Skip to content

Alarms

The alarm guide is a troubleshooting guide for the alerts displayed by the welding machine on the Machine Status > Alarm Monitor page. Each alarm explains what it means, how it affects the machine, the probable causes, the verification procedure, how to reset it and on which machines it may appear; below the alarm, the cause entries describe how to recognise and verify each cause.

The alerts are divided into two groups:

  • Tool Alarms: fitted tools (actuators, presence sensors, voids, controls, Smart Tool, tool status);
  • Machine Alarms: the welding machine (services, axes, tool interfaces, safety devices, machine cycles, heating sources and systems, cooling).

Alarm code: each alarm has a code such as M09000-1.03:

Part Example Meaning
letter M M machine alarm, T tool alarm
two digits 09 unit (component)
single digit 0 sub-group
two digits 00 alarm number within the unit
digit after the hyphen 1 zone: 0 general, 1 front, 2 table, 3 mirror (rear/left), 4 right-hand mirror
two digits after the full stop 03 element number (e.g. actuator 3); 01 for individual components

In the manual, the element number is indicated as XX.

Category: the colour of the row in the Alarm Monitor indicates the category: Alarm (red), Warning (yellow), Info (grey). The actual effect on the machine is described for each alarm in the Effect paragraph.

Reset: stored alarms are cleared once the cause has been rectified, using the Reset button on the Current Alarms tab (or via the external alarm reset signal, if connected), and reappear if the cause is still present; notifications linked to a condition disappear automatically. If the Reset faults with password option is enabled in Machine settings > General settings, the reset requires password authentication.

Before working on the electric panel, pressurised circuits, lasers, hot surfaces or moving parts, secure the machine in accordance with the user manual. If an alarm recurs, contact CEMAS Elettra support (Machine Diagnostics > Support).

Tool Alerts

Tool Alarms relate to the fitted tools: actuators, presences, vacuums, input and output commands, Smart Tools and the general status of the tools. The code begins with T and the text in Machine Status > Alarm Monitor begins with Tools, followed by the tools’ serial number in square brackets.

Any equipment alarm stops the machine: if it is in automatic mode, it switches to manual mode and neither the automatic cycle nor the tool change can be initiated. The parameters can be checked in Equipment Settings > Actuators and Presence Sensors; sensors and actuators can be tested manually via Machine Diagnostics > Manual Movements, under the Equipment tab.

Actuator

Alarms relating to machine actuators (clamps, slides, ejectors controlled by the machine’s valves): movements not completed within the expected time, inconsistent position sensors, position constraints not met, configuration of controls, valves and pins. XX is the actuator number; the parameters are found under Equipment Settings > Actuators and Presences, on the Actuators tab, whilst manual tests are found under Machine Diagnostics > Manual Movements, on the Equipment tab.

T01000-0.XX - Actuator - Rest position timeout

What this means: following the sleep command, the sleep sensor did not activate within the Sleep time specified in the Time-out unit (Equipment settings > Actuators and Presence, Actuators tab; default 5 s, −1 disables the check). In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • stroke obstructed (Movement not completed);
  • insufficient air supply or damaged hoses (Pneumatic check);
  • sensor displaced or faulty (Sensors not working);
  • time-out shorter than the stroke (Insufficient time).

How to resolve:

  1. Reset and select Standby in Machine Diagnostics > Manual Movements, Equipment tab: the button must display a green ring.
  2. If the actuator does not move: clear the stroke, check the air supply and hoses (maintenance technician).
  3. If it moves but the green halo does not appear: check the sensor and pins (Input pop-up, Rest tab).
  4. If it is delayed: increase the Rest time.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Move not completed

How to identify it: the actuator stops before reaching the position or reaches it without the sensor sending signals.

Check:

  1. Control the actuator from Machine Diagnostics > Manual Movements, Tools tab, and check whether it reaches the position: the button must display a green halo.
  2. If it stops before reaching the position: check for mechanical obstructions, incorrectly positioned parts or other actuators in the travel path.
  3. If it reaches the position but the green halo does not appear: in the actuator’s Input pop-up (Equipment settings > Actuators and sensors, Actuators tab), under the Idle or Work tab, the assigned pin must light up green when the actuator is in position.

Remedy: clear the travel path; correct the assigned pin (operator authorised to access tool settings) or the sensor wiring (maintenance technician).

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Not enough time

How to recognise this: the actuator reaches the position, but only after the time-out has expired (the green halo appears late).

Check:

  1. Control the actuator via Machine Diagnostics > Manual Movements, Tool tab, and estimate the travel time.
  2. Compare this with the Idle and Operating fields in the Timeout unit (Equipment settings > Actuators and Presences, Actuators tab).

Remedy: if the stroke is smooth but slow, increase the time-out, leaving a margin; if the stroke has become slower than usual, first check the air supply and flow regulators (maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01001-0.XX – Actuator – Working position timeout

What this means: following the work command, the work sensor did not activate within the Work time specified in the Time-out unit (Equipment settings > Actuators and Presences, Actuators tab; default 5 s, −1 disables the check). In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • stroke obstructed (Movement not completed);
  • insufficient air or damaged pipes (Pneumatic control);
  • sensor displaced or faulty (Sensors not working);
  • time-out shorter than the stroke (Insufficient time).

How to resolve:

  1. Reset and select Work in Machine Diagnostics > Manual Movements, Tools tab: the button must display a green ring.
  2. If the actuator does not move: clear the stroke, check the air supply and hoses (maintenance technician).
  3. If it moves but the indicator does not appear: check the sensor and pins (Input pop-up, Work tab).
  4. If it is delayed: increase the Job time.

Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance by a qualified maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to identify it: the actuator stops before reaching the position or reaches it without the sensor sending signals.

Check:

  1. Control the actuator from Machine Diagnostics > Manual Movements, Tools tab, and check whether it reaches the position: the button must display a green halo.
  2. If it stops before reaching the position: check for mechanical obstructions, incorrectly positioned parts or other actuators in the travel path.
  3. If it reaches the position but the green halo does not appear: in the actuator’s Input pop-up (Equipment settings > Actuators and sensors, Actuators tab), under the Idle or Work tab, the assigned pin must light up green when the actuator is in position.

Remedy: clear the travel path; correct the assigned pin (operator authorised to access tool settings) or the sensor wiring (maintenance technician).

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Not enough time

How to recognise this: the actuator reaches the position, but only after the time-out has expired (the green halo appears late).

Check:

  1. Control the actuator via Machine Diagnostics > Manual Movements, Tool tab, and estimate the travel time.
  2. Compare this with the Idle and Operating fields in the Timeout unit (Equipment settings > Actuators and Presences, Actuators tab).

Remedy: if the stroke is smooth but slow, increase the time-out, leaving a margin; if the stroke has become slower than usual, first check the air supply and flow regulators (maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01002-0.XX – Actuator – Rest position not released

What this means: after the job command, when the time-out expires (the Job field in the Time-out unit, Equipment settings > Actuators and Presences, Actuators tab), the idle sensor is still active: either the actuator has not started, or the sensor remains on even though the actuator has moved. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until a reset is performed.

Probable causes:

  • actuator held in position (Actuator jammed);
  • no air supply or valve not controlled (Pneumatic control);
  • idle sensor always active (Sensors not working).

How to resolve:

  1. Reset and select Work in Machine Diagnostics > Manual Movements, Tools tab, whilst observing the actuator.
  2. If it does not start: release the components holding it in place, check Safety constraints, air supply and valve (maintenance technician).
  3. If it starts but the idle sensor LED remains lit: adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Actuator jammed

How to recognise this: the actuator does not move, or does not move from its position, when commanded.

Check:

  1. Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
  2. Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
  3. Check that the stroke is free from mechanical obstructions.

Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01003-0.XX - Actuator - Operating position not released

What this means: after the standby command, when the time-out expires (the Standby field in the Time-out unit, Equipment settings > Actuators and Presences, Actuators tab), the work sensor is still active: either the actuator has not started, or the sensor remains on even though the actuator has moved. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until a reset is performed.

Probable causes:

  • actuator held in position (Actuator jammed);
  • no air supply or valve not controlled (Pneumatic control);
  • work sensor constantly active (Sensors not working).

How to resolve:

  1. Reset and select Rest in Machine Diagnostics > Manual Movements, Tool tab, whilst observing the actuator.
  2. If it does not start: release the components holding it in place, check Safety constraints, air supply and valve (maintenance technician).
  3. If it starts but the work sensor LED remains lit: adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Actuator jammed

How to recognise this: the actuator does not move, or does not move from its position, when commanded.

Check:

  1. Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
  2. Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
  3. Check that the stroke is free from mechanical obstructions.

Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01004-0.XX – Actuator – External alarm

What this means: external actuator alarm, i.e. a fault signalled by a device connected to the actuator rather than by its position sensors. In current versions of the machine software, this alarm is provided for but is not activated. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

T01005-0.XX - Actuator - Both position feedback signals

What this means: the actuator’s idle and operating sensors are active simultaneously: the actuator’s position cannot be determined. Control is continuous. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • a sensor also detects the opposite position (Sensor positioning);
  • faulty sensor or sensor always active (Sensors not working);
  • same pin assigned to both sensors.

How to resolve:

  1. Move the actuator via Machine Diagnostics > Manual Movements, Tools tab, whilst observing the LEDs: only one sensor should light up in each position.
  2. If an LED remains lit at all times: reposition or replace the sensor (maintenance technician).
  3. If the LEDs are correct: check in the Input pop-up (Equipment settings > Actuators and presence, Actuators tab) that Rest and Work have different pins.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Sensor positioning

How to identify this: the component’s two position sensors are active at the same time.

Check:

  1. Move the component to one position and check that only the LED for the corresponding sensor is lit.
  2. Repeat in the other position.
  3. Check that each sensor is securely fitted and detects only its own position.

Remedy: reposition or replace the sensor that remains active (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01006-0.XX – Actuator – Both commands

What this means: the actuator receives both the ‘rest’ and ‘work’ commands simultaneously, for example from two external commands linked in the Input unit of the actuator pop-up window (Equipment settings > Cycle settings). In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • external ‘Idle’ and ‘Work’ commands active simultaneously (Reset the commands);
  • external device sending both signals.

How to resolve:

  1. Note down the input commands associated with Rest and Work (Equipment settings > Cycle settings, actuator pop-up, Inputs unit).
  2. Check in Machine diagnostics > PLC that they are not active simultaneously.
  3. Correct the association or the device sending the commands (maintenance technician).

Reset: once the cause has been eliminated, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Reset the controls

How to recognise it: the Both commands alarm appears when the actuator’s external commands are activated.

Check:

  1. In Equipment settings > Cycle settings, in the actuator pop-up window, under the Input unit, note down the input commands selected for Idle and Operate.
  2. Check in the Signals tab under Machine Diagnostics > PLC that the two commands are not active at the same time.

Remedy: pair commands so that they cannot be active simultaneously, or rectify the device sending them (maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01007-0.XX - Actuator - Not in the rest position

What this means: A movement (table, head, other actuators, repositioning) has been requested that requires the actuator to be in the rest position, but the rest position sensor is not active: the safe position constraint is not met and the movement is not executed. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • actuator out of position or stuck (Actuator jammed);
  • air pressure dropped or absent (Pneumatic control);
  • rest position sensor displaced or faulty (Sensors not working).

How to resolve:

  1. Reset and select Rest in Machine Diagnostics > Manual Movements, Tools tab: the button must display a green ring.
  2. If the actuator does not move: check for obstructions, air supply and the valve (maintenance technician).
  3. If it is in the rest position but the green halo does not appear: check the LED and the sensor position (maintenance technician).
  4. Repeat the required movement.

Reset: once the cause has been rectified, select Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Actuator jammed

How to recognise this: the actuator does not move, or does not move from its position, when commanded.

Check:

  1. Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
  2. Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
  3. Check that the stroke is free from mechanical obstructions.

Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01008-0.XX – Actuator – Not in operating position

What this means: A movement (table, head, other actuators, repositioning) has been requested that requires the actuator to be in operation, but the operational sensor is not active: the safe position constraint is not met and the movement is not executed. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • actuator has retracted or is stuck (Actuator jammed);
  • air pressure has dropped during the cycle (Pneumatic control);
  • work sensor displaced or faulty (Sensors not working).

How to resolve:

  1. Reset and select Operation in Machine Diagnostics > Manual Movements, Tool tab: the button must display a green ring.
  2. If the actuator does not move: check for obstructions, air supply and the valve (maintenance technician).
  3. If it is operating but the green halo does not appear: check the LED and the sensor position (maintenance technician).
  4. Repeat the required movement.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Actuator jammed

How to recognise this: the actuator does not move, or does not move from its position, when commanded.

Check:

  1. Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
  2. Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
  3. Check that the stroke is free from mechanical obstructions.

Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01009-0.XX – Actuator – Incorrect control address

What this means: a command associated with the actuator refers to a non-existent input or output command, for example one that was deleted after the association was made. This is a tool configuration error. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • command deleted or invalid (Reset commands).

How to resolve:

  1. Check the outputs in the actuator’s Commands pop-up (Tooling Settings > Actuators and Presences, Actuators tab, visible in the advanced view).
  2. Check the external commands in the Input unit of the actuator pop-up (Tool settings > Cycle settings).
  3. Choose the correct command or Select signal if it is not required.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.

Reset the controls

How to recognise it: the alarm appears after deleting or modifying the tools’ input or output commands.

Check:

  1. Open the actuator’s Commands pop-up (Equipment Settings > Actuators and Presences, Actuators tab, visible in the advanced view) and check that the selected outputs exist in the Output Commands tab.
  2. Check the external commands in the Input unit of the actuator pop-up (Tool Settings > Cycle Settings).

Remedy: select the correct commands again or Select Signal if they are not required, then save (Save Changes).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01010-0.XX – Actuator – Incorrect valve address

What this means: the valve assigned to the actuator is invalid: the valve number is outside the machine’s range (up to 10). The valve menu is next to the Input button (Equipment settings > Actuators and presences, Actuators tab). In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • valve not selected or does not exist on the interface (Reset the valve);
  • tools created on a machine with different valves.

How to resolve:

  1. In the Cavities unit, check the interface on which the actuator is mounted.
  2. Select the valve that controls the actuator from the menu.
  3. Test the actuator via Machine Diagnostics > Manual Movements, Tooling tab.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Reset the valve

How to recognise it: the alarm appears on a new actuator or after changing the interface in the Cavity unit.

Check:

  1. Check in the Cavity unit (Tooling settings > Actuators and presences, Actuators tab) the interface on which the actuator is mounted.
  2. Check in the valve menu, next to the Input button, that the valve controlling the actuator is selected.

Remedy: correct the interface and valve, save (Save changes) and test the actuator via Machine diagnostics > Manual movements, Equipment tab. With the machine option General valve pack, configured by CEMAS, the valves suggested are always those shown on the table.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01011-0.XX - Actuator - Incorrect actuator connector pin address

What this means: an actuator sensor is assigned to a pin that does not exist on the connector: for a 24-pin connector, pins 3–24 are valid; for a 32-pin connector, pins 3–32; and for a 64-pin or custom connector, pins 1–64. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Possible causes:

  • unassigned or invalid pin (Reset inputs);
  • interface or connector changed after configuration.

How to resolve:

  1. Open the actuator’s Input pop-up (Machine Settings > Actuators and Presences, Actuators tab) and check the selected pin (orange) in the Idle and Work tabs.
  2. Assign the pins from the tool’s wiring diagram.
  3. Check the interface selected in the Cavity unit.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Reset the inputs

How to recognise this: in the actuator’s Input pop-up, the selected pin (orange) is missing from one of the tabs, or an invalid pin has been assigned to the plug.

Check:

  1. Open the actuator’s Input pop-up (Equipment settings > Actuators and presences, Actuators tab) and check the Rest and Work tabs.
  2. Compare the pins with the tool’s wiring diagram.
  3. Check that the interface selected in the Cavities unit is the one to which the sensors are wired.

Remedy: assign the correct pins and save (Save changes).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Attendance

Alarms relating to tool presence, the sensors that monitor workpieces (photocells, microswitches, fibre optics): presence or absence not detected within the expected time, constraints not met, pin and command configuration, anti-repeat check. XX is the presence number; the parameters are found under Equipment Settings > Actuators and Presences, on the Presences tab.

T02000-0.XX - Presence - Presence timeout

What this means: when a presence is expected (automatically or during a tool change), the sensor has not been triggered within the Presence time specified in the Time-out unit (Tool Settings > Actuators and Presences, Presences tab; default 2 s, 0 disables the check). In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): with the presence in Safety mode (Mode unit), the machine switches to manual mode; the automatic cycle and tool change remain blocked. In Normal mode, this is merely a warning.

Probable causes:

  • workpiece missing or incorrectly positioned (Object not present or incorrectly positioned);
  • sensor displaced or out of alignment (Check not carried out);
  • time-out too short (Insufficient time).

How to resolve:

  1. Position the workpiece correctly.
  2. Check in Machine Diagnostics > Manual Movements, under the Fixture tab, that the presence indicator turns green.
  3. If it remains grey whilst the workpiece is in place: check the sensor (maintenance technician).
  4. If it activates too late: increase the Presence time.

Reset: whilst the cycle is running, it remains stored (Reset in the Alarm Monitor); otherwise, it clears automatically.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Item missing or incorrectly positioned

How to identify the problem: the presence indicator remains grey because the part is missing or is not in the position where the sensor detects it.

Check:

  1. Check that the part is in its correct position and correctly seated.
  2. Remove and reinsert the part, observing the presence indicator in Machine Diagnostics > Manual Movements, Tool tab (green = presence active) and the sensor LED.

Remedy: position the workpiece correctly; if the indicator light does not change state with the workpiece in place, the cause is the sensor (see Check not performed or Sensors not working).

Warning Before working in the tools area, secure the machine in accordance with the user manual: moving parts.
Not enough time

How to recognise it: the presence sensor is activated, but only after the time-out has expired, for example because the workpiece reaches the sensor following a movement.

Check:

  1. Observe automatically how long it takes for the presence indicator light to turn green.
  2. Compare this with the Presence field in the Time-out unit (Equipment settings > Actuators and presence, Presence tab; default 2 s).

Remedy: increase the Presence field, leaving a margin, and save (Save changes).

Check not carried out

How to identify this: the part is in place but the presence sensor does not detect it: the sensor LED is off and the presence indicator light is grey.

Check:

  1. Check the sensor LED whilst the component is in place.
  2. Check the sensor’s position, mounting and cleanliness.
  3. Check the calibration (sensitivity or activation distance) in accordance with the sensor manual.

Remedy: reposition, calibrate or replace the sensor (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02001-0.XX – Presence – Absence timeout

What this means: when an absence is expected (either automatically or during a tool change), the sensor has not deactivated within the Absence time specified in the Time-out unit (Equipment settings > Actuators and Presences, Presences tab; default 2 s, 0 disables the check). In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): with the presence in Safety mode (Mode unit), the machine switches to manual mode; the automatic cycle and tool change remain blocked. In Normal mode, this is merely a warning.

Probable causes:

  • workpiece or residue in front of the sensor (Object present or incorrectly positioned);
  • sensor out of calibration or constantly active (Check not carried out);
  • time-out too short (Insufficient time).

How to resolve:

  1. Remove the workpiece and any debris.
  2. Check in Machine Diagnostics > Manual Movements, under the Tool tab, that the presence indicator turns grey.
  3. If it remains green without a workpiece: check the sensor (maintenance technician).
  4. If it takes too long to deactivate: increase the Absence time.

Reset: whilst the cycle is in progress, it remains stored (Reset in the Alarm Monitor); otherwise, it clears automatically.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Object present or incorrectly positioned

How to recognise this: the presence indicator remains green because the workpiece, or a residue, is still in front of the sensor.

Check:

  1. Check that the workpiece has been removed and that there are no scraps or residues remaining in front of the sensor.
  2. Replace and remove the workpiece whilst observing the presence indicator in Machine Diagnostics > Manual Movements, Tooling tab (grey = presence not active).

Remedy: remove the workpiece and any residue; if the indicator light remains green without a workpiece present, the cause is the sensor (see Check not performed or Sensors not working).

Warning Before working in the tools area, secure the machine in accordance with the user manual: moving parts.
Not enough time

How to recognise it: the presence indicator switches off, but only after the time-out has expired – for example, because the part is slowly moving away from the sensor.

Check:

  1. Observe automatically how long it takes for the presence indicator to turn grey.
  2. Compare this with the Absence field in the Time-out unit (Equipment settings > Actuators and presence, Presence tab; default 2 s).

Remedy: increase the Absence field, leaving a margin, and save (Save changes).

Check not carried out

How to recognise this: the object has been removed but the sensor continues to detect it: the sensor LED is on and the green presence indicator is lit.

Check:

  1. Check that the sensor is not detecting fixed parts of the tools or reflections.
  2. Check the sensor’s position, mounting and cleanliness.
  3. Check the calibration in accordance with the sensor manual.

Remedy: reposition, calibrate or replace the sensor (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02002-0.XX - Presence - Incorrect connector pin address

What this means: the presence sensor is assigned to a pin that does not exist on the connector: for a 24-pin connector, pins 3–24 are valid; for a 32-pin connector, pins 3–32 are valid; for a 64-pin or custom connector, pins 1–64 are valid. In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • unassigned or invalid pin (Reset inputs);
  • interface or connector changed after configuration.

How to resolve:

  1. Open the Input pop-up for the presence sensor (Equipment settings > Actuators and presence sensors, Presences tab) and check the selected pin (orange).
  2. Assign the pin from the tool’s wiring diagram.
  3. Check the interface selected in the Cavities unit.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Reset the inputs

How to recognise this: the presence indicator does not match the status of the component, or the Input pop-up does not have a valid pin.

Check:

  1. Open the Input pop-up for the presence sensor (Equipment Settings > Actuators and Presence Sensors, Presence tab): the selected pin (orange) must be the one shown in the wiring diagram and should light up green when the part is detected.
  2. Check the interface selected in the Cavity unit.
  3. Check the Contact unit (visible in the advanced view): Normally Open or Normally Closed depending on the sensor.

Remedy: correct the pin, interface or contact type and save (Save changes).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02003-0.XX - Presence - Absent

What this means: A movement requiring active presence (presence constraint) has been requested, but the sensor does not detect the workpiece: the movement is not executed. In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • workpiece missing or incorrectly positioned (Object not present or incorrectly positioned);
  • sensor displaced or faulty (Sensors not working);
  • pins or contacts incorrectly set (Reset the inputs).

How to resolve:

  1. Position the part correctly.
  2. Check in Machine Diagnostics > Manual Movements, under the Tools tab, that the presence indicator turns green.
  3. If it remains grey: check the sensor (maintenance technician), the pin in the Input pop-up and the Contact unit (Tool Settings > Actuators and Presences, Presence tab).
  4. Repeat the movement.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, ensure the machine is safely shut down in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Item missing or incorrectly positioned

How to identify the problem: the presence indicator remains grey because the part is missing or is not in the position where the sensor detects it.

Check:

  1. Check that the part is in its correct position and correctly seated.
  2. Remove and reinsert the part, observing the presence indicator in Machine Diagnostics > Manual Movements, Tool tab (green = presence active) and the sensor LED.

Remedy: position the workpiece correctly; if the indicator light does not change state with the workpiece in place, the cause is the sensor (see Check not performed or Sensors not working).

Warning Before working in the tools area, secure the machine in accordance with the user manual: moving parts.
Reset the inputs

How to recognise this: the presence indicator does not match the status of the component, or the Input pop-up does not have a valid pin.

Check:

  1. Open the Input pop-up for the presence sensor (Equipment Settings > Actuators and Presence Sensors, Presence tab): the selected pin (orange) must be the one shown in the wiring diagram and should light up green when the part is detected.
  2. Check the interface selected in the Cavity unit.
  3. Check the Contact unit (visible in the advanced view): Normally Open or Normally Closed depending on the sensor.

Remedy: correct the pin, interface or contact type and save (Save changes).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02004-0.XX – Presence – Not absent

What this means: A movement has been requested that requires non-active presence (movement constraint), but the sensor is still detecting an object: the movement is not carried out. In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • workpiece or residue in front of the sensor (Object present or incorrectly positioned);
  • sensor out of calibration or constantly active (Sensors not functioning);
  • pins or contacts incorrectly set (Reset the inputs).

How to resolve:

  1. Remove the part or residue.
  2. Check in Machine Diagnostics > Manual Movements, under the Tools tab, that the presence indicator turns grey.
  3. If it remains green: check the sensor (maintenance technician), the pin in the Input pop-up and the Contact unit (Tool Settings > Actuators and Presences, Presence tab).
  4. Repeat the movement.

Reset: once the cause has been rectified, select Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, ensure the machine is safely shut down in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Object present or incorrectly positioned

How to recognise this: the presence indicator remains green because the workpiece, or a residue, is still in front of the sensor.

Check:

  1. Check that the workpiece has been removed and that there are no scraps or residues remaining in front of the sensor.
  2. Replace and remove the workpiece whilst observing the presence indicator in Machine Diagnostics > Manual Movements, Tooling tab (grey = presence not active).

Remedy: remove the workpiece and any residue; if the indicator light remains green without a workpiece present, the cause is the sensor (see Check not performed or Sensors not working).

Warning Before working in the tools area, secure the machine in accordance with the user manual: moving parts.
Reset the inputs

How to recognise this: the presence indicator does not match the status of the component, or the Input pop-up does not have a valid pin.

Check:

  1. Open the Input pop-up for the presence sensor (Equipment Settings > Actuators and Presence Sensors, Presence tab): the selected pin (orange) must be the one shown in the wiring diagram and should light up green when the part is detected.
  2. Check the interface selected in the Cavity unit.
  3. Check the Contact unit (visible in the advanced view): Normally Open or Normally Closed depending on the sensor.

Remedy: correct the pin, interface or contact type and save (Save changes).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02005-0.XX - Presence - Incorrect command address

What this means: an output command associated with a presence (Commands pop-up, Outputs unit) does not exist or is invalid, for example because it has been deleted from the Output Commands tab. In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • output command deleted or invalid (Reset commands).

How to resolve:

  1. Open the Commands pop-up for presence (Tool Settings > Actuators and Presences, Presences tab, visible in the advanced view).
  2. Select the command for Presence and Absence, or Select signal if not required.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.

Reset the controls

How to recognise it: the alarm appears after deleting or modifying the tools’ output commands.

Check:

  1. Open the Commands pop-up for presence (Equipment settings > Actuators and presences, Presence tab, visible in the advanced view).
  2. Check that the commands selected for Presence and Absence exist in the Output Commands tab.

Solution: select the commands again or Select the signal if they are not required, then save (Save changes).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02006-0.XX - Presence - Anti-duplicate check

What this means: at the start of a new cycle, a presence with Anti-repeat enabled (Equipment settings > Actuators and presences, Presences tab) still detects the part welded in the previous cycle: the machine waits for it to be removed, so as not to weld it twice. In the code, XX is the presence number (from 01 to 20).

Effect: Info (grey line): the cycle does not start until the workpiece is removed; this is not a fault.

Possible causes:

  • Welded part not unloaded (Remove welded part);
  • Sensor out of calibration or constantly active (Sensors not working).

How to resolve:

  1. Remove the welded part.
  2. If the error persists: check under Machine Diagnostics > Manual Movements, Tools tab, that the presence indicator is grey; if it is green, check the sensor (maintenance technician).

Reset: the error clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Remove the welded part

How to recognise this: when the cycle starts, the anti-repeat check appears and the welded part is still in the tool.

Check:

  1. Check whether the part from the previous cycle is still in the tool.
  2. Check which presences have Anti-repeat set to Yes (Tool settings > Actuators and presences, Presences tab).

Remedy: remove the welded part and restart the cycle.

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Vacuum

Tool vacuum alarms, where workpieces are held in place by suction cups or vacuum-sealed cavities: vacuum not reached, lost or not released; pump or vacuum switch input not configured. XX is the vacuum number; the parameters can be found under Tool Settings > Actuators and Presences, on the Vacuum tab.

T03000-0.XX - Vacuum - Vacuum timeout

What this means: with the vacuum valve open, the vacuum switch did not signal a vacuum within the Vacuum timeout set in the Timings unit (Equipment settings > Actuators and Presences, Vacuum tab; default 10 s). In the code, XX is the vacuum number (from 01 to 10).

Effect: Warning (yellow line): the workpiece is not being held; the valve remains open.

Probable causes:

  • workpiece not correctly positioned (Vacuum not reached);
  • damaged suction cups or hoses (Check holding, Pneumatic check);
  • vacuum switch out of calibration or faulty (Check not carried out);
  • time-out too short (Insufficient time).

How to resolve:

  1. Reposition the workpiece.
  2. Activate Vacuum in Machine Diagnostics > Manual Movements, Tool tab: the button must display a green ring.
  3. If the green halo does not appear: check the suction cups, hoses and vacuum switch (maintenance technician).
  4. If the vacuum is delayed: increase the Vacuum time-out.

Reset: this disappears automatically once the vacuum is achieved.

Safety:

Warning Before carrying out any work on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Vacuum not achieved

How to recognise it: when the vacuum is activated, the green ring around the Vacuum button does not appear.

Check:

  1. Check that the workpiece is securely held by the suction cups or in the cavity.
  2. Check the vacuum switch calibration (typical value −0.65 bar) and its LED.
  3. Activate Vacuum via Machine Diagnostics > Manual Movements, under the Tool tab, and check whether a vacuum is achieved.

Remedy: reposition the workpiece; calibrate or replace the vacuum switch (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Check on withholding

How to recognise it: a vacuum is difficult to achieve, is lost shortly afterwards, or remains even after the valve is released.

Check:

  1. Check that the suction cups are undamaged, clean and not deformed.
  2. Check the vacuum lines and fittings: ensure no hoses are punctured, blocked or disconnected.
  3. Activate Vacuum and Blow from Machine Diagnostics > Manual Movements, under the Tools tab, whilst listening for any leaks.

Remedy: replace damaged suction cups or hoses and tighten the fittings (maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Check not carried out

How to identify this: the part is held in place but the vacuum switch does not signal a vacuum (LED off, no glow around Vacuum).

Check:

  1. Check the electrical connection and the vacuum switch LED.
  2. Check the calibration of the vacuum switch.

Remedy: Reconnect, calibrate or replace the vacuum switch (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Not enough time

How to recognise it: the vacuum is achieved, but only after the Vacuum Timeout has expired.

Check:

  1. Select Empty from Machine Diagnostics > Manual Movements, under the Equipment tab, and estimate the time required.
  2. Compare this with the Empty Timeout in the Times unit (Equipment Settings > Actuators and Presences, Empties tab; default 10 s).

Remedy: increase the Vacuum Timeout, allowing for a margin, and save (Save changes); if the vacuum is taking longer than usual, first check for leaks and the pump (maintenance technician).

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T03001-0.XX - Vacuum - Invalid pump

What this means: the vacuum is associated with an invalid pump: the machine supports a maximum of 4 pumps and the assigned number is outside the valid range. This association is part of the machine’s vacuum configuration (Machine Settings > General Settings > Components), set by CEMAS. In the code, XX is the vacuum number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The vacuum valve is closed.

Probable causes:

  • Incorrect pump configuration (Incorrect configuration).

How to resolve:

  1. Check in Equipment Settings > Actuators and Presences, under the Vacuum tab, that the tool is set to use vacuum XX.
  2. If so, have the vacuum and pump configuration checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited **Machine settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Incorrect configuration

How to identify it: the Invalid pump alarm appears as soon as the tool uses a vacuum.

Check:

  1. Note down the vacuum number (XX) indicated in the alarm code.
  2. Check under Equipment Settings > Actuators and Presences, in the Vacuums tab, that the tool is set to use that vacuum.

Remedy: the pump for each vacuum and the machines’ pumps are configured by CEMAS: contact CEMAS Elettra support (CEMAS technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T03002-0.XX – Vacuum – Vacuum not released

What this means: with the vacuum valve closed, the vacuum switch still signals a vacuum after 5 s (fixed value): the workpiece may not be released. In the code, XX is the vacuum number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • workpiece jammed or insufficient blow-off (Workpiece not released);
  • valve failing to close or blocked pipe (Check pneumatic system, Check retention);
  • vacuum switch constantly active (Sensors not working).

How to resolve:

  1. Initiate Blow in Machine Diagnostics > Manual Movements, Tools tab: the part should detach and the Vacuum indicator should go out.
  2. If the workpiece remains attached: increase the Blow time (Equipment settings > Actuators and presences, Vacuum tab, Times unit) and check that it is not jammed.
  3. If it detaches but the vacuum remains indicated: check the valve and vacuum switch (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Check on withholding

How to recognise it: a vacuum is difficult to achieve, is lost shortly afterwards, or remains even after the valve is released.

Check:

  1. Check that the suction cups are undamaged, clean and not deformed.
  2. Check the vacuum lines and fittings: ensure no hoses are punctured, blocked or disconnected.
  3. Activate Vacuum and Blow from Machine Diagnostics > Manual Movements, under the Tools tab, whilst listening for any leaks.

Remedy: replace damaged suction cups or hoses and tighten the fittings (maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Unreleased track

How to recognise it: after the blow, the part remains attached to the suction cups or in the cavity.

Check:

  1. Initiate Blow from Machine Diagnostics > Manual Movements, Tool tab, and observe whether the part detaches.
  2. Check the Blow time in the Timings unit (Tool settings > Actuators and presences, Vacuum tab).
  3. Check that the part is not jammed in its seat.

Remedy: increase the Blow time and save (Save changes); safely remove the part from the machine.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance by a qualified maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T03003-0.XX - Vacuum - Incorrect command address

What this means: a command associated with a vacuum (On and Off outputs in the Commands pop-up or external cycle commands) does not exist or is invalid, for example because it has been deleted. In the code, XX is the vacuum number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The vacuum valve is closed.

Probable causes:

  • command deleted or invalid (Reset commands).

How to resolve:

  1. Check the outputs in the Commands pop-up for the vacuum (Equipment Settings > Actuators and Presences, Vacuum tab, visible in the advanced view).
  2. Check the external commands in the vacuum pop-up (Equipment Settings > Cycle Settings, Input unit).
  3. Choose the correct command or Select signal if not required.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.

Reset the controls

How to recognise it: the alarm appears after deleting or modifying the tools’ input or output commands.

Check:

  1. Open the Commands pop-up for the vacuum (Equipment Settings > Actuators and Presences, Vacuum tab, visible in the advanced view) and check the On and Off outputs.
  2. Check the external commands in the Inputs unit of the vacuum pop-up (Tool Settings > Cycle Settings).

Remedy: select the commands again or Select Signal if they are not required, then save (Save Changes).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T03004-0.XX - Vacuum - Input vacuum not configured

What this means: the tool is using vacuum XX, which is present on the machine but for which the vacuum switch input has not been enabled: the vacuum cannot be controlled. The input is configured in the Tool tab under Machine Settings > General Settings > Components, a CEMAS setting. A vacuum that is not present on the machine does not trigger an alarm. In the code, XX is the vacuum number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The vacuum valve is closed.

Probable causes:

  • Vacuum switch input not configured (Set inputs);
  • Tool using a vacuum not provided for on this machine.

How to resolve:

  1. Check in Equipment Settings > Actuators and Presences, under the Vacuum tab, that vacuum XX is required; if it is not required, delete it and save.
  2. If it is required, have the vacuum switch input configured (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Set up the inputs

How to recognise it: the ‘Vacuum input not configured’ alarm appears as soon as the tools use vacuum.

Check:

  1. Check in Equipment Settings > Actuators and Presences, under the Vacuum tab, that the tool is set to use vacuum XX.
  2. If it is not required, remove it from the tool and save.

Remedy: if the vacuum is required, the vacuum switch input must be configured in the Equipment tab under Machine Settings > General Settings > Components by a CEMAS technician.

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T03005-0.XX – Vacuum – Vacuum loss

What this means: a vacuum was automatically established but was lost whilst the valve was still open. Control is suspended whilst the machine awaits loading or the start of the cycle. In the code, XX is the vacuum number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The valve remains open.

Probable causes:

  • workpiece displaced or detached (Object incorrectly positioned);
  • leaks or damaged suction cups (Check grip, Pneumatic check);
  • vacuum switch out of calibration (Sensors not working).

How to resolve:

  1. Reposition the workpiece.
  2. Select Vacuum in Machine Diagnostics > Manual Movements, Tools tab: the green ring must remain steady.
  3. If it goes out: check suction cups, fittings and vacuum switch (maintenance technician).

Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Check on withholding

How to recognise it: a vacuum is difficult to achieve, is lost shortly afterwards, or remains even after the valve is released.

Check:

  1. Check that the suction cups are undamaged, clean and not deformed.
  2. Check the vacuum lines and fittings: ensure no hoses are punctured, blocked or disconnected.
  3. Activate Vacuum and Blow from Machine Diagnostics > Manual Movements, under the Tools tab, whilst listening for any leaks.

Remedy: replace damaged suction cups or hoses and tighten the fittings (maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Item in the wrong place

How to recognise this: the vacuum is lost during the cycle because the workpiece has moved or is not seated properly.

Check:

  1. Check that the workpiece is in its correct position and is resting on all the suction cups.
  2. Check that no movement of the tools displaces it during the cycle.

Remedy: reposition the workpiece; if it always shifts at the same point in the cycle, have the tools checked (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Control inputs

Alarms relating to tool input controls – the input signals (buttons, pedals, Smart Tool signals) used in the cycle. These are configured under Equipment Settings > Actuators and Presences, on the Input Controls tab, which is visible in the advanced view.

T04000-0.XX - Control inputs - Incorrect signal address

What this means: the input command does not have a valid signal: in Plug mode, the pin does not exist on the plug; in Smart Tool mode, the selected signal is invalid (Equipment Settings > Actuators and Presences, Input Commands tab, Signal unit). In the code, XX is the input command number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • invalid pin or signal (Reset commands);
  • plug or Smart Tool different from those specified.

How to resolve:

  1. Select the command in Tool Settings > Actuators and Presences, under the Input Commands tab (visible in advanced view) and check the Mode.
  2. With Plug: assign the pin in the Input pop-up; with Smart Tool: select the signal from the Signal menu.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Reset the controls

How to recognise it: the input command does not have a valid pin or signal.

