page, cycle table, Reject column.

Icons

The last column of the table, which has no title, displays an icon for each specific condition active during the cycle; for a normal cycle, it is empty. The icons are used to identify cycles that should not be regarded as part of regular production.

Icon Meaning
Parameters not saved Parameters not saved: the cycle was run with changes to the tool parameters that have not yet been saved.
Putting into service Putting into service: the cycle was run with Putting into service active.
Configuration mode Configuration mode: the cycle was run with Configuration mode active.
Vacuum cycle Vacuum cycle: the cycle was carried out as a vacuum cycle (Vacuum cycle).

Appearance: up to four grey icons side by side: a floppy disk with a pencil, the tools for putting into service, the configuration mode cog, and circular arrows with the text DRY.

Position: Machine Status > Production Reports page, cycle table, far-right column.

Statistical Process Control

The Statistical Process Control (SPC) page analyses the results of the cycles recorded for a tool over a period of time: for each cycle parameter, it displays the distribution of values, the trend over time and the process capability indices, as well as the breakdown of rejects by cause.

  • Filter bar at the top: date range (the last 30 days by default), tools, side, number of sigma and the result of the parts to be considered.
  • Results area: on the left, the list of parameters (Welding time, Weld depth, Welding start position, End welding position, Welding cycle time) and the Rejects tab; in the centre, the graph of the selected parameter; on the right, the statistical values.
  • Bottom bar: number of cycles analysed.

Until a tool is selected, the page displays the message No results found (Please enter the correct filters); if there are not at least three cycles for the tool within the specified range, No records found appears. The page analyses the same cycle history as that available under Machine status > Production reports.

Availability: machine option: the page appears if Statistical Process Control is enabled (Machine Settings > General Settings > Optionals); this option is configured by CEMAS.

Position: Machine Status > Statistical Process Control menu.

Selecting a time range

Selecting a time range limits the list to data falling between a start date and time and an end date and time.

Tapping the button next to each date opens the date and time selector; the list is updated with the new range. When opened, the range covers the last two days in the Alarm Monitor and the Production Report, and the last 30 days in Statistical Process Control.

Icon Action
Select start date Select end date Date selection: sets the start or end date and time of the range.

Appearance: two blank date fields, each followed by a round green button with a dark calendar icon.

Time interval

Position: top left of the Alarm History tab on the Machine Status > Alarm Monitor page, and on the Machine Status > Production Report and Machine Status > Statistical Process Control pages.

Tools

The drop-down menu is used to select the tools whose cycles are to be analysed. The list contains the codes of tools that have at least one recorded cycle. When the page opens, the loaded tool is already selected, provided it has recorded cycles; otherwise, the menu displays Select... and the page remains blank until a tool is selected.

Appearance: a green-bordered drop-down menu displaying either the tool code or the text Select....

Position: Machine Status > Statistical Process Control page, top filter row, second tab from the left, to the right of the dates.

Side

The drop-down menu limits the analysis to cycles on one side of the tool:

  • LH+RH: all cycles, on both sides;
  • LH or RH: only cycles performed on the left or right side.

The side also determines the limits used to calculate Cp and Cpk: those set for LH, for RH or for LH+RH in the tool’s Welding Limits. On single-cavity tools, leave it set to LH+RH.

The Trend over time and Variation graphs always take all cycles into account, without any side-based filtering.

Appearance: small drop-down menu with a green border, displaying LH+RH, LH or RH.

Position: Machine Status > Statistical Process Control page, top row of filters, third tab from the left.

Sigma number

The σ drop-down menu allows you to select the amplitude of the Distribution graph, in terms of the number of standard deviations (sigma) on either side of the mean, from 1 to 10; the default value is 4. With a value of 4, the graph covers values between the mean − 4σ and the mean + 4σ; values further away do not appear on the graph but are still included in the calculation of the mean, standard deviation and indices.

Each sigma is divided into 10 intervals: as the number of sigmas increases, the graph widens whilst the bars remain the same width.

Appearance: a tab with the Greek letter σ and a small drop-down menu with a number from 1 to 10.

Position: Machine Status > Statistical Process Control page, top filter row, fourth tab from the left.

Result

The drop-down menu allows you to select which runs to include in the analysis:

  • Good runs (default selection): only runs with a ‘good’ outcome, i.e. where the process was carried out under accepted production conditions;
  • Rejected parts: only rejected cycles, to investigate the causes of rejects;
  • All: all cycles.

The Rejects tab always counts all rejects for the interval, regardless of the selection.

View: a drop-down menu with a green border offering the options Good parts, Scrap pieces or All.

Position: Machine Status > Statistical Process Control page, top filter row, last tab on the right.

Cycle parameters

The vertical tabs allow you to select the parameters of the welding cycle to be analysed:

  • Welding time, in seconds (s);
  • Welding depth, in millimetres (mm);
  • Welding start position and End welding position, the table’s positions at the start and end of welding, in mm;
  • Cycle time, in s.

For each parameter, the table displays the Distribution or Time trend graph – selected using the icons above the graph – with the statistical values shown on the right. These are the same parameters recorded for each cycle in the Production Report; the limits are those of the tools: Welding limits for the welding parameters, and Cycle time limits for the cycle time.

The meaning of the value depends on the machine’s technology: see the related entries.

View: tab column showing the names of the parameters; the selected tab is highlighted.

Distribution of Welding Depth by technology:

Position: Machine Status > Statistical Process Control page, results area, left-hand tab column.

Distribution

The Distribution graph shows how many units fell within each value of the selected variable:

  • Units produced: number of cycles in each value interval (one-tenth of a sigma);
  • the theoretical normal distribution curve calculated from the mean and standard deviation, to compare the actual shape with the expected one;
  • an orange line at the Mean and yellow lines at the Lower limit and Upper limit, if set;
  • background bands marking the standard deviations from the mean (−1σ, +1σ, …).