Check:

  1. Select the command in Equipment Settings > Actuators and Presence, under the Input Commands tab (visible in advanced view) and check the Mode of the Signal unit.
  2. With Plug: check the pin in the Input pop-up; with Smart Tool: check the selected signal.

Solution: assign a valid pin or signal, or delete the command if it is not needed, and save (Save changes).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Command outputs

Alarms for the tool output commands – the output signals sent to the tools used in the cycle. These are configured under Equipment Settings > Actuators and Presences, on the Output Commands tab, which is visible in the advanced view.

T05000-0.XX - Output signals - Incorrect signal address

What this means: with the Smart Tool connected, the output command has an unselected signal or one outside the range (1 to 20) (Equipment settings > Actuators and presences, Output commands tab, Signal unit). In the code, XX is the output command number (01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • invalid signal (Reset the commands).

How to resolve:

  1. Select the command in Equipment Settings > Actuators and Presences, Output Commands tab (visible in advanced view).
  2. Select the signal from the Signal menu or delete the command if it is not required.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.

Reset the controls

How to identify this: the output command does not have a valid signal from the Smart Tool.

Check:

  1. Select the command under Equipment Settings > Actuators and Presences, on the Output Commands tab (visible in the advanced view).
  2. Check the Signal menu: it must not display Select signal.

Remedy: select the correct signal, or delete the command if it is not needed, and save (Save changes).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Smart Tool

Smart Tool (intelligent tool) alarms: the tool has its own PLC that exchanges signals with the welding machine: no communication, PLC disconnected, incompatible versions.

Availability: Tool option: only available when a Smart Tool is loaded.

T06000-0.XX - Smart Tool - Communication alarm

What this means: the Smart Tool’s PLC is no longer exchanging data with the welding machine’s PLC.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • plug or cable disconnected (Smart Tool not connected);
  • Smart Tool switched off or not configured (Smart Tool PLC not configured).

How to resolve:

  1. Check that the Smart Tool plug is connected and that the Smart Tool is powered up.
  2. Check the Smart Tool’s communication LEDs.
  3. If the connection is correct, have the Smart Tool’s configuration checked (by a CEMAS technician).

Recovery: the fault clears automatically when the condition no longer exists; the Reset is also sent to the Smart Tool.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: tool option: only available when a Smart Tool is loaded.

Smart Tool not connected

How to tell: the Smart Tool is not communicating: the communication LEDs are off and the Smart Tool System icon does not appear in the bottom bar.

Check:

  1. Check that the Smart Tool’s plug is fully inserted.
  2. Check the power supply and the Smart Tool’s LEDs.
  3. Check that the cable is not damaged.

*Remedy*: Reconnect or replace the cable (by a maintenance technician); if the Smart Tool is powered up and connected but is not communicating, see Smart Tool PLC not configured**.

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.
Smart Tool PLC not configured

How to identify the problem: the Smart Tool is connected and powered but communication cannot be established.

Check:

  1. Check that the Smart Tool fitted is the one intended for the loaded tool.
  2. Note any error status indicated by the LEDs on the Smart Tool’s PLC.

Remedy: the Smart Tool’s PLC is configured by connecting directly to its PLC, not via the control panel: contact CEMAS Elettra S.r.l. support (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T06001-0.XX - Smart Tool - Offline

What this means: The welding machine’s PLC does not detect the connected Smart Tool.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • plug or cable disconnected (Smart Tool not connected);
  • Smart Tool not powered.

How to resolve:

  1. Plug the Smart Tool’s connector in fully and check that it is powered.
  2. Check that the communication LEDs light up.

Recovery: the fault clears automatically once the condition no longer exists; a Reset is also sent to the Smart Tool.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: tool option: only available when a Smart Tool is loaded.

Smart Tool not connected

How to tell: the Smart Tool is not communicating: the communication LEDs are off and the Smart Tool System icon does not appear in the bottom bar.

Check:

  1. Check that the Smart Tool’s plug is fully inserted.
  2. Check the power supply and the Smart Tool’s LEDs.
  3. Check that the cable is not damaged.

*Remedy*: Reconnect or replace the cable (by a maintenance technician); if the Smart Tool is powered up and connected but is not communicating, see Smart Tool PLC not configured**.

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T06002-0.XX - Smart Tool - Unsupported version of SmartTool

What this means: the version of the Smart Tool programme is not supported by the welding machine’s software.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • Smart Tool programme is not compatible (Smart Tool update).

How to resolve:

  1. Note down the PLC release in Machine diagnostics > Support.
  2. Request a Smart Tool update (CEMAS technician).

Resolution: the issue resolves itself once the condition no longer exists; the Reset is also sent to the Smart Tool.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: tool option: only available when a Smart Tool is loaded.

Smart Tool Update

How to recognise it: a ‘version not supported’ warning appears (for the Smart Tool or the machine).

Check:

  1. Note down the PLC release under Machine Diagnostics > Support.
  2. Note down the Smart Tool programme version, if indicated on the Smart Tool or in its documentation.

Remedy: request a software update for the machine or the Smart Tool from CEMAS Elettra support (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T06003-0.XX - Smart Tool - Machine version not supported

What this means: The Smart Tool does not accept the welding machine’s software version.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Possible causes:

  • machine software is older than required (Smart Tool update).

How to resolve:

  1. Note down the PLC release in Machine diagnostics > Support.
  2. Request a machine or Smart Tool update (CEMAS technician).

Resolution: the issue resolves itself when the condition no longer exists; the Reset is also forwarded to the Smart Tool.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: tool option: only available when a Smart Tool is loaded.

Smart Tool Update

How to recognise it: a ‘version not supported’ warning appears (for the Smart Tool or the machine).

Check:

  1. Note down the PLC release under Machine Diagnostics > Support.
  2. Note down the Smart Tool programme version, if indicated on the Smart Tool or in its documentation.

Remedy: request a software update for the machine or the Smart Tool from CEMAS Elettra support (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Tool status

Alarms relating to the general status of the tools: parameters that have been modified but not saved; an identification code read from the plug that differs from that of the loaded tools; head or mirror codes that differ from those of the table; plus some internal summaries not displayed in the Alarm Monitor.

T07000-0.XX - Tool status - Presences

What this means: internal PLC summary, active when at least one of the tool presence indicators is in alarm.

Effect: alert not displayed in the Alarm Monitor: none in itself: the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.

T07001-0.XX – Tool status – Actuators

What this means: internal PLC summary, active when at least one of the tools’ actuators is in alarm.

Effect: notification not displayed in the Alarm Monitor: none in itself: the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.

T07002-0.XX - Tool status - Vacuum

What this means: internal PLC summary, active when at least one of the tools’ vacuums is in alarm.

Effect: alert not displayed in the Alarm Monitor: none in itself: the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.

T07003-0.XX - Tool status - Input controls

What this means: internal PLC summary, active when at least one of the tools’ input commands is in alarm.

Effect: a message not displayed in the Alarm Monitor: none in itself; the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.

T07004-0.XX – Tool status – Output commands

What this means: internal PLC summary, active when at least one of the tools’ output commands is in alarm.

Effect: a message not displayed in the Alarm Monitor: none in itself: the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.

T07005-0.XX - Tool status - Smart Tool

What this means: internal PLC summary, active when at least one of the tools is in alarm.

Effect: notification not displayed in the Alarm Monitor: none in itself: the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.

T07006-0.XX - Tool status - Changes to tools to be saved

What this means: the parameters for the loaded tools have been changed but not yet saved; the Save changes button appears in the top panel. This control is not active in Putting into service or Configuration mode.

Effect: Alarm (red line): the automatic cycle cannot be started.

Possible causes:

  • Parameters have been changed in Tool settings (Save changes).

How to resolve:

  1. Check the changes and tap Save changes: this opens Tool Change > Product Selection, from where you can save.
  2. To undo the changes, reload the tools from the same page.

Resolution: the issue resolves itself after saving or reloading.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Save changes

How to recognise it: the Save changes button is located in the top bar.

Check:

  1. Tap Save changes: this opens Tool change > Product selection.
  2. Check that the changes are as intended.

Solution: save the parameters; to discard the changes, reload the tools from the same page.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T07007-0.XX - Tool status - ID code error on tool shank

What this means: outside of the tool change cycle, the code read from the plug’s coding pins differs from that of the loaded tool: the tool fitted may not correspond to the parameters currently in use.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • plug not fully inserted or dirty contacts (Check plug);
  • tool replaced without performing a tool change;
  • coding pins incorrectly wired.

How to resolve:

  1. Check that the tool fitted is the one indicated in the lower box; if it is different, perform a tool change.
  2. If it is the correct one: check the plug and the code read in Machine Diagnostics > PLC, under the Pin Decoding tab.
  3. If the code is incorrect: check the wiring of the coding pins (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the tools area, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Check the plug

How to identify the problem: the tool code read from the plug does not match the tool loaded.

Check:

  1. Check that the tool plug is fully inserted and that the contacts are clean.
  2. Read the code in Machine Diagnostics > PLC, under the Pin Decoding tab.
  3. Compare the wiring of the coding pins with the wiring diagram.

Remedy: reinsert the plug; correct the wiring of the encoding pins (maintenance technician).

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T07008-0.XX - Tool status - Head coding non-compliant

What this means: the code read on the head plug does not match the one read on the table: the parts fitted to the head and table do not belong to the same tool.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • the upper part of a different set of tools is fitted to the head;
  • the head connector is not inserted or the coding pins are wired incorrectly.

How to resolve:

  1. Check that the head and table are fitted with parts from the same tool set.
  2. Check the head connector and the code read in Machine Diagnostics > PLC, under the Pin Decoding tab.
  3. If the code is incorrect: check the wiring of the encoding pins (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

T07009-0.XX – Tool status – Mirror coding non-compliant

What this means: the code read on the mirror plug does not match the one read on the table: the mirror fitted does not belong to the same tool.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • a mirror from another tool has been fitted;
  • the mirror connector is not inserted or the coding pins are incorrectly wired.

How to resolve:

  1. Check that the mirror and table belong to the same tools.
  2. Check the mirror connector and the code read in Machine Diagnostics > PLC, Pin Decoding tab.
  3. If the code is incorrect: check the wiring of the encoding pins (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, ensure the machine is safely shut down in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

Machine Alarms

Machine Alarms relate to the welding machine: power supplies and utilities (air, electric panel, pumps, extraction), axes and drives, tooling interfaces on the head, table and mirrors, safety devices, automatic and tool change cycles, vibration generators, laser sources, infrared or hot plate heating, and cooling. The code begins with M and the text in Machine Status > Alarm Monitor begins with Machine, followed by the zone (Head, Table, Mirror, Right Mirror) when the alarm relates to a specific zone.

Many units exist only for certain technologies or with certain machine options: each entry indicates this in the Availability paragraph.

Pressure switch

Alarms from the pressure switch on the main compressed air line, which monitors the supply pressure to the pneumatic actuators of the machine and tools. This is configured under Machine Settings > General Settings > Components, on the Pressure Switch tab.

M01000-0.XX - Pressure switch - No air

What this means: once the emergency has been reset, the main line pressure switch does not signal the pressure for approximately 3 s (fixed value). The threshold is set on the pressure switch (usually 5 bar).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. Without air, the pneumatic actuators are not controlled.

Probable causes:

  • mains air supply shut off or absent (No air in the system);
  • filter regulator closed, faulty or set too low (Filter regulator not supplied with air);
  • inlet solenoid valve not actuated (Pilot-operated solenoid coil);
  • pressure switch out of calibration or faulty.

How to resolve:

  1. Check that the machine’s air valve is open and that the mains supply is under pressure.
  2. Read the pressure gauge on the regulating filter: if the pressure is below the threshold, adjust the filter (maintenance technician).
  3. If the pressure is correct, check the inlet solenoid valve and pressure switch (by a maintenance technician).

Reset: once the cause has been rectified, press Reset on the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the pressure switch is fitted (Machine settings > General settings > Components, Pressure switch tab), option configured by CEMAS.

No air in the system

How to identify it: the machine’s pressure gauge shows zero or very low pressure; the pneumatic actuators do not move.

Check:

  1. Check that the machine’s air supply valve is open.
  2. Check that the factory air supply network is pressurised and that the supply hose is connected.

Remedy: open the valve or restore the supply (maintenance technician or the plant’s compressed air service).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Intervention by a maintenance technician.
Filter regulator not charged with air

How to identify this: air is reaching the machine, but the pressure gauge downstream of the regulator filter indicates low pressure.

Check:

  1. Read the pressure gauge on the regulator filter.
  2. Check the setting and condition of the filter cartridge and drain any condensation.

Remedy: adjust the pressure, clean or replace the cartridge; if the regulator is faulty, replace it (by a maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Controlled electric coil

How to identify the fault: the air supply valve does not open: no pressure reaches the downstream side even when mains air is present.

Check:

  1. Check that the PLC is controlling the valve (output active in Machine Diagnostics > PLC, Card Monitoring tab).
  2. Check the LED on the solenoid connector for the controlled valve.
  3. Check the voltage across the solenoid and the wiring.

Remedy: replace the connector or solenoid; if the solenoid is energised but the valve does not open, replace the valve (by a maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance by a qualified maintenance technician.
Warning Resetting and measurements in the electric panel must be carried out by qualified personnel, with the machine secured in accordance with the user manual.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M01001-0.XX - Pressure switch - Safety inputs not present

What this means: the two-channel safety pressure switch is sending signals of an inconsistency: the two channels are out of sync for 500 ms, or the first channel is open whilst the emergency has been reset.

Effect: Alarm (red line): the machine switches to manual mode; automatic cycle and tool change remain blocked.

Probable causes:

  • insufficient or unstable air pressure;
  • one channel of the pressure switch faulty or disconnected;
  • wiring between the two inputs broken.

How to resolve:

  1. Check the pressure and stability of the supply air.
  2. Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the two pressure switch inputs light up simultaneously.
  3. If only one input switches: check the wiring and the pressure switch (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Warning Before opening the electric panel, secure the machine in accordance with the user manual. Work to be carried out by qualified personnel only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the safety pressure switch is fitted (Machine settings > General settings > Components, Pressure switch tab), an option configured by CEMAS.

Air conditioner

Alarms for the electric panel air conditioners (up to three), which maintain the internal temperature of the panel within the limits specified for the components. These are configured under Machine Settings > General Settings > Components, on the Air Conditioners tab.

M02000-0.XX - Air conditioner - Alarm

What this means: The air conditioner in the electric panel is signaling its own alarm (alarm contact open), for example due to high temperature or a fault. The control is active whilst the emergency condition has been resolved. In the code, XX is the air conditioner number (from 01 to 03).

Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle. It remains stored.

Probable causes:

  • fault or alarm in the air conditioner (Alarm code);
  • clogged filters or high ambient temperature;
  • control panel doors open.

How to resolve:

  1. Read the alarm code on the air conditioning unit’s display and consult the manual.
  2. Check that the control panel doors are closed and that the vents are not blocked.
  3. Clean the filters (by a maintenance technician).

Reset: once the cause has been rectified, press Reset on the Alarm Monitor.

Safety:

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation is reserved for qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the air conditioner is fitted (Machine settings > General settings > Components, Air conditioners tab), option configured by CEMAS.

Alarm code

How to identify it: the component (e.g. air conditioner, heat exchanger, generator or UPS) displays an error code on its screen or via its LEDs.

Check:

  1. Read the code on the display or in the component’s diagnostics.
  2. Look up the meaning of the code in the component’s manual.

Remedy: carry out the actions indicated in the component manual (by a maintenance technician); if the error code persists, report it to CEMAS Elettra S.r.l. support.

Warning Before opening the electric panel, secure the machines in accordance with the user manual. This work must only be carried out by qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M02001-0.XX - Air conditioner - Breaker triggered

What this means: the circuit board’s air conditioning protection switch is open: the air conditioning unit is not receiving power. The control is active with the emergency mode reset. In the code, XX is the air conditioning unit number (from 01 to 03).

Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic cycle. It remains stored in memory. Without cooling, the control panel may overheat.

Probable causes:

  • circuit breaker tripped due to overload or fault (Circuit breaker (thermal) tripped);
  • cabinet doors open (Door closure);
  • door closure sensor faulty (Door closure sensor function).

How to resolve:

  1. Check that the control panel doors are closed.
  2. Reset the air-conditioning circuit breaker and check that it does not trip again (maintenance technician).
  3. If it trips again, have the air-conditioning unit checked (maintenance technician).

Restoration: once the cause has been rectified, press Reset on the Alarm Monitor.

Safety:

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation is reserved for qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the air conditioner is fitted (Machine settings > General settings > Components, Air conditioners tab), option configured by CEMAS.

Door closing

How to identify this: the doors of the electric panel are open or ajar.

Check:

  1. Visually check that all the panel doors are closed and locked.

Remedy: close the panel doors; if the doors are open, the panel’s cooling system will not function correctly.

Circuit breaker (thermal) has tripped

How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.

Check:

  1. Locate the component’s circuit breaker on the wiring diagram and check its position.
  2. Check that the thermal setting corresponds to the diagram.
  3. Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.

Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Door closure sensor function

How to identify the problem: the control cabinet doors are closed, but the machine detects them as open.

Troubleshooting:

  1. Check the position and fixing of the control cabinet door closure sensor.
  2. Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the sensor input changes state when the door is opened and closed.

Remedy: reposition or replace the sensor (maintenance technician).

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation must only be carried out by qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Electric panel thermostat

Alarms from the electric panel thermostats (up to three), which signal that the internal temperature of the panel exceeds the temperature set on the thermostat. These are configured under Machine settings > General settings > Components, on the Electric panel thermostat tab.

M03000-0.XX – Electric panel thermostat – Alarm

What this means: The thermostat in the electric panel is signaling an internal temperature higher than that set on the thermostat. The control is active with the operator’s safety devices reset. In the code, XX is the thermostat number (from 01 to 03).

Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle. It remains stored in memory. A high temperature may cause faults in the electronic components.

Probable causes:

  • Insufficient cabinet cooling or a fault (Cooling system);
  • Thermostat set too low or faulty (Thermostat setting);
  • Cabinet doors open or high ambient temperature.

How to resolve:

  1. Check that the cabinet air conditioner or fans are working and that the filters are clean (maintenance technician).
  2. Check that the cabinet doors are closed.
  3. Check the temperature set on the thermostat (maintenance technician).

Reset: once the cause has been rectified, press Reset on the Alarm Monitor.

Safety:

Warning Before opening the electric panel, ensure the machine is safely shut down in accordance with the user manual. This operation is reserved for qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the thermostat is fitted (Machine settings > General settings > Components, Electric panel thermostat tab), an option configured by CEMAS.

Cooling system

How to tell: the electric panel is hot and the air conditioner or fans are not blowing cool air.

Check:

  1. Check that the air conditioning or fans in the switchboard are switched on.
  2. Check the filters and ventilation grilles.
  3. Check for any alarms on the air conditioning display.

Remedy: clean or replace the filters; have the faulty cooling system repaired (by a maintenance technician).

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This work must only be carried out by qualified personnel.
Thermostat settings

How to identify the problem: the thermostat trips when the cabinet is at normal temperature.

Check:

  1. Check the temperature setting on the cabinet thermostat.
  2. Compare it with the value shown in the wiring diagram.

Remedy: adjust the thermostat to the correct value; if it tripped anyhow, replace it (by a maintenance technician).

Warning Before opening the electric panel, ensure the machines are safely shut down in accordance with the user manual. This work must only be carried out by qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

IM device status

Alarms from the IM interface modules, which connect the PLC to the input and output cards. The status of the cards can be viewed under Machine Diagnostics > PLC, on the PLC Hardware tab.

M04000-0.XX - IM device status - Device not configured

What this means: the IM interface module that connects the PLC to the input and output cards is not configured. On laser machines, there are up to three modules (XX from 01 to 03); on other machines, only IM1 is present. The cards can be viewed under Machine Diagnostics > PLC, on the PLC Hardware tab.

Effect: Alarm (red line): with the IM1 module, the machine switches to manual mode; the automatic cycle and tool change remain blocked. For IM2 and IM3, this is merely a warning.

Probable causes:

  • PLC configuration does not match the installed modules (Configure IM);
  • module replaced with a different model.

How to resolve:

  1. Check the status of the module cards in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. If a module has been replaced, check that the model is identical (maintenance technician).
  3. Have the PLC configuration checked (CEMAS technician).

Reset: disappears automatically when the condition no longer exists.

Safety:

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation is reserved for qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Set up IM

How to identify the problem: the IM module appears as unconfigured even though it is installed and powered.

Check:

  1. Check the module’s cards in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Check that the installed module is the same model as specified in the configuration.

Remedy: the PLC configuration can only be updated by CEMAS Elettra S.r.l. personnel: contact support (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M04001-0.XX - IM device status - Device not accessible

What this means: the PLC is unable to communicate with the IM interface module. As the module is unreachable, input diagnostics are suspended; therefore, the warning may not appear even if a fault is present: this status can be viewed under Machine Diagnostics > PLC, in the PLC Hardware tab.

Effect: Alarm (red line): with the IM1 module, the machine switches to manual mode; the automatic cycle and tool change remain blocked. For IM2 and IM3, this is merely an indication.

Probable causes:

  • Network cable between the PLC and the module is disconnected or damaged (Connect IM);
  • Module is not powered.

How to resolve:

  1. Check for error cards (red exclamation mark) in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Check the module’s power supply and LEDs, and the network cable (maintenance technician).

Resolution: the error disappears automatically once the condition no longer exists.

Safety:

Warning Before opening the electric panel, secure the machine in accordance with the user manual. Work to be carried out by qualified personnel only.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.

Connect IM

How to identify the problem: the IM module is not communicating: network LEDs are off or red, and there are error messages for the cards on the PLC Hardware page.

Check:

  1. Check that the network cable between the PLC and the module is connected.
  2. Check the module’s power supply (power LEDs should be on).

Remedy: Reconnect or replace the cable; restore the power supply (by a maintenance technician).

Warning Before opening the electric panel, ensure the machine is safely shut down in accordance with the user manual. This operation must only be carried out by qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M04002-0.XX - IM device status - Hardware error

What this means: the IM interface module is signalling a hardware fault, either in the module itself or in a connected card. When the module is in fault mode, input diagnostics are suspended, so the fault message may not appear: the status can be checked under Machine Diagnostics > PLC, on the PLC Hardware tab.

Effect: Alarm (red line): with the IM1 module, the machine switches to manual mode; the automatic cycle and tool change remain blocked. For IM2 and IM3, this is merely a warning.

Probable causes:

  • Faulty module or card, or not inserted correctly (Check hardware).

How to resolve:

  1. In Machine Diagnostics > PLC, on the PLC Hardware tab, identify the card marked with a red exclamation mark.
  2. Check that the card is fully inserted into its socket (maintenance technician).
  3. If the fault persists, replace the card with one of the same model (maintenance technician) and notify CEMAS.

Reset: the fault clears automatically once the condition no longer exists.

Safety:

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation is reserved for qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Check the hardware

How to identify it: an IM module card displays a red exclamation mark under Machine Diagnostics > PLC, on the PLC Hardware tab.

Check:

  1. Check that the card is fully inserted into its socket.
  2. Move the card to another free position to determine whether the card or the socket is faulty.

Remedy: replace the card or socket with components of the same model (maintenance technician) and notify CEMAS Elettra support.

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation is reserved for qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Time zone

Machine time alerts: time zone not set or PLC clock not synchronised. The time zone is set via Date and time in the bottom pane (Time zone pop-up).

M05000-0.XX - Time zone - Time zone not selected

What this means: the machine’s time zone is not set or is invalid: the date and time of recorded events (cycles, alarms) may be incorrect.

Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • Time zone not selected after installation or an update (Time zone setting).

How to resolve:

  1. Tap Date and time in the bottom panel (Time zone pop-up) and select the time zone for the installation location (users authorised to manage the machine or tools).
  2. Confirm and check that the time displayed is correct.

Resolution: the issue resolves itself once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Setting the time zone

How to recognise it: the date and time displayed in the bottom bar do not match the local time.

Check:

  1. Tap Date and time in the bottom frame (Time zone pop-up) and check the set time zone.

Solution: select the time zone for the installation location and confirm (users authorised to manage the machine or tools).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M05001-0.XX – Time zone – Time synchronisation error

What this means: with synchronisation monitoring enabled (CEMAS setting), the PLC’s clock has been out of sync for at least 1 hour. The time source (network server or operator panel) depends on the PLC’s configuration; the PLC does not adjust the time itself.

Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • Time server unreachable or company network disconnected;
  • Time zone not set (Time zone setting);
  • Incorrect synchronisation configuration.

How to resolve:

  1. Check the time zone via Date and Time in the bottom pane (Time Zone pop-up).
  2. Check that the machine’s network cable is connected and that the company’s time server is active (customer’s IT department).
  3. If the network connection is correct, have the configuration checked (CEMAS technician).

Resolution: the error disappears automatically once the issue is resolved.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Setting the time zone

How to recognise it: the date and time displayed in the bottom bar do not match the local time.

Check:

  1. Tap Date and time in the bottom frame (Time zone pop-up) and check the set time zone.

Solution: select the time zone for the installation location and confirm (users authorised to manage the machine or tools).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Signal tower

Alarms from the machine’s stack light. This is configured under Machine Settings > General Settings > Components, on the Signal Column tab.

M06000-0.XX – Signal tower – Patlite communication error

What this means: The stack light is not communicating with the PLC via the network.

Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle. The stack light does not display the machine’s status.

Probable causes:

  • the stack light’s network or power cable is disconnected (Stack light connection);
  • the stack light is faulty (Stack light functionality).

How to resolve:

  1. Check that the signal tower is powered (indicator lights on at start-up).
  2. Check the signal tower’s mains cable and its connectors (maintenance technician).
  3. If the connection is correct, replace the tower (maintenance technician).

Resolution: the fault clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the stack light is fitted (Machine settings > General settings > Components, Signal column tab), an option configured by CEMAS.

Stack light functions

How to identify the problem: the turret is powered up and connected but does not switch on or communicate.

Check:

  1. Check the turret’s status LEDs.
  2. Temporarily replace the network cable with a working one.

Remedy: if the turret remains unresponsive, replace it (by a maintenance technician).

Stack light connection

How to recognise this: the turret is switched off or is not communicating following work carried out on the machine.

Check:

  1. Check the turret’s power cable.
  2. Check the network cable and its connectors.

Remedy: Reconnect or replace any damaged cables (by a maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

General signal

General signal alarms: signals with a fixed function (clamp, alarm reset, cycle start, home position, pressure switch, presences, out-of-limit, external manual/automatic), often used to connect the welding machine to a production line or a robot. These are configured under Machine Settings > General Settings > Components, on the General Signals tab.

M07000-0.XX – General signal – Incorrect command address

What this means: the general signal XX is assigned to an input command that does not exist (number outside the range 1–20) or is not enabled, for example, one that has been deleted after assignment; the signal remains at its last value. XX: 01 Clamp, 02 External clamp, 03 Reset alarms, 04 Start cycle, 05 Start cycle external, 06 Home position, 07 Pressure switch, 08 LH presence, 09 RH presence, 10 Out of clearance, 11 external manual/automatic.

Effect: Alarm (red line): for signals 01 to 09, the machine switches to manual mode; the automatic cycle and tool change remain blocked. For 10 and 11, it is merely an indication.

Probable causes:

  • Input command deleted or disabled after assignment (Reset command).

How to resolve:

  1. Check the command assigned to signal XX in Machine Settings > General Settings > Components, under the General Signals tab.
  2. Check in Machine Settings > General Settings > Components, under the Input Commands tab, that the command exists and is enabled.
  3. Correct the assignment (CEMAS technician).

Reset: stored: after correction, press Reset in the Alarm Monitor; if the cause remains, the fault will recur.

Safety:

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Reset command

How to recognise it: the alarm appears after modifying or deleting machine input commands.

Check:

  1. Check in Machine Settings > General Settings > Components, under the General Signals tab, the command assigned to the signal indicated by XX.
  2. Check in Machine Settings > General Settings > Components, under the Input Commands tab, that the command exists and is enabled.

Remedy: correct the assignment (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Suction

Warnings relating to the extractor fan for welding fumes. This is configured under Machine settings > General settings > Components, on the Extractor fan tab.

M08000-0.XX - Suction - Breaker triggered

What this means: the fume extractor’s safety switch is open.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked. The fume extraction is switched off.

Probable causes:

  • motor overload or fault, blocked filters (Circuit breaker (thermal) tripped).

How to resolve:

  1. Check the condition of the extractor filters and clean or replace them (maintenance technician).
  2. Reset the circuit breaker and check that it does not trip again (maintenance technician).
  3. If it trips again, have the extractor motor checked (maintenance technician).

Restoration: once the cause has been rectified, press Reset on the Alarm Monitor. On machines with vibration, the alarm may remain active after pressing Reset: in this case, contact CEMAS Elettra support.

Safety:

Warning Before opening the electric panel, secure the machines in accordance with the user manual. This operation must only be carried out by qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the extractor is fitted (Machine settings > General settings > Components, Extractor tab), an option configured by CEMAS.

Circuit breaker (thermal) has tripped

How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.

Check:

  1. Locate the component’s circuit breaker on the wiring diagram and check its position.
  2. Check that the thermal setting corresponds to the diagram.
  3. Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.

Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

VCU

Alarms from the VCU (Vibration Control Unit), the generator that controls the vibration of the head and communicates with the PLC via a serial link: communication, safety switch, readiness, vibration duration and amplitude, amplitude calibration.

The VCU parameters (maximum amplitude, tolerance, vibration time-out) are found under Machine Settings > General Settings > Tool Interfaces, VCU tab; the vibration can be tested via Machine Diagnostics > Machine Test, VCU tab; the results of the amplitude tests are found in Machine Diagnostics > Calibrations and Certifications, VCU tab.

Availability: only on vibration machines.

VCU Amplitude Meter

Alarms from the amplitude metre, the networked measuring instrument that detects the amplitude of the head’s vibration during VCU calibration, certification and capability testing. It is triggered only during these procedures: its alarms do not appear during production.

Availability: only on vibrating machines.

Centering

Alarms relating to centerings – the pneumatic devices that center the tools on the head, table or faceplate: movements not completed within the expected time, inconsistent position sensors, simultaneous commands.

Centreing devices are configured under Machine Settings > General Settings > Tool Interfaces, in the zone tab, under the Centerings tab; they are operated manually via Tool Change > Tool Change, in the Manual tab > Centerings, whilst the machine is in tool change mode.

M11000-2.XX - Table - Centering - Forward movement timeout

What this means: Following the command to move to the forward position, the sensor for that table centering position did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Centerings tab (−1 disables the check). The centering mechanism only moves outside the automatic cycle, with the emergency stops released.

Effect: Alarm (red line): the valves de-energise and the device remains stationary where it is; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or valve failing to switch;
  • forward position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Centering (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if centering is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise this: the centering does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the centering completes the movement, but with a delay compared to the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine settings > General settings > Tool interfaces, zone tab, Centering tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M11000-3.XX - Mirror (rear/left) - Centering - Forward movement timeout

What this means: Following the command to move to the forward position, the sensor for that mirror centering position did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Centerings tab (−1 disables the check). The centering mechanism only moves outside the automatic cycle, with the emergency stops released.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or valve failing to switch;
  • forward position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Centerings (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Timeout checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if centering is fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise this: the centering does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the centering completes the movement, but with a delay compared to the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine settings > General settings > Tool interfaces, zone tab, Centering tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M11001-3.XX - Mirror (rear/left) - Centering - Backward movement timeout

What this means: Following the command to move to the retraction position, the sensor for that mirror centering position did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Centerings tab (−1 disables the check). The centering mechanism only moves outside the automatic cycle, with the emergency stops released.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or valve failing to switch;
  • rear position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Centering (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Timeout checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if centering is fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the centering does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the centering completes the movement, but with a delay compared to the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine settings > General settings > Tool interfaces, zone tab, Centering tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M11001-2.XX - Table - Centering - Backward movement timeout

What this means: Following the command to move to the retraction position, the sensor for that table centering position did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Centerings tab (−1 disables the check). The centering mechanism only moves outside the automatic cycle, with the emergency stops released.

Effect: Alarm (red line): the valves de-energise and the device remains stationary where it is; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or valve failing to switch;
  • rear position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Centering (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if centering is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the centering does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the centering completes the movement, but with a delay compared to the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine settings > General settings > Tool interfaces, zone tab, Centering tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M11002-3.XX – Mirror (rear/left) – Centering – Forward position not released

What this means: Following the command to move to the ‘back’ position, once the Time out has elapsed, the ‘forward’ position sensor for mirror centering is still active: either the device has not started, or the sensor remains active.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • forward position sensor always active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centering (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the forward position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if centering is fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Centering lock engaged

How to recognise it: the centering does not start when commanded or stops halfway through its stroke; the start position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the travel (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M11002-2.XX - Table - Centering - Forward position not released

What this means: Following the command to move to the ‘back’ position, when the Time out expires, the ‘forward’ position sensor for the table centering is still active: either the device has not started, or the sensor remains active.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • forward position sensor always active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the forward position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if centering is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Centering lock engaged

How to recognise it: the centering does not start when commanded or stops halfway through its stroke; the start position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the travel (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M11003-3.XX - Mirror (rear/left) - Centering - Rear position not released

What this means: Following the command to move forwards, when the Time out expires, the sensor for the rear position of the mirror centering is still active: the device has not started, or the sensor remains on.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • rear position sensor always active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the reverse position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if centering is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Centering lock engaged

How to recognise it: the centering does not start when commanded or stops halfway through its stroke; the start position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the travel (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M11003-2.XX - Table - Centering - Rear position not released

What this means: Following the command to move forwards, when the Time-out expires, the sensor for the table’s rear centering position is still active: the device has not started, or the sensor remains on.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • rear position sensor always active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the reverse position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if centering is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Centering lock engaged

How to recognise it: the centering does not start when commanded or stops halfway through its stroke; the start position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the travel (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M11004-3.XX – Mirror (rear/left) – Centering – External alarm

What this means: A warning is provided for an external mirror centering alarm. In current versions of the machine software, the warning is provided but is not triggered.

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if centering is fitted; option configured by CEMAS.

M11004-2.XX - Table - Centering - External alarm

What this means: A warning is provided for an external table-centering alarm. In current versions of the machine software, the warning is provided but is not triggered.

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if centering is present; option configured by CEMAS.

M11005-2.XX - Table - Centering - Both position sensors

What this means: The forward and reverse position sensors for table centering are active at the same time: the position cannot be determined. Control is always active when the device is present.

Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a faulty or short-circuited sensor, which is always active;
  • sensors positioned so as to detect both positions;
  • sensor inputs configured incorrectly.

How to resolve:

  1. With the device stopped, check under Machine Diagnostics > PLC, on the Card Monitoring tab, which of the two inputs is active for no reason.
  2. Control the device via Tool Change > Tool Change, Manual tab > Centering (In, Out): each sensor must light up only in its own position; reposition or replace the one that remains lit (maintenance technician).
  3. If the sensors are working, have the inputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Centering tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if centering is present; option configured by CEMAS.

Sensor positioning

How to identify this: the component’s two position sensors are active at the same time.

Check:

  1. Move the component to one position and check that only the LED for the corresponding sensor is lit.
  2. Repeat in the other position.
  3. Check that each sensor is securely fitted and detects only its own position.

Remedy: reposition or replace the sensor that remains active (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M11005-3.XX – Mirror (rear/left) – Centering – Both position sensors

What this means: The forward and reverse position sensors for mirror centering are active simultaneously: the position cannot be determined. Monitoring is always active when the device is present.

Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a faulty or short-circuited sensor, which is always active;
  • sensors positioned so as to detect both positions;
  • sensor inputs configured incorrectly.

How to resolve:

  1. With the device stopped, check under Machine Diagnostics > PLC, on the Card Monitoring tab, which of the two inputs is active for no reason.
  2. Control the device via Tool Change > Tool Change, Manual tab > Centering (In, Out): each sensor must light up only in its own position; reposition or replace the one that remains lit (maintenance technician).
  3. If the sensors are working, have the inputs checked in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Centering tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if centering is fitted; option configured by CEMAS.

Sensor positioning

How to identify this: the component’s two position sensors are active at the same time.

Check:

  1. Move the component to one position and check that only the LED for the corresponding sensor is lit.
  2. Repeat in the other position.
  3. Check that each sensor is securely fitted and detects only its own position.

Remedy: reposition or replace the sensor that remains active (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M11006-2.XX - Table - Centering - Both commands

What this means: The two valves controlling the table’s centering movement are being actuated simultaneously: either due to a manual command issued during a cycle movement, or because the outputs have been configured incorrectly.

Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a manual command given at the same time as a cycle command;
  • the same output assigned to both movements.

How to resolve:

  1. Press Reset and repeat the movement using only one command at a time.
  2. If the alarm reoccurs, have the valve outputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Centering tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if centering is present; option configured by CEMAS.

Reset the controls

How to recognise it: the component receives the two opposing commands simultaneously (for example, forwards and backwards).

Check:

  1. Check the outputs and commands assigned to the component under Machine Settings > General Settings > Tool Interfaces.
  2. Check that two different commands do not use the same output or the same signal.

Remedy: correct the configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M11006-3.XX – Mirror (rear/left) – Centering – Both commands

What this means: The two valves controlling the mirror centering movement are being actuated simultaneously: either due to a manual command issued during a cycle movement, or because the outputs have been configured incorrectly.

Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a manual command given at the same time as a cycle command;
  • the same output assigned to two movements.

How to resolve:

  1. Press Reset and repeat the movement using only one command at a time.
  2. If the alarm reoccurs, have the valve outputs checked in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Centerings tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if centering is fitted; option configured by CEMAS.

Reset the controls

How to recognise it: the component receives the two opposing commands simultaneously (for example, forwards and backwards).

Check:

  1. Check the outputs and commands assigned to the component under Machine Settings > General Settings > Tool Interfaces.
  2. Check that two different commands do not use the same output or the same signal.

Remedy: correct the configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Actuator connector

Alarms relating to connectors – the actuators that engage and disengage the automatic connection plug between the welding machine and the tools: incomplete movements, inconsistent sensor readings, simultaneous commands, unlocking required whilst the plug is engaged.

The connectors are configured in Machine Settings > General Settings > Tool Interfaces, under the zone tab, Connectors tab; they are controlled manually via Tool Change > Tool Change, under the Manual tab > Connectors.