A stable process has bars clustered around the mean and far from the limits. Tapping the graph displays the value and the number of pieces.

With this graph, Standard deviation, Cpk and Cp also appear on the right.

Appearance: tab with a bell curve icon; coloured bars and curve on a dark, banded background, with orange and yellow vertical lines.

Position: Machine Status > Statistical Process Control page, results area, first icon above the graph.

The Trend over time graph shows the value of the selected parameter for each cycle, represented as a point, in order of date and time, and the trend line calculated from the points (linear regression).

A sloping line indicates a drift in the process, for example due to wear and tear on tools or variations in the material; the Variation on the right quantifies the drift as a percentage. Tapping the graph displays the date, time and value.

With this graph, Variation appears on the right in place of Standard Deviation, Cpk and Cp.

Appearance: tab with a scatter plot icon; coloured points and a straight line in a different colour, with dates on the horizontal axis.

Position: Machine Status > Statistical Process Control page, results area, second icon above the graph.

Lower and upper limits

The Lower Limit and Upper Limit cards display the acceptance limits for the measurement set on the tool, in the unit of that measurement: these are the same limits that the cycle uses to determine whether the part is good or a reject. If no limits are recorded for the tools, the tabs display ??? and Cp and Cpk are not calculated.

The limits are the current ones for the tools, not those in force at the time of each cycle, and depend on the selected Side.

Where to set: Equipment Settings > Welding Parameters, Welding Limits button; for Cycle Time, Equipment Settings > Configuration, Cycle Time card.

Appearance: card with the name in grey and the value in white digits with three decimal places, followed by the unit.

Position: Machine Status > Statistical Process Control page, results area, column of cards to the right of the graph, first and third cards from the top.

Media

The Mean card shows the mean value of the variable across the analysed cycles, in the unit of the variable. In the Distribution graph, this corresponds to the orange line. A mean that lies far from the centre of the limits reduces the Cpk even when the variation is low.

Appearance: card with the name in grey and the value in white digits to three decimal places, followed by the unit.

Position: Machine Status > Statistical Process Control page, results area, column of cards to the right of the graph, second card from the top.

Standard deviation

The Standard Deviation (σ) card shows how much the values of the variable are scattered around the mean, in the unit of the variable: the smaller the value, the more repeatable the process is. Approximately 99.7 per cent of the parts in a stable process fall within three standard deviations of the mean.

This card appears only with the Distribution chart.

Appearance: a card with the name in grey and the value in white digits to three decimal places, followed by the unit.

Position: Machine Status > Statistical Process Control page, results area, card column to the right of the graph, fourth card from the top.

Cpk

The Cpk card shows the process’s actual capability index: it compares the distance of the mean from the nearest limit to three standard deviations. It takes into account both the dispersion and the centring of the process.

As a common benchmark, a Cpk of at least 1.33 indicates a capable process; below 1, some of the parts are not within the limits. If the Cpk is much lower than the Cp, the process has low variation but is not centred: it is advisable to move the mean closer to the centre of the limits.

Without tool limits, or where all values are the same, the card displays ???. The card only appears with the Distribution chart.

Appearance: card with the name in grey and the value in white digits to three decimal places, without units.

Position: Machine Status > Statistical Process Control page, results area, card column to the right of the graph, fifth card from the top.

Cp

The Cp card shows the potential capability index of the process: the ratio of the amplitude of the limit interval to six standard deviations. It indicates the extent to which the process would lie within the limits if it were perfectly centred; it does not depend on the position of the mean.

As a general guideline, a Cp of at least 1.33 indicates that the variation is within the limits; below 1, the variation is wider than the limits. Without tool limits, or where all values are the same, the card displays ???. The card only appears with the Distribution chart.

Appearance: card with the name in grey and the value in white digits to three decimal places, without units.

Position: Machine Status > Statistical Process Control page, results area, card column to the right of the graph, bottom-most card.

Change

The Variation card shows by how much the quantity has changed over the analysed interval, relative to the trend line on the Trend over time graph, expressed as a percentage (%): the difference between the value of the trend line at the last and first cycles, relative to the value at the first cycle. A positive value indicates an increasing quantity, a negative value a decreasing one; a value close to zero indicates a process with no trend.

This card appears only with the Trend over time graph.

Appearance: card with the name in grey and the value in white digits with one decimal place, followed by %.

Position: Machine Status > Statistical Process Control page, results area, card column to the right of the graph, fourth card from the top.

Waste

The Rejects tab shows how many parts were rejected for each cause within the selected time range, for the selected tools and side: minimum or maximum welding time, minimum or maximum depth, or start or end position too low or too high. For each cause, there is a bar proportional to the proportion of rejects, the number of parts and the percentage of total rejects.

This tab always counts all rejects, regardless of the Result filter. If there are no rejects, the message No rejects produced appears.

Appearance: tab labelled Scrap; list of causes, each with its name in grey, a green bar on a light grey background, and to the right the number of pieces (pcs) and the percentage.

Position: Machine Status > Statistical Process Control page, results area, last tab in the left-hand column.

Number of cycles

The bar at the bottom shows the number of cycles analysed using the selected filters.

With at least 50 cycles, the bar is green and shows the number of cycles (for example, 120 cycles). With fewer than 50 cycles, the bar is orange and displays Insufficient number of samples along with the number of cycles and the minimum required: the results can be viewed, but are not very reliable. In this case, widen the date range or select All in the Result filter.

Appearance: full-width bar with white text in the centre; green when there are at least 50 cycles, orange when there are fewer.

Position: Machine Status > Statistical Process Control page, results area, bar at the bottom.