M12000-1.XX - Head - Actuator connector - Forward movement timeout

The time within which the forward movement of the actuator that moves the automatic connection plug must be completed has been exceeded.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the connector does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the connector completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, connectors tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12000-2.XX - Table - Actuator connector - Forward movement timeout

What this means: Following the command to move to the forward position, the sensor for that position on the table connector did not activate within the Time-out set in Machine Settings > General Settings > Tool Interfaces, Table tab, Connectors tab (−1 disables the check). The connector only moves during tool change, with the operator safety devices in place; typical time-out is 5 seconds (s). In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • forward position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Connectors (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the connector is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the connector does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the connector completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, connectors tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12000-3.XX - Mirror (rear/left) - Actuator connector - Forward movement timeout

What this means: Following the command to move to the forward position, the sensor for that position on the mirror connector did not activate within the Time-out set in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Connectors tab (−1 disables the check). The connector only moves during tool change, with the operator safety devices in place; typical time-out is 5 seconds (s). In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • forward position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Connectors (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the connector is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the connector does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the connector completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, connectors tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12001-2.XX - Table - Actuator connector - Backward movement timeout

What this means: Following the command to move to the retraction position, the sensor for that position on the table connector did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Connectors tab (−1 disables the check). The connector only moves during tool change, with the operator safety devices in place; typical time-out is 5 seconds (s). In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • rear position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Connectors (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the connector is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the connector does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the connector completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, connectors tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12001-3.XX - Mirror (rear/left) - Actuator connector - Backward movement timeout

What this means: Following the command to move to the ‘back’ position, the sensor for that position on the mirror connector did not activate within the Time-out set in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Connectors tab (−1 disables the check). The connector only moves during tool change, with the operator safety devices in place; typical time-out is 5 seconds (s). In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • rear position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Connectors (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Timeout checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the connector is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the connector does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the connector completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, connectors tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12001-1.XX - Head - Actuator connector - Backward movement timeout

The time within which the backward movement of the actuator that moves the automatic connection plug must be completed has been exceeded.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the connector does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the connector completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, connectors tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12002-3.XX - Mirror (rear/left) - Actuator connector - Forward position not released

What this means: Following the command to move to the reverse position, when the Timeout expires, the forward position sensor of the mirror connector is still active: either the device has not started, or the sensor remains active. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • forward position sensor always active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the forward position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the connector is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Connection blocked

How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12002-2.XX - Table - Actuator connector - Forward position not released

What this means: Following the command to move to the reverse position, when the Timeout expires, the forward position sensor for the table connector is still active: either the device has not started, or the sensor remains active. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • forward position sensor always active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the forward position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the connector is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Connection blocked

How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12003-3.XX – Mirror (rear/left) – Actuator connector – Reverse position not released

What this means: Following the command to move forwards, when the Time out expires, the sensor for the reverse position of the mirror connector is still active: the device has not started, or the sensor remains active. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • ‘back’ position sensor constantly active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the reverse position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the connector is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Connection blocked

How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12003-2.XX - Table - Actuator connector - Reverse position not released

What this means: Following the command to move forwards, when the Time out expires, the sensor for the table’s reverse position is still active: either the device has not started, or the sensor remains active. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the valves de-energise and the device remains stationary where it is; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • ‘back’ position sensor constantly active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the reverse position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the connector is fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Connection blocked

How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12004-2.XX - Table - Actuator connector - External alarm

What this means: A message is provided for an external alarm relating to the table connector. In current versions of the machine software, the message is provided but is not triggered. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the connector is present; option configured by CEMAS.

M12004-3.XX – Mirror (rear/left) – Actuator connector – External alarm

What this means: A message is provided for an external alarm relating to the mirror connector. In current versions of the machine software, the message is provided but is not triggered. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the connector is present; option configured by CEMAS.

M12005-2.XX – Table – Actuator connector – Both position sensors

What this means: The forward and reverse position sensors for the table connector are active simultaneously: the position cannot be determined. Monitoring is always active when this device is present. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the valves de-energise and the device remains stationary; the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a faulty or short-circuited sensor that is always active;
  • sensors positioned so that they detect both positions;
  • sensor inputs configured incorrectly.

How to resolve:

  1. With the device stopped, check under Machine Diagnostics > PLC, on the Card Monitoring tab, which of the two inputs is active for no reason.
  2. Control the device via Tool Change > Tool Change, Manual tab > Connectors (In, Out): each sensor should only light up in its own position; reposition or replace the one that remains lit (maintenance technician).
  3. If the sensors are working, have the inputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Connectors tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the connector is present; option configured by CEMAS.

Sensor positioning

How to identify this: the component’s two position sensors are active at the same time.

Check:

  1. Move the component to one position and check that only the LED for the corresponding sensor is lit.
  2. Repeat in the other position.
  3. Check that each sensor is securely fitted and detects only its own position.

Remedy: reposition or replace the sensor that remains active (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12005-3.XX – Mirror (rear/left) – Actuator connector – Both position sensors

What this means: The forward and reverse position sensors for the mirror connector are active simultaneously: the position cannot be determined. Monitoring is always active when the device is present. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the valves de-energise and the device remains stationary; the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a faulty or short-circuited sensor that is always active;
  • sensors positioned so that they detect both positions;
  • sensor inputs configured incorrectly.

How to resolve:

  1. With the device stopped, check under Machine Diagnostics > PLC, on the Card Monitoring tab, which of the two inputs is active for no reason.
  2. Control the device via Tool Change > Tool Change, Manual tab > Connectors (In, Out): each sensor must light up only in its own position; reposition or replace the one that remains lit (maintenance technician).
  3. If the sensors are working, have the inputs checked in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Connectors tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the connector is present; option configured by CEMAS.

Sensor positioning

How to identify this: the component’s two position sensors are active at the same time.

Check:

  1. Move the component to one position and check that only the LED for the corresponding sensor is lit.
  2. Repeat in the other position.
  3. Check that each sensor is securely fitted and detects only its own position.

Remedy: reposition or replace the sensor that remains active (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12006-3.XX - Mirror (rear/left) - Actuator connector - Both commands

The controls of the actuator that moves the automatic connection plug have not been set correctly, as two different commands are active at the same time.

Reset the controls

How to identify it: the Both commands alarm reoccurs even when the connector is activated just once.

Check:

  1. Press Reset and repeat only one command at a time, whilst no cycle is in progress.
  2. If the alarm returns, check that the two contactor valves are assigned to different outputs in Machine Settings > General Settings > Tool Interfaces, under the zone tab, in the Connectors tab.

Remedy: correct the output configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12006-2.XX - Table - Actuator connector - Both commands

What this means: The two motion valves of the table connector are being actuated simultaneously: either due to a manual command issued during a cycle movement, or because the outputs have been configured incorrectly. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a manual command issued simultaneously with a cycle command;
  • the same output assigned to both movements.

How to resolve:

  1. Press Reset and repeat the movement using only one command at a time.
  2. If the alarm reoccurs, have the valve outputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Connectors tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

Availability: machine option: appears if the connector is present; option configured by CEMAS.

Reset the controls

How to identify it: the Both commands alarm reoccurs even when the connector is activated just once.

Check:

  1. Press Reset and repeat only one command at a time, whilst no cycle is in progress.
  2. If the alarm returns, check that the two contactor valves are assigned to different outputs in Machine Settings > General Settings > Tool Interfaces, under the zone tab, in the Connectors tab.

Remedy: correct the output configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12006-1.XX - Head - Actuator connector - Both commands

The controls of the actuator that moves the automatic connection plug have not been set correctly, as two different commands are active at the same time.

Reset the controls

How to identify it: the Both commands alarm reoccurs even when the connector is activated just once.

Check:

  1. Press Reset and repeat only one command at a time, whilst no cycle is in progress.
  2. If the alarm returns, check that the two contactor valves are assigned to different outputs in Machine Settings > General Settings > Tool Interfaces, under the zone tab, in the Connectors tab.

Remedy: correct the output configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12007-3.XX - Mirror (rear/left) - Actuator connector - Pressure switch

What this means: An alarm is provided for the pressure switch on the mirror’s automatic connection plug. In current versions of the machine software, the alarm is provided but is not activated. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm not displayed in the Alarm Monitor: none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the connector is present; option configured by CEMAS.

Check the pressure switch

How to identify the problem: the pressure switch on the connection plug does not confirm the pressure when the connector is closed.

Check:

  1. Check that the pressure switch LED lights up when pressure is present and that its input is active in Machine Diagnostics > PLC, under the Card Monitoring tab.
  2. Check the calibration using the adjustment screw.

Remedy: adjust or replace the pressure switch (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Check the solenoid valve

How to identify the fault: air does not reach the automatic connection plug when the connector is engaged.

Check:

  1. Check that the solenoid valve coil is receiving the signal (LED lit).
  2. Check that the valve switches and that there is pressure downstream.

Remedy: replace the faulty coil or valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12007-2.XX - Table - Actuator connector - Pressure switch

What this means: A warning is provided for the pressure switch on the table’s automatic connection plug. In current versions of the machine software, the warning is provided but is not activated. In the code, XX is the connector number (from 01 to 03).

*Effect*: alert not displayed in the Alarm Monitor**: none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the connector is present; option configured by CEMAS.

Check the pressure switch

How to identify the problem: the pressure switch on the connection plug does not confirm the pressure when the connector is closed.

Check:

  1. Check that the pressure switch LED lights up when pressure is present and that its input is active in Machine Diagnostics > PLC, under the Card Monitoring tab.
  2. Check the calibration using the adjustment screw.

Remedy: adjust or replace the pressure switch (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Check the solenoid valve

How to identify the fault: air does not reach the automatic connection plug when the connector is engaged.

Check:

  1. Check that the solenoid valve coil is receiving the signal (LED lit).
  2. Check that the valve switches and that there is pressure downstream.

Remedy: replace the faulty coil or valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12008-3.XX – Mirror (rear/left) – Actuator connector – Not in reverse position

What this means: A request has been made to unlock the tools on the table (clamped in the rest position) whilst the connector is still engaged: before unlocking, the spindle must have returned to its home position. The alarm is stored. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain locked.

Probable causes:

  • manual sequence carried out in the wrong order;
  • connectors locked in the ‘forward’ position;
  • ‘reverse’ position sensor out of calibration or faulty.

How to resolve:

  1. Move the connector back via Tool Change > Tool Change, Manual tab > Connectors (In, Out) and check that the reverse position sensor LED lights up.
  2. If the connector does not move, remove the obstruction and check the air supply and valve (maintenance technician).
  3. Press Reset and repeat the release procedure.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the connector is present; option configured by CEMAS.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Connection blocked

How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12008-1.XX - Head - Actuator connector - Not in rear position

The sensor that detects the backward position does not signal the presence of the actuator that moves the automatic connection plug of the head.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Connection blocked

How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12008-2.XX - Table - Actuator connector - Not in the ‘back’ position

What this means: A request has been made to release the tool on the table (clamped in the rest position) whilst the connector is still engaged: before releasing the tool, the connector must be returned to its original position. The alarm is stored. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain locked.

Probable causes:

  • manual sequence carried out in the wrong order;
  • connector locked in the ‘forward’ position;
  • ‘reverse’ position sensor out of calibration or faulty.

How to resolve:

  1. Move the connector back via Tool Change > Tool Change, Manual tab > Connectors (In, Out) and check that the reverse position sensor LED lights up.
  2. If the connector does not move, remove the obstruction and check the air supply and valve (maintenance technician).
  3. Press Reset and repeat the release procedure.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the connector is present; option configured by CEMAS.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Connection blocked

How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12009-3.XX - Mirror (rear/left) - Actuator connector - Not in forward position

What this means: An alarm is programmed for the mirror connector not being in the forward position. In current versions of the machine software, the alarm is programmed but is not activated. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the connector is present; option configured by CEMAS.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check inserts

How to recognise it: the connector cannot be fully inserted: the plug on the tool does not fit into the socket on the welding machine.

Check:

  1. With the machine switched off and secured, compare the inserts fitted to the welding machine’s socket with those on the tool’s plug.
  2. Check that there are no bent contacts or foreign objects.

Remedy: reposition the inserts so that they align correctly (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Connection blocked

How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12009-1.XX - Head - Actuator connector - Not in forward position

The sensor that detects the forward position does not signal the presence of the actuator that moves the automatic connection plug of the head.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check inserts

How to recognise it: the connector cannot be fully inserted: the plug on the tool does not fit into the socket on the welding machine.

Check:

  1. With the machine switched off and secured, compare the inserts fitted to the welding machine’s socket with those on the tool’s plug.
  2. Check that there are no bent contacts or foreign objects.

Remedy: reposition the inserts so that they align correctly (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Connection blocked

How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M12009-2.XX - Table - Actuator connector - Not in the forward position

What this means: An alarm is programmed for when the table is not in the forward position. In current versions of the machine software, the alarm is programmed but is not triggered. In the code, XX is the connector number (from 01 to 03).

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the connector is present; option configured by CEMAS.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check inserts

How to recognise it: the connector cannot be fully inserted: the plug on the tool does not fit into the socket on the welding machine.

Check:

  1. With the machine switched off and secured, compare the inserts fitted to the welding machine’s socket with those on the tool’s plug.
  2. Check that there are no bent contacts or foreign objects.

Remedy: reposition the inserts so that they align correctly (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Connection blocked

How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Clamp

Alarms relating to clamps – the devices that secure the tools to the head, table or spindle: incomplete movements, inconsistent sensor readings, interlock pressure not reached, invalid pump or safety inputs, or movements requested whilst the clamp is in the wrong position.

Clamps are configured under Machine Settings > General Settings > Tool Interfaces, in the zone tab, under the Clamp tab; they are operated manually via Tool Change > Tool Change, in the Manual tab > Clamps.

M14000-1.XX – Head – Clamp – Idle movement timeout

What this means: Following the command to move to the rest position, the sensor for that position of the head clamp did not activate within the Time-out set in Machine Settings > General Settings > Tool Interfaces, Head tab, Clamping tab (−1 disables the check). The clamp moves during tool change or, in manual mode, during repositioning.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • rest position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest): if this does not occur, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the clamp completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, Clamp tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14000-2.XX - Table - Clamp - Idle movement timeout

What this means: Following the command to move to the rest position, the sensor for that position of the table clamp did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamping tab (−1 deactivates the check). The clamp moves during tool change or, in manual mode, during repositioning.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • rest position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest): if this does not occur, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the clamp is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the clamp completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, Clamp tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14000-3.XX - Mirror (rear/left) - Clamp - Idle movement timeout

What this means: Following the command to move to the rest position, the sensor for that position of the mirror clamp did not activate within the Time-out set in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Clamping tab (−1 disables the check). The clamp moves during tool change or, in manual mode, during repositioning.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • rest position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest): if this does not occur, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the clamp completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, Clamp tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14001-2.XX - Table - Clamp - Work movement timeout

What this means: Following the command to move to the working position, the sensor for that position of the table clamp did not activate within the Time-out set in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamping tab (−1 deactivates the check). The clamp moves during tool change or, in manual mode, during repositioning.

Effect: Alarm (red line): the valves de-energise and the device remains stationary where it is; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • work position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest): if this does not occur, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the clamp is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the clamp completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, Clamp tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14001-1.XX – Head – Clamp – Work movement timeout

What this means: Following the command to move to the working position, the sensor for that position of the head clamp mechanism did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Head tab, Clamping tab (−1 disables the check). The clamp moves during tool change or, in manual mode, during repositioning.

Effect: Alarm (red line): the valves de-energise and the device remains stationary where it is; the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • work position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest): if this does not occur, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the clamp completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, Clamp tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14001-3.XX - Mirror (rear/left) - Clamp - Work movement timeout

What this means: Following the command to move to the working position, the sensor for that position of the mirror clamp did not activate within the Time-out set in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Clamping tab (−1 disables the check). The clamp moves during tool change or, in manual mode, during repositioning.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding process results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • work position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest): if this does not occur, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the clamp completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, Clamp tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14002-1.XX – Head – Clamp – Rest position not released

What this means: Following the command to move to the working position, once the Time out has elapsed, the sensor for the clamp’s rest position is still active: the device has not started, or the sensor remains on.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • rest position sensor constantly active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the rest position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before carrying out any work on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14002-3.XX - Mirror (rear/left) - Clamp - Rest position not released

What this means: After the command to move to the working position, when the Time-out expires, the sensor for the mirror clamp’s rest position is still active: the device has not started, or the sensor remains on.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • rest position sensor constantly active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the rest position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before carrying out any work on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14002-2.XX - Table - Clamp - Rest position not released

What this means: After the command to move to the working position, when the Time out expires, the sensor for the table clamp’s rest position is still active: the device has not started, or the sensor remains on.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • rest position sensor constantly active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the rest position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the clamp is active; this option is configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14003-3.XX - Mirror (rear/left) - Clamp - Working position not released

What this means: Following the command to return to the rest position, once the Time-out has elapsed, the mirror clamp working position sensor is still active: the device has not started, or the sensor remains on.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • working position sensor constantly active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the working position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before carrying out any work on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14003-2.XX - Table - Clamp - Work position not released

What this means: Following the command to return to the rest position, once the Time-out has elapsed, the sensor for the table clamp working position is still active: the device has not started, or the sensor remains on.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • working position sensor constantly active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the working position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before carrying out any work on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the clamp is active; this option is configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14003-1.XX – Head – Clamp – Work position not released

What this means: Following the command to return to the rest position, once the Time-out has elapsed, the sensor for the working position of the clamp is still active: the device has not started, or the sensor remains on.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • working position sensor constantly active or out of calibration.

How to resolve:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the working position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before carrying out any work on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14004-2.XX - Table - Clamp - External alarm

What this means: A message is provided for an external table clamp alarm. In current versions of the machine software, the message is provided but is not triggered.

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the clamp is present; option configured by CEMAS.

M14004-1.XX – Head – Clamp – External alarm

What this means: A message is provided for an external head clamp alarm. In current versions of the machine software, the message is provided but is not triggered.

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

M14004-3.XX - Mirror (rear/left) - Clamp - External alarm

What this means: A message is provided for an external mirror clamp alarm. In current versions of the machine software, the message is provided but is not triggered.

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

M14005-2.XX - Table - Clamp - Both position sensors

What this means: The sensors for the table clamp’s rest and working positions are active simultaneously: the position cannot be determined. Monitoring is always active when the device is present.

Effect: Alarm (red line): the valves de-energise and the device remains stationary; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a faulty or short-circuited sensor, which is always active;
  • sensors positioned so as to detect both positions;
  • sensor inputs configured incorrectly.

How to resolve:

  1. With the device stopped, check under Machine Diagnostics > PLC, on the Card Monitoring tab, which of the two inputs is active for no reason.
  2. Operate the device via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest): each sensor must light up only in its own position; reposition or replace the one that remains lit (maintenance technician).
  3. If the sensors are working, have the inputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamp tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the clamp is present; option configured by CEMAS.

Sensor positioning

How to identify this: the component’s two position sensors are active at the same time.

Check:

  1. Move the component to one position and check that only the LED for the corresponding sensor is lit.
  2. Repeat in the other position.
  3. Check that each sensor is securely fitted and detects only its own position.

Remedy: reposition or replace the sensor that remains active (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14005-3.XX - Mirror (rear/left) - Clamp - Both position sensors

What this means: The sensors for the mirror clamp’s rest and working positions are active simultaneously: the position cannot be determined. Monitoring is always active when the device is present.

Effect: Alarm (red line): the valves de-energise and the device remains stationary; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a faulty or short-circuited sensor, which is always active;
  • sensors positioned so as to detect both positions;
  • sensor inputs configured incorrectly.

How to resolve:

  1. With the device stopped, check under Machine Diagnostics > PLC, on the Card Monitoring tab, which of the two inputs is active for no reason.
  2. Control the device via Tool Change > Tool Change, Manual tab > Locks (Work, Rest): each sensor should only light up in its own position; reposition or replace the one that remains lit (maintenance technician).
  3. If the sensors are working, have the inputs checked in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Clamp tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

Sensor positioning

How to identify this: the component’s two position sensors are active at the same time.

Check:

  1. Move the component to one position and check that only the LED for the corresponding sensor is lit.
  2. Repeat in the other position.
  3. Check that each sensor is securely fitted and detects only its own position.

Remedy: reposition or replace the sensor that remains active (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14005-1.XX – Head – Clamp – Both position sensors

What this means: The sensors for the head clamp’s rest and working positions are active simultaneously: the position cannot be determined. Monitoring is always active when the device is present.

Effect: Alarm (red line): the valves de-energise and the device remains stationary; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a faulty or short-circuited sensor, which is always active;
  • sensors positioned so as to detect both positions;
  • sensor inputs configured incorrectly.

How to resolve:

  1. With the device stopped, check under Machine Diagnostics > PLC, on the Card Monitoring tab, which of the two inputs is active for no reason.
  2. Operate the device via Tool Change > Tool Change, Manual tab > Locks (Work, Rest): each sensor should only light up in its own position; reposition or replace the one that remains lit (maintenance technician).
  3. If the sensors are working, have the inputs checked in Machine Settings > General Settings > Tool Interfaces, Head tab, Clamp tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Sensor positioning

How to identify this: the component’s two position sensors are active at the same time.

Check:

  1. Move the component to one position and check that only the LED for the corresponding sensor is lit.
  2. Repeat in the other position.
  3. Check that each sensor is securely fitted and detects only its own position.

Remedy: reposition or replace the sensor that remains active (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14006-1.XX – Head – Clamp – Both commands

What this means: The two valves controlling the head clamp are being actuated simultaneously: either due to a manual command issued during a cycle, or because the outputs have been configured incorrectly.

Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a manual command given at the same time as a cycle command;
  • the same output assigned to both movements.

How to resolve:

  1. Press Reset and repeat the movement using only one command at a time.
  2. If the alarm reoccurs, have the valve outputs checked in Machine Settings > General Settings > Tool Interfaces, Head tab, Clamp tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Reset the controls

How to identify it: the Both commands alarm reoccurs even when the clamp is commanded just once.

Check:

  1. Press Reset and repeat only one command at a time, whilst no cycle is in progress.
  2. If the alarm returns, check that the two clamping valves are assigned to different outputs in Machine Settings > General Settings > Tool Interfaces, under the zone tab, in the Clamp tab.

Remedy: correct the output configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14006-2.XX - Table - Clamp - Both commands

What this means: The two valves controlling the table clamp mechanism are being actuated simultaneously: either due to a manual command issued during a cycle movement, or because the outputs have been configured incorrectly.

Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a manual command given at the same time as a cycle command;
  • the same output assigned to both movements.

How to resolve:

  1. Press Reset and repeat the movement using only one command at a time.
  2. If the alarm reoccurs, have the valve outputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamp tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

Availability: machine option: appears if the clamp is active; option configured by CEMAS.

Reset the controls

How to identify it: the Both commands alarm reoccurs even when the clamp is commanded just once.

Check:

  1. Press Reset and repeat only one command at a time, whilst no cycle is in progress.
  2. If the alarm returns, check that the two clamping valves are assigned to different outputs in Machine Settings > General Settings > Tool Interfaces, under the zone tab, in the Clamp tab.

Remedy: correct the output configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14006-3.XX - Mirror (rear/left) - Clamp - Both commands

What this means: The two movement valves for the mirror clamp are being controlled simultaneously: either a manual command has been issued during a cycle movement, or the outputs have been configured incorrectly.

Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a manual command given at the same time as a cycle command;
  • the same output assigned to two movements.

How to resolve:

  1. Press Reset and repeat the movement using only one command at a time.
  2. If the alarm reoccurs, have the valve outputs checked in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Clamp tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

Availability: only on machines with the following: IR mirror (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

Reset the controls

How to identify it: the Both commands alarm reoccurs even when the clamp is commanded just once.

Check:

  1. Press Reset and repeat only one command at a time, whilst no cycle is in progress.
  2. If the alarm returns, check that the two clamping valves are assigned to different outputs in Machine Settings > General Settings > Tool Interfaces, under the zone tab, in the Clamp tab.

Remedy: correct the output configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14007-3.XX - Mirror (rear/left) - Clamp - Not in rest position

What this means: Without tools, the mirror spindle (IR and HP machines) moves whilst the mirror clamp is not in the rest position: the clamp may cause an impact. The alarm is logged.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • clamp left in the ‘working’ position after tool unloading;
  • clamp stuck halfway through its stroke;
  • rest position sensor out of calibration or faulty.

How to resolve:

  1. Return the clamp to the rest position via Tool Change > Tool Change, Manual tab > Clamps (Operating, Rest) and check the rest position sensor LED.
  2. If it does not move or the sensor does not light up, check the air supply, valve and sensor (maintenance technician).
  3. Press Reset and repeat the axis movement.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.
Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14007-1.XX - Head - Clamp - Not in the rest position

What this means: Without any tools in place, the table axis (laser machines) or head axis (IR and HP machines) moves whilst the head clamp is not in the rest position: the clamp may cause an impact. The alarm is logged.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • clamp left in ‘Work’ mode after tool unloading;
  • clamp stuck halfway through its stroke;
  • rest position sensor out of calibration or faulty.

How to resolve:

  1. Return the clamp to the rest position via Tool Change > Tool Change, Manual tab > Clamps (Operating, Rest) and check the rest position sensor LED.
  2. If it does not move or the sensor does not light up, check the air supply, valve and sensor (maintenance technician).
  3. Press Reset and repeat the axis movement.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.
Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14007-2.XX - Table - Clamp - Not in the rest position

What this means: Without any tools, the table axis moves whilst the table clamp is not in the rest position: the clamp may cause an impact. The alarm is stored.

Effect: Alarm (red line): the machine switches to manual mode (welding in progress results in a scrap piece); automatic cycle and tool change remain blocked.

Probable causes:

  • clamp left in the ‘working’ position after tool unloading;
  • clamp stuck halfway through its stroke;
  • rest position sensor out of calibration or faulty.

How to resolve:

  1. Set the clamp to rest mode via Tool Change > Tool Change, Manual tab > Clamps (Operating, Rest) and check the rest position sensor LED.
  2. If it does not move or the sensor does not light up, check the air supply, valve and sensor (maintenance technician).
  3. Press Reset and repeat the axis movement.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.
Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the clamp is present; option configured by CEMAS.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14008-3.XX - Mirror (rear/left) - Clamp - Not in operating position

What this means: A command has been issued to engage the connectors, or to move the machine whilst the tools are loaded, whilst the clamping mechanism for the workpiece is not in the working position: the tools may not be securely fastened. The alarm is stored.

Effect: Alarm (red line): the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • clamp not closed before proceeding;
  • clamp stuck halfway through its stroke;
  • working position sensor out of calibration or faulty.

How to resolve:

  1. Set the clamp mechanism to ‘Operating’ via Tool Change > Tool Change, Manual tab > Clamps (Operating, Rest) and check the operating sensor LED.
  2. Check that the tools are correctly positioned and that nothing is preventing them from closing (maintenance technician).
  3. Press Reset and repeat the command.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.
Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14008-2.XX - Table - Clamp - Not in working position

What this means: A command has been issued to engage the connectors, or to move the machine whilst the tools are loaded, whilst the table clamp is not in the working position: the tools may not be secured. The alarm is stored.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • clamp not closed before proceeding;
  • clamp stuck halfway through its stroke;
  • working position sensor out of calibration or faulty.

How to resolve:

  1. Set the clamp to ‘Operating’ via Tool Change > Tool Change, Manual tab > Clamps (Operating, Rest) and check the operating sensor LED.
  2. Check that the tool is correctly positioned and that nothing is preventing it from closing (maintenance technician).
  3. Press Reset and repeat the command.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.
Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the clamp is present; option configured by CEMAS.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14008-1.XX – Head – Clamp – Not in operating position

What this means: A command has been issued to engage the connectors, or to move the machine whilst the tools are loaded, whilst the head clamp is not in the working position: the tools may not be secured. The alarm is stored.

Effect: Alarm (red line): the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • Clamp not closed before proceeding;
  • Clamp stuck halfway;
  • Working position sensor out of calibration or faulty.

How to resolve:

  1. Set the clamp to ‘Operating’ via Tool Change > Tool Change, Manual tab > Clamps (Operating, Rest) and check the operating sensor LED.
  2. Check that the tools are correctly positioned and that nothing is preventing them from closing (maintenance technician).
  3. Press Reset and repeat the command.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.
Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Clamp locked

How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.

Check:

  1. Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14009-1.XX - Head - Clamp - Circuit 1 pressure timeout

What this means: The interlock valve for circuit 1 of the head clamp system is activated, but the pressure switch for circuit 1 does not confirm the pressure within the Interlock Pressure Timeout set in Machine Settings > General Settings > Tool Interfaces, Head tab, Clamping tab.

Effect: Alarm (red line): the interlock valves and the pump remain active; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • Insufficient supply pressure or the pump failing to reach it;
  • Leaks in the clamp circuit;
  • Pressure switch out of calibration or faulty;
  • Time-out set too short.

How to resolve:

  1. Check the supply pressure and ensure there are no leaks in the circuit (maintenance technician).
  2. Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the pressure switch input activates when the clamp is in operation; if not, adjust or replace it (maintenance technician).
  3. If the pressure is present but delayed, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Insufficient time for inspection

How to recognise it: the interlock pressure is reached, but after the Interlock pressure time-out: the alarm appears even if the pressure switch subsequently confirms.

Check:

  1. With the clamp in operation, check under Machine Diagnostics > PLC, Card Monitoring tab, to see how long it takes for the pressure switch input to activate.
  2. Compare this time with the Time-out for Interlock pressure in Machine settings > General settings > Tool interfaces, under the zone tab, Clamp tab.

Remedy: if the pressure rises steadily but slowly, increase the Time-out (CEMAS technician); if it is slower than usual, check the pump and for leaks (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14009-2.XX - Table - Clamp - Circuit 1 pressure timeout

What this means: The interlock valve for circuit 1 of the table clamp system is activated, but the pressure switch for circuit 1 does not confirm the pressure within the Interlock Pressure Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamping tab.

Effect: Alarm (red line): the interlock valves and the pump remain active; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • Insufficient supply pressure or the pump failing to reach it;
  • Leaks in the clamp circuit;
  • Pressure switch out of calibration or faulty;
  • Time-out set too short.

How to resolve:

  1. Check the supply pressure and ensure there are no leaks in the circuit (maintenance technician).
  2. Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the pressure switch input activates when the clamp is in operation; if not, adjust or replace it (maintenance technician).
  3. If the pressure is present but delayed, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the clamp is active; option configured by CEMAS.

Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Insufficient time for inspection

How to recognise it: the interlock pressure is reached, but after the Interlock pressure time-out: the alarm appears even if the pressure switch subsequently confirms.

Check:

  1. With the clamp in operation, check under Machine Diagnostics > PLC, Card Monitoring tab, to see how long it takes for the pressure switch input to activate.
  2. Compare this time with the Time-out for Interlock pressure in Machine settings > General settings > Tool interfaces, under the zone tab, Clamp tab.

Remedy: if the pressure rises steadily but slowly, increase the Time-out (CEMAS technician); if it is slower than usual, check the pump and for leaks (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14009-3.XX - Mirror (rear/left) - Clamp - Circuit 1 pressure timeout

What this means: The interlock valve for circuit 1 of the mirror clamp system is activated, but the pressure switch for circuit 1 does not confirm that the pressure is within the Interlock Pressure Timeout set in Machine Settings > General Settings > Tool Interfaces, under the Mirror tab and the Clamping tab.

Probable causes:

  • Insufficient supply pressure or the pump failing to reach it;
  • Leaks in the clamp circuit;
  • Pressure switch out of calibration or faulty;
  • Time-out set too short.

How to resolve:

  1. Check the supply pressure and ensure there are no leaks in the circuit (maintenance technician).
  2. Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the pressure switch input activates when the clamp is in operation; if not, adjust or replace it (maintenance technician).
  3. If the pressure is present but delayed, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Insufficient time for inspection

How to recognise it: the interlock pressure is reached, but after the Interlock pressure time-out: the alarm appears even if the pressure switch subsequently confirms.

Check:

  1. With the clamp in operation, check under Machine Diagnostics > PLC, Card Monitoring tab, to see how long it takes for the pressure switch input to activate.
  2. Compare this time with the Time-out for Interlock pressure in Machine settings > General settings > Tool interfaces, under the zone tab, Clamp tab.

Remedy: if the pressure rises steadily but slowly, increase the Time-out (CEMAS technician); if it is slower than usual, check the pump and for leaks (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14010-2.XX - Table - Clamp - Circuit 2 pressure timeout

What this means: The interlock valve for circuit 2 of the table clamp system is activated, but the pressure switch for circuit 2 does not confirm that the pressure is within the Interlock Pressure Timeout set in Machine Settings > General Settings > Tool Interfaces, under the Table tab and the Clamping tab. Circuit 2 is only controlled if its valve and pressure switch are enabled.

Effect: Alarm (red line): the interlock valves and the pump remain active; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • insufficient supply pressure or the pump failing to reach it;
  • leaks in the clamp circuit;
  • pressure switch out of calibration or faulty;
  • Time-out set too short.

How to resolve:

  1. Check the supply pressure and ensure there are no leaks in the circuit (maintenance technician).
  2. Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the pressure switch input activates when the clamp is in operation; if not, adjust or replace it (maintenance technician).
  3. If the pressure is present but delayed, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before carrying out any work on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the clamp is active; option configured by CEMAS.

Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Insufficient time for inspection

How to recognise it: the interlock pressure is reached, but after the Interlock pressure time-out: the alarm appears even if the pressure switch subsequently confirms.

Check:

  1. With the clamp in operation, check under Machine Diagnostics > PLC, Card Monitoring tab, to see how long it takes for the pressure switch input to activate.
  2. Compare this time with the Time-out for Interlock pressure in Machine settings > General settings > Tool interfaces, under the zone tab, Clamp tab.

Remedy: if the pressure rises steadily but slowly, increase the Time-out (CEMAS technician); if it is slower than usual, check the pump and for leaks (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14010-1.XX - Head - Clamp - Circuit 2 pressure timeout

What this means: The interlock valve for circuit 2 of the head clamp system is activated, but the pressure switch for circuit 2 does not confirm that the pressure is within the Interlock Pressure Timeout set in Machine Settings > General Settings > Tool Interfaces, under the Head tab and the Clamping tab. Circuit 2 is only controlled if its valve and pressure switch are enabled.

Effect: Alarm (red line): the interlock valves and the pump remain active; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • insufficient supply pressure or the pump failing to reach it;
  • leaks in the clamp circuit;
  • pressure switch out of calibration or faulty;
  • Time-out set too short.

How to resolve:

  1. Check the supply pressure and ensure there are no leaks in the circuit (maintenance technician).
  2. Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the pressure switch input activates when the clamp is in operation; if not, adjust or replace it (maintenance technician).
  3. If the pressure is present but delayed, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Insufficient time for inspection

How to recognise it: the interlock pressure is reached, but after the Interlock pressure time-out: the alarm appears even if the pressure switch subsequently confirms.

Check:

  1. With the clamp in operation, check under Machine Diagnostics > PLC, Card Monitoring tab, to see how long it takes for the pressure switch input to activate.
  2. Compare this time with the Time-out for Interlock pressure in Machine settings > General settings > Tool interfaces, under the zone tab, Clamp tab.

Remedy: if the pressure rises steadily but slowly, increase the Time-out (CEMAS technician); if it is slower than usual, check the pump and for leaks (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14010-3.XX - Mirror (rear/left) - Clamp - Circuit 2 pressure timeout

What this means: The interlock valve for circuit 2 of the mirror clamp system is activated, but the pressure switch for circuit 2 does not confirm that the pressure is within the Interlock Pressure Timeout set in Machine Settings > General Settings > Tool Interfaces, under the Mirror tab and the Clamping tab. Circuit 2 is only controlled if its valve and pressure switch are enabled.

Effect: Alarm (red line): the interlock valves and the pump remain active; the machine switches to manual mode (a welding process results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • insufficient supply pressure or the pump failing to reach it;
  • leaks in the clamp circuit;
  • pressure switch out of calibration or faulty;
  • Time-out set too short.

How to resolve:

  1. Check the supply pressure and ensure there are no leaks in the circuit (maintenance technician).
  2. Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the pressure switch input is activated when the clamp is in operation; if not, adjust or replace it (maintenance technician).
  3. If the pressure is present but delayed, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before carrying out any work on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

Move not completed

How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.

Check:

  1. Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Insufficient time for inspection

How to recognise it: the interlock pressure is reached, but after the Interlock pressure time-out: the alarm appears even if the pressure switch subsequently confirms.

Check:

  1. With the clamp in operation, check under Machine Diagnostics > PLC, Card Monitoring tab, to see how long it takes for the pressure switch input to activate.
  2. Compare this time with the Time-out for Interlock pressure in Machine settings > General settings > Tool interfaces, under the zone tab, Clamp tab.

Remedy: if the pressure rises steadily but slowly, increase the Time-out (CEMAS technician); if it is slower than usual, check the pump and for leaks (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14011-2.XX - Table - Clamp - Invalid pump

What this means: The pump associated with the table clamp has an invalid number: the machine manages pumps 1 to 4. Configuration error; always check.

Effect: Alarm (red line): the clamp cannot be activated; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • Incorrect pump number set in the clamp configuration.

How to resolve:

  1. Have the pump assigned to the clamp checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamp tab, and the pumps configured in Machine Settings > General Settings > Components (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if a clamp is present; this option is configured by CEMAS.

Pump configuration

How to recognise it: the clamp signals the message Invalid pump and does not move.

Check:

  1. Check the pump number assigned to the clamp unit in Machine Settings > General Settings > Tool Interfaces, zone tab, Clamp tab: valid values are 1 to 4.
  2. Check that the pump is configured in Machine Settings > General Settings > Components.

Remedy: correct the configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14011-1.XX – Head – Clamp – Pump invalid

What this means: The pump associated with the head clamp has an invalid number: the machine manages pumps 1 to 4. Configuration error; always check.

Effect: Alarm (red line): the clamp cannot be activated; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • Incorrect pump number set in the clamp configuration.

How to resolve:

  1. Have the pump assigned to the clamp system checked in Machine Settings > General Settings > Tool Interfaces, Head tab, Clamp tab, and the pumps configured in Machine Settings > General Settings > Components (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Pump configuration

How to recognise it: the clamp signals the message Invalid pump and does not move.

Check:

  1. Check the pump number assigned to the clamp unit in Machine Settings > General Settings > Tool Interfaces, zone tab, Clamp tab: valid values are 1 to 4.
  2. Check that the pump is configured in Machine Settings > General Settings > Components.

Remedy: correct the configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14011-3.XX - Mirror (rear/left) - Clamp - Pump faulty

What this means: The pump associated with the mirror clamp has an invalid number: the machine manages pumps 1 to 4. Configuration error; always check.

Effect: Alarm (red line): the clamp cannot be activated; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain locked.

Probable causes:

  • Pump number set incorrectly in the clamp configuration.

How to resolve:

  1. Have the pump assigned to the clamp system checked in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Clamp tab, and the pumps configured in Machine Settings > General Settings > Components (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

Availability: only on machines with the following: IR mirror (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

Pump configuration

How to recognise it: the clamp signals the message Invalid pump and does not move.

Check:

  1. Check the pump number assigned to the clamp unit in Machine Settings > General Settings > Tool Interfaces, zone tab, Clamp tab: valid values are 1 to 4.
  2. Check that the pump is configured in Machine Settings > General Settings > Components.

Remedy: correct the configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M14012-3.XX - Mirror (rear/left) - Clamp - Safety inputs not present

What this means: With the operator safety devices in place, the two channels of the safety inputs for the mirror clamp pressure switch are not consistent: for 500 milliseconds (ms), an interlock valve is activated without pressure confirmation from the first channel, or the two channels are out of sync. Checked only if the safety inputs are configured; this status is stored.

Effect: Alarm (red line): the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • Insufficient interlock pressure;
  • One of the two safety pressure switches is faulty, out of calibration or disconnected.

How to resolve:

  1. Check the two safety inputs for the ‘clamp in operation’ status in Machine Diagnostics > PLC, under the Card Monitoring tab: both must be active.
  2. If one remains off, check the pressure, wiring and calibration of the relevant pressure switch (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears if the clamp is fitted; option configured by CEMAS.

M14012-2.XX - Table - Clamp - Safety inputs not present

What this means: With the operator safety devices in place, the two channels of the table clamp pressure switch’s safety inputs are inconsistent: for 500 milliseconds (ms), an interlock valve is activated without pressure confirmation from the first channel, or the two channels are out of sync. Checked only if the safety inputs are configured; remains stored.

Effect: Alarm (red line): the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • Insufficient interlock pressure;
  • One of the two safety pressure switches is faulty, out of calibration or disconnected.

How to resolve:

  1. Check the two safety inputs for the ‘Clamp in operation’ status under Machine Diagnostics > PLC, Card Monitoring tab: both must be active.
  2. If one remains off, check the pressure, wiring and calibration of the relevant pressure switch (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the clamp is present; option configured by CEMAS.

M14012-1.XX – Head – Clamp – Safety inputs not present

What this means: With the operator safety devices in place, the two channels of the head clamp pressure switch’s safety inputs are not consistent: for 500 milliseconds (ms), an interlock valve is activated without pressure confirmation from the first channel, or the two channels are out of sync. Checked only if the safety inputs are configured; the status is stored.

Effect: Alarm (red line): the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • Insufficient interlock pressure;
  • One of the two safety pressure switches is faulty, out of calibration or disconnected.

How to resolve:

  1. Check the two safety inputs for the ‘clamp in operation’ status in Machine Diagnostics > PLC, under the Card Monitoring tab: both must be active.
  2. If one remains off, check the pressure, wiring and calibration of the relevant pressure switch (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the clamp is present; option configured by CEMAS.

Axis

Alarms relating to the axes that move the table, head and mirror: drives, brakes, switches, overtravel, referencing, positions, the machine’s load cell, force-related procedures and, on hydraulic vibration machines, the table’s hydraulic power unit. The alarm message indicates the area (Head, Table, Plate).

The status of the motors can be viewed under Machine Diagnostics > Motor Status; manual movements are controlled via Machine Diagnostics > Manual Movements, Machine tab.

M15000-1.XX – Spindle – Axis – Axis alarm

1.25.0

What this means: this message (head axis summary alarm) is provided for in the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the message appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate (HP9, HP14, HP20, HP-P125).

M15300-2.XX - Table - Axis calibration and certification - Calibration timeout

What this means: the table axis force calibration procedure did not complete within the maximum time limit (default 600 seconds (s), configured by CEMAS).

Effect: Alarm (red line). The procedure is interrupted (status Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.

Probable causes:

  • force failing to stabilise at the required values (Axis calibration and certification settings);
  • external load cell incorrectly positioned or axis obstructed;
  • procedure left on hold (Calibration not completed).

How to resolve:

  1. Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms (CEMAS technician).
  2. Check that nothing is obstructing the axis and that there are no other active alarms.
  3. Repeat the procedure (CEMAS technician) and check the result under Machine Diagnostics > Calibrations and Certifications.

Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Axis calibration and certification settings

How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.

Check:

  1. Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
  2. Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).

Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Calibration not completed

How to identify this: under Machine Diagnostics > Calibrations and Certifications, Table tab > Calibration, the result is Interrupted or Not performed.

Check:

  1. Check the date and result of the last calibration.
  2. Check Machine Status > Alarm Monitor for the alarms that caused the calibration to be interrupted.

Remedy: once the causes have been rectified, the calibration must be repeated by CEMAS Elettra personnel or under their supervision.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15000-2.XX - Table - Axis - Axis alarm

What this means: summary message: the table axis has an alarm listed in its details (drive, switches, overtravel).

Effect: The signal is not displayed in the Alarm Monitor. Specific alarms relating to the table axis details (M151xx-2.XX) appear: follow the instructions for those entries.

Axis status coding

How to recognise it: the axis is stationary in alarm mode and its drive signals an abnormal status.

Check:

  1. In Machine Diagnostics > Motor Status, open the axis card and tap the i icon: the diagnostics pop-up displays the drive’s current statuses, errors and warnings.
  2. Make a note of the statuses and errors displayed.

Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the fault persists, report the noted data to CEMAS Elettra support.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15000-3.XX - Mirror (rear/left) - Axle - Axle alarm

What this means: this message (mirror axis summary alarm) is provided for in the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the message appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.

Availability: only on IR machines (IR9, IR14, IR20) and HP machines with hot plates (HP9, HP14, HP20, HP-P125).

Axis status coding

How to recognise it: the axis is stationary in alarm mode and its drive signals an abnormal status.

Check:

  1. In Machine Diagnostics > Motor Status, open the axis card and tap the i icon: the diagnostics pop-up displays the drive’s current statuses, errors and warnings.
  2. Make a note of the statuses and errors displayed.

Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the fault persists, report the noted data to CEMAS Elettra support.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15100-1.XX - Head - Axis Details - External Alarm

1.25.0

What this means: this warning (external head-axis alarm) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the warning appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate (HP9, HP14, HP20, HP-P125).

M15100-2.XX - Table - Beam - External alarm

What this means: this warning (external table axis alarm) is provided for in the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the warning appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.

M15100-3.XX - Mirror (rear/left) - Axle - External alarm

What this means: this warning (external mirror axis alarm) is provided for in the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the warning appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.

Availability: only on IR machines (IR9, IR14, IR20) and HP hot plate machines (HP9, HP14, HP20, HP-P125).

M15300-1.XX - Head - Axis calibration and certification - Calibration timeout

1.25.0

What this means: the calibration procedure for the head axis force did not complete within the maximum time limit (default 600 seconds (s), configured by CEMAS).

Effect: Alarm (red line). The procedure is interrupted (status Interrupted under Machine Diagnostics > Calibrations and Certifications); for the rest of the machine, this is merely a warning.

Probable causes:

  • force failing to stabilise at the required values (Axis calibration and certification settings);
  • external load cell incorrectly positioned or axis obstructed;
  • procedure left on hold (Calibration not completed).

How to resolve:

  1. Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms (CEMAS technician).
  2. Check that nothing is obstructing the axis and that there are no other active alarms.
  3. Repeat the procedure (CEMAS technician) and check the result under Machine Diagnostics > Calibrations and Certifications.

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15101-2.XX – Table – Circuit board – Breaker triggered

What this means: one of the circuit breakers (logic thermal or power thermal) supplying power to the table axis drive has tripped.

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the motor, cable or drive (entry Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not reset;
  • auxiliary contact or input wiring disconnected.

How to resolve:

  1. In the electric panel, reset the circuit breaker (logic thermal or power thermal) for the table axis (electrical maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload in the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and wiring.

Reset: it clears automatically when the circuit breaker is re-closed; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a circuit breaker that has tripped.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Circuit breaker (thermal) has tripped

How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.

Check:

  1. Locate the component’s circuit breaker on the wiring diagram and check its position.
  2. Check that the thermal setting corresponds to the diagram.
  3. Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.

Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15301-2.XX - Table - Axis calibration and certification - Certification timeout

What this means: the table axis force certification procedure has not been completed within the maximum time limit (default 900 seconds (s), configured by CEMAS).

Effect: Alarm (red line). The procedure is interrupted (status Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.

Probable causes:

  • force failing to stabilise at the required values (Axis calibration and certification settings);
  • external load cell incorrectly positioned or axis obstructed;
  • procedure left on hold (Certification not completed).

How to resolve:

  1. Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms (CEMAS technician).
  2. Check that nothing is obstructing the axis and that there are no other active alarms.
  3. Repeat the procedure (CEMAS technician) and check the result under Machine Diagnostics > Calibrations and Certifications.

Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Axis calibration and certification settings

How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.

Check:

  1. Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
  2. Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).

Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Certification not completed

How to identify it: under Machine Diagnostics > Calibrations and Certifications, on the Table tab > Certification, the result is Interrupted or Not performed.

Check:

  1. Check the date and result of the last certification.
  2. Check Machine status > Alarm monitor for the alarms that caused the interruption.

Remedy: once the causes have been rectified, the certification must be repeated by CEMAS Elettra personnel or under their supervision.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15101-3.XX - Mirror (rear/left) - Axle - Breaker triggered

What this means: one of the circuit breakers (thermal logic or thermal power) supplying power to the mirror axis drive has tripped.

Effect: Alarm (red line). Mirror stationary (drive disabled) and axis not ready: the automatic cycle cannot continue.

Probable causes:

  • circuit breaker tripped due to an overload or short circuit on the motor, cable or drive (see Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not re-closed;
  • auxiliary contact or input wiring disconnected.

How to resolve:

  1. In the electric panel, reset the circuit breaker (logic thermal or power thermal) for the mirror axis (electrical maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and wiring.

Reset: it clears automatically when the circuit breaker is re-closed; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a circuit breaker that has tripped.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP machines with hot plates (HP9, HP14, HP20, HP-P125).

Circuit breaker (thermal) has tripped

How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.

Check:

  1. Locate the component’s circuit breaker on the wiring diagram and check its position.
  2. Check that the thermal setting corresponds to the diagram.
  3. Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.

Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15001-3.XX – Mirror (rear/left) – Axle – Logic switch

What this means: The circuit breaker (thermal logic) supplying power to the mirror drive control unit has tripped: the auxiliary contact input, enabled in the configuration, is low.

Effect: Alarm (red line). Mirror stationary (drive disabled) and axis not ready: the automatic cycle cannot continue.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the drive power supply (item Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not re-closed;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the mirror logic circuit breaker (electrical maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and the wiring.

Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a circuit breaker that has tripped.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP hot plate machines (HP9, HP14, HP20, HP-P125).

Circuit breaker (thermal) has tripped

How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.

Check:

  1. Locate the component’s circuit breaker on the wiring diagram and check its position.
  2. Check that the thermal setting corresponds to the diagram.
  3. Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.

Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15001-1.XX - Head - Shaft - Safety brake opening timeout

1.25.0

What this means: when the head-axis safety brake is released, with the safety devices in place, the brake-open signal does not arrive within 500 milliseconds (ms) – a fixed value. Check only active if the signal is enabled.

Effect: Alarm (red line). The head stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • brake faulty, not powered or with the connector disconnected (Brake function item);
  • brake switch tripped (Breaker triggered alarm);
  • brake open sensor faulty, out of calibration or disconnected.

How to resolve:

  1. If Brake breaker triggered is also active under Machine status > Alarm monitor, resolve that first.
  2. Check the brake power supply and connector: when released, the brake must open (maintenance technician).
  3. Check that the open brake sensor LED lights up; if not, adjust or replace the sensor (maintenance technician).
  4. If the brake does not open, do not force the axis.

Reset: alarm stored; clear by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and hot plate HP (HP9, HP14, HP20, HP-P125). Machine option configured by CEMAS.

M15101-1.XX - Head - Shaft details - Breaker triggered

1.25.0

What this means: one of the circuit breakers (thermal logic or thermal power) supplying power to the head axis drive has tripped.

Effect: Alarm (red line). Head drive disabled: axis stationary and not ready; the automatic cycle cannot continue.

Probable causes:

  • circuit breaker tripped due to an overload or short circuit on the motor, cable or drive (see Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not reset;
  • auxiliary contact or input wiring disconnected.

How to resolve:

  1. In the electric panel, reset the circuit breaker (logic thermal or power thermal) for the head axis (electrical maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and wiring.

Reset: it clears automatically when the circuit breaker is re-closed; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised maintenance technicians only, with the machine in a safe state as per the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15301-1.XX - Head - Axis calibration and certification - Certification timeout

1.25.0

What this means: the head axis force certification procedure has not been completed within the maximum time limit (default 900 seconds (s), configured by CEMAS).

Effect: Alarm (red line). The procedure is interrupted (result Interrupted in Machine Diagnostics > Calibrations and Certifications); for the rest of the machine, this is merely a warning.

Probable causes:

  • force failing to stabilise at the required values (Axis calibration and certification settings);
  • external load cell incorrectly positioned or axis obstructed;
  • procedure left on hold (Certification not completed).

How to resolve:

  1. Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms (CEMAS technician).
  2. Check that nothing is obstructing the axis and that there are no other active alarms.
  3. Repeat the procedure (CEMAS technician) and check the result under Machine Diagnostics > Calibrations and Certifications.

Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15302-1.XX - Head - Axis calibration and certification - Timeout capability

1.25.0

What this means: the head axis force capability procedure did not complete within the maximum time limit (default 900 seconds (s), configured by CEMAS).

Effect: Alarm (red line). The procedure is interrupted (result Interrupted in Machine Diagnostics > Calibrations and Certifications); for the rest of the machine, this is merely a warning.

Probable causes:

  • force failing to stabilise at the required values (Axis calibration and certification settings);
  • external load cell incorrectly positioned or axis obstructed;
  • procedure left on hold (Capability not completed).

How to resolve:

  1. Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms (CEMAS technician).
  2. Check that nothing is obstructing the axis and that there are no other active alarms.
  3. Repeat the procedure (CEMAS technician) and check the result under Machine Diagnostics > Calibrations and Certifications.

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15102-1.XX - Head - Axis Details - Drive not configured

1.25.0

What this means: The field network diagnostics (PROFINET) signal that the head axis drive is either not configured or has a configuration that differs from that specified in the machine software.

Effect: Alarm (red line). Head drive disabled: axis is stationary and not ready; the automatic cycle cannot continue.

Probable causes:

  • the drive has been replaced with a non-identical one or has not yet been configured (see Configure drive);
  • drive configuration lost.

How to resolve:

  1. Check whether the drive has been replaced recently: the replacement must be identical to the original.
  2. Configure the drive (CEMAS technician).

Reset: the alarm clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15002-1.XX – Head – Axle – Breaker triggered

1.25.0

What this means: The circuit breaker (thermal) supplying the head-axis safety brake has tripped: the input of the circuit breaker’s auxiliary contact, enabled in the configuration, is low.

Effect: Alarm (red line). The head stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the brake or its cable (item Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not reset;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the head brake circuit breaker (electrical maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and wiring.

Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a circuit breaker that has tripped.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15302-2.XX - Table - Axis calibration and certification - Timeout capability

What this means: the table axis force capability procedure did not complete within the maximum time limit (default 900 seconds (s), configured by CEMAS).

Effect: Alarm (red line). The procedure is interrupted (status Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.

Probable causes:

  • force failing to stabilise at the required values (Axis calibration and certification settings);
  • external load cell incorrectly positioned or axis obstructed;
  • procedure left on hold (Capability not completed).

How to resolve:

  1. Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms (CEMAS technician).
  2. Check that nothing is obstructing the axis and that there are no other active alarms.
  3. Repeat the procedure (CEMAS technician) and check the result under Machine Diagnostics > Calibrations and Certifications.

Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Axis calibration and certification settings

How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.

Check:

  1. Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
  2. Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).

Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Capability not completed

How to identify it: under Machine Diagnostics > Calibrations and Certifications, Table tab > Capability, the result is Interrupted or Not performed.

Check:

  1. Check the date and result of the last capability test.
  2. Check Machine status > Alarm monitor for the alarms that caused the interruption.

Remedy: eliminate the causes; the capability test must be repeated by CEMAS Elettra personnel or under their supervision.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15102-3.XX - Mirror (rear/left) - Axle - Drive mechanism not configured

What this means: the field network diagnostics (PROFINET) signal that the mirror axis drive is either not configured or has a configuration that differs from that specified in the machine software.

Effect: Alarm (red line). Mirror stationary (drive disabled) and axis not ready: the automatic cycle cannot continue.

Probable causes:

  • drive replaced with a non-identical one or not yet configured (Configure drive option);
  • drive configuration lost.

How to resolve:

  1. Check whether the drive has been replaced recently: the replacement must be identical to the original.
  2. Configure the drive (CEMAS technician).

Reset: the alarm clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP machines with hot plates (HP9, HP14, HP20, HP-P125).

Configure the drive

How to identify this: the axis drive is not configured, for example following a replacement.

Check:

  1. Check whether the drive has been replaced recently.
  2. Check that the model fitted is the one specified in the wiring diagram.

Remedy: the drive must be configured by CEMAS Elettra personnel: contact support (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15102-2.XX – Table – Axis – Drive not configured

What this means: The field network diagnostics (PROFINET) signal that the table axis drive is either not configured or has a configuration that differs from that specified in the machine software.

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is rejected.

Probable causes:

  • drive replaced with a non-identical one or not yet configured (Configure drive option);
  • drive configuration lost.

How to resolve:

  1. Check whether the drive has been replaced recently: the replacement must be identical to the original.
  2. Configure the drive (CEMAS technician).

Reset: the alarm clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Configure the drive

How to identify this: the axis drive is not configured, for example following a replacement.

Check:

  1. Check whether the drive has been replaced recently.
  2. Check that the model fitted is the one specified in the wiring diagram.

Remedy: the drive must be configured by CEMAS Elettra personnel: contact support (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15002-3.XX - Mirror (rear/left) - Axle - Power switch

What this means: The circuit breaker (thermal overload) for the mirror drive has tripped.

Effect: The message is not displayed in the Alarm Monitor. The trip can be identified by the Breaker triggered alarm in the mirror axis details (M15101-3.XX): follow the instructions for that item.

Availability: only on IR machines (IR9, IR14, IR20) and HP machines with hot plates (HP9, HP14, HP20, HP-P125).

Circuit breaker (thermal) has tripped

How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.

Check:

  1. Locate the component’s circuit breaker on the wiring diagram and check its position.
  2. Check that the thermal setting corresponds to the diagram.
  3. Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.

Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15002-2.XX - Table - Board - Breaker triggered

What this means: The circuit breaker (thermal) supplying the safety brake on the table axis has tripped: the input of the circuit breaker’s auxiliary contact, enabled in the configuration, is low.

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the brake or its cable (entry Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not reset;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the table brake circuit breaker (electrical maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and the wiring.

Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Circuit breaker (thermal) has tripped

How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.

Check:

  1. Locate the component’s circuit breaker on the wiring diagram and check its position.
  2. Check that the thermal setting corresponds to the diagram.
  3. Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.

Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15103-3.XX - Mirror (rear/left) - Axle - Drive mechanism not accessible

What this means: The PLC is unable to communicate with the mirror axis drive via the field network (PROFINET).

Effect: Alarm (red line). Mirror stationary (drive disabled) and axis not ready: the automatic cycle cannot continue.

Probable causes:

  • drive switched off or without logic power supply (see Drive power-up);
  • network cable disconnected or damaged, or network switch not powered (see Check communication).

How to resolve:

  1. Check under Machine status > Alarm monitor whether a circuit breaker alarm is also active: if so, resolve that first.
  2. Check that the drive’s display or status LEDs are lit (electrical maintenance technician).
  3. Check the network cable: the port LEDs must be lit or flashing (electrical maintenance technician).

Reset: the fault message clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

Safety:

Warning Electric panel: authorised electrical maintenance technician only, with the machine in a safe state as per the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP hot plate machines (HP9, HP14, HP20, HP-P125).

Powering on the drive

How to identify the problem: the drive is not responding to the PLC: the display or status LEDs are off.

Check:

  1. Check that the drive is powered (display or LEDs lit).
  2. Check the drive’s power switches in the electric panel.

Remedy: restore the power supply; if the drive remains off or in error mode, have it checked (by an electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Check the message

How to identify the problem: the drive is switched on but the PLC is not communicating with it.

Check:

  1. Check the drive’s Profinet network cable and the port LED.
  2. Check in Machine Diagnostics > Motor Status that the axis values are updating.

Remedy: Reconnect or replace the network cable (maintenance technician).

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation is reserved for qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15103-2.XX – Table – Beam – Drive not accessible

What this means: The PLC is unable to communicate with the table axis drive via the fieldbus (PROFINET).

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • drive switched off or without logic power supply (see Drive power-on);
  • network cable disconnected or damaged, or network switch not powered (see Check communication).

How to resolve:

  1. Check under Machine status > Alarm monitor whether a circuit breaker alarm is also active: if so, resolve that first.
  2. Check that the drive’s display or status LEDs are lit (electrical maintenance technician).
  3. Check the network cable: the port LEDs must be lit or flashing (electrical maintenance technician).

Reset: the fault message clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

Safety:

Warning Electric panel: authorised electrical maintenance technician only, with the machine in a safe state as per the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Powering on the drive

How to identify the problem: the drive is not responding to the PLC: the display or status LEDs are off.

Check:

  1. Check that the drive is powered (display or LEDs lit).
  2. Check the drive’s power switches in the electric panel.

Remedy: restore the power supply; if the drive remains off or in error mode, have it checked (by an electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Check the message

How to identify the problem: the drive is switched on but the PLC is not communicating with it.

Check:

  1. Check the drive’s Profinet network cable and the port LED.
  2. Check in Machine Diagnostics > Motor Status that the axis values are updating.

Remedy: Reconnect or replace the network cable (maintenance technician).

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation is reserved for qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15303-2.XX - Table - Axis calibration and certification - External load cell error

What this means: during a procedure relating to the force on the table axis, the external load cell used as a reference is in alarm mode. Force-related procedures are carried out by CEMAS Elettra personnel or under their direct supervision.

Effect: Alarm (red line). The procedure is interrupted (status Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.

Probable causes:

  • external load cell disconnected or with a damaged cable (Load cell connection section);
  • faulty external load cell (Load cell functionality section).

How to resolve:

  1. Check the alarms in the External load cell unit under Machine status > Alarm monitor and resolve them.
  2. Check the power supply and network cable of the external load cell (CEMAS technician).
  3. Repeat the procedure.

Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.

Load cell functionality

How to identify this: the external load cell is connected, but the force reading is implausible or immediately goes to full scale.

Check:

  1. Visually inspect the load cell and its cable.
  2. Check that the load cell’s full-scale range is suitable for the force involved in the procedure.
  3. Check that the load cell is correctly positioned, with no lateral loads.

Remedy: replace the load cell if it is damaged or unsuitable; to have the load cell checked, contact CEMAS Elettra support.

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Load cell connection

How to identify the problem: the external load cell is not communicating with the machine.

Check:

  1. Check the power supply to the load cell and its amplifier.
  2. Check the network cable between the load cell and the machine, and the communication LEDs.

Remedy: Reconnect or replace the cables and repeat the procedure.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15003-2.XX – Table – Circuit board – Logic switch

What this means: The circuit breaker (thermal logic) supplying power to the table axis drive control unit has tripped: the auxiliary contact input, enabled in the configuration, is low.

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the drive power supply (item Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not reset;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the logic circuit breaker (electrical maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and the wiring.

Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.

Circuit breaker (thermal) has tripped

How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.

Check:

  1. Locate the component’s circuit breaker on the wiring diagram and check its position.
  2. Check that the thermal setting corresponds to the diagram.
  3. Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.

Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15003-3.XX – Mirror (rear/left) – Axle – Unreferenced axle

What this means: this warning (mirror axis not referenced) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the message appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.

Availability: only on IR machines (IR9, IR14, IR20) and HP machines with hot plates (HP9, HP14, HP20, HP-P125).

Perform a reset

How to identify this: the axis is not referenced (the Referenced indicator is grey in Machine Diagnostics > Motor Status) or its position does not match the actual position.

Check:

  1. Check the Home indicator for the axis in Machine Diagnostics > Motor Status.
  2. Check whether the drive, motor or encoder has been replaced recently.

Remedy: Referencing is carried out manually using the axis’s Home position button in Machine settings > General settings > Tool interfaces (in Machine settings > General settings > Components for gates and sliding tables): this sets the reference position without moving the axis and remains valid even after the machine is switched off. This operation is reserved for CEMAS technicians.

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15103-1.XX - Head - Shaft details - Drive not accessible

1.25.0

What this means: The PLC is unable to communicate with the head axis drive via the field network (PROFINET).

Effect: Alarm (red line). Head drive disabled: axis stationary and not ready; the automatic cycle cannot continue.

Probable causes:

  • drive switched off or without logic power supply (see Drive power-up);
  • network cable disconnected or damaged, or network switch not powered (see Check communication).

How to resolve:

  1. Check under Machine status > Alarm monitor whether a circuit breaker alarm is also active: if so, resolve that first.
  2. Check that the drive’s display or status LEDs are lit (electrical maintenance technician).
  3. Check the network cable: the port LEDs must be lit or flashing (electrical maintenance technician).

Reset: the warning clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

Safety:

Warning Electric panel: authorised electrical maintenance technician only, with the machine in a safe state as per the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15303-1.XX - Head - Axis calibration and certification - External load cell error

1.25.0

What this means: during a procedure involving the force on the head axis, the external load cell used as a reference is in alarm mode. Force procedures are carried out by CEMAS Elettra personnel or under their direct supervision.

Effect: Alarm (red line). The procedure is interrupted (result Interrupted in Machine Diagnostics > Calibrations and Certifications); for the rest of the machine, this is merely a warning.

Probable causes:

  • external load cell disconnected or with a damaged cable (Load cell connection entry);
  • faulty external load cell (Load cell functionality entry).

How to resolve:

  1. Check the alarms in the External load cell unit under Machine status > Alarm monitor and resolve them.
  2. Check the power supply and network cable of the external load cell (CEMAS technician).
  3. Repeat the procedure.

Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15003-1.XX – Head – Shaft – Logic switch

1.25.0

What this means: The circuit breaker (thermal logic) supplying power to the head-axis drive control unit has tripped: the auxiliary contact input, enabled in the configuration, is low.

Effect: Alarm (red line). The head stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the drive power supply (item Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not reset;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the head logic circuit breaker (electrical maintenance technician).
  2. If it trips again, do not force it: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and wiring.

Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a circuit breaker that has tripped.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15004-2.XX - Table - Board - Power switch

What this means: The circuit breaker (thermal overload) supplying power to the drive unit of the table axis has tripped.

Effect: The message is not displayed in the Alarm Monitor. The tripping of the circuit breaker can be identified by the Breaker triggered alarm in the axis details (M15101-2.XX): follow the instructions for that item.

Circuit breaker (thermal) has tripped

How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.

Check:

  1. Locate the component’s circuit breaker on the wiring diagram and check its position.
  2. Check that the thermal setting corresponds to the diagram.
  3. Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.

Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15104-1.XX - Head - Axis Details - Drive hardware error

1.25.0

What this means: the field network diagnostics signal a hardware fault in the head axis drive or one of its modules.

Effect: Alarm (red line). Head drive disabled: axis stationary and not ready; the automatic cycle cannot continue.

Probable causes:

  • fault in the drive’s electronics;
  • unstable logic power supply.

How to resolve:

  1. Read the fault code (Drive fault code) in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis error code entry).
  2. Switch the machine off and on again in accordance with the user manual (maintenance technician).
  3. If the fault reoccurs, report the code to the service department: the drive may need replacing.

Reset: the fault message clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15004-1.XX – Head – Shaft – Power switch

1.25.0

What this means: The circuit breaker (thermal overload) supplying power to the head axis drive has tripped: the auxiliary contact input, enabled in the configuration, is low.

Effect: Alarm (red line). The head stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the motor or its cable (see Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not reset;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the power circuit breaker for the head (electrical maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and wiring.

Reset: the alarm clears automatically when the circuit breaker is closed; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a circuit breaker that has tripped.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15304-2.XX - Table - Axis calibration and certification - Maximum force not achievable

What this means: when the table axis force command is set to 100 per cent, the external load cell measures a value lower than the Maximum force required by the procedure. Force-related procedures are carried out by CEMAS Elettra personnel or under their direct supervision.

Effect: Alarm (red line). The procedure is interrupted (status Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.

Probable causes:

  • The procedure’s Maximum force exceeds that which the axis can deliver (under Axis calibration and certification settings);
  • On hydraulic machines, the maximum pressure of the power unit is set too low (under Set maximum pressure valve);
  • External load cell not calibrated.

How to resolve:

  1. Check the Maximum force under Machine settings > General settings > Tool interfaces, Table tab > Axes > Calibration (CEMAS technician).
  2. On hydraulic machines, check the setting of the maximum pressure valve (maintenance technician).
  3. Repeat the procedure.

Reset: alarm logged; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Control unit and hydraulic circuit: only the maintenance technician, with the machine in a safe state as per the user manual, the pump stopped and the circuit drained. Oil and surfaces may be hot.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.

Axis calibration and certification settings

How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.

Check:

  1. Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
  2. Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).

Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15104-2.XX - Table - Drive - Hardware error

What this means: the field network diagnostics signal a hardware fault in the table axis drive or one of its modules.

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • drive electronics fault;
  • unstable logic power supply.

How to resolve:

  1. Read the fault code (Drive fault code) in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis error code entry).
  2. Switch the machine off and on again in accordance with the user manual (maintenance technician).
  3. If the fault recurs, report the code to the service department: the drive may need replacing.

Reset: the fault message clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machines secured in accordance with the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Axis error code

How to identify it: the axis drive has encountered an error.

Check:

  1. In Machine Diagnostics > Motor Status, open the axis card and tap the i icon.
  2. Read and note down the error code (Drive fault code, Alarms word tab) displayed in the diagnostics pop-up.

Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the error recurs, report the code to CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tool, ensure the machine is safely shut down in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15104-3.XX - Mirror (rear/left) - Axle - Drive hardware fault

What this means: the field network diagnostics signal a hardware fault in the mirror axis drive or one of its modules.

Effect: Alarm (red line). Mirror stationary (drive disabled) and axis not ready: the automatic cycle cannot continue.

Probable causes:

  • fault in the drive’s electronics;
  • unstable logic power supply.

How to resolve:

  1. Read the fault code (Drive fault code) in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis error code entry).
  2. Switch the machine off and on again in accordance with the user manual (maintenance technician).
  3. If the fault recurs, report the code to the service department: the drive may need replacing.

Reset: the fault message clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP hot plate machines (HP9, HP14, HP20, HP-P125).

Axis error code

How to identify it: the axis drive has encountered an error.

Check:

  1. In Machine Diagnostics > Motor Status, open the axis card and tap the i icon.
  2. Read and note down the error code (Drive fault code, Alarms word tab) displayed in the diagnostics pop-up.

Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the error recurs, report the code to CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tool, ensure the machine is safely shut down in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15304-1.XX - Head - Axis calibration and certification - Maximum force not achievable

1.25.0

What this means: when the head axis force command is set to 100 per cent, the external load cell measures a value lower than the Maximum force required by the procedure. Force-related procedures are carried out by CEMAS Elettra personnel or under their direct supervision.

Effect: Alarm (red line). The procedure is interrupted (result Interrupted in Machine Diagnostics > Calibrations and Certifications); for the rest of the machine, this is merely a warning.

Probable causes:

  • The procedure’s maximum force exceeds the force the axis can deliver (under Axis calibration and certification settings);
  • External load cell not calibrated.

How to resolve:

  1. Check the Maximum force in Machine settings > General settings > Tool interfaces, Head tab > Axes > Calibration (CEMAS technician).
  2. Repeat the procedure.

Reset: alarm stored; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15005-1.XX – Head – Shaft – Incorrect contact position

1.25.0

What this means: during welding force adjustment, the position of the head moves outside the permitted range: more than 10 millimetres (mm) above or 30 mm below the starting height, derived from Workpiece contact (fixed values). Not checked during certification and capability assessment.

Effect: Alarm (red line). The head stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • Incorrect Workpiece contact height in Tool settings > Positions (Workpiece contact height setting);
  • Missing, duplicate, incorrectly positioned workpieces or foreign objects in the cavities (Correct workpiece positioning);
  • parts different from those intended for the fitted tools.

How to resolve:

  1. Check the parts in the cavities: ensure they are present, correct, fully inserted and free from foreign objects.
  2. Compare the position at contact (under Machine Diagnostics > Motor Status) with Part Contact.
  3. If the dimension is incorrect, have it corrected by the person responsible for the tool and run a test cycle.

Reset: alarm logged; clear it using Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and hot plate HP (HP9, HP14, HP20, HP-P125).

M15105-1.XX - Head - Axis Details - Drive Alarm

1.25.0

What this means: The head axis drive has encountered an error: it has detected a problem with the motor, the encoder, the power supply or the movement. This error is not signalled when safety guards are open or the safety light curtain is in alarm mode.

Effect: Alarm (red line). Head drive disabled: axis stopped and not ready; the automatic cycle cannot continue.

Probable causes:

  • overload or obstructed movement;
  • motor or drive overheating;
  • damaged encoder or motor cables.

How to resolve:

  1. Read the fault code (Drive fault code) in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis error code entry).
  2. Check that nothing is obstructing movement and that the motor has not overheated.
  3. Press the Reset button on the Alarm Monitor; if the fault reoccurs, report the code to support.

Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15305-2.XX - Table - Axis calibration and certification - Not calibrated

What this means: The table axis force calibration is invalid: it has never been carried out, was interrupted, or was cancelled by a machine initialisation.

Effect: Warning (yellow line). The axis is not ready: the automatic cycle cannot start.

Probable causes:

  • new machine or one that has just been initialised;
  • last calibration was interrupted (entry Calibration not completed).

How to resolve:

  1. Check the result of the last calibration in Machine Diagnostics > Calibrations and Certifications, Table tab > Calibration.
  2. Perform the calibration via Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration (CEMAS technician).

Reset: the warning clears automatically once calibration is complete.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra S.r.l. personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Calibration not completed

How to identify this: under Machine Diagnostics > Calibrations and Certifications, Table tab > Calibration, the result is Interrupted or Not performed.

Check:

  1. Check the date and result of the last calibration.
  2. Check Machine Status > Alarm Monitor for the alarms that caused the calibration to be interrupted.

Remedy: once the causes have been rectified, the calibration must be repeated by CEMAS Elettra personnel or under their supervision.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15305-1.XX - Head - Axis calibration and certification - Uncalibrated

1.25.0

What this means: The calibration of the head axis force is invalid: it has never been carried out, was interrupted, or was cancelled by a machine initialisation.

Effect: Warning (yellow line). The axis is not ready: the automatic cycle cannot start.

Probable causes:

  • new machine or one that has just been initialised;
  • last calibration was interrupted (entry Calibration not completed).

How to resolve:

  1. Check the result of the last calibration in Machine Diagnostics > Calibrations and Certifications, Head tab > Calibration.
  2. Perform the calibration via Machine Settings > General Settings > Tool Interfaces, Head tab > Axes > Calibration (CEMAS technician).

Reset: the message clears automatically once calibration is complete.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra S.r.l. personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate (HP9, HP14, HP20, HP-P125).

M15105-3.XX - Mirror (rear/left) - Axle - Activation alarm

What this means: The mirror axis drive has encountered an error: it has detected a problem with the motor, the encoder, the power supply or the movement. This error is not signalled when safety guards are open or the safety light curtain is in alarm mode.

Effect: Alarm (red line). Mirror stationary (drive disabled) and axis not ready: the automatic cycle cannot continue.

Probable causes:

  • overload or obstructed movement;
  • motor or drive overheating;
  • damaged encoder or motor cables.

How to resolve:

  1. Read the fault code (Drive fault code) in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis error code entry).
  2. Check that nothing is obstructing movement and that the motor is not overheating.
  3. Press the Reset button on the Alarm Monitor; if the fault reoccurs, report the code to support.

Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP machines with hot plates (HP9, HP14, HP20, HP-P125).

Axis error code

How to identify it: the axis drive has encountered an error.

Check:

  1. In Machine Diagnostics > Motor Status, open the axis card and tap the i icon.
  2. Read and note down the error code (Drive fault code, Alarms word tab) displayed in the diagnostics pop-up.

Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the error recurs, report the code to CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tool, ensure the machine is safely shut down in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15105-2.XX - Table - Shaft - Drive alarm

What this means: The table axis drive has encountered an error: it has detected a problem with the motor, the encoder, the power supply or the movement. This error is not signalled when safety guards are open or the safety light curtain is in alarm mode.

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • overload or obstructed movement;
  • motor or drive overheating;
  • damaged encoder or motor cables.

How to resolve:

  1. Read the fault code (Drive fault code) in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis error code entry).
  2. Check that nothing is obstructing movement and that the motor is not overheating.
  3. Press the Reset button on the Alarm Monitor; if the fault reoccurs, report the code to support.

Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; only carry out manual movements when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Axis error code

How to identify it: the axis drive has encountered an error.

Check:

  1. In Machine Diagnostics > Motor Status, open the axis card and tap the i icon.
  2. Read and note down the error code (Drive fault code, Alarms word tab) displayed in the diagnostics pop-up.

Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the error recurs, report the code to CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tool, ensure the machine is safely shut down in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15005-2.XX - Table - Beam - Incorrect contact position

What this means: during welding force adjustment, the table position moves outside the permitted range: more than 10 millimetres (mm) above or 30 mm below the starting height, derived from Workpiece contact (fixed values). Not checked during certification and capability assessment.

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • Incorrect Workpiece contact dimension in Tool settings > Positions (Workpiece contact dimension setting);
  • Missing, duplicate, incorrectly positioned workpieces or foreign objects in the cavities (Correct workpiece positioning);
  • parts different from those intended for the fitted tools.

How to resolve:

  1. Check the parts in the cavities: ensure they are present, correct, fully inserted and free from foreign objects.
  2. Compare the position at contact (under Machine Diagnostics > Motor Status) with Part Contact.
  3. If the dimension is incorrect, have it corrected by the person responsible for the tools and run a test cycle.

Reset: alarm logged; clear it using Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.

Setting the contact height for workpieces

How to recognise it: the alarm appears during every cycle with correct workpieces, always at the same stage.

Check:

  1. In Machine Diagnostics > Motor Status, read the table position when the workpieces make contact.
  2. Compare this with the Workpiece contact dimension in Tool settings > Positions, Table tab: the difference must be between 30 mm below and 10 mm above.

Remedy: the tool manager corrects the dimension and runs a test cycle.

Correct positioning of parts

How to recognise it: the alarm only appears on certain cycles; the parts appear raised, warped or missing.

Check:

  1. Check that the parts are those specified for the tool.
  2. Check that they are fully inserted into the cavities and that there are no foreign objects or debris.

Remedy: the operator repositions the parts or cleans the cavities and repeats the cycle.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15306-1.XX - Head - Axis calibration and certification - Calibration in progress

1.25.0

What this means: The head axis calibration procedure is in progress.

Effect: Info (grey line). Information: no action required.

How to resolve:

  1. Wait for the procedure to finish and check the result under Machine Diagnostics > Calibrations and Certifications.

Resolution: the message disappears automatically at the end of the procedure.

Availability: only on machines with a moving print head: IR (IR9, IR14, IR20) and HP hot plate (HP9, HP14, HP20, HP-P125).

M15106-3.XX – Mirror (rear/left) – Axle – Technology alarm

What this means: the PLC’s motion control for the mirror axis has signalled an error, such as a tracking error (the axis is not following the commanded position), a software limit being exceeded, or a referencing error. This error is not signalled when the safety guards are open or the safety barrier is in alarm.

Effect: Alarm (red line). Mirror stationary (drive disabled) and axis not ready: the automatic cycle cannot continue.

Probable causes:

  • movement braked or obstructed;
  • drive in error or not ready;
  • commanded position outside the axis limits.

How to resolve:

  1. Read the active bits of the Alarms word card in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis status code entry).
  2. Resolve any other drive alarms.
  3. Press the Reset button on the Alarm Monitor and attempt a manual movement via Machine Diagnostics > Manual Movements, Machine tab > Mirror.

Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; only perform manual movements when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP machines with hot plates (HP9, HP14, HP20, HP-P125).

Axis status coding

How to recognise it: the axis is stationary in alarm mode and its drive signals an abnormal status.

Check:

  1. In Machine Diagnostics > Motor Status, open the axis card and tap the i icon: the diagnostics pop-up displays the drive’s current statuses, errors and warnings.
  2. Make a note of the statuses and errors displayed.

Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the fault persists, report the noted data to CEMAS Elettra support.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15006-2.XX - Table - Beam - Upper limit reached

What this means: with the current tool in place and outside the tool change cycle, the table axis has reached the Upper limit set for the tool in Tool Settings > Positions (hysteresis 1 mm).

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • Upper limit set too low compared to the other cycle dimensions (Upper limit setting option);
  • workpieces lower than expected or missing, causing the axis to rise beyond the contact height;
  • tools different from those specified in the loaded parameters.

How to resolve:

  1. Check that the workpieces are present and correct.
  2. Check in Equipment Settings > Positions that the Upper limit is higher than Workpiece contact and the other working dimensions; this limit can only be modified by CEMAS personnel.
  3. Check that the loaded parameters correspond to the fitted tools.

Reset: alarm stored; clear it by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.

Setting the upper limit

How to recognise it: the upper limit alarm appears with correct parts, always at the same stage of the cycle.

Check:

  1. Check in Tool Settings > Positions, under the Table tab, that the Upper Limit is higher than Workpiece Contact and the other working dimensions.

Remedy: CEMAS personnel correct the Upper limit (which can only be modified by CEMAS) and the tool manager checks the other dimensions.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15106-2.XX – Table – Beam – Technological object alarm

What this means: The PLC’s motion control for the table axis has signalled an error, such as a tracking error (the axis is not following the commanded position), a software limit being exceeded, or a referencing error. This error is not signalled when the safety guards are open or the safety light curtain is in alarm mode.

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • movement braked or obstructed;
  • drive in error or not ready;
  • commanded position outside the axis limits.

How to resolve:

  1. Read the active bits of the Alarms word card in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis status code entry).
  2. Resolve any other drive alarms.
  3. Press the Reset button on the Alarm Monitor and attempt a manual movement via Machine Diagnostics > Manual Movements, the Machine tab, or using the arrows in the right-hand column.

Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; only perform manual movements when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Axis status coding

How to recognise it: the axis is stationary in alarm mode and its drive signals an abnormal status.

Check:

  1. In Machine Diagnostics > Motor Status, open the axis card and tap the i icon: the diagnostics pop-up displays the drive’s current statuses, errors and warnings.
  2. Make a note of the statuses and errors displayed.

Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the fault persists, report the noted data to CEMAS Elettra support.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15006-1.XX – Head – Axis – Upper limit reached

1.25.0

What this means: with the current tool fitted and outside the tool change cycle, the head axis has reached the Upper limit set for the tool in Tool Settings > Positions (hysteresis 1 mm).

Effect: Alarm (red line). The head stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • Upper limit set too low compared to the other cycle dimensions (Upper limit setting option);
  • workpieces lower than expected or missing, causing the axis to rise beyond the contact height;
  • tools different from those specified in the loaded parameters.

How to resolve:

  1. Check that the workpieces are present and correct.
  2. Check in Equipment Settings > Positions that the Upper limit is higher than Workpiece contact and the other working dimensions; this limit can only be modified by CEMAS personnel.
  3. Check that the loaded parameters correspond to the fitted tools.

Reset: alarm stored; clear it by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and hot plate HP (HP9, HP14, HP20, HP-P125).

M15106-1.XX – Head – Axis Details – Technical Object Alarm

1.25.0

What this means: the PLC’s motion control for the head axis has signalled an error, such as a tracking error (the axis is not following the commanded position), a software limit being exceeded, or a referencing error. This error is not signalled when the safety guards are open or the safety light curtain is in alarm mode.

Effect: Alarm (red line). Head drive disabled: axis stopped and not ready; the automatic cycle cannot continue.

Probable causes:

  • movement braked or obstructed;
  • drive in error or not ready;
  • commanded position outside the axis limits.

How to resolve:

  1. Read the active bits of the Alarms word card in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis status code entry).
  2. Resolve any other drive alarms.
  3. Press the Reset button on the Alarm Monitor and attempt a manual movement via Machine Diagnostics > Manual Movements, Machine tab > Head.

Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; only perform manual movements when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15306-2.XX - Table - Axis calibration and certification - Calibration in progress

What this means: The table axis force calibration procedure is in progress.

Effect: Info (grey line). Information: no action required.

How to resolve:

  1. Wait for the procedure to finish and check the result under Machine Diagnostics > Calibrations and Certifications.

Resolution: the message disappears automatically once the procedure is complete.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15007-2.XX – Table – Beam – Machine load cell error

What this means: the value from the internal load cell, which measures the force on the table’s axis, is outside the valid range (0–100 %).

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • load cell cable or connector disconnected or damaged (see Check electrical connection);
  • load cell damaged, for example due to an overload (see Load cell functionality).

How to resolve:

  1. Read the load cell value under Machine diagnostics > Motor status: when the table is stationary and unloaded, it must be close to zero and never negative.
  2. Check the load cell cable and M12 connector (maintenance technician).
  3. If the value remains abnormal whilst the wiring is intact, the load cell must be replaced (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Load cell functionality

How to identify this: the load cell value under Machine Diagnostics > Motor Status is negative, constant or exceeds the maximum force of the welding machine.

Check:

  1. With the table stationary and no force applied, read the value in Machine Diagnostics > Motor Status: it should be close to zero.
  2. Apply force in manual mode: the value should increase steadily.

Remedy: if the value is abnormal whilst the wiring is intact, the load cell must be replaced: contact CEMAS Elettra support.

Check the electrical connection

How to identify the problem: the load cell value in Machine Diagnostics > Motor Status is missing or fluctuates erratically.

Check:

  1. Check that the load cell cable is intact and not pinched (maintenance technician).
  2. Check that the M12 connector is properly inserted and tightened (maintenance technician).

Remedy: the maintenance technician must re-establish the connection or replace the cable.

Warning Electric panel: authorised electrical maintenance technician only, with the machine in a safe state as per the user manual. Do not repeatedly reset a circuit breaker that has tripped.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15307-2.XX - Table - Axis calibration and certification - Certification in progress

What this means: The certification procedure for the table’s axial force is in progress.

Effect: Info (grey line). Information: no action required.

How to resolve:

  1. Wait for the procedure to finish and check the result under Machine Diagnostics > Calibrations and Certifications.

Resolution: the message disappears automatically once the procedure has finished.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15107-1.XX - Head - Spindle Details - Positive overtravel alarm

1.25.0

What this means: the positive over-travel limit switch on the head axis is active (if enabled): the axis has moved beyond its working travel.

Effect: Alarm (red line). Head drive disabled: axis stopped and not ready; the automatic cycle cannot continue.

Probable causes:

  • axis moved beyond its travel range in manual mode or with movement constraints disabled;
  • lost or incorrect home position;
  • limit switch faulty, out of calibration or disconnected (see Faulty sensors).

How to resolve:

  1. Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab > Head (Release Overtravel option).
  2. Whilst the axis is moving, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
  3. If the value in Machine Diagnostics > Motor Status does not match the actual position, have the axis re-referenced (CEMAS technician).

Reset: alarm stored; clear it by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15007-1.XX – Head – Axle – Machine load cell error

1.25.0

What this means: this message (internal load cell error in the head) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the message appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate (HP9, HP14, HP20, HP-P125).

M15107-3.XX - Mirror (rear/left) - Axle - Positive overtravel alarm

What this means: the positive over-travel limit switch on the mirror axis is active (if enabled): the axis is beyond its working travel.

Effect: Alarm (red line). Mirror stationary (drive disabled) and axis not ready: the automatic cycle cannot continue.

Probable causes:

  • axis moved beyond its travel range in manual mode or with movement constraints disabled;
  • lost or incorrect home position;
  • limit switch faulty, out of calibration or disconnected (see Faulty sensors).

How to resolve:

  1. Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab > Mirror (see Release Overtravel).
  2. With the axis in motion, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
  3. If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP machines with hot plates (HP9, HP14, HP20, HP-P125).

Release the overrun

How to recognise this: the axis has reached the over-travel limit, beyond its normal travel; continuing would damage the machine.

Check:

  1. In Machine Diagnostics > Manual Movements, on the Machine tab, check the direction in which the axis has reached the overtravel limit.
  2. Check that the overtravel sensor is not faulty or misaligned.

Remedy: move the axis by hand in the opposite direction until the sensor is released, then press Reset; if the axis does not move, contact CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15107-2.XX - Table - Beam - Positive overtravel alarm

What this means: the positive over-travel limit switch on the table axis is active (if enabled): the axis has moved beyond its working travel.

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic and tool change functions blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • axis moved beyond its travel limit in manual mode or with motion constraints disabled;
  • home position lost or incorrect;
  • limit switch faulty, out of calibration or disconnected (see Faulty sensors).

How to resolve:

  1. Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab, or using the arrows in the right-hand column (see Release Overtravel).
  2. With the axis in motion, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
  3. If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.

Release the overrun

How to recognise this: the axis has reached the over-travel limit, beyond its normal travel; continuing would damage the machine.

Check:

  1. In Machine Diagnostics > Manual Movements, on the Machine tab, check the direction in which the axis has reached the overtravel limit.
  2. Check that the overtravel sensor is not faulty or misaligned.

Remedy: move the axis by hand in the opposite direction until the sensor is released, then press Reset; if the axis does not move, contact CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15307-1.XX - Head - Axis calibration and certification - Certification in progress

1.25.0

What this means: The head axis force certification procedure is in progress.

Effect: Info (grey line). Information: no action required.

How to resolve:

  1. Wait for the procedure to finish and check the result under Machine Diagnostics > Calibrations and Certifications.

Reset: the message disappears automatically at the end of the procedure.

Availability: only on machines with a moving print head: IR (IR9, IR14, IR20) and HP hot plate (HP9, HP14, HP20, HP-P125).

M15108-2.XX - Table - Beam - Negative overtravel alarm

What this means: the negative over-travel limit switch for the table axis is active (if enabled): the axis has moved beyond its working travel.

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic and tool change functions blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • axis moved beyond its travel range in manual mode or with motion constraints disabled;
  • homing lost or incorrect;
  • limit switch faulty, out of calibration or disconnected (see Sensors not working).

How to resolve:

  1. Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab, or using the arrows in the right-hand column (see Release Overtravel).
  2. With the axis in motion, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
  3. If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.

Release the overrun

How to recognise this: the axis has reached the over-travel limit, beyond its normal travel; continuing would damage the machine.

Check:

  1. In Machine Diagnostics > Manual Movements, on the Machine tab, check the direction in which the axis has reached the overtravel limit.
  2. Check that the overtravel sensor is not faulty or misaligned.

Remedy: move the axis by hand in the opposite direction until the sensor is released, then press Reset; if the axis does not move, contact CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15308-1.XX – Head – Axis calibration and certification – Capability assessment in progress

1.25.0

What this means: The head spindle capability procedure is in progress.

Effect: Info (grey line). Information: no action required.

How to resolve:

  1. Wait for the procedure to finish and check the result under Machine Diagnostics > Calibrations and Certifications.

Resolution: the message disappears automatically at the end of the procedure.

Availability: only on machines with a moving print head: IR (IR9, IR14, IR20) and HP hot plate (HP9, HP14, HP20, HP-P125).

M15008-1.XX – Head – Axis – Transducer position error

1.25.0

What this means: on electric axes with linear transducers, the position of the head as read by the encoder differs by more than 10 mm from that of the transducer for more than 15 ms (fixed values).

Effect: Alarm (red line). The head stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • axis home position lost or set to an incorrect value (Perform zeroing option);
  • linear transducer faulty, disconnected or with the magnet displaced;
  • mechanical slippage between the motor and the axis.

How to resolve:

  1. In Machine Diagnostics > Motor Status, compare the position of the axis with that of the transducers.
  2. If there are any transducer alarms, resolve them first.
  3. Perform homing using the Home position button for the axis in Machine settings > General settings > Tool interfaces, Head tab: with the machine in manual mode, set the reference position without moving the axis (CEMAS technician).

Reset: clear this using the Reset button on the Alarm Monitor or by performing axis homing; then select Home position (right-hand column) and Automatic cycle to restart.

Safety:

Warning Before working on moving axes and components, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15008-2.XX – Table – Axis – Transducer position error

What this means: on electric axes with linear transducers, the table position read by the encoder differs by more than 10 mm from that of the transducer for more than 15 ms (fixed values).

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • axis home position lost or set to an incorrect value (Perform zeroing option);
  • linear transducer faulty, disconnected or with the magnet displaced;
  • mechanical slippage between the motor and the axis.

How to resolve:

  1. In Machine Diagnostics > Motor Status, compare the position of the axis with that of the transducers.
  2. If there are any transducer alarms, resolve them first.
  3. Perform homing using the Home position button for the axis in Machine settings > General settings > Tool interfaces, Table tab: with the machine in manual mode, set the reference position without moving the axis (CEMAS technician).

Reset: clear the alarm using the Reset button on the Alarm Monitor or by performing axis homing; then select Home position (right-hand column) and Automatic cycle to restart.

Safety:

Warning Before working on moving axes and components, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.

Perform a reset

How to identify this: the axis is not referenced (the Referenced indicator is grey in Machine Diagnostics > Motor Status) or its position does not match the actual position.

Check:

  1. Check the Home indicator for the axis in Machine Diagnostics > Motor Status.
  2. Check whether the drive, motor or encoder has been replaced recently.

Remedy: Referencing is carried out manually using the axis’s Home position button in Machine settings > General settings > Tool interfaces (in Machine settings > General settings > Components for gates and sliding tables): this sets the reference position without moving the axis and remains valid even after the machine is switched off. This operation is reserved for CEMAS technicians.

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15108-1.XX - Head - Axis Details - Negative overtravel alarm

1.25.0

What this means: the negative over-travel limit switch on the head axis is active (if enabled): the axis has exceeded its working travel.

Effect: Alarm (red line). Head drive disabled: axis stopped and not ready; the automatic cycle cannot continue.

Probable causes:

  • axis moved beyond its travel range in manual mode or with motion constraints disabled;
  • lost or incorrect home position;
  • limit switch faulty, out of calibration or disconnected (see Faulty sensors).

How to resolve:

  1. Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab > Head (Release Overtravel section).
  2. Whilst the axis is moving, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
  3. If the value in Machine Diagnostics > Motor Status does not match the actual position, have the axis re-referenced (CEMAS technician).

Reset: alarm stored; clear it using Reset in the Alarm Monitor after rectifying the cause (limit switch released).

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15308-2.XX – Table – Axis calibration and certification – Capability assessment in progress

What this means: The table axis force capability procedure is in progress.

Effect: Info (grey line). Information: no action required.

How to resolve:

  1. Wait for the procedure to finish and check the result under Machine Diagnostics > Calibrations and Certifications.

Resolution: the message disappears automatically once the procedure has finished.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15108-3.XX - Mirror (rear/left) - Axle - Negative overtravel alarm

What this means: the negative over-travel limit switch on the mirror axis is active (if enabled): the axis is beyond its working travel.

Effect: Alarm (red line). Mirror stationary (drive disabled) and axis not ready: the automatic cycle cannot continue.

Probable causes:

  • axis moved beyond its travel range in manual mode or with motion constraints disabled;
  • home position lost or incorrect;
  • limit switch faulty, out of calibration or disconnected (see Faulty sensors).

How to resolve:

  1. Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab > Mirror (see Release Overtravel).
  2. With the axis in motion, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
  3. If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP hot plate machines (HP9, HP14, HP20, HP-P125).

Release the overrun

How to recognise this: the axis has reached the over-travel limit, beyond its normal travel; continuing would damage the machine.

Check:

  1. In Machine Diagnostics > Manual Movements, on the Machine tab, check the direction in which the axis has reached the overtravel limit.
  2. Check that the overtravel sensor is not faulty or misaligned.

Remedy: move the axis by hand in the opposite direction until the sensor is released, then press Reset; if the axis does not move, contact CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15009-2.XX - Table - Axis - Handling timeout

What this means: during positioning, the table axis remains outside the tolerance of the commanded position for more than 3 seconds (s) on the electric axes and 6 s on the hydraulic axes; these are fixed values.

Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • mechanical obstruction to movement (see Movement of the mobile platen);
  • insufficient available force, brake not released or drive restricted;
  • on hydraulic machines: shut-off valves, speed control valve, proportional valve or pump not functioning (related items).

How to resolve:

  1. Check that nothing is obstructing movement.
  2. Check for other active alarms in Machine status > Alarm monitor (brake, drive, hydraulic power unit).
  3. Test the movement manually via Machine Diagnostics > Manual Movements, the Machine tab or using the arrows in the right-hand column: the axis must move smoothly.
  4. On hydraulic machines, check the pump and valves on the power unit (maintenance technician).

Reset: alarm logged; clear by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.
Warning Control unit and hydraulic circuit: only the maintenance technician, with the machine secured in accordance with the user manual, the pump stopped and the circuit drained. Oil and surfaces may be hot.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.

Movement of the mobile platen

How to recognise this: the table does not move or stops before reaching the commanded position.

Check:

  1. Check that there are no objects in the work area blocking the table.
  2. Test the movement manually via Machine Diagnostics > Manual Movements, the Machine tab or using the arrows in the right-hand column.

Remedy: remove the obstruction before moving the table again; if the table remains jammed for no apparent reason, contact CEMAS Elettra support.

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; only perform manual movements when the work area is clear.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15309-1.XX - Head - Axis calibration and certification - Axis locked

1.25.0

What this means: during a force test, the force on the head axis was increased to 100 per cent without the axis moving by at least 0.5 mm (fixed value).

Effect: Alarm (red line). The procedure is interrupted (result Interrupted in Machine Diagnostics > Calibrations and Certifications); for the rest of the machine, this is merely a warning.

Probable causes:

  • axis at end stop or external load cell incorrectly positioned;
  • brake not released or limited actuation.

How to resolve:

  1. Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms associated with it (CEMAS technician).
  2. Check for any other active alarms in Machine Status > Alarm Monitor.
  3. Repeat the procedure.

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15309-2.XX - Table - Axis calibration and certification - Axis locked

What this means: during a force measurement procedure, the force on the table axis was increased to 100 per cent without the axis moving by at least 0.5 mm (fixed value).

Effect: Alarm (red line). The procedure is interrupted (result Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.

Probable causes:

  • axis at end stop or external load cell incorrectly positioned;
  • brake not released or limited actuation.

How to resolve:

  1. Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms on it (CEMAS technician).
  2. Check the other active alarms in Machine Status > Alarm Monitor.
  3. Repeat the procedure.

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15009-1.XX – Head – Axis – Movement timeout

1.25.0

What this means: during positioning, the head axis remains outside the tolerance of the commanded dimension for more than 3 seconds (s), fixed values.

Effect: Alarm (red line). The head stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.

Probable causes:

  • mechanical obstruction to movement (see Movement of the mobile platen);
  • insufficient available force, brake not released or drive restricted.

How to resolve:

  1. Check that nothing is obstructing movement.
  2. Check for other active alarms in Machine Status > Alarm Monitor (brake, drive, hydraulic control unit).
  3. Test the movement in manual mode via Machine Diagnostics > Manual Movements, Machine tab > Head: the axis must move smoothly.
  4. On hydraulic machines, check the pump and valves on the power unit (maintenance technician).

Reset: alarm logged; clear by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate models (HP9, HP14, HP20, HP-P125).

M15010-2.XX – Table – Beam – Upper limit force scaling

What this means: this warning (force exceeding the upper limit) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the warning appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.
Axis calibration and certification settings

How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.

Check:

  1. Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
  2. Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).

Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Perform calibration

How to recognise this: the table force does not match the set value, or the calibration is invalid.

Check:

  1. Check under Machine Diagnostics > Calibrations and Certifications, Table tab > Calibration, for the result and date of the last calibration.
  2. Check whether the calibration has been modified manually (Manually edited calibration field).

Remedy: the CEMAS technician carries out the calibration via Machine Settings > General Settings > Tool Interfaces, under the Table tab > Axes > Calibration using the external load cell and checks the result.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15010-1.XX – Head – Shaft – Upper limit force scaling

1.25.0

What this means: this warning (force exceeding the upper limit) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the warning appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate (HP9, HP14, HP20, HP-P125).

M15011-1.XX – Head – Shaft – Lower limit force scaling

1.25.0

What this means: this warning (force falling below the lower limit) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the warning appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate (HP9, HP14, HP20, HP-P125).

M15011-2.XX - Table - Beam - Lower limit force scaling

What this means: this warning (force falling below the lower limit) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the warning appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.
Axis calibration and certification settings

How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.

Check:

  1. Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
  2. Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).

Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Perform calibration

How to recognise this: the table force does not match the set value, or the calibration is invalid.

Check:

  1. Check under Machine Diagnostics > Calibrations and Certifications, Table tab > Calibration, for the result and date of the last calibration.
  2. Check whether the calibration has been modified manually (Manually edited calibration field).

Remedy: the CEMAS technician carries out the calibration via Machine Settings > General Settings > Tool Interfaces, under the Table tab > Axes > Calibration using the external load cell and checks the result.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M15012-1.XX – Head – Axis – Unreferenced axis

1.25.0

What this means: the head axis is powered but does not have a reference height: the positions read are unreliable and the axis cannot perform height-controlled movements.

Effect: Alarm (red line). The head drive remains disabled and the axis is not ready: the automatic cycle cannot start.

Probable causes:

  • motor, encoder or drive replaced;
  • reference lost following a fault in the encoder or its power supply.

How to resolve:

  1. Check the head’s Referenced indicator in Machine Diagnostics > Motor Status: grey indicates the axis is not referenced.
  2. Perform referencing using the Home position button for the axis in Machine settings > General settings > Tool interfaces, Head tab: with the machine in manual mode, set the reference position without moving the axis (CEMAS technician).

Reset: this is automatically cleared after homing.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra S.r.l. personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on machines with a moving head: IR (IR9, IR14, IR20) and HP hot plate (HP9, HP14, HP20, HP-P125).

M15014-2.XX – Table – Beam – Unreferenced beam

What this means: the table axis is powered but does not have a reference height: the positions read are unreliable and the axis cannot perform height-controlled movements.

Effect: Alarm (red line). The table drive remains disabled and the axis is not ready: the automatic cycle and tool change cannot start.

Probable causes:

  • motor, encoder or drive replaced (see Perform zeroing);
  • reference lost following a fault in the encoder or its power supply.

How to resolve:

  1. Check the table’s Referenced indicator in Machine Diagnostics > Motor Status: grey indicates the axis is not referenced.
  2. Perform referencing using the Home position button for the axis in Machine settings > General settings > Tool interfaces, Table tab: with the machine in manual mode, set the reference position without moving the axis; if linear transducers are present, the position is taken from these (CEMAS technician).

Reset: this is automatically cleared after homing.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra S.r.l. personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Perform a reset

How to identify this: the axis is not referenced (the Referenced indicator is grey in Machine Diagnostics > Motor Status) or its position does not match the actual position.

Check:

  1. Check the Home indicator for the axis in Machine Diagnostics > Motor Status.
  2. Check whether the drive, motor or encoder has been replaced recently.

Remedy: Referencing is carried out manually using the axis’s Home position button in Machine settings > General settings > Tool interfaces (in Machine settings > General settings > Components for gates and sliding tables): this sets the reference position without moving the axis and remains valid even after the machine is switched off. This operation is reserved for CEMAS technicians.

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

External load cell

Alarms from the external load cell, the reference instrument connected to the machine for calibration, certification and force capability; the results can be found under Machine Diagnostics > Calibrations and Certifications.

M16000-0.XX – External load cell – Full scale reached

What this means: the force measured by the external load cell has remained outside the load cell’s measurement range for 3 s. This check is active when the external load cell is enabled for calibration, certification or force capability testing.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked. The current procedure is interrupted.

Probable causes:

  • load cell with a full-scale range lower than the applied force (Inappropriate load cell);
  • load cell faulty or not calibrated (Load cell functionality).

How to resolve:

  1. Check that the load cell’s full-scale range is adequate for the machine’s maximum force.
  2. Check that the load cell is correctly positioned and free from lateral loads.
  3. Replace the load cell with a suitable one and repeat the procedure.

Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Load cell functionality

How to identify this: the external load cell is connected, but the force reading is implausible or immediately goes to full scale.

Check:

  1. Visually inspect the load cell and its cable.
  2. Check that the load cell’s full-scale range is suitable for the force involved in the procedure.
  3. Check that the load cell is correctly positioned, with no lateral loads.

Remedy: replace the load cell if it is damaged or unsuitable; to have the load cell checked, contact CEMAS Elettra support.

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Unsuitable load cell

How to recognise it: the full-scale alarm always occurs at the highest forces specified in the procedure.

Check:

  1. Read the full-scale value on the load cell nameplate.
  2. Compare it with the machine’s maximum force.

Remedy: use a load cell with a full-scale value greater than the machine’s maximum force and repeat the procedure.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M16001-0.XX – External load cell – Communication

What this means: The external load cell is not responding to the welding machine’s PLC via the network. This check is active when the external load cell is enabled for calibration, certification or force capability testing.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The current procedure is interrupted.

Probable causes:

  • Load cell not powered or network cable disconnected (Load cell connection).

How to resolve:

  1. Check the power supply to the load cell and its amplifier.
  2. Check the network cable between the load cell and the machine.
  3. Repeat the procedure.

Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Load cell connection

How to identify the problem: the external load cell is not communicating with the machine.

Check:

  1. Check the power supply to the load cell and its amplifier.
  2. Check the network cable between the load cell and the machine, and the communication LEDs.

Remedy: Reconnect or replace the cables and repeat the procedure.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M16002-0.XX – External load cell – Profinet disconnection

What this means: Profinet communication with the external load cell has been interrupted. This check is active when the external load cell is enabled for calibration, certification or force capability testing.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The current procedure is interrupted.

Probable causes:

  • Profinet cable disconnected or damaged, load cell not powered (Load cell connection).

How to resolve:

  1. Check the load cell’s power supply and LEDs.
  2. Check the Profinet cable and connectors.
  3. Repeat the procedure.

Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Load cell connection

How to identify the problem: the external load cell is not communicating with the machine.

Check:

  1. Check the power supply to the load cell and its amplifier.
  2. Check the network cable between the load cell and the machine, and the communication LEDs.

Remedy: Reconnect or replace the cables and repeat the procedure.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Control inputs

Alarms from the machine input commands, configurable input signals, including those received from the Smart accessory. These are configured under Machine Settings > General Settings > Components, on the Input Commands tab.

M17000-0.XX - Control inputs - Incorrect signal address

What this means: the machine’s input command, configured as a Smart Accessory signal, has a signal number outside the range 1–20. This check applies only to Smart Accessory commands, provided the Smart Accessory is connected; digital commands do not trigger the alarm. In the code, XX is the input command number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • Invalid Smart Accessory signal (Reset the commands).

How to resolve:

  1. Check command XX in Machine settings > General settings > Components, Input commands tab.
  2. Correct the signal number (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Reset the controls

How to recognise it: the alarm appears on a machine command associated with a signal from the Smart accessory.

Check:

  1. Check the command in Machine Settings > General Settings > Components, under the Input Commands tab, or in Machine Settings > General Settings > Components, under the Output Commands tab.
  2. Check that the signal number is between 1 and 20.

Remedy: correct the signal number (CEMAS technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Command outputs

Alarms from the machine output commands, configurable output signals, which can also be sent to the Smart accessory. These are configured under Machine Settings > General Settings > Components, on the Output Commands tab.

M18000-0.XX – Control outputs – Incorrect signal address

What this means: the machine’s output command, configured as a Smart Accessory signal, has a signal number outside the range 1–20. This check applies only to Smart Accessory commands, provided the Smart Accessory is connected; digital commands do not trigger the alarm. In the code, XX is the output command number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • Invalid Smart accessory signal (Reset the commands).

How to resolve:

  1. Check command XX in Machine settings > General settings > Components, Output commands tab.
  2. Correct the signal number (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Reset the controls

How to recognise it: the alarm appears on a machine command associated with a signal from the Smart accessory.

Check:

  1. Check the command in Machine Settings > General Settings > Components, under the Input Commands tab, or in Machine Settings > General Settings > Components, under the Output Commands tab.
  2. Check that the signal number is between 1 and 20.

Remedy: correct the signal number (CEMAS technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Pump

Alarms for the machine’s pumps (up to four), triggered by vacuums, clamps and valves: electrical protection, pressure, level, filter and oil temperature. XX is the pump number. These are configured under Machine Settings > General Settings > Components, on the Pumps tab.

M19000-0.XX - Pump - Breaker triggered

What this means: the pump’s (thermal) protection switch is open. In the code, XX is the pump number (from 01 to 04).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked. The pump stops: vacuum lines, clamps and valves that use it have no pressure.

Probable causes:

  • motor overload or fault (Circuit breaker (thermal) tripped);
  • circuit breaker setting too low.

How to resolve:

  1. Reset the pump circuit breaker and check that it does not trip again (maintenance technician).
  2. If it trips again, check the motor and pump circuit (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before opening the electric panel, secure the machine in accordance with the user manual. Work to be carried out by qualified personnel only.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.

Circuit breaker (thermal) has tripped

How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.

Check:

  1. Locate the component’s circuit breaker on the wiring diagram and check its position.
  2. Check that the thermal setting corresponds to the diagram.
  3. Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.

Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M19001-0.XX – Pump – Maximum pressure

What this means: pump pressure exceeds the alarm threshold. In current versions of the machine software, the alert is programmed but is not triggered. In the code, XX is the pump number (from 01 to 04).

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out. Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.

M19002-0.XX - Pump - Analogue pressure alarm

1.23.12

What this means: the signal from the pump’s analogue pressure sensor is outside the valid range: the value is unreliable. In the code, XX is the pump number (from 01 to 04).

Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle. It is stored in memory. The pump continues to operate.

Probable causes:

  • sensor disconnected, cable broken or sensor faulty.

How to resolve:

  1. Check the pressure sensor connector and cable (maintenance technician).
  2. If the wiring is intact, replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset on the Alarm Monitor.

Safety:

Warning Before working on the hydraulic circuit, secure the machine in accordance with the user manual and release the pressure. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.

M19003-0.XX - Pump - Pressure-reach timeout

1.23.12

What this means: the hydraulic control unit has not reached the target pressure (with a tolerance of ±10 bar) within the specified time (5 s as standard). The target pressure and time are part of the pump configuration (Machine settings > General settings > Components, Pumps tab), set by CEMAS. This applies only to hydraulic pumps. In the code, XX is the pump number (from 01 to 04).

Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle. It remains stored. The pump continues to operate.

Probable causes:

  • low oil level or leaks in the circuit;
  • worn pump or misadjusted control valve;
  • faulty pressure sensor.

How to resolve:

  1. Check the oil level and ensure there are no leaks (maintenance technician).
  2. Check the pressure on the control unit’s pressure gauge (maintenance technician).
  3. If the pressure is correct, check the pressure sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on the hydraulic circuit, secure the machine in accordance with the user manual and release the pressure. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.

M19004-0.XX - Pump - Low oil level

1.23.12

What this means: the pump reservoir level sensor is indicating insufficient oil. In the code, XX is the pump number (from 01 to 04).

Effect: Alarm (red line): warning only: does not stop the machine or interrupt the automatic cycle. It remains stored in memory. The pump continues to operate. Continuing to operate with low oil levels may damage the pump.

Probable causes:

  • oil consumption or leaks;
  • faulty level sensor.

How to resolve:

  1. Check the level on the tank gauge.
  2. Top up with the oil specified in the user manual (maintenance technician).
  3. Check for any leaks in the circuit (maintenance technician).

Reset: once the cause has been rectified, press Reset on the Alarm Monitor.

Safety:

Warning Before working on the hydraulic circuit, secure the machine in accordance with the user manual and release the pressure. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.

M19005-0.XX - Pump - Clogged oil filter

What this means: the oil filter sensor on the pump is signaling that the filter is blocked. In the code, XX is the pump number (from 01 to 04).

Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle. The fault is stored in memory. The pump continues to operate.

Probable causes:

  • dirty filter or filter at the end of its service life;
  • faulty filter sensor.

How to resolve:

  1. Check the filter blockage indicator.
  2. Replace the cartridge in accordance with the user manual (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on the hydraulic circuit, secure the machine in accordance with the user manual and release the pressure. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.

M19006-0.XX - Pump - Maximum temperature

What this means: the oil thermostat on the pump indicates that the maximum temperature has been reached. In the code, XX is the pump number (from 01 to 04).

Effect: Alarm (red line): warning only: does not stop the machine or interrupt the automatic cycle. It remains stored in memory. The pump continues to operate. Oil that is too hot reduces the performance and service life of the circuit.

Probable causes:

  • oil cooler or fan is dirty or not working;
  • high ambient temperature or very heavy workload;
  • low oil level.

How to resolve:

  1. Check the oil level and the operation of the control unit’s cooling system (maintenance technician).
  2. Clean the heat exchanger (by a maintenance technician).
  3. Wait for the oil to cool down before resuming operation.

Recovery: once the cause has been rectified, press Reset on the Alarm Monitor.

Safety:

Warning Before carrying out any work on the hydraulic circuit, secure the machine in accordance with the user manual and relieve the pressure. Work to be carried out by a maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.

Gate

Alarms for the front and rear gates, which close off the work area during the cycle: movement times, sensors, controls and, for motorised gates, the axis and drive. Gate alarms stop the gate but do not switch the machine to manual mode.

The gates are configured in Machine Settings > General Settings > Components, under the Gates tab, and are operated manually via Machine Diagnostics > Manual Movements, under the Machine > Gates tab; the status of the motors can be viewed in Machine Diagnostics > Motor Status, under the Gates tab.

Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).

M20000-0.XX - Gate - Closing timeout

What this means: the gate has not reached the closed position within the closing time-out (default 10 s, under Machine settings > General settings > Components, Gates tab); for speed-controlled gates, the travel time is added to this. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). It does not switch the machine to manual mode: the automatic cycle remains on hold until the gate reaches the required position.

Probable causes:

  • no power or motor in alarm (item Check drive);
  • movement obstructed or dirty guides (sections Check cleanliness and Movement not completed);
  • closed position sensor out of calibration or faulty (section Sensors not working);
  • time-out too short (section Insufficient time).

How to resolve:

  1. Operate the gate manually via Machine diagnostics > Manual movements, Machine tab > Gates, and observe the movement.
  2. If it does not move, check the air supply (pneumatic) or the axis alarms (motorised).
  3. If it does not reach the end of its travel, remove any obstructions and clean the guides; if it does reach the end, check the sensor LED (maintenance technician).
  4. If the movement is smooth but slow, increase the time-out (CEMAS technician).

Reset: clear the fault by selecting Reset in the Alarm Monitor or by pressing the cycle start button, once the cause has been rectified.

Safety:

Warning The gate may move suddenly and cause crushing: before working on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).

Check the drive

How to identify the problem: the gate does not move or moves jerkily when activated.

Check:

  1. Pneumatic gate: check that air is reaching the cylinder and that the hoses are connected, intact and not kinked.
  2. Motorised gate: check under Machine status > Alarm monitor and under Machine diagnostics > Motor status, Gates tab, that the motor and drive have no alarms.

Remedy: the maintenance technician must restore the pneumatic supply or resolve any drive alarms.

Warning The gate may move suddenly and cause crushing: before working on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).
Not enough time

How to recognise this: the gate completes its movement smoothly, but shortly after the time-out has expired.

Check:

  1. Time the movement by initiating it from Machine Diagnostics > Manual Movements, Machine tab > Gates.
  2. Compare this with the opening or closing Time-out in Machine Settings > General Settings > Components, Gates tab.

Remedy: the CEMAS technician increases the time-out by an appropriate margin.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check that it is clean

How to recognise it: the gate slides with difficulty, slows down at certain points or is noisy.

Check:

  1. Check that the guides, runners and bearings are clean and lubricated (by a maintenance technician).
  2. Move the gate by hand and check that it runs smoothly.

Remedy: the maintenance technician should clean and lubricate the guides: CEMAS Elettra recommends NLGI 2 grease or Arexons GC300, always using the same type, as specified in the component catalogues.

Warning The gate may move suddenly and cause crushing: before carrying out any work on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).
Move not completed

How to identify the problem: the gate stops before reaching the end of its travel or reaches the end but the sensor does not light up.

Check:

  1. Check that nothing is obstructing the gate’s movement.
  2. Check the limit switch LED and ensure its input is correct in Machine Settings > General Settings > Components, under the Gates tab (maintenance technician).

Remedy: the maintenance technician removes the obstruction or adjusts the sensor; the CEMAS technician corrects any incorrect inputs.

Warning The gate may move suddenly and cause crushing: before carrying out any work on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20100-0.XX – Gate – External alarm

What this means: the warning (external gate alarm) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the alert appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: this may indicate a machine software version different from the one documented.

Availability: Machine option: only with Siemens or HDT motorised gates (Type).

M20101-0.XX – Gate – Security alarm

What this means: this warning (gate drive protection alarm) is provided for in the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the alarm appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: this may indicate a machine software version different from the one documented.

Availability: Machine option: only with Siemens or HDT motorised gates (Type).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20001-0.XX - Gate - Opening timeout

What this means: the gate has not reached the open position within the opening time-out (default 10 s, under Machine settings > General settings > Components, Gates tab); for speed-controlled gates, the travel time is added to this. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (command withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold until the gate reaches the required position.

Probable causes:

  • no power or motor in alarm (item Check drive);
  • movement obstructed or dirty guides (sections Check cleanliness and Movement not completed);
  • open position sensor out of calibration or faulty (section Sensors not working);
  • time-out too short (section Insufficient time).

How to resolve:

  1. Operate the gate manually via Machine diagnostics > Manual movements, Machine tab > Gates, and observe the movement.
  2. If it does not move, check the air supply (pneumatic) or the axis alarms (motorised).
  3. If it does not reach the end of its travel, remove any obstructions and clean the guides; if it does reach the end, check the sensor LED (maintenance technician).
  4. If the movement is smooth but slow, increase the time-out (CEMAS technician).

Reset: clear the fault by selecting Reset in the Alarm Monitor or by pressing the cycle start button, once the cause has been rectified.

Safety:

Warning The gate may move suddenly and cause crushing: before working on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).

Check the drive

How to identify the problem: the gate does not move or moves jerkily when activated.

Check:

  1. Pneumatic gate: check that air is reaching the cylinder and that the hoses are connected, intact and not kinked.
  2. Motorised gate: check under Machine status > Alarm monitor and under Machine diagnostics > Motor status, Gates tab, that the motor and drive have no alarms.

Remedy: the maintenance technician must restore the pneumatic supply or resolve any drive alarms.

Warning The gate may move suddenly and cause crushing: before working on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).
Not enough time

How to recognise this: the gate completes its movement smoothly, but shortly after the time-out has expired.

Check:

  1. Time the movement by initiating it from Machine Diagnostics > Manual Movements, Machine tab > Gates.
  2. Compare this with the opening or closing Time-out in Machine Settings > General Settings > Components, Gates tab.

Remedy: the CEMAS technician increases the time-out by an appropriate margin.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check that it is clean

How to recognise it: the gate slides with difficulty, slows down at certain points or is noisy.

Check:

  1. Check that the guides, runners and bearings are clean and lubricated (by a maintenance technician).
  2. Move the gate by hand and check that it runs smoothly.

Remedy: the maintenance technician should clean and lubricate the guides: CEMAS Elettra recommends NLGI 2 grease or Arexons GC300, always using the same type, as specified in the component catalogues.

Warning The gate may move suddenly and cause crushing: before carrying out any work on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).
Move not completed

How to identify the problem: the gate stops before reaching the end of its travel or reaches the end but the sensor does not light up.

Check:

  1. Check that nothing is obstructing the gate’s movement.
  2. Check the limit switch LED and ensure its input is correct in Machine Settings > General Settings > Components, under the Gates tab (maintenance technician).

Remedy: the maintenance technician removes the obstruction or adjusts the sensor; the CEMAS technician corrects any incorrect inputs.

Warning The gate may move suddenly and cause crushing: before carrying out any work on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20102-0.XX - Gate - Drive not configured

What this means: The field network diagnostics (PROFINET) signal that the gate drive is not configured or has a configuration different from that expected. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (command withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.

Probable causes:

  • the drive has been replaced with one that is not identical or has not yet been configured (see Configure drive);
  • drive configuration lost.

How to resolve:

  1. Check whether the drive has been replaced recently: the replacement must be identical to the original.
  2. Configure the drive (CEMAS technician).

Reset: this clears automatically once the drive is recognised.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Availability: Machine option: only with Siemens or HDT motorised gates (Type).

Configure the drive

How to identify this: the axis drive is not configured, for example following a replacement.

Check:

  1. Check whether the drive has been replaced recently.
  2. Check that the model fitted is the one specified in the wiring diagram.

Remedy: the drive must be configured by CEMAS Elettra personnel: contact support (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20002-0.XX - Gate - Closed position not released

What this means: when the opening command is issued, once the time-out has expired, the closed-position sensor is still active: either the gate has not started moving or the sensor remains active. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stationary (command withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.

Probable causes:

  • gate mechanically jammed (see Gate jammed);
  • command not executed: no air supply or motor in alarm mode (see Check operation);
  • closed position sensor constantly active (see Sensors not working).

How to resolve:

  1. Operate the gate manually via Machine diagnostics > Manual movements, Machine tab > Gates, and observe the movement.
  2. If the gate does not move, check the air supply or axis alarms and remove any obstructions.
  3. If the gate moves, check that the closed position sensor LED goes out (maintenance technician).

Reset: clear the fault using Reset in the Alarm Monitor or the cycle start button, once the cause has been rectified.

Safety:

Warning The gate may move suddenly and cause crushing: before carrying out any work on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).

Check the drive

How to identify the problem: the gate does not move or moves jerkily when activated.

Check:

  1. Pneumatic gate: check that air is reaching the cylinder and that the hoses are connected, intact and not kinked.
  2. Motorised gate: check under Machine status > Alarm monitor and under Machine diagnostics > Motor status, Gates tab, that the motor and drive have no alarms.

Remedy: the maintenance technician must restore the pneumatic supply or resolve any drive alarms.

Warning The gate may move suddenly and cause crushing: before working on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).
Gate locked

How to identify the problem: when the command is given, the gate does not move and the position sensor remains lit.

Check:

  1. Check that there are no mechanical obstructions blocking the gate.
  2. Operate the gate manually via Machine Diagnostics > Manual Movements, under the Machine tab > Gates.

Remedy: the maintenance technician removes the obstruction; if the gate remains stationary for no apparent reason, check the pneumatic system or the drive.

Warning The gate may move suddenly and cause crushing: before working on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20003-0.XX - Gate - Open position not released

What this means: when the closing command is issued, once the time-out has expired, the open-position sensor is still active: either the gate has not started moving or the sensor remains active. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (command withdrawn, motor disabled). Does not switch the system to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.

Probable causes:

  • gate mechanically jammed (see Gate jammed);
  • command not executed: no air supply or motor in alarm mode (see Check operation);
  • open position sensor always active (see Sensors not working).

How to resolve:

  1. Operate the gate manually via Machine diagnostics > Manual movements, Machine tab > Gates, and observe the movement.
  2. If the gate does not move, check the air supply or axis alarms and remove any obstructions.
  3. If the gate moves, check that the open position sensor LED goes out (maintenance technician).

Reset: clear the fault using Reset in the Alarm Monitor or the cycle start button once the cause has been rectified.

Safety:

Warning The gate may move suddenly and cause crushing: before carrying out any work on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.

Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).

Check the drive

How to identify the problem: the gate does not move or moves jerkily when activated.

Check:

  1. Pneumatic gate: check that air is reaching the cylinder and that the hoses are connected, intact and not kinked.
  2. Motorised gate: check under Machine status > Alarm monitor and under Machine diagnostics > Motor status, Gates tab, that the motor and drive have no alarms.

Remedy: the maintenance technician must restore the pneumatic supply or resolve any drive alarms.

Warning The gate may move suddenly and cause crushing: before working on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).
Gate locked

How to identify the problem: when the command is given, the gate does not move and the position sensor remains lit.

Check:

  1. Check that there are no mechanical obstructions blocking the gate.
  2. Operate the gate manually via Machine Diagnostics > Manual Movements, under the Machine tab > Gates.

Remedy: the maintenance technician removes the obstruction; if the gate remains stationary for no apparent reason, check the pneumatic system or the drive.

Warning The gate may move suddenly and cause crushing: before working on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20103-0.XX – Gate – Drive unit inaccessible

What this means: The PLC is unable to communicate with the gate drive on the field network (PROFINET). In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (command withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains waiting for the gate to reach the required position.

Probable causes:

  • drive switched off or without logic power supply (see Drive power-up);
  • network cable disconnected or damaged (see Check communication).

How to resolve:

  1. If a limit switch alarm is also active, resolve that first.
  2. Check that the drive’s display or status LEDs are lit (electrical maintenance technician).
  3. Check the network cable: the port LEDs must be lit or flashing (electrical maintenance technician).

Reset: clears automatically when communication is restored.

Safety:

Warning Electric panel: authorised electrical maintenance technician only, with the machine in a safe state as per the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: only with Siemens or HDT motorised gates (Type).

Powering on the drive

How to identify the problem: the drive is not responding to the PLC: the display or status LEDs are off.

Check:

  1. Check that the drive is powered (display or LEDs lit).
  2. Check the drive’s power switches in the electric panel.

Remedy: restore the power supply; if the drive remains off or in error mode, have it checked (by an electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Check the message

How to identify the problem: the drive is switched on but the PLC is not communicating with it.

Check:

  1. Check the drive’s Profinet network cable and the port LED.
  2. Check in Machine Diagnostics > Motor Status that the axis values are updating.

Remedy: Reconnect or replace the network cable (maintenance technician).

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation is reserved for qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20004-0.XX - Gate - External alarm

What this means: the warning (external gate alarm) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the alert appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: this may indicate a machine software version different from the one documented.

Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).

M20104-0.XX - Gate - Drive hardware fault

What this means: the field network diagnostics signal a hardware fault in the gate drive. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.

Probable causes:

  • fault in the drive’s electronics;
  • unstable logic power supply.

How to resolve:

  1. Read the Drive fault code in the drive diagnostics pop-up (i icon on the motor card) under Machine diagnostics > Motor status, Gates tab (Axis error code entry).
  2. Switch the machine off and on again in accordance with the user manual (maintenance technician).
  3. If the fault reoccurs, report the code to the service department.

Reset: the fault clears automatically once the fault has been rectified.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: only with Siemens or HDT motorised gates (Type).

Axis error code

How to identify it: the axis drive has encountered an error.

Check:

  1. In Machine Diagnostics > Motor Status, open the axis card and tap the i icon.
  2. Read and note down the error code (Drive fault code, Alarms word tab) displayed in the diagnostics pop-up.

Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the error recurs, report the code to CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tool, ensure the machine is safely shut down in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20105-0.XX – Gate – Drive alarm

What this means: there is a fault with the gate’s drive system (motor, encoder, power supply or movement). This is not signalled when the safety guards are open or the barrier is in alarm mode. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.

Probable causes:

  • overload or obstructed movement;
  • motor or drive overheating;
  • damaged encoder or motor cables.

How to resolve:

  1. Read the Drive fault code in the drive diagnostics pop-up (i icon on the motor card) under Machine diagnostics > Motor status, Logs tab (Axis error code entry).
  2. Check that nothing is obstructing movement.
  3. Press Reset; if the error reoccurs, report the code to support.

Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on moving parts, secure the machine in accordance with the user manual; only carry out manual movements when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: only with Siemens or HDT motorised gates (Type).

Axis error code

How to identify it: the axis drive has encountered an error.

Check:

  1. In Machine Diagnostics > Motor Status, open the axis card and tap the i icon.
  2. Read and note down the error code (Drive fault code, Alarms word tab) displayed in the diagnostics pop-up.

Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the error recurs, report the code to CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tool, ensure the machine is safely shut down in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20005-0.XX - Gate - Both position sensors

What this means: the sensors for the gate’s open and closed positions are active at the same time. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control signal withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.

Probable causes:

  • faulty sensor or sensor constantly active (see Faulty sensors);
  • sensors positioned so that both detect the gate (see Sensor positioning);
  • sensor inputs set incorrectly.

How to resolve:

  1. Observe the LEDs on the two sensors whilst moving the gate by hand: each one should light up only when in its correct position (maintenance technician).
  2. Reposition or replace the sensor that remains lit.
  3. Check the inputs under Machine Settings > General Settings > Components, Gates tab (CEMAS technician).

Reset: clear by selecting Reset in the Alarm Monitor or by pressing the cycle start button, once the cause has been rectified.

Safety:

Warning The gate may move suddenly and cause crushing: before carrying out any work on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.

Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).

Sensor positioning

How to identify this: the ‘open’ and ‘closed’ sensors are both lit.

Check:

  1. Move the gate and observe the LEDs: one should light up only when the gate is open, the other only when the gate is closed (maintenance technician).

Remedy: the maintenance technician repositions the sensor that detects both positions or replaces it if faulty.

Warning The gate may move suddenly and cause crushing: before carrying out any work on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20106-0.XX – Gate – Technical equipment alarm

What this means: the gate PLC’s motion control system has signalled an error, such as a tracking error or a software limit being exceeded. This error is not signalled when the safety guards are open or the barrier is in alarm mode. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.

Probable causes:

  • movement braked or obstructed;
  • actuator faulty or not ready.

How to resolve:

  1. Check the active bits in the Alarms word card in the drive diagnostics pop-up (the i icon on the motor card) under Machine diagnostics > Motor status, Gates tab (Axis status code entry).
  2. Resolve any other drive alarms.
  3. Press Reset and attempt a manual movement via Machine Diagnostics > Manual Movements, Machine tab > Clear.

Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on moving parts, secure the machine in accordance with the user manual; only perform manual movements when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: only with Siemens or HDT motorised gates (Type).

Axis status coding

How to recognise it: the axis is stationary in alarm mode and its drive signals an abnormal status.

Check:

  1. In Machine Diagnostics > Motor Status, open the axis card and tap the i icon: the diagnostics pop-up displays the drive’s current statuses, errors and warnings.
  2. Make a note of the statuses and errors displayed.

Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the fault persists, report the noted data to CEMAS Elettra support.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20006-0.XX - Gate - Both commands

What this means: the gate opening and closing commands are active at the same time: the output configuration is inconsistent. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (command withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold until the gate is in the required position.

Probable causes:

  • Control outputs set incorrectly, for example, the same output used for both commands (see Resetting the commands).

How to resolve:

  1. Check the gate outputs under Machine settings > General settings > Components, Gates tab (CEMAS technician).
  2. Operate the gate manually via Machine diagnostics > Manual movements, Machine tab > Gates, and observe the movement.

Reset: press Reset in the Alarm Monitor or use the cycle start button once the cause has been rectified.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).

Reset the controls

How to recognise it: an alarm is triggered by both commands being active, even if the gate is not moving.

Check:

  1. Check in Machine Settings > General Settings > Components, under the Gates tab, that opening and closing use different and correct outputs (CEMAS technician).

Remedy: the CEMAS technician corrects the outputs and tests the gate manually.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20107-0.XX - Gate - Positive overtravel alarm

What this means: the gate’s positive over-travel limit switch is active (if enabled): the shaft is beyond its working travel. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.

Probable causes:

  • movement beyond the travel limit in manual mode or with movement constraints deactivated;
  • lost or incorrect reference;
  • limit switch faulty, out of alignment or disconnected (see Sensors not working).

How to resolve:

  1. Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab > Gates (see Release Overtravel).
  2. Whilst the axis is moving, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
  3. If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).

Safety:

Warning Before working on moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: only with Siemens or HDT motorised gates (Type).

Release the overrun

How to recognise this: the axis has reached the over-travel limit, beyond its normal travel; continuing would damage the machine.

Check:

  1. In Machine Diagnostics > Manual Movements, on the Machine tab, check the direction in which the axis has reached the overtravel limit.
  2. Check that the overtravel sensor is not faulty or misaligned.

Remedy: move the axis by hand in the opposite direction until the sensor is released, then press Reset; if the axis does not move, contact CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20007-0.XX – Gate – Unreferenced axis

What this means: the gate motor is powered but does not have a reference position: the position reading is unreliable. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.

Probable causes:

  • motor, encoder or drive replaced (see Perform reset);
  • reference lost following an encoder fault.

How to resolve:

  1. Check the Referenced indicator in Machine Diagnostics > Motor Status, Gates tab.
  2. With the machine in manual mode, reference the gate using Home position in Machine settings > General settings > Components, Gates tab (CEMAS technician).

Reset: this clears automatically after referencing.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra S.r.l. personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: only with Siemens or HDT motorised gates (Type).

Perform a reset

How to identify the issue: under Machine Diagnostics > Motor Status, on the Gates tab, the gate’s Referenced indicator is grey.

Check:

  1. Check whether the gate’s motor, encoder or drive has been replaced.

Remedy: the CEMAS technician must re-reference the gate to the Home position in Machine Settings > General Settings > Components, under the Gates tab, whilst the machine is in manual mode.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20008-0.XX - Gate - Axis alarm

What this means: the gate axis is in alarm mode: on Siemens and HDT gates, an alarm is displayed in the axis details; on high-speed gates, the drive is in error mode. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the system to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.

Probable causes:

  • fault in the gate actuator or motor (see Axis status coding);
  • movement obstructed.

How to resolve:

  1. Check the detailed gate alarms in Machine status > Alarm monitor and follow the instructions.
  2. Check the drive status in the drive diagnostics pop-up (the i icon on the motor card) under Machine diagnostics > Motor status, Gates tab.
  3. Check that nothing is obstructing the gate.

Reset: clear the alarm by selecting Reset in the Alarm Monitor or by pressing the cycle start button once the cause has been rectified.

Safety:

Warning The gate may move suddenly and cause crushing: before working on the gate, guides or sensors, secure the machine in accordance with the user manual (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.

Availability: Machine option: available only with motorised gates (Type: Siemens, HDT or Velocità).

Axis status coding

How to recognise it: gate shaft alarm with no apparent cause.

Check:

  1. Open the drive diagnostics pop-up (the i icon on the motor card) in Machine Diagnostics > Motor Status, under the Gates tab.
  2. Read the active bits and the fault and warning codes.

Remedy: resolve the indicated cause; if it is unclear, report the codes to CEMAS Elettra support.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20108-0.XX - Gate - Negative overtravel alarm

What this means: the gate’s negative over-travel limit switch is active (if enabled): the shaft is beyond its operating travel. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.

Probable causes:

  • movement beyond the travel limit in manual mode or with movement constraints deactivated;
  • lost or incorrect reference;
  • limit switch faulty, out of alignment or disconnected (see Sensors not working).

How to resolve:

  1. Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab > Gates (see Release Overtravel).
  2. Whilst the axis is moving, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
  3. If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).

Safety:

Warning Before working on moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: only with Siemens or HDT motorised gates (Type).

Release the overrun

How to recognise this: the axis has reached the over-travel limit, beyond its normal travel; continuing would damage the machine.

Check:

  1. In Machine Diagnostics > Manual Movements, on the Machine tab, check the direction in which the axis has reached the overtravel limit.
  2. Check that the overtravel sensor is not faulty or misaligned.

Remedy: move the axis by hand in the opposite direction until the sensor is released, then press Reset; if the axis does not move, contact CEMAS Elettra S.r.l. support.

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M20009-0.XX – Gate – Logic switch

What this means: the gate drive’s automatic switch (thermal logic) is open: the enabled input is low. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the system to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the drive power supply (see Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not reset;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the gate logic circuit breaker (electrical maintenance technician).
  2. If it trips again, do not keep trying: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and the wiring.

Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using the Reset button.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a circuit breaker that has tripped.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: available only with motorised gates (Type: Siemens, HDT or Velocità).

M20010-0.XX - Gate - Power switch

What this means: the gate drive’s circuit breaker (thermal overload) has tripped: the enabled input is low. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the system to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the motor or its cable (see Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not reset;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the gate’s main circuit breaker (maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and the wiring.

Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using the Reset button.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a circuit breaker that has tripped.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: available only with motorised gates (Type: Siemens, HDT or Velocità).

M20011-0.XX - Gate - Breaker triggered

What this means: the circuit breaker supplying power to the gate motor brake has tripped: the enabled input is low. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.

Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the system to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the brake or its cable (see Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not reset;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the gate brake circuit breaker (electrical maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the fault indication persists, check the auxiliary contact and the wiring.

Reset: the fault clears automatically when the circuit breaker is closed again; other drive alarms are cleared using the Reset button.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a circuit breaker that has tripped.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: available only with motorised gates (Type: Siemens, HDT or Velocità).

Transducer system

Alarms from the transducer system, the linear position sensors that measure the height of the table (and the head, where fitted) during welding: status of the left and right units and misalignment between the transducers on the same axis.

The positions and misalignment can be viewed under Machine Diagnostics > Transducers; the limits are set under Machine Settings > General Settings > Components, on the Transducers tab.

Availability: Machine option: appears if position transducers are configured; this option is configured by CEMAS.

M21000-0.XX – Transducer system – Left-hand unit alarm

What this means: At least one of the transducers on the left-hand side (top or bottom) is in alarm mode: this is the summary for the left-hand unit.

Effect: The alert is not displayed in the Alarm Monitor: the height is invalid, so an ongoing welding process is interrupted (rejected part) and the machine switches to Manual mode. The line visible in the Alarm Monitor is that of the individual transducer, showing its number.

Probable causes:

  • transducer not powered;
  • network or power cable disconnected or damaged.

How to resolve:

  1. On the Machine Status > Alarm Monitor page, check the alarm for transducer 01 (top left) or 02 (bottom left) and follow the procedure.

Reset: once the cause has been rectified, select Reset in the Alarm Monitor.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Transducer connection

How to identify the problem: the transducer is not communicating: under Machine Diagnostics > Transducers, the reading is missing or is not updating.

Check:

  1. Check the transducer’s power cable and Profinet network cable.
  2. Check the transducer’s LEDs.

Remedy: Reconnect or replace any damaged cables (maintenance technician).

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.
Check the magnet

How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.

Check:

  1. Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
  2. Check that the transducer magnet and rod are clean and undamaged.

Remedy: clean, reposition or replace the magnet (by a maintenance technician).

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M21001-0.XX - Transducer system - Right-hand unit alarm

What this means: At least one of the transducers on the right-hand side (top or bottom) is in alarm mode: this is the summary for the right-hand unit.

Effect: The alert is not displayed in the Alarm Monitor: the height is invalid, so ongoing welding is interrupted (rejected part) and the machine switches to Manual mode. The line visible in the Alarm Monitor is that of the individual transducer, showing its number.

Probable causes:

  • transducer not powered;
  • network or power cable disconnected or damaged.

How to resolve:

  1. On the Machine Status > Alarm Monitor page, check the alarm for transducer 03 (top right) or 04 (bottom right) and follow the procedure.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Transducer connection

How to identify the problem: the transducer is not communicating: under Machine Diagnostics > Transducers, the reading is missing or is not updating.

Check:

  1. Check the transducer’s power cable and Profinet network cable.
  2. Check the transducer’s LEDs.

Remedy: Reconnect or replace any damaged cables (maintenance technician).

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.
Check the magnet

How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.

Check:

  1. Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
  2. Check that the transducer magnet and rod are clean and undamaged.

Remedy: clean, reposition or replace the magnet (by a maintenance technician).

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M21002-0.XX – Transducer system – Maximum head misalignment error

What this means: With transducers on both sides, the difference between the readings of the upper (head) transducers exceeds the Maximum head misalignment error (typically 0.5 millimetres, mm) in Machine settings > General settings > Components, under the Transducers tab. Check is always active; remains stored.

Effect: alert not displayed in the Alarm Monitor: the height is invalid, so a welding operation in progress is interrupted (rejected part) and the machine switches to Manual mode. There is no dedicated line in the Alarm Monitor.

Probable causes:

  • magnet or transducer loose or displaced;
  • head not parallel.

How to resolve:

  1. In Machine Diagnostics > Transducers, compare the high measurements with the Head misalignment error card.
  2. Check that the head’s magnets and transducers are securely fastened (maintenance technician).
  3. If the discrepancy persists, have the head’s parallelism checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Check the magnet

How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.

Check:

  1. Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
  2. Check that the transducer magnet and rod are clean and undamaged.

Remedy: clean, reposition or replace the magnet (by a maintenance technician).

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check the installation

How to identify the problem: the reading for a transducer under Machine Diagnostics > Transducers is different from the expected value or from that of the other side, or the transducer is signaling a fault.

Check:

  1. With the machine in a safe state, check that the transducer is securely fastened and aligned with the axis.
  2. Check that the magnets are secured, clean and at the correct distance from the transducer.
  3. Once the machine is back in service, move the axis and check in Machine Diagnostics > Transducers that the position changes smoothly.

Remedy: secure or reposition the transducer and magnets (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M21003-0.XX – Transducer system – Maximum misalignment error: Table

What this means: With transducers on both sides, the difference between the readings from the lower transducers (table) exceeds the Maximum table misalignment error (typically 0.5 millimetres, mm) in Machine settings > General settings > Components, under the Transducers tab. Check always active; remains stored.

Effect: Alarm (red line): the height is invalid, so a welding operation in progress is interrupted (scrap part) and the machine switches to Manual mode.

Possible causes:

  • magnet or transducer loose or displaced;
  • table not parallel.

How to resolve:

  1. In Machine Diagnostics > Transducers, compare the lower dimensions with the Table misalignment error card, whilst moving the table by hand.
  2. Check that the magnets and transducers on the table are securely fixed (maintenance technician).
  3. If the discrepancy persists, have the table checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Check the magnet

How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.

Check:

  1. Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
  2. Check that the transducer magnet and rod are clean and undamaged.

Remedy: clean, reposition or replace the magnet (by a maintenance technician).

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check the installation

How to identify the problem: the reading for a transducer under Machine Diagnostics > Transducers is different from the expected value or from that of the other side, or the transducer is signaling a fault.

Check:

  1. With the machine in a safe state, check that the transducer is securely fastened and aligned with the axis.
  2. Check that the magnets are secured, clean and at the correct distance from the transducer.
  3. Once the machine is back in service, move the axis and check in Machine Diagnostics > Transducers that the position changes smoothly.

Remedy: secure or reposition the transducer and magnets (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Transducer unit

Alarms for the left and right transducer units: these summarise the status of the upper and lower transducers on each side.

Availability: Machine option: appears if the position transducers are configured; this option is configured by CEMAS.

M22000-0.XX – Transducer unit – Upper transducer alarm

What this means: The high transducer for the specified unit is in alarm; check this when the corresponding side also shows a high reading. In the code, XX indicates the unit: 01 left, 02 right.

Effect: alert not displayed in the Alarm Monitor: the level is invalid, so an ongoing welding process is interrupted (rejected part) and the machine switches to Manual mode. The line visible in the Alarm Monitor is that of the individual transducer, showing its number.

Probable causes:

  • transducer not powered;
  • network or power cable disconnected or damaged.

How to resolve:

  1. On the Machine Status > Alarm Monitor page, check the alarm for transducer 01 (top left) or 03 (top right) and follow the procedure.

Reset: the alarm clears automatically once the transducer is no longer in alarm mode.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Transducer connection

How to identify the problem: the transducer is not communicating: under Machine Diagnostics > Transducers, the reading is missing or is not updating.

Check:

  1. Check the transducer’s power cable and Profinet network cable.
  2. Check the transducer’s LEDs.

Remedy: Reconnect or replace any damaged cables (maintenance technician).

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.
Check the magnet

How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.

Check:

  1. Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
  2. Check that the transducer magnet and rod are clean and undamaged.

Remedy: clean, reposition or replace the magnet (by a maintenance technician).

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M22001-0.XX - Transducer unit - Lower transducer alarm

What this means: The lower transducer in the specified unit is in alarm. In the code, XX indicates the unit: 01 left, 02 right.

Effect: the message is not displayed in the Alarm Monitor: the height is invalid, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode. The line visible in the Alarm Monitor is that of the individual transducer, showing its number.

Probable causes:

  • transducer not powered;
  • network or power cable disconnected or damaged.

How to resolve:

  1. On the Machine Status > Alarm Monitor page, check the alarm for transducer 02 (bottom left) or 04 (bottom right) and follow the procedure.

Reset: the alarm clears automatically once the transducer is no longer in alarm mode.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Transducer connection

How to identify the problem: the transducer is not communicating: under Machine Diagnostics > Transducers, the reading is missing or is not updating.

Check:

  1. Check the transducer’s power cable and Profinet network cable.
  2. Check the transducer’s LEDs.

Remedy: Reconnect or replace any damaged cables (maintenance technician).

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.
Check the magnet

How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.

Check:

  1. Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
  2. Check that the transducer magnet and rod are clean and undamaged.

Remedy: clean, reposition or replace the magnet (by a maintenance technician).

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Transducer

Alarms for individual position transducers: network communication, faults, full-scale and position reading. The element number identifies the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right. The values can be viewed under Machine Diagnostics > Transducers.

Availability: Machine option: appears if the position transducers are configured; this option is configured by CEMAS.

M23000-0.XX – Transducer – Not accessible

What this means: The PLC is unable to access the transducer via the network. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).

Effect: Alarm (red line): the height is invalid, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode.

Probable causes:

  • transducer not powered;
  • network or power cable disconnected or damaged;
  • faulty network switch.

How to resolve:

  1. Check in Machine Diagnostics > PLC, under the PLC Hardware tab, whether the transducer is showing an error.
  2. Check the power supply, network LED, cables and connectors of the transducer (maintenance technician).
  3. Press Reset.

Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Transducer connection

How to identify the problem: the transducer is not communicating: under Machine Diagnostics > Transducers, the reading is missing or is not updating.

Check:

  1. Check the transducer’s power cable and Profinet network cable.
  2. Check the transducer’s LEDs.

Remedy: Reconnect or replace any damaged cables (maintenance technician).

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.
Check the magnet

How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.

Check:

  1. Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
  2. Check that the transducer magnet and rod are clean and undamaged.

Remedy: clean, reposition or replace the magnet (by a maintenance technician).

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M23001-0.XX – Transducer – Hardware fault

What this means: The transducer is sending signals indicating a fault in its electronics. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (01 to 04).

Effect: Alarm (red line): the height is invalid, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode.

Probable causes:

  • faulty transducer;
  • damaged or incorrectly fitted transducer.

How to resolve:

  1. Check the fixing and integrity of the transducer and magnet (maintenance technician).
  2. Switch the machine off and on again, then press Reset.
  3. If the fault persists, replace the transducer (CEMAS technician).

Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Check the installation

How to identify the problem: the reading for a transducer under Machine Diagnostics > Transducers is different from the expected value or from that of the other side, or the transducer is signaling a fault.

Check:

  1. With the machine in a safe state, check that the transducer is securely fastened and aligned with the axis.
  2. Check that the magnets are secured, clean and at the correct distance from the transducer.
  3. Once the machine is back in service, move the axis and check in Machine Diagnostics > Transducers that the position changes smoothly.

Remedy: secure or reposition the transducer and magnets (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check the magnet

How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.

Check:

  1. Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
  2. Check that the transducer magnet and rod are clean and undamaged.

Remedy: clean, reposition or replace the magnet (by a maintenance technician).

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M23002-0.XX - Transducer - Mains fault

What this means: The transducer is signaling a network error: communication disruption or device not configured correctly. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).

Effect: Alarm (red line): the height is invalid, so any welding in progress is interrupted (scrap piece) and the machine switches to Manual mode.

Probable causes:

  • faulty network cable or switch;
  • transducer replaced but not configured.

How to resolve:

  1. Check the cable, connectors and LEDs on the switch port (maintenance technician).
  2. If the transducer has been replaced, have its network configuration checked (CEMAS technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M23003-0.XX - Transducer - Full scale reached

What this means: The transducer returns a value outside the measurement range, usually because it cannot detect the magnet. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).

Effect: Alarm (red line): the position is invalid, so any welding in progress is interrupted (scrap piece) and the machine switches to Manual mode.

Probable causes:

  • magnet missing, detached or too far away;
  • faulty wiring.

How to resolve:

  1. Check the transducer reading in Machine Diagnostics > Transducers: an out-of-range value confirms the alarm.
  2. Check the magnet (present, clean, at the correct distance) and the wiring (maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Check the magnet

How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.

Check:

  1. Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
  2. Check that the transducer magnet and rod are clean and undamaged.

Remedy: clean, reposition or replace the magnet (by a maintenance technician).

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check the assembly

How to identify this: the transducer reading under Machine Diagnostics > Transducers is out of range or missing.

Check:

  1. With the machine in a safe state, check the position and alignment of the magnet relative to the transducer.
  2. Check that the transducer’s electrical wiring is intact and that the connectors are securely fitted.

Remedy: reposition the magnet or replace the damaged cable (maintenance technician).

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M23004-0.XX – Transducer – Device in activation mode

What this means: The transducer has not completed its network activation. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).

Effect: Alarm (red line): the height is invalid, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode.

Probable causes:

  • transducer still starting up;
  • transducer replaced but not configured;
  • unstable power supply or mains supply.

How to resolve:

  1. Wait a few seconds and press Reset.
  2. If the problem recurs, check the power supply and network cable (maintenance technician).
  3. If the transducer has been replaced, have its configuration checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M23005-0.XX – Transducer – Second position illegible

What this means: The top transducer, configured to read two positions (two magnets on the same transducer), is not providing the second position. Checked only in this configuration; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).

Effect: Alarm (red line): the height is invalid, so a welding operation in progress is interrupted (scrap piece) and the machine switches to Manual mode.

Probable causes:

  • single-position transducer fitted instead of a dual-position one;
  • second magnet missing or out of range;
  • transducer not accessible on the network.

How to resolve:

  1. Check that the transducer is the specified two-position type (maintenance technician).
  2. Check the presence and secure fixation of the second magnet.
  3. Press Reset; if the fault recurs, have the configuration checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

Check the magnet

How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.

Check:

  1. Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
  2. Check that the transducer magnet and rod are clean and undamaged.

Remedy: clean, reposition or replace the magnet (by a maintenance technician).

Warning Before carrying out any work in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check the installation

How to identify the problem: the reading for a transducer under Machine Diagnostics > Transducers is different from the expected value or from that of the other side, or the transducer is signaling a fault.

Check:

  1. With the machine in a safe state, check that the transducer is securely fastened and aligned with the axis.
  2. Check that the magnets are secured, clean and at the correct distance from the transducer.
  3. Once the machine is back in service, move the axis and check in Machine Diagnostics > Transducers that the position changes smoothly.

Remedy: secure or reposition the transducer and magnets (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M23006-0.XX – Transducer – Fixed value

What this means: The transducer value (resolution 0.001 millimetres, mm) remains unchanged for 500 milliseconds (ms): the reading appears to be stuck. Also checked whilst the machine is stationary, with a position other than zero. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).

Effect: Alarm (red line): the height is invalid, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode.

Probable causes:

  • communication blocked;
  • magnet detached or not securely attached to the axis.

How to resolve:

  1. Move the axis by hand and check in Machine Diagnostics > Transducers that the position changes.
  2. If it does not change, check the magnet, transducer and power cable (maintenance technician).
  3. Press Reset; if the fault recurs, have the transducer checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.

SmartAccessory

Alarms from the Smart accessory, the external device with its own PLC connected to the welding machine (conveyor systems, traceability, robots). Details of the alarms can be found in the Smart accessory tab on the Machine status > Alarm monitor page and on the Machine diagnostics > Smart accessory page.

Availability: machine option: only available if the Smart accessory is present; option configured by CEMAS.

M24000-0.XX - SmartAccessory - Communication alarm

What this means: The Smart Accessory is no longer responding: the communication status signal has been static for 5 seconds.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Possible causes:

  • the Smart Accessory’s network or power cable is disconnected (Smart Accessory Connection);
  • the Smart Accessory is switched off or frozen.

How to resolve:

  1. Check that the Smart Accessory is switched on.
  2. Check the network cable and the communication LEDs.
  3. Open the Machine Diagnostics > Smart Accessory page: if a message stating that the device is unreachable appears, the connection has been lost.

Resolution: the message disappears automatically once the issue has been resolved.

Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.

Smart Accessory Connection

How to identify the issue: The Smart accessory is not communicating and the Machine Diagnostics > Smart accessory page does not load.

Check:

  1. Check that the Smart accessory is powered up and switched on.
  2. Check the network cable and the communication LEDs at both ends.

Remedy: Reconnect or replace the cable; restart the Smart accessory (maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M24001-0.XX - SmartAccessory - Offline

What this means: The Smart Accessory is disconnected from the welding machine’s PLC.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • Power cable disconnected or damaged (Smart Accessory connection);
  • Smart accessory switched off.

How to resolve:

  1. Check the power supply and ensure the Smart Accessory is switched on.
  2. Check the network cable and connectors (maintenance technician).

Resolution: the error clears automatically once the issue has been resolved.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.

Smart Accessory Connection

How to identify the issue: The Smart accessory is not communicating and the Machine Diagnostics > Smart accessory page does not load.

Check:

  1. Check that the Smart accessory is powered up and switched on.
  2. Check the network cable and the communication LEDs at both ends.

Remedy: Reconnect or replace the cable; restart the Smart accessory (maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M24002-0.XX - SmartAccessory - Unsupported version

What this means: the Smart Accessory software version is not supported by the welding machine: either the major version is different, or the minor version is older than the one required.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • Smart accessory programme not up to date (Update Smart Accessory version).

How to resolve:

  1. Note down the PLC Release in Machine Diagnostics > Support.
  2. Request an update for the Smart Accessory (CEMAS technician).

Resolution: the issue resolves itself once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.

Update Smart Accessory version

How to recognise it: the message Unsupported version appears immediately after connecting the Smart accessory.

Check:

  1. Make a note of the PLC release under Machine diagnostics > Support.
  2. Note down the version of the Smart accessory from the Machine Diagnostics > Smart accessory page, if available.

Remedy: request an update for the Smart accessory from CEMAS Elettra support (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M24003-0.XX - SmartAccessory - Machine version not supported

What this means: The Smart accessory reports that it does not support the welding machine’s software version.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • Welding machine software is not compatible (Update the welding machine PLC version).

How to resolve:

  1. Note down the PLC Release in Machine Diagnostics > Support.
  2. Request a software update (CEMAS technician).

Resolution: the alarm clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.

Update the PLC version of the welding machine

How to recognise it: the message ‘Machine version not supported’ appears immediately after connecting the Smart accessory.

Check:

  1. Note down the PLC release under Machine diagnostics > Support.

Remedy: the welding machine’s software must be updated by CEMAS Elettra personnel: contact support (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M24004-0.XX - SmartAccessory - Transport System Error

1.17.10

What this means: The Smart Accessory signals an alarm from the transport system (e.g. a workpiece conveyor) that it controls.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • Conveyor system fault.

How to resolve:

  1. Check the details in the Smart accessory tab on the Machine status > Alarm monitor page and on the Machine diagnostics > Smart accessory page.
  2. Resolve the fault on the specified device, in accordance with its documentation.
  3. Check that the alert disappears.

Reset: the alert disappears automatically once the condition no longer exists.

Safety:

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.

M24005-0.XX - SmartAccessory - Traceability error

1.17.10

What this means: The Smart Accessory signals an alarm from the traceability system (e.g. barcode readers or label printers).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • traceability system fault.

How to resolve:

  1. Check the details in the Smart accessory tab on the Machine status > Alarm monitor page and on the Machine diagnostics > Smart accessory page.
  2. Resolve the fault on the specified device, in accordance with its documentation.
  3. Check that the alert disappears.

Reset: the alert clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.

M24006-0.XX - SmartAccessory - Robot error

1.17.10

What this means: The Smart Accessory signals an alarm from the robot it controls.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • robot fault or shutdown.

How to resolve:

  1. Check the details in the Smart accessory tab on the Machine status > Alarm monitor page and on the Machine diagnostics > Smart accessory page.
  2. Resolve the fault on the specified device, in accordance with its documentation.
  3. Check that the alert disappears.

Reset: the alert disappears automatically once the condition no longer exists.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.

M24007-0.XX - SmartAccessory - General

1.17.10

What this means: The Smart Accessory is triggering a general alarm, not related to transport, traceability or robots.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.

Probable causes:

  • Internal fault in the Smart accessory.

How to resolve:

  1. Check the details in the Smart accessory tab on the Machine status > Alarm monitor page and on the Machine diagnostics > Smart accessory page.
  2. Resolve the fault on the specified device, in accordance with its documentation.
  3. Check that the alert disappears.

Resolution: the alert disappears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.

Welding cycle

Welding alarms: values from the last cycle are outside the limits set in Equipment Settings > Welding Parameters, under the Welding Limits panel. Each alarm results in the workpiece being rejected and prevents the next cycle from starting until a Reset is performed.

M25000-0.XX - Welding cycle - Lower limit of welding time not exceeded

What this means: the Welding time for the last cycle is less than the Lower limit set in Equipment settings > Welding parameters, Welding limits panel: the weld reached the end depth too early. On IR and HP machines, this refers to the joining phase following preheating (the cooling lines on the panel).

Effect: Warning (yellow line). The workpiece is declared a scrap piece (reason shown on the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In test cycles, the limits are not monitored.

Probable causes:

  • workpieces with excess material or incorrectly positioned, which reach the depth immediately;
  • lower limit set too high (Welding time configuration setting).

How to resolve:

  1. Check parts and tools: ensure parts are correct, fully inserted, and that there are no previously welded parts or foreign objects (see Check tools).
  2. Compare the time shown in Last cycle results with the limits in Tool settings > Welding parameters, under the Welding limits panel.
  3. If the parts are sound and the time is stable, ask the tool manager to adjust the limit.

Reset: clear the alarm using Reset in the Alarm Monitor; check the rejected part before restarting.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Welding time settings

How to identify it: the variation in welding time recurs with good parts and a stable welding time.

Check:

  1. Compare the Welding time in Last cycle results with the Lower limit and Upper limit in Tool settings > Welding parameters, Welding limits panel.

Remedy: the tool manager corrects the limits based on the good parts.

Check tools

How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.

Check:

  1. Check that the tool is undamaged and correctly assembled.
  2. Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
  3. Check that the parts are the correct ones.

Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M25001-0.XX - Welding cycle - Upper limit of welding time reached

What this means: the Welding time has reached the Upper limit set in Tool settings > Welding parameters, under the Welding limits panel: welding is stopped immediately. On machines with vibration, the limit cannot exceed the VCU’s vibration time-out. On IR and HP machines, it refers to the joining phase following heating (the cooling lines on the panel).

Effect: Warning (yellow line). The workpiece is declared a reject (reason shown in the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In vacuum cycles, the limits are not monitored.

Probable causes:

  • parts that do not melt or sink as expected;
  • insufficient force, amplitude or power;
  • upper limit set too low (Welding time configuration setting).

How to resolve:

  1. Check the parts and tools: correct parts, fully inserted, no previously welded parts or foreign objects (see Check tools).
  2. Check the tools’ welding parameters.
  3. If the parts are sound and the time is stable, have the limit adjusted in Tool Settings > Welding Parameters, under the Welding Limits panel.

Reset: clear the alarm using Reset in the Alarm Monitor; check the scrap piece before restarting.

If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.

Welding time settings

How to identify it: the variation in welding time recurs with good parts and a stable welding time.

Check:

  1. Compare the Welding time in Last cycle results with the Lower limit and Upper limit in Tool settings > Welding parameters, Welding limits panel.

Remedy: the tool manager corrects the limits based on the good parts.

Check tools

How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.

Check:

  1. Check that the tool is undamaged and correctly assembled.
  2. Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
  3. Check that the parts are the correct ones.

Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M25002-0.XX – Welding cycle – Lower limit of welding start position not exceeded

What this means: the Welding Start Position is below the Lower Limit set in Equipment Settings > Welding Parameters, under the Welding Limits panel: the workpieces have come into contact lower down than expected. The check takes place at the end of stabilisation and then continuously: if out of limit, welding will not start or will be interrupted.

Effect: Warning (yellow line). The workpiece is declared a reject (reason shown in the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. During test cycles, the limits are not monitored.

Probable causes:

  • workpiece missing, shorter than required or not fully inserted;
  • tools different from those specified in the loaded parameters;
  • lower limit set too high (under Welding start position configuration).

How to resolve:

  1. Check workpieces and tools: ensure the correct workpieces are used, fully inserted, and that there are no previously welded workpieces or foreign objects (under Check tools).
  2. Compare the position in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Reset: clear by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.

If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Setting the welding start position

How to identify it: the deviation in the welding start position recurs in good parts.

Check:

  1. Compare the Welding start position in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Remedy: the tool manager corrects the limits based on the good parts.

Check tools

How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.

Check:

  1. Check that the tool is undamaged and correctly assembled.
  2. Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
  3. Check that the parts are the correct ones.

Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M25003-0.XX - Welding cycle - Upper limit of welding start position reached

What this means: the Welding Start Position has reached the Upper Limit set in Equipment Settings > Welding Parameters, under the Welding Limits panel: the workpieces have come into contact higher up than expected. The check takes place at the end of stabilisation and then continuously: if the limit is exceeded, welding will not start or will be interrupted.

Effect: Warning (yellow line). The workpiece is declared a reject (reason shown in the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. During idle cycles, the limits are not monitored.

Probable causes:

  • workpiece is too high, duplicated or has already been welded;
  • foreign object in the tools;
  • upper limit set too low (under Welding start position configuration).

How to resolve:

  1. Check workpieces and tools: correct workpieces, fully inserted, no previously welded workpieces or foreign objects (under Check tools).
  2. Compare the height in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Reset: clear by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Setting the welding start position

How to identify it: the deviation in the welding start position recurs in good parts.

Check:

  1. Compare the Welding start position in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Remedy: the tool manager corrects the limits based on the good parts.

Check tools

How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.

Check:

  1. Check that the tool is undamaged and correctly assembled.
  2. Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
  3. Check that the parts are the correct ones.

Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M25004-0.XX - Welding cycle - Lower limit of the end-of-weld position not reached

What this means: the End-of-weld position (average position of the table at the end of cooling) is below the Lower limit set in Equipment settings > Welding parameters, under the Welding limits panel.

Effect: Warning (yellow line). The workpiece is declared a scrap piece (reason shown on the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In idle cycles, the limits are not monitored.

Probable causes:

  • excessive depth;
  • workpieces shorter than expected;
  • lower limit set too high (Welding end position configuration setting).

How to resolve:

  1. Check workpieces and tools: correct workpieces, fully inserted, no previously welded workpieces or foreign objects (see Check tools).
  2. Check the welding parameters.
  3. Compare the height in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Reset: reset by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.

If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.

Setting the end-of-welding position

How to identify it: the deviation in the end-of-welding height recurs in good parts.

Check:

  1. Compare the End-of-weld dimension in Last welding cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Remedy: the tool manager corrects the limits based on the good parts.

Check tools

How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.

Check:

  1. Check that the tool is undamaged and correctly assembled.
  2. Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
  3. Check that the parts are the correct ones.

Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M25005-0.XX - Welding cycle - Upper limit of the end-of-weld position reached

What this means: the End-of-weld position (average position of the table at the end of cooling) has reached the Upper limit set in Equipment settings > Welding parameters, under the Welding limits panel.

Effect: Warning (yellow line). The workpiece is declared a scrap piece (reason shown in the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In dry runs, the limits are not monitored.

Probable causes:

  • insufficient depth;
  • workpieces taller than expected or foreign objects;
  • upper limit set too low (Welding End Height Configuration setting).

How to resolve:

  1. Check the workpieces and tools: ensure the correct workpieces are used, that they are fully inserted, and that there are no previously welded workpieces or foreign objects (see Check tools).
  2. Check the welding parameters.
  3. Compare the height in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Reset: reset by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.

If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.

Setting the end-of-welding position

How to identify it: the deviation in the end-of-welding height recurs in good parts.

Check:

  1. Compare the End-of-weld dimension in Last welding cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Remedy: the tool manager corrects the limits based on the good parts.

Check tools

How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.

Check:

  1. Check that the tool is undamaged and correctly assembled.
  2. Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
  3. Check that the parts are the correct ones.

Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M25006-0.XX – Welding cycle – Lower limit of welding depth not exceeded

What this means: the Weld depth (the difference between the position at the end of cooling and the welding start position) is below the Lower limit set in Tool settings > Welding parameters, under the Welding limits panel: the workpieces have not been submerged deeply enough.

Effect: Warning (yellow line). The workpiece is declared a reject (reason shown in the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In dry runs, the limits are not monitored.

Probable causes:

  • insufficient welding time, energy or force;
  • non-compliant workpieces;
  • lower limit set too high (Welding Depth Configuration setting).

How to resolve:

  1. Check workpieces and tools: correct workpieces, fully inserted, no previously welded workpieces or foreign objects (see Check tools).
  2. Check the welding parameters.
  3. Compare the depth in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Reset: clear by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.

If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.

Welding depth settings

How to identify it: the variation in welding depth is consistent across good parts.

Check:

  1. Compare the Welding depth in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Remedy: the tool manager corrects the limits based on the good parts.

Check tools

How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.

Check:

  1. Check that the tool is undamaged and correctly assembled.
  2. Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
  3. Check that the parts are the correct ones.

Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M25007-0.XX - Welding cycle - Upper limit of welding depth reached

What this means: the Weld depth (the difference between the position at the end of cooling and the welding start position) has reached the Upper limit set in Equipment settings > Welding parameters, under the Welding limits panel: the workpieces have sunk too far.

Effect: Warning (yellow line). The workpiece is declared a scrap piece (reason shown on the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In idle cycles, the limits are not monitored.

Probable causes:

  • excessive welding time, energy or force;
  • non-compliant workpieces;
  • upper limit set too low (Welding depth configuration setting).

How to resolve:

  1. Check workpieces and tools: correct workpieces, fully inserted, no previously welded workpieces or foreign objects (see Check tools).
  2. Check the welding parameters.
  3. Compare the depth in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Reset: clear by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.

If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.

Welding depth settings

How to identify it: the variation in welding depth is consistent across good parts.

Check:

  1. Compare the Welding depth in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Remedy: the tool manager corrects the limits based on the good parts.

Check tools

How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.

Check:

  1. Check that the tool is undamaged and correctly assembled.
  2. Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
  3. Check that the parts are the correct ones.

Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M25008-0.XX - Welding cycle - Lower limit of switching time not exceeded

What this means: the Switching time (from the end of the heating phase to when the workpieces come into contact) is below the Lower limit set in Tool settings > Welding parameters, under the Welding limits panel.

Effect: Warning (yellow line). The workpiece is declared a scrap piece (reason shown on the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In vacuum cycles, the limits are not checked.

Possible causes:

  • dimensions or output speeds of the mirror or blade, or approach speeds of the axes, differ from those specified;
  • lower limit set too high.

How to resolve:

  1. Check the Clearance and Workpiece contact distances in Tool settings > Positions.
  2. Compare the time in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.

Reset: clear using Reset in the Alarm monitor; check the scrap piece before restarting.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP hot plate machines (HP9, HP14, HP20, HP-P125).

M25009-0.XX - Welding cycle - Upper limit of switching time exceeded

What this means: the Switching time (from the end of heating to contact between the workpieces) has exceeded the Upper limit set in Tool settings > Welding parameters, Welding limits panel: the heated surfaces may have cooled down before contact.

Effect: Warning (yellow line). The workpiece is declared a reject (reason shown in the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In vacuum cycles, the limits are not monitored.

Probable causes:

  • movement of the mirror or blade is slowed down or obstructed;
  • contact with the workpieces is achieved too late;
  • upper limit set too low.

How to resolve:

  1. Check that the mirror or blade and the axes move freely.
  2. Check the dimensions in Tool Settings > Positions and the limits in Tool Settings > Welding Parameters, Welding Limits panel.

Reset: press Reset in the Alarm Monitor; check the scrap piece before restarting.

Safety:

Warning The IR mirror and hot plate remain hot for a long time: only approach them when the machine is in a safe state as per the user manual, once they have cooled down.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP machines with hot plates (HP9, HP14, HP20, HP-P125).

Door

Alarms relating to the machine’s doors (up to ten): door not closed or not locked. These are configured under Machine Settings > General Settings > Components, on the Doors tab.

M26000-0.XX - Door - Unlocked

What this means: the door has been closed for more than 1 s but its electric lock has not been reset: the unlocking, initiated manually or during a tool change using Door Unlock (in the Quick Actions menu on the control panel), is still active. In the code, XX is the door number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • lock not reset after opening;
  • door not fully closed (Door locking);
  • faulty electric lock or sensor (Sensors not working).

How to resolve:

  1. Close the door fully.
  2. Tap Door Unlock to reset the lock: when the doors are closed and locked, the padlock icon is grey.
  3. If the lock does not reset: check the electric lock and sensor (maintenance technician).

Reset: disappears automatically when the condition no longer exists.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: only for doors with unlock and reset controls, configured by CEMAS in Machine Settings > General Settings > Components, Doors tab.

Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Door locking

How to recognise this: the door appears to be closed, but the machine does not detect it as closed or locked.

Check:

  1. Open the door and close it firmly until it stops.
  2. Check the Door Unlock indicator (in the Quick Actions menu on the dashboard): it should be grey when all doors are closed and locked.

Remedy: if the warning persists after closing, see Faulty sensors or Door functionality.

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M26001-0.XX – Door – Not closed

What this means: once the emergency has been reset, the door does not remain closed for more than 1 s. In the code, XX is the door number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • door open or not fully closed (Door locking);
  • closure sensor displaced or faulty (Sensors not working);
  • worn hinges or latches (Door functionality).

How to resolve:

  1. Close the door fully.
  2. Check the Door Unlock lock (Quick Actions menu on the frame): green when at least one door is open.
  3. If the door is closed but appears open: check the sensor and strike plate (maintenance technician).

Reset: disappears automatically when the condition no longer applies.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the door is fitted (Machine settings > General settings > Components, Doors tab), option configured by CEMAS.

Door functions

How to identify the problem: the door closes with difficulty, has play or does not reach the sensor.

Check:

  1. Check the hinges, guides and door stop.
  2. Check that the closing sensor is securely fixed and aligned with the door stop.

Remedy: adjust or replace worn components (by a maintenance technician).

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Door locking

How to recognise this: the door appears to be closed, but the machine does not detect it as closed or locked.

Check:

  1. Open the door and close it firmly until it stops.
  2. Check the Door Unlock indicator (in the Quick Actions menu on the dashboard): it should be grey when all doors are closed and locked.

Remedy: if the warning persists after closing, see Faulty sensors or Door functionality.

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Safety feature

Alarms from safety devices (emergency, light curtains, gates, safety edges, doors) have not been reset. These can be configured under Machine Settings > General Settings > Components, on the Safety tab.

M27000-0.XX – Light curtain – Not reset

What this means: the XX safety device has not been reset for at least 0.5 s and has not been bypassed. XX: 01 emergency, 02–03 front and rear safety barriers, 04–05 front gate and rear gate, 06–07 front and rear gate safety edges, 08–17 doors 1 to 10.

Effect: Alarm (red line): in the case of emergency, safety edges and doors, the machine switches to manual mode; the automatic cycle and tool change remain blocked. The barriers only lock during the cycle when the gate is not closed; for gates, this is merely an indication.

Probable causes:

  • device obstructed, open or pressed (Reset the light curtain);
  • light curtain misaligned (Check alignment) or damaged (Light curtain functionality).

How to resolve:

  1. Disengage the emergency stop, close doors and gates, clear the barrier, then reset the safety devices.
  2. If the barrier remains in alarm mode: clean it and check its alignment and error codes (maintenance technician).

Emergency restore: edges and doors clear automatically upon restore; barriers via Reset.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the safety device is fitted (Machine settings > General settings > Components, Safety tab), option configured by CEMAS.

Functions of light curtains

How to identify the problem: the barrier remains in alarm mode even when there are no obstacles, or the LEDs indicate a fault.

Check:

  1. Check that the lenses are clean and undamaged.
  2. Check the LEDs and any error codes displayed by the barrier.

Remedy: clean the lenses with an anti-static cloth; replace any damaged components (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check alignment

How to recognise it: the light curtain is interrupted without any obstacles or intermittently, for example following an impact.

Check:

  1. Check the alignment between the transmitter and receiver using the light curtain’s indicators.
  2. Check that the brackets are not loose.

Remedy: realign the light barrier in accordance with its manual (maintenance technician).

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.
Reset the light curtain

How to recognise this: the safety device has been triggered and has not been reset.

Check:

  1. Check that no object or person is obstructing the barrier.
  2. Check that emergency exits, doors and gates have been reset.

Remedy: clear the barrier, reset the safety devices in accordance with the user manual and press Reset on the Alarm Monitor.

Warning Before entering the tools area, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Sliding plane

Alarms for the sliding table, which moves the tools between the loading, welding, undercut and tool change positions: axis and drive, positions and shutter (clamp).

The table is configured under Machine Settings > General Settings > Components, on the Sliding Table tab, and is controlled manually via Machine Diagnostics > Manual Movements, under the Machine tab > Axes > Sliding Table.

Availability: only on models with a sliding table (950-ST, 950-HL, 999-HL, 999-XT). Machine option: appears if the Sliding Table is present (Machine Settings > General Settings > Components, Sliding Table tab, Present).

Tool connector

Alarms relating to the 64-pin tool connectors, in the IO-Link or GVX version, through which the welding machine communicates with the input and output modules fitted to the tool: device not configured, unreachable or faulty. The pin status can be viewed under Tool Change > Tool Change, on the Pin Decoding tab.

The connectors are configured under Machine Settings > General Settings > Tool Interfaces, in the zone tab, under the Connectors tab.

M29100-3.XX - Mirror (rear/left) - 64-pin tool connectors - Device not configured

What this means: The tool’s IO-Link module connected to the 64-pin connector on the mirror is not configured in the PLC network. Checked with the IO-Link connector selected and the tool present.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • New or replaced device not yet configured;
  • Machine configuration not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Resolution: the error clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: supplied with the IO-Link connector; option configured by CEMAS.

Configure device

How to recognise it: the alarm appears as soon as a new tool is connected or after the connector module has been replaced.

Check:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Check that the connector type selected for the tools is the one that has been fitted.

Remedy: have the device configured (by a CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29100-3.XX - Mirror (rear/left) - 64-pin GVX tools connectors - Device not configured

What this means: The tool module connected to the mirror’s 64-pin GVX connector is not configured in the PLC network. Checked with the GVX connector selected and enabled, and the tool present.

Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • new or replaced device not yet configured;
  • machine configuration not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Reset: the message disappears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears when the GVX connector is enabled; option configured by CEMAS.

Configure device

How to recognise it: the alarm appears as soon as a new tool is connected or after the connector module has been replaced.

Check:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Check that the connector type selected for the tools is the one that has been fitted.

Remedy: have the device configured (by a CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29100-1.XX - Head - 64-pin GVX tools connectors - Device not configured

What this means: The tool module connected to the 64-pin GVX connector on the head is not configured in the PLC network. Checked with the GVX connector selected and enabled, and the tool present.

Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • new or replaced device not yet configured;
  • machine configuration not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Resolution: the issue resolves itself once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears when the GVX connector is enabled, an option configured by CEMAS.

Configure device

How to recognise it: the alarm appears as soon as a new tool is connected or after the connector module has been replaced.

Check:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Check that the connector type selected for the tools is the one that has been fitted.

Remedy: have the device configured (by a CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29100-2.XX - Table - 64-pin tool connectors - Device not configured

What this means: The tool’s IO-Link module connected to the table’s 64-pin connector is not configured on the PLC network. Checked with the IO-Link connector selected and the tool present.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • New or replaced device not yet configured;
  • Machine configuration not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Reset: the error clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears with the IO-Link connector; option configured by CEMAS.

Configure device

How to recognise it: the alarm appears as soon as a new tool is connected or after the connector module has been replaced.

Check:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Check that the connector type selected for the tools is the one that has been fitted.

Remedy: have the device configured (by a CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29000-1.XX - Head - Tool connector - 64-pin connector fault

What this means: Summary of alarms for the head’s 64-pin IO-Link connector: this is active when any of them are active.

Effect: alert not displayed in the Alarm Monitor: this stops the machine in the same way as connector alarms, which appear in the Alarm Monitor with their respective codes.

How to resolve:

  1. Check the Alarm Monitor for the active 64-pin connector alarm and follow the procedure.

Reset: Disappears automatically when the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

M29100-2.XX - Table - 64-pin GVX tool connectors - Device not configured

What this means: The tool module connected to the 64-pin GVX connector on the table is not configured in the PLC network. Checked with the GVX connector selected and enabled, and the tool present.

Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic machine cycle.

Possible causes:

  • new or replaced device not yet configured;
  • machine configuration not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Resolution: the issue resolves itself once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears when the GVX connector is enabled; this option is configured by CEMAS.

Configure device

How to recognise it: the alarm appears as soon as a new tool is connected or after the connector module has been replaced.

Check:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Check that the connector type selected for the tools is the one that has been fitted.

Remedy: have the device configured (by a CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29100-1.XX - Head - 64-pin tool connectors - Device not configured

What this means: The tool’s IO-Link module connected to the head’s 64-pin connector is not configured on the PLC network. Checked with the IO-Link connector selected and the tool present.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • New or replaced device not yet configured;
  • Machine configuration not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Resolution: the error clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears with the IO-Link connector, an option configured by CEMAS.

Configure device

How to recognise it: the alarm appears as soon as a new tool is connected or after the connector module has been replaced.

Check:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Check that the connector type selected for the tools is the one that has been fitted.

Remedy: have the device configured (by a CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29000-3.XX – Mirror (rear/left) – Tool connector – 64-pin connector fault

What this means: Summary of alarms for the mirror’s 64-pin IO-Link connector: this is active when any of them are active.

Effect: alert not displayed in the Alarm Monitor: this stops the machine in the same way as connector alarms, which appear in the Alarm Monitor with their respective codes.

How to resolve:

  1. Check the Alarm Monitor for the active 64-pin connector alarm and follow the procedure.

Reset: Disappears automatically when the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

M29000-2.XX - Table - Tool connector - 64-pin connector fault

What this means: Summary of alarms for the table’s 64-pin IO-Link connector: this is active when any of them are active.

Effect: alert not displayed in the Alarm Monitor: this stops the machine in the same way as connector alarms, which appear in the Alarm Monitor with their respective codes.

How to resolve:

  1. Check the Alarm Monitor for the active 64-pin connector alarm and follow the procedure.

Reset: the alarm clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

M29101-3.XX - Mirror (rear/left) - 64-pin GVX tool connectors - Device not accessible

What this means: The PLC is unable to communicate with the tool module connected to the 64-pin GVX connector on the mirror. Checked with the GVX connector selected and enabled, and the tool present.

Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • device switched off or not powered;
  • network cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; in Machine Diagnostics > PLC, on the PLC Hardware tab, the device must show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: the alarm clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears when the GVX connector is enabled; this option is configured by CEMAS.

Turning on the device

How to identify the problem: the tool’s input and output module has its LEDs off and no signals are being received from the tools.

Check:

  1. Check that the tool’s plug is connected and that the module’s power LEDs are lit.
  2. Check the status of the connector pins in Tool Change > Tool Change, under the Pin Decoding tab.

Remedy: re-establish the connection or restore power to the module (by a maintenance technician).

Check the message

How to identify the problem: the tool module is powered on but the PLC cannot communicate with it.

Check:

  1. Check the module’s communication LED.
  2. Check under Machine Diagnostics > PLC, on the PLC Hardware tab, to see if the device is showing an error, and check the cable and plug contacts.

Remedy: clean or replace damaged contacts and cables (maintenance technician); if the module has been replaced, have its configuration checked (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29101-2.XX - Table - 64-pin GVX tool connectors - Device not accessible

What this means: The PLC is unable to communicate with the tool module connected to the table’s 64-pin GVX connector. Checked with the GVX connector selected and enabled, and the tools present.

Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle.

Possible causes:

  • device switched off or not powered;
  • network cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; under Machine Diagnostics > PLC, on the PLC Hardware tab, the device should show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: the alarm clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears when the GVX connector is enabled; this option is configured by CEMAS.

Turning on the device

How to identify the problem: the tool’s input and output module has its LEDs off and no signals are being received from the tools.

Check:

  1. Check that the tool’s plug is connected and that the module’s power LEDs are lit.
  2. Check the status of the connector pins in Tool Change > Tool Change, under the Pin Decoding tab.

Remedy: re-establish the connection or restore power to the module (by a maintenance technician).

Check the message

How to identify the problem: the tool module is powered on but the PLC cannot communicate with it.

Check:

  1. Check the module’s communication LED.
  2. Check under Machine Diagnostics > PLC, on the PLC Hardware tab, to see if the device is showing an error, and check the cable and plug contacts.

Remedy: clean or replace damaged contacts and cables (maintenance technician); if the module has been replaced, have its configuration checked (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29101-1.XX - Head - 64-pin GVX tool connectors - Device not accessible

What this means: The PLC is unable to communicate with the tool module connected to the 64-pin GVX connector on the head. Checked with the GVX connector selected and enabled, and the tools present.

Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic machine cycle.

Probable causes:

  • device switched off or not powered;
  • network cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; under Machine Diagnostics > PLC, on the PLC Hardware tab, the device should show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: the alarm clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears when the GVX connector is enabled, an option configured by CEMAS.

Turning on the device

How to identify the problem: the tool’s input and output module has its LEDs off and no signals are being received from the tools.

Check:

  1. Check that the tool’s plug is connected and that the module’s power LEDs are lit.
  2. Check the status of the connector pins in Tool Change > Tool Change, under the Pin Decoding tab.

Remedy: re-establish the connection or restore power to the module (by a maintenance technician).

Check the message

How to identify the problem: the tool module is powered on but the PLC cannot communicate with it.

Check:

  1. Check the module’s communication LED.
  2. Check under Machine Diagnostics > PLC, on the PLC Hardware tab, to see if the device is showing an error, and check the cable and plug contacts.

Remedy: clean or replace damaged contacts and cables (maintenance technician); if the module has been replaced, have its configuration checked (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29101-3.XX - Mirror (rear/left) - 64-pin tool connectors - Device not accessible

What this means: The PLC is unable to communicate with the tool’s IO-Link module connected to the 64-pin connector on the mirror. Checked with the IO-Link connector selected and the tool present.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device switched off or not powered;
  • network cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; under Machine Diagnostics > PLC, on the PLC Hardware tab, the device must show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: the alarm clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: supplied with the IO-Link connector; option configured by CEMAS.

Turning on the device

How to identify the problem: the tool’s input and output module has its LEDs off and no signals are being received from the tools.

Check:

  1. Check that the tool’s plug is connected and that the module’s power LEDs are lit.
  2. Check the status of the connector pins in Tool Change > Tool Change, under the Pin Decoding tab.

Remedy: re-establish the connection or restore power to the module (by a maintenance technician).

Check the message

How to identify the problem: the tool module is powered on but the PLC cannot communicate with it.

Check:

  1. Check the module’s communication LED.
  2. Check under Machine Diagnostics > PLC, on the PLC Hardware tab, to see if the device is showing an error, and check the cable and plug contacts.

Remedy: clean or replace damaged contacts and cables (maintenance technician); if the module has been replaced, have its configuration checked (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29101-2.XX - Table - 64-pin tool connectors - Device not accessible

What this means: The PLC is unable to communicate with the tool’s IO-Link module connected to the table’s 64-pin connector. Checked with the IO-Link connector selected and the tool present.

Effect: Alarm (red line): the machine switches to manual mode (a welding process results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device switched off or not powered;
  • network cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; under Machine Diagnostics > PLC, on the PLC Hardware tab, the device should show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: the alarm clears automatically when the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears with the IO-Link connector; this option is configured by CEMAS.

Turning on the device

How to identify the problem: the tool’s input and output module has its LEDs off and no signals are being received from the tools.

Check:

  1. Check that the tool’s plug is connected and that the module’s power LEDs are lit.
  2. Check the status of the connector pins in Tool Change > Tool Change, under the Pin Decoding tab.

Remedy: re-establish the connection or restore power to the module (by a maintenance technician).

Check the message

How to identify the problem: the tool module is powered on but the PLC cannot communicate with it.

Check:

  1. Check the module’s communication LED.
  2. Check under Machine Diagnostics > PLC, on the PLC Hardware tab, to see if the device is showing an error, and check the cable and plug contacts.

Remedy: clean or replace damaged contacts and cables (maintenance technician); if the module has been replaced, have its configuration checked (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29101-1.XX - Head - 64-pin tool connectors - Device not accessible

What this means: The PLC is unable to communicate with the tool’s IO-Link module connected to the 64-pin connector on the head. Checked with the IO-Link connector selected and the tool present.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device switched off or not powered;
  • network cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; under Machine Diagnostics > PLC, on the PLC Hardware tab, the device should show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: the alarm clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears with the IO-Link connector, an option configured by CEMAS.

Turning on the device

How to identify the problem: the tool’s input and output module has its LEDs off and no signals are being received from the tools.

Check:

  1. Check that the tool’s plug is connected and that the module’s power LEDs are lit.
  2. Check the status of the connector pins in Tool Change > Tool Change, under the Pin Decoding tab.

Remedy: re-establish the connection or restore power to the module (by a maintenance technician).

Check the message

How to identify the problem: the tool module is powered on but the PLC cannot communicate with it.

Check:

  1. Check the module’s communication LED.
  2. Check under Machine Diagnostics > PLC, on the PLC Hardware tab, to see if the device is showing an error, and check the cable and plug contacts.

Remedy: clean or replace damaged contacts and cables (maintenance technician); if the module has been replaced, have its configuration checked (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29102-3.XX – Mirror (rear/left) – 64-pin tool connectors – Hardware fault indicator

What this means: The IO-Link module on the tool connected to the 64-pin connector on the mirror is sending signals of a hardware fault. Checked with the selected IO-Link connector and the tool present.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again and check whether the fault reoccurs.
  2. If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears itself once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: supplied with the IO-Link connector; option configured by CEMAS.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29102-2.XX - Table - 64-pin tool connectors - Hardware fault

What this means: The IO-Link module on the tool connected to the 64-pin connector on the table is sending signals of a hardware fault. Checked with the selected IO-Link connector and the tool present.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again and check whether the fault reoccurs.
  2. If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears with the IO-Link connector; this option is configured by CEMAS.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29102-2.XX - Table - 64-pin GVX tool connectors - Hardware error device

What this means: The tool module connected to the 64-pin GVX connector on the table is sending signals of a hardware fault. Checked with the GVX connector selected and enabled, and the tools present.

Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again and check whether the fault reoccurs.
  2. If it persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears when the GVX connector is enabled; this option is configured by CEMAS.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29102-3.XX – Mirror (rear/left) – 64-pin GVX tools – Hardware fault indicator

What this means: The tool module connected to the mirror’s 64-pin GVX connector is signaling a hardware fault. Checked with the GVX connector selected and enabled, and the tool present.

Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again and check whether the fault reoccurs.
  2. If it persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Machine option: appears when the GVX connector is enabled; option configured by CEMAS.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29102-1.XX - Header - 64-pin tool connectors - Hardware error device

What this means: The IO-Link module on the tool connected to the 64-pin connector on the head is sending signals of a hardware fault. Checked with the selected IO-Link connector and the tool present.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again and check whether the fault reoccurs.
  2. If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears with the IO-Link connector, an option configured by CEMAS.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M29102-1.XX - Header - 64-pin GVX tool connectors - Hardware error device

What this means: The tool module connected to the 64-pin GVX connector on the head is sending signals of a hardware fault. Checked with the GVX connector selected and enabled, and the tool present.

Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again and check whether the fault reoccurs.
  2. If it persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears automatically once the device returns to normal operation.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears when the GVX connector is enabled, an option configured by CEMAS.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Presence and position

Alarms from the presence and position sensors for the tools on the head, table and mirror: tools missing when required, not positioned correctly, or present when the machine has not loaded them.

The sensors are configured under Machine Settings > General Settings > Tool Interfaces, in the zone tab, under the Presences and Positions tab.

M30000-1.XX - Head - Presence and position - Tool not present

What this means: The presence sensor on the head does not detect the tools when they should be present: when the clamp is active or when the tools are loaded into the PLC. The alarm is logged.

Effect: Alarm (red line): the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • tool not fitted or not seated correctly;
  • presence sensor out of calibration, dirty or faulty.

How to resolve:

  1. Check that the tool is fitted and seated correctly.
  2. Check the sensor LED and its input under Machine Diagnostics > PLC, Card Monitoring tab; adjust, clean or replace the sensor (maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M30000-3.XX – Mirror (rear/left) – Presence and position – Tools not fitted

What this means: The presence sensor on the mirror does not detect the tool when it should: with the tool loaded into the PLC and the mirror in use. The alarm is logged.

Effect: Alarm (red line): the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • tool not fitted or not seated correctly;
  • presence sensor out of calibration, dirty or faulty.

How to resolve:

  1. Check that the tool is fitted and seated correctly.
  2. Check the sensor LED and its input under Machine Diagnostics > PLC, Card Monitoring tab; adjust, clean or replace the sensor (maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M30000-2.XX - Table - Presence and position - Tools not present

What this means: The presence sensor on the table does not detect the tools when they should be present: when the clamp mechanism is activated during operation or when the tools are loaded into the PLC. The alarm is logged.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • tool not fitted or not seated correctly;
  • presence sensor out of calibration, dirty or faulty.

How to resolve:

  1. Check that the tool is fitted and seated correctly.
  2. Check the sensor LED and its input under Machine Diagnostics > PLC, Card Monitoring tab; adjust, clean or replace the sensor (maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M30001-1.XX – Head – Presence and position – Tool not in the correct position

What this means: The head-mounted tools are present but the position sensor does not confirm the correct position: after the Position error delay set in Machine settings > General settings > Tool interfaces, Head tab, Presences and positions tab (typically 2 seconds, s), or immediately if the clamp is controlled during operation or the tool is loaded. The alarm remains stored.

Effect: Alarm (red line): the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • tool poorly positioned or not centred;
  • foreign objects beneath the tooling;
  • position sensor out of calibration or faulty.

How to resolve:

  1. Check that the tool is centred and correctly positioned with no foreign objects present; reposition it if necessary.
  2. Check the position sensor LED and its input in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace it (by a maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M30001-2.XX - Table - Presence and position - Tool not in the correct position

What this means: The tool is present on the table but the position sensor does not confirm the correct position: after the Position error delay set in Machine settings > General settings > Tool interfaces, Table tab, Presences and positions tab (typically 2 seconds, s), or immediately if the clamp is controlled during operation or the tools are loaded. The alarm remains stored.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • tool poorly positioned or not centred;
  • foreign objects beneath the tooling;
  • position sensor out of calibration or faulty.

How to resolve:

  1. Check that the tool is centred and correctly positioned with no foreign objects present; reposition it if necessary.
  2. Check the position sensor LED and its input in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace it (by a maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M30001-3.XX - Mirror (rear/left) - Presence and position - Tool not in the correct position

What this means: The tools on the mirror are present but the position sensor does not confirm the correct position: after the Position error delay set in Machine settings > General settings > Tool interfaces, Mirror tab, Presences and positions tab (typically 2 seconds, s), or immediately if the clamp is controlled during operation or the tool is loaded. The alarm remains stored.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • tool poorly positioned or not centred;
  • foreign objects beneath the tools;
  • position sensor out of calibration or faulty.

How to resolve:

  1. Check that the tools are centred and correctly positioned with no foreign objects present; reposition them if necessary.
  2. Check the position sensor LED and its input in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace it (by a maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

Assembly of tools

How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.

Check:

  1. Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
  2. Check that the centerings fit into their sockets and that the interface plate is in the correct position.
  3. Repeat the loading of the tools from the tool change.

Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M30002-3.XX - Mirror (rear/left) - Presence and position - Present

What this means: A sensor on the mirror detects a tool that the machine is not expecting, for example before the mirror is loaded, or even during a tool change. The alarm is logged.

Effect: Alarm (red line): the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • Previous tool not unloaded or tool data not loaded;
  • presence sensor is always active.

How to resolve:

  1. If the tools are fitted, load their data from Tool Change > Tool Change, Manual tab (Load Tools) or unload them using the unloading procedure.
  2. If there are no tools, check the sensor and its input in Machine Diagnostics > PLC, Card Monitoring tab (maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

Dismantle tools

How to recognise this: a sensor detects that a tool is fitted, but the machine has not loaded its data, or the previous tool has remained fitted.

Check:

  1. Check in Tool Change > Tool Change, under the Manual tab, whether the tool data has been loaded.
  2. Visually check whether the tool (or the part indicated by the alarm) is fitted.

Remedy: if the correct tool is fitted, load its data (Load Tool); otherwise, unload it using the unloading procedure in Tool Change > Tool Change.

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M30002-2.XX - Table - Presence and position - Tools present

What this means: A sensor on the table detects a tool that the machine has not loaded (or has loaded without parameters) whilst a movement, an actuator or the start of a cycle is being commanded. This is not checked during tool change. The alarm is stored.

Effect: Alarm (red line): the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • previous tool not unloaded or tool data not loaded;
  • presence sensor is always active.

How to resolve:

  1. If the tools are fitted, load their data from Tool Change > Tool Change, Manual tab (Load Tools) or unload them using the unloading procedure.
  2. If there are no tools, check the sensor and its input in Machine Diagnostics > PLC, Card Monitoring tab (maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Dismantle tools

How to recognise this: a sensor detects that a tool is fitted, but the machine has not loaded its data, or the previous tool has remained fitted.

Check:

  1. Check in Tool Change > Tool Change, under the Manual tab, whether the tool data has been loaded.
  2. Visually check whether the tool (or the part indicated by the alarm) is fitted.

Remedy: if the correct tool is fitted, load its data (Load Tool); otherwise, unload it using the unloading procedure in Tool Change > Tool Change.

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M30002-1.XX - Head - Presence and position - Tools present

What this means: A sensor on the head detects a tool that the machine has not loaded whilst a movement or the start of a cycle is being commanded. On IR and HP machines, this is also monitored during tool change. The alarm is stored.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • previous tool not unloaded or tool data not loaded;
  • presence sensor is always active.

How to resolve:

  1. If the tooling is fitted, load its data from Tool Change > Tool Change, Manual tab (Load Tooling) or unload it using the unloading procedure.
  2. If there are no tools, check the sensor and its input in Machine Diagnostics > PLC, Card Monitoring tab (maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate.

Dismantle tools

How to recognise this: a sensor detects that a tool is fitted, but the machine has not loaded its data, or the previous tool has remained fitted.

Check:

  1. Check in Tool Change > Tool Change, under the Manual tab, whether the tool data has been loaded.
  2. Visually check whether the tool (or the part indicated by the alarm) is fitted.

Remedy: if the correct tool is fitted, load its data (Load Tool); otherwise, unload it using the unloading procedure in Tool Change > Tool Change.

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Automatic cycle

Automatic cycle alarms: cycle duration, cavity selection, part contact, fire safety procedure and rejection confirmation. Some stop the cycle and switch the machine back to manual mode, whilst others are simply warnings: each item specifies this.

M31000-0.XX – Automatic cycle – Maximum cycle time

What this means: the duration of the automatic cycle has exceeded the Maximum set in the Cycle time tab under Machine settings > Configuration. With Maximum set to 0, this message appears at every cycle. Not checked during the test cycle.

Effect: Warning (yellow line). Warning only: the cycle continues and the part is not rejected.

Possible causes:

  • cycle slowed down by delays (confirmations, actuators or slow presences);
  • Maximum set too low or at 0 (Cycle not completed entry).

How to resolve:

  1. Identify the cycle phase that is slower than usual on the CONTROL PAGE.
  2. Eliminate the cause of the slowdown (actuators, presences, operator delays).
  3. If the duration is correct, ask the tool manager to increase the Maximum.

Reset: stored alarm; clear it using Reset in the Alarm Monitor after eliminating the cause.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and checks carried out.

Cycle not completed

How to recognise it: the maximum cycle time warning appears at every cycle, even without any obvious slowdowns.

Check:

  1. Compare the actual cycle time with the Maximum value on the Cycle Time tab under Tool Settings > Configuration.
  2. Check that the Maximum is not set to 0.

Remedy: the tool manager sets a Maximum value appropriate to the actual cycle time.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M31001-0.XX – Automatic cycle – Minimum cycle time

What this means: at the end of the cycle, the Minimum time set in the Cycle time tab under Tool settings > Configuration (time counted from start-up) has not elapsed.

Effect: Warning (yellow line). Information only: the cycle ends and the part is not rejected.

Possible causes:

  • a cycle phase has been skipped or is shorter than expected;
  • Minimum set too high (see Cycle not completed).

How to resolve:

  1. Check that all cycle phases have been carried out and that the workpiece complies.
  2. If the duration is correct, ask the tool manager to reduce the Minimum.

Reset: alarm stored; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.

Cycle not completed

How to recognise it: the minimum cycle time warning appears with good parts and complete cycles.

Check:

  1. Compare the actual cycle time with the Minimum value on the Cycle Time card under Tool Settings > Configuration.

Remedy: the tool manager reduces the Minimum value based on the actual cycle time.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M31002-0.XX - Automatic cycle - No cavity selected

What this means: With automatic cavity selection, the clamp command has been issued, but neither the LH nor RH workpiece presence sensor detects a workpiece: the machine does not know which cavity to weld.

Effect: Alarm (red line). The automatic cycle is interrupted and the machine switches to manual mode; whilst this mode is active, neither the automatic cycle nor tool change can be initiated.

Probable causes:

  • workpiece not inserted or not detected by the presence sensors;
  • faulty or misaligned workpiece presence sensor;
  • cavity selection set incorrectly (Select cavity option).

How to resolve:

  1. Insert the part correctly before issuing the clamp command.
  2. Check that the cavity presence indicator lights up when the part is inserted (Machine Diagnostics > Manual Movements, Presences tab).
  3. Check Model Selection and Cavity Configuration in Tool Settings > Configuration.

Reset: stored alarm; clear it by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.

Select cavity

How to identify the problem: the cycle stops at the ‘No cavity selected’ alarm when the clamp is engaged.

Check:

  1. Check Tool Settings > Configuration under Model Selection and Cavity Configuration.
  2. With automatic selection, check that the cavity presence indicator lights up when the workpiece is inserted.

Remedy: with manual selection, choose LH+RH, LH or RH before starting; with automatic selection, the workpiece must be inserted before the clamp command is given.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M31003-0.XX – Automatic cycle – Workpiece contact timeout

What this means: during the contact phase between the workpieces, the axes remain stationary for 5 s (fixed value) without detecting contact or reaching the clamp force.

Effect: Alarm (red line). The automatic cycle is interrupted and the machine switches to manual mode; whilst this alarm is active, neither the automatic cycle nor tool change can be initiated.

Probable causes:

  • Incorrect Workpiece contact height, often too high (Workpiece contact height configuration setting);
  • Missing or incorrectly positioned workpieces;
  • Clamp force cannot be achieved.

How to resolve:

  1. Check the components in the tool.
  2. Compare the position of the table at contact (Machine Diagnostics > Motor Status) with Workpiece Contact in Tool Settings > Positions.
  3. Ask the person responsible for the tools to correct the dimension.

Reset: alarm stored; clear it using Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Setting the contact height for workpieces

How to recognise it: the cycle stops during the contact phase with the workpiece contact timeout alarm, even with correct workpieces.

Check:

  1. Compare the table position at the contact point (Machine Diagnostics > Motor Status) with Workpiece Contact in Equipment Settings > Positions.

Remedy: the equipment manager corrects the height (which is often too high) and runs a test cycle.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M31004-0.XX - Automatic cycle - Cycle timeout

What this means: the automatic cycle has not completed within 180 s (fixed value).

Effect: Alarm (red line). The automatic cycle is interrupted and the machine switches to manual mode; whilst this is active, neither the automatic cycle nor tool change can be initiated.

Probable causes:

  • cycle halted whilst awaiting a condition that does not occur (actuator, presence, gate, confirmation);
  • movement blocked without a specific alarm.

How to resolve:

  1. On the CONTROL PAGE, identify the stage at which the cycle has stopped.
  2. Check the condition being awaited at that stage (actuators, presence sensors, gates) and restore it.
  3. Check the stages in Equipment Settings > Cycle Settings.

Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M31005-0.XX – Automatic cycle – Fire-fighting procedure activation

1.25.0

What this means: during the warm-up (IR mirror at full power or hot plate), the table does not return to a safe position within the maximum time allowed, or the machine exits automatic mode. Maximum time: on cam-controlled IR vibration units, Full power 1 + Full power 2 + 15 s; on IR and HP units, the longer of the table and head warm-up times is added, with a minimum of 25 s; 45 s in the test cycle.

Effect: Alarm (red line). The automatic cycle is interrupted and the machine switches to manual mode; whilst this is active, neither automatic mode nor tool change can be initiated. The machine performs an emergency repositioning and displays the fire safety procedure pop-up.

Probable causes:

  • cycle halted during the warm-up phase;
  • movement of the table, head or mirror blocked;
  • output from automatic mode during the warm-up phase.

How to resolve:

  1. Follow the instructions in the pop-up and check that there is no smoke or flames.
  2. Check that there is no molten plastic on the mirror or blade (maintenance technician).
  3. Check the wait times during the warm-up phases in Equipment Settings > Cycle Settings.

Reset: alarm logged; clear by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.

Safety:

Warning Plastic residues on the heating elements or the blade may catch fire: before restarting, have them removed whilst the machine is safely switched off, in accordance with the user manual and whilst the surfaces are cool.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR machines (IR9, IR14, IR20), HP machines with hot plates (HP9, HP14, HP20, HP-P125) and IR cam-driven vibration machines (911MK2-IR, 918MK2-IR).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M31006-0.XX – Automatic cycle – Confirmation of rejection request

What this means: the cycle has ended with a scrap piece and the machine is awaiting confirmation from the operator before opening the gates and releasing the parts.

Effect: Warning (yellow line). The current cycle remains paused; the automatic cycle cannot be restarted until confirmation is given.

How to resolve:

  1. Confirm the reject using the button with the tick symbol in the SCRAP PIECE(S) box under Machine Status > CONTROL PAGE.
  2. With Confirm request with login, log in using a user account authorised to Allow tool release.
  3. Separate the scrap piece from the good parts.

Restore: this is only cleared by confirming the rejection; Reset does not clear it.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: Machine option: appears if Rejection behaviour is set to Confirmation required or Confirmation required with login (Machine settings > General settings > Optionals).

Tool loading cycle

Tool loading alerts (Tool Change > Tool Change page): plug type not selected, tool code not read, rear tool change active.

M32000-0.XX - Tool loading cycle - No connector selected

What this means: When the tool load begins, or when Proceed is selected, the Plug type is not selected in Tool settings > Configuration: the machine does not know which connector to read.

Effect: Alarm (red line). The load does not start. Machine alarm: automatic and tool change functions are blocked.

Probable causes:

  • Plug type not set in the tool configuration (Select plug type option).

How to resolve:

  1. Select the Plug type in Tool settings > Configuration and save the parameters.
  2. Repeat the loading process via Tool change > Tool change.

Reset: alarm logged; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.

Select plug type

How to identify the problem: the tool load does not start and a ‘connector not selected’ alarm is triggered.

Check:

  1. Check the plug type in Tool Settings > Configuration.
  2. Check that it matches the plug fitted to the tool.

Solution: select the tool’s plug type, save the parameters and repeat the tool loading process.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M32001-0.XX – Tool loading cycle – Tool code not found

What this means: during the load code check, with the connector plugged in, the tool code is not read within 10 seconds (fixed value).

Effect: Alarm (red line). The load remains stationary. Machine alarm: automatic operation and tool change blocked.

Probable causes:

  • plug not inserted or inserted incorrectly;
  • incorrect or broken coding pin wiring (see Check wiring);
  • code not programmed on the tools.

How to resolve:

  1. Check that the plug is connected.
  2. Check the code displayed in the Pin Decoding tab under Tool Change > Tool Change.
  3. Check the plug wiring (maintenance technician).

Reset: this is cleared upon confirmation of the step or by selecting Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.

Check the wiring

How to identify the problem: the load stops during the code check: the code read is 0 or different from the expected one.

Check:

  1. Check the code in the Pin Decoding tab under Tool Change > Tool Change.
  2. Check that the plug is fully inserted.
  3. Check the wiring of the code pins (maintenance technician).

Remedy: the maintenance technician must rectify the plug wiring; the tool code must be programmed by the tool manager.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Tool unloading cycle

Tool unloading alarms (Tool Change > Tool Change page).

M33000-0.XX - Tool unloading cycle - Unload tool

What this means: The warning (tool unloading) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Warning not displayed in the Alarm Monitor. No effect on the machine.

How to resolve:

  1. If the alert appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Archive management

Alerts relating to cycle data logging (records can be viewed under Machine Status > Production Reports).

M34000-0.XX - Archive management - Buffer full

What this means: the queue in which the PLC stores cycle data awaiting archiving (5 archives) is full: the panel is not acquiring the archives. Whilst the queue is full, data from new cycles is discarded.

Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic cycle. Discarded cycles do not appear in the Production Report.

Probable causes:

  • Panel archiving has stopped or is running slowly;
  • Communication between the panel and the PLC has been interrupted.

How to resolve:

  1. Check that the panel is switched on and connected (no ‘PLC not connected’ message).
  2. Restart the operator panel if data logging does not resume.
  3. Check in Machine Status > Production Report that new cycles are being recorded.

Resolution: the issue resolves itself the first time the panel acquires a log.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M34001-0.XX - Archive management - Acquisition timeout

What this means: the panel did not confirm receipt of a cycle’s data within 2 minutes.

Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • control panel overloaded or data storage blocked;
  • communication between the control panel and the PLC interrupted.

How to resolve:

  1. Check that the control panel is responding and is connected to the PLC.
  2. If the alarm recurs, restart the operator panel.

Resolution: the alarm clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Tool columns

Alarms for equipment columns – the columns that hold equipment parts in a stacked configuration for transport and tool changes and which, once the tools are fitted, must be returned to their storage positions. Presence sensors detect columns inserted into the tools, whilst rest sensors detect those that have been stowed.

The sensors are configured in Machine Settings > General Settings > Tool Interfaces, under the ‘Zone’ tab, in the Tooling Columns section.

M35000-1.XX - Head - Tool columns - Columns not fitted

1.23.12

What this means: The columns on the head are not inserted into the tool during the loading and unloading phases when the tool is to be stacked. The alarm is stored. On the head, this condition halts the machine but does not appear in the Alarm Monitor.

Effect: Alarm (red line): the machine switches to manual mode (a welding process results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • columns not inserted or only partially inserted;
  • column presence sensor out of calibration or faulty.

How to resolve:

  1. Insert all columns into the tool sockets, as required by the current step in Tool Change > Tool Change.
  2. Check the LEDs on the column sensors and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).
  3. Press Reset and resume the procedure.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

M35000-2.XX - Table - Tool columns - Columns not fitted

What this means: The columns on the table are not inserted into the tool during the loading and unloading phases when the tool is to be stacked. The alarm remains stored.

Effect: Alarm (red line): the machine switches to manual mode (a welding process results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • columns not inserted or only partially inserted;
  • column presence sensor out of calibration or faulty.

How to resolve:

  1. Insert all columns into the tool sockets, as required by the current step in Tool Change > Tool Change.
  2. Check the LEDs on the column sensors and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).
  3. Press Reset and resume the procedure.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the tools area, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Check that the columns have been entered

How to recognise this: during loading or unloading, the process stops whilst columns remain undetected in the tools.

Check:

  1. Visually check that all columns are fully inserted into their sockets on the tools.
  2. Check the column sensor LEDs and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab.

Remedy: insert any missing columns; adjust or replace the sensor that is not switching (maintenance technician).

Warning Before working in the area of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M35000-3.XX - Mirror (rear/left) - Tool columns - Columns not fitted

1.23.12

What this means: The columns on the mirror are not inserted into the tool during the loading and unloading phases when the tool is to be stacked. The alarm remains stored.

Effect: Alarm (red line): the machine switches to manual mode (a welding process results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • columns not inserted or only partially inserted;
  • column presence sensor out of calibration or faulty.

How to resolve:

  1. Insert all columns into the tool sockets, as required by the current step in Tool Change > Tool Change.
  2. Check the LEDs on the column sensors and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).
  3. Press Reset and resume the procedure.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

M35001-3.XX - Mirror (rear/left) - Tool columns - Integrated columns

1.23.12

What this means: The columns on the mirror are still fitted to the tool when they should be removed: whilst the tool is loaded, outside the tool change cycle, or at the end of the loading process. The alarm is stored.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • columns not removed at the end of loading;
  • column presence sensor remains active.

How to resolve:

  1. Remove the columns and return them to their storage positions on either side of the fixture.
  2. Check the LEDs on the column sensors and their inputs under Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

M35001-2.XX - Table - Tools columns - Built-in columns

What this means: The columns on the table are still inserted in the tool when they should be removed: whilst the tool is loaded, outside the tool change cycle, or at the end of the loading process. The alarm is stored.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • columns not removed at the end of loading;
  • column presence sensor remains active.

How to resolve:

  1. Remove the columns and return them to their storage positions on either side of the fixture.
  2. Check the LEDs on the column sensors and their inputs under Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Check that the columns have been entered

How to tell: with the tools fitted, the machine sends signals indicating which columns are still in place.

Check:

  1. Visually check whether any columns have been left in the tool.
  2. If the columns have been removed, check that the sensors switch off (Machine Diagnostics > PLC, Card Monitoring tab).

Remedy: remove the columns and return them to their storage positions; replace the sensor that is always active (maintenance technician).

Warning Before working in the area around the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M35001-1.XX - Head - Tool columns - Inserted columns

1.23.12

What this means: The head columns are still fitted to the tool when they should be removed: whilst the tool is loaded, outside the tool change cycle, or at the end of the loading process. The alarm is stored.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • columns not removed at the end of loading;
  • column presence sensor remains active.

How to resolve:

  1. Remove the columns and return them to their storage positions on either side of the fixture.
  2. Check the LEDs on the column sensors and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).
  3. Press Reset.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

M35002-3.XX - Mirror (rear/left) - Tool columns - Columns in the wrong position

What this means: During loading or unloading checks, not all the columns on the platform are in the required position: some are engaged and others are not.

Effect: Alarm (red line): this is for information only; it does not stop the machine or halt the automatic cycle.

Probable causes:

  • one or more columns have not been moved;
  • a column’s sensor is out of calibration or faulty.

How to resolve:

  1. Move all columns to the same position: in the transport tool, or to their rest positions with the tool fitted.
  2. Check the column sensor LEDs and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types of blade: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration blade and cam-type IR vibration blade (911MK2-IR, 918MK2-IR).

M35002-2.XX - Table - Tool columns - Columns in the wrong position

What this means: During loading or unloading checks, not all the columns on the table are in the required position: some are engaged and others are not.

Effect: Alarm (red line): this is for information purposes only; it does not stop the machine or halt the automatic cycle.

Probable causes:

  • one or more columns have not been moved;
  • a column sensor is out of calibration or faulty.

How to resolve:

  1. Move all columns to the same position: in the transport tool, or to their rest positions with the tool fitted.
  2. Check the column sensor LEDs and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Check the position of the columns

How to identify this: some columns are inserted and others are not.

Check:

  1. Visually check the position of each column: all should be in the transport tool, and all should be in their rest positions with the equipment fitted.
  2. Check that each sensor corresponds to the actual column (Machine Diagnostics > PLC, Card Monitoring tab).

Remedy: move all columns to the same position; adjust any sensor that does not correspond (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M35002-1.XX - Head - Tool columns - Columns in the wrong position

1.23.12

What this means: During loading or unloading checks, not all the columns on the head are in the required position: some are engaged and others are not.

Effect: Alarm (red line): this is for information only; it does not stop the machine or halt the automatic cycle.

Probable causes:

  • one or more columns have not been moved;
  • a column sensor is out of calibration or faulty.

How to resolve:

  1. Move all columns to the same position: in the transport tool, or to their rest positions with the tool fitted.
  2. Check the column sensor LEDs and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate.

M35003-3.XX – Mirror (rear/left) – Tool columns – Non-retractable columns

What this means: An alert is provided for columns on the mirror that are not at rest. In current versions of the machine software, the alert is provided but is not activated.

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

M35003-1.XX - Head - Tool columns - Non-resting columns

1.23.12

What this means: An alert is provided for columns on the head that are not at rest. In current versions of the machine software, the alert is provided but is not activated.

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate.

M35004-1.XX - Head - Tools columns - Columns at rest

1.23.12

What this means: Alarm set to trigger for columns at rest. In current versions of the machine software, the alarm is set but is not activated.

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate.

M35004-3.XX - Mirror (rear/left) - Tool columns - Columns in rest position

1.23.12

What this means: Alarm set to trigger for the columns on the mirror when at rest. In current versions of the machine software, the alarm is set but is not activated.

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

IR

Infrared heating alarms: mirror zones (IR lamps), IRM power modules that supply them, grouped into boxes and racks within the electric panel, temperature sensors and the mirror connection plug. Zone alarms shut down all zones in the rack and switch the machine to manual mode; the number XX indicates the zone (01–32), the rack (01–02) or the box (01–08).

Zone parameters are set in Equipment Settings > Infrared Parameters; racks, boxes, zones and parking connectors are configured in Machine Settings > General Settings > Components, under the IR tab (configured by CEMAS).

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

M39100-0.XX - IR Rack - Communication error

What this means: Communication between the machine and the IRM module rack has failed: too many transmission errors, reception errors (response time exceeding 1.5 s) or invalid data. In the code, XX is the IR rack number (01 or 02).

Effect: Alarm. The rack zones are not being monitored and the IR heating system triggers an alarm: the machine switches from automatic to manual mode.

Probable causes:

  • the rack’s network or power cable is disconnected or damaged (IRM module connection);
  • rack not powered;
  • electrical interference.

How to resolve:

  1. Check the rack’s power supply cable and mains cable in the electric panel (electrical maintenance technician).
  2. Press Reset and check that the alarm does not reoccur.

Reset: The alarm remains stored until it is reset on the Machine Status > Alarm Monitor page.

Safety:

Warning Power modules, switches and wiring are located inside the electric panel: only open it when the machine is in a safe state, as per the user manual. This operation must be carried out by an authorised electrical maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

IRM module connection

How to identify the problem: IR rack communication alarm; no zone in the rack is responding.

Check: In the electric panel, check that the power cable and network cable for the IRM module rack are connected and undamaged.

Remedy: Reconnect or replace the damaged cable, then press Reset (electrical maintenance technician).

Warning Power modules, switches and wiring are located in the electric panel: only open it when the machine is in a safe state, as per the user manual. This operation must be carried out by an authorised electrical maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39000-0.XX - IR - Maximum card temperature reached

What this means: The IRM power module supplying the zone, located in the electric panel, signals that it has reached its maximum temperature (a threshold set within the module itself, which cannot be adjusted). Check with the zone enabled, 15 seconds after the emergency restore and with the power supply unit ready. In the code, XX is the IR zone number, ranging from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones in the rack stop and are not ready; standby and full power modes are switched off; the IR heating goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • Insufficient cooling of the electric panel: air conditioner faulty, filters blocked, doors open (Check cooling system);
  • Zone power settings set too high for prolonged periods;
  • Faulty IRM module (Replace IRM module).

How to resolve:

  1. Check that the control panel’s air conditioner is working and that doors and filters are in good condition (maintenance technician).
  2. In the advanced view of the Current values unit for the zone under Equipment settings > Infrared parameters, read the module’s temperature.
  3. Wait for the module to cool down, press Reset and check that the alarm does not reoccur.
  4. If the alarm reoccurs in the same zone whilst the lamps and cables are intact, have the IRM module replaced (CEMAS technician).

Reset: The alarm remains stored: it is cleared by pressing Reset on the Machine Status > Alarm Monitor page (or by disarming and rearming the emergency system) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the cycle.

Safety:

Warning Power modules, switches and wiring are located in the electric panel: only open it when the machine is in a safe state, as per the user manual. This operation is reserved for authorised electrical maintenance technicians.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Check the cooling system

How to recognise it: maximum temperature of the IRM modules, particularly during the hottest part of the day or when the control panel is open.

Check:

  1. Check that the electric panel’s air conditioning is working and that the filters are clean.
  2. Check that the panel doors are closed and the sockets are unobstructed.

Remedy: clean the filters or have the air conditioning unit repaired (by a maintenance technician).

Warning Power modules, switches and wiring are located inside the electric panel: only open it when the machine is safely shut down in accordance with the user manual. This work must be carried out by an authorised electrical maintenance technician.
Replace the IRM module

How to recognise it: the alarm reoccurs in the same zone after a Reset, with the power supply, control panel cooling, lamps and cables all functioning correctly.

Check: test the zone using Single Zone Test in Equipment Settings > Infrared Parameters and read the Current Values unit for the zone in Equipment Settings > Infrared Parameters.

Remedy: have the IRM module replaced (by a CEMAS technician).

Warning Power modules, switches and wiring are located in the electric panel: only open it when the machine is safely shut down in accordance with the user manual. This work must be carried out by an authorised electrical maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39200-0.XX - IR Box - Breaker triggered

What this means: The circuit breaker for the IRM module box power supply has tripped (circuit breaker input at 0). In the code, XX is the box number: 01–04 for boxes in rack 1, 05–08 for boxes in rack 2.

Effect: Alarm. The zones in the box are not receiving power: the rack signals the box alarm and the IR heating system goes into alarm mode.

Probable causes:

  • overload or fault in a box module (Circuit breaker (thermal) tripped);
  • faulty or incorrectly calibrated circuit breaker.

How to resolve:

  1. Locate the relevant box circuit breaker in the electric panel and reset it (electrical maintenance technician).
  2. If it trips again immediately, do not attempt to reset it again; have the box’s IRM modules checked (CEMAS technician).
  3. Press Reset.

Reset: The alarm clears once the circuit breaker has been reset; then press Reset on the Machine Status > Alarm Monitor page for zone alarms.

Safety:

Warning Power modules, switches and wiring are located in the electric panel: only open it when the machine is in a safe state, as per the user manual. This operation must be carried out by an authorised electrical maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Circuit breaker (thermal) has tripped

How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.

Check:

  1. Locate the component’s circuit breaker on the wiring diagram and check its position.
  2. Check that the thermal setting corresponds to the diagram.
  3. Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.

Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).

Warning Resetting and work on the electric panel must be carried out by qualified personnel, with the machine safely shut down in accordance with the user manual.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39201-0.XX - IR Box - Not ready

What this means: With the emergency mode restored, the IRM module box power supply does not signal that it is ready. In the code, XX is the box number: 01–04 for boxes in rack 1, 05–08 for boxes in rack 2.

Effect: Alarm. The zones in the box are not being powered: the rack signals the box alarm and the IR heating goes into alarm mode.

Probable causes:

  • power supply is booting up or not powered;
  • power supply faulty;
  • Ready signal wiring disconnected.

How to resolve:

  1. Wait a few seconds after the emergency restore.
  2. Check the power supply and indicator lights for the enclosure’s power supply unit in the electric panel (electrical maintenance technician).
  3. Press Reset.

Reset: The alarm clears when the power supply is ready; then press Reset on the Machine Status > Alarm Monitor page.

Safety:

Warning Power modules, switches and wiring are located in the electric panel: only open it when the machine is in a safe state, as per the user manual. This operation must be carried out by an authorised electrical maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39101-0.XX - IR Rack - Zones

What it means: Summary alert, triggered when a zone of the rack is in alarm. It does not appear in the Alarm Monitor: specific alarms appear instead. In the code, XX is the IR rack number (01 or 02).

Effect: None other than that of the specific alarms that trigger it.

How to resolve:

  1. Check the Machine Status > Alarm Monitor page for active specific alarms and follow the instructions.

Reset: Cleared by resetting the specific alarms.

Availability: Only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

M39001-0.XX - IR - Output Voltage Too High

What this means: The IRM module is sending signals that the voltage at the output to the zone’s lamps is too high (internal threshold within the module). Check with the zone enabled, 15 seconds after the emergency restore and with the power supply unit ready. In the code, XX is the IR zone number, ranging from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones in the rack stop and are not ready; standby and full power modes are switched off; the IR heating goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • zone resistance too high: lamp broken or faulty connection (Check resistance);
  • faulty IRM module.

How to resolve:

  1. Read the resistance and voltage in the Current values section for the zone under Equipment settings > Infrared parameters and compare the resistance with the Nominal and Tolerance values in the Resistance section.
  2. With the machine in a safe state and the mirror cold, check the lamps, plug and cables for the zone (maintenance technician).
  3. Press Reset and test the zone using Single Zone Test.
  4. If the alarm reoccurs in the same zone whilst the lamps and cables are intact, have the IRM module replaced (by a CEMAS technician).

Reset: The alarm remains stored: it is cleared by pressing Reset on the Machine Status > Alarm Monitor page (or by disarming and rearming the emergency system) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the cycle begins.

Safety:

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full error code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Check resistance

How to recognise it: voltage, power, load or zone resistance alarms.

Check:

  1. Read the measured resistance in the Current values unit for the zone under Tool settings > Infrared parameters.
  2. Compare it with the Nominal ± Tolerance in the Resistance unit.

Remedy: if the resistance is outside the limits, check the lamps, plug and cables (by a maintenance technician); if the Nominal value is incorrect, correct it to match the value of the installed lamps.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39002-0.XX - IR - Output Power Too High

What this means: The IRM module is sending signals that too much power is being supplied to the zone, due to excessive voltage or current (internal module threshold). Check with the zone enabled, 15 seconds after the emergency restore and with the power supply unit ready. In the code, XX is the IR zone number, ranging from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones in the rack stop and are not ready; standby and full power modes are switched off; the IR heating goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • Standby or Full power 1 settings too high for the zone’s lamps (Check power);
  • Zone resistance outside the limits (Check resistance);
  • Faulty IRM module.

How to resolve:

  1. Read the power and resistance in the Current values unit for the zone under Equipment settings > Infrared parameters.
  2. If the power is too high, reduce Standby and Full power 1 in the Power unit under Equipment settings > Infrared parameters.
  3. Press Reset and test the zone using Single Zone Test.
  4. If the alarm reoccurs on the same zone whilst the lamps and cables are intact, have the IRM module replaced (by a CEMAS technician).

Reset: The alarm remains stored: it can be cleared by selecting Reset on the Machine Status > Alarm Monitor page (or by disarming and rearming the emergency system) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the cycle begins.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the element number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Check resistance

How to recognise it: voltage, power, load or zone resistance alarms.

Check:

  1. Read the measured resistance in the Current values unit for the zone under Tool settings > Infrared parameters.
  2. Compare it with the Nominal ± Tolerance in the Resistance unit.

Remedy: if the resistance is outside the limits, check the lamps, plug and cables (by a maintenance technician); if the Nominal value is incorrect, correct it to match the value of the installed lamps.

Check power

How to identify it: high power alarm for the zone.

Check: read the power output in the Current values unit for the zone under Equipment settings > Infrared parameters and compare it with the power settings in the Power unit.

Remedy: reduce Standby and Full power 1 to values suitable for the lamps in the zone, in accordance with the validated tool values.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39102-0.XX – IR Rack – Box 1

What it means: Summary alert, activated when box 1 of the rack is in alarm. It does not appear in the Alarm Monitor: specific alarms appear instead. In the code, XX is the IR rack number (01 or 02).

Effect: None other than that of the specific alarms that trigger it.

How to resolve:

  1. Check the Machine Status > Alarm Monitor page for active specific alarms and follow the instructions.

Reset: Cleared by resetting the specific alarms.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

M39103-0.XX – IR Rack – Box 2

What it means: Summary alert, triggered when rack box 2 is in alarm. It does not appear in the Alarm Monitor: instead, the specific alarms are displayed. In the code, XX is the IR rack number (01 or 02).

Effect: None other than that of the specific alarms that trigger it.

How to resolve:

  1. Check the Machine Status > Alarm Monitor page for active specific alarms and follow the instructions.

Reset: Cleared by resetting the specific alarms.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

M39003-0.XX - IR - Input Voltage Too Low

What this means: The IRM module is signaling that the input supply voltage is too low (internal module threshold). Check with the zone enabled, 15 seconds after the emergency restore and with the power supply unit ready. In the code, XX is the IR zone number, ranging from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones in the rack stop and are not ready; standby and full power modes are switched off; the IR heating goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • power supply to the box or rack interrupted or insufficient: breaker triggered (Check IRM power supply);
  • faulty IRM module (Replace IRM module).

How to resolve:

  1. Check whether any IR Box alarms are active on the same rack and resolve those first.
  2. Check the circuit breakers and power supply to the box in the electric panel (electrical maintenance technician).
  3. Press Reset.
  4. If the alarm reoccurs in the same zone whilst the lamps and cables are intact, have the IRM module replaced (CEMAS technician).

Reset: The alarm remains stored: it can be cleared by pressing Reset on the Machine Status > Alarm Monitor page (or by disarming and rearming the emergency system) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the machine cycle.

Safety:

Warning Power modules, switches and wiring are located in the electric panel: only open it when the machine is in a safe state, as per the user manual. This operation is reserved for authorised electrical maintenance technicians.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Replace the IRM module

How to recognise it: the alarm reoccurs in the same zone after a Reset, with the power supply, control panel cooling, lamps and cables all functioning correctly.

Check: test the zone using Single Zone Test in Equipment Settings > Infrared Parameters and read the Current Values unit for the zone in Equipment Settings > Infrared Parameters.

Remedy: have the IRM module replaced (by a CEMAS technician).

Warning Power modules, switches and wiring are located in the electric panel: only open it when the machine is safely shut down in accordance with the user manual. This work must be carried out by an authorised electrical maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Check the MRI power supply

How to recognise it: low input voltage in one or more zones of the same box, often accompanied by IR Box alarms.

Check: in the electric panel, check the circuit breakers, power supply and the cabling of the box and rack supplying the module.

**Remedy: reset the circuit breaker or restore the power supply (electrical maintenance technician).

Warning Power modules, circuit breakers and wiring are located in the electric panel: only open it when the machine is in a safe state, as per the user manual. This operation must be carried out by an authorised electrical maintenance technician.

M39104-0.XX - IR Rack - Box 3

What it means: Summary alert, triggered when box 3 of the rack is in alarm. It does not appear in the Alarm Monitor: instead, the specific alarms appear. In the code, XX is the IR rack number (01 or 02).

Effect: None other than that of the specific alarms that trigger it.

How to resolve:

  1. Check the Machine Status > Alarm Monitor page for active specific alarms and follow the instructions.

Reset: Cleared by resetting the specific alarms.

Availability: Only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

M39004-0.XX - IR - Temperature Too Low

What this means: The IRM module indicates that the temperature is too low using its own error code and an internal threshold that cannot be adjusted. This is different from a zone that has not yet reached the correct temperature, which only displays the Not ready signal. Check with the zone enabled, 15 seconds after the emergency restore and with the power supply unit ready. In the code, XX is the IR zone number, ranging from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones in the rack stop and are not ready; standby and full power are switched off; the IR heating goes into alarm mode and the machine switches from automatic to manual.

Probable causes:

  • mirror or zone still cold at start-up (Wait for heating);
  • Insufficient Standby power (Adjust power);
  • Inappropriate temperature setpoint (Adjust temperature setpoint);
  • Faulty IRM module.

How to resolve:

  1. Wait a few minutes after switching on and press Reset.
  2. Check the Standby and temperature setpoint for the zone under Tool settings > Infrared parameters.
  3. If the alarm reoccurs in a single zone, have the IRM module checked (CEMAS technician).

Reset: The alarm remains stored: it can be cleared by pressing Reset on the Machine Status > Alarm Monitor page (or by disarming and rearming the emergency system) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the machine cycle begins.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the element number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with a mirror-equipped tool (Tool type other than Without mirror in Tool settings > Configuration).

Waiting for the heating to come on

How to recognise it: the alarm appears shortly after switching on or a tool change.

Check: check the current temperature of the zone in Tool Settings > Infrared Parameters: it should rise towards the temperature setpoint.

Remedy: wait for the mirror to reach the correct temperature, then press Reset.

Change power

How to recognise it: the zone’s temperature rises slowly and does not reach the setpoint.

Check: compare the zone’s Standby power in the Power unit under Equipment settings > Infrared parameters with that of similar zones.

Remedy: gradually increase the Standby setting, without exceeding the tools’ validated values.

Change temperature setpoint

How to recognise it: the zone remains below the setpoint even though the power is adequate.

Check: check the Temperature setpoint and Tolerance in the Temperature sensor unit under Tool settings > Infrared parameters.

Remedy: reset the setpoint to the tools’ validated values.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39005-0.XX - IR - Heater faulty

What this means: The IRM module is signaling a load fault: the lamps in the zone are not drawing the expected current. Check with the zone enabled, 15 seconds after the emergency restore has taken place and with the power supply unit ready. In the code, XX is the IR zone number, ranging from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones of the rack stop and are not ready; standby and full power modes are switched off; the IR heating system goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • lamp cut off (Check lamps);
  • plug, cables or connections between the module and the mirror are disconnected (Check IRM wiring);
  • zone resistance is out of range (Check resistance).

How to resolve:

  1. Read the current and resistance in the Current values unit for the zone under Equipment settings > Infrared parameters: zero current or very high resistance indicates an open circuit.
  2. With the machine in a safe state and the mirror cold, check the plug, cables and lamps for the zone (maintenance technician).
  3. Replace the faulty lamp, press Reset and try the Single Zone Test.

Reset: The alarm remains stored: it can be cleared by pressing Reset on the Machine Status > Alarm Monitor page (or by disabling and re-enabling the emergency stop) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the machine cycle begins.

Safety:

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full error code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Check the IRM wiring

How to recognise it: abnormal load or invalid sensor, often following a tool change.

Check: with the mirror cold, check that the cables and plug between the IRM module and the mirror are intact and properly connected.

Remedy: Reconnect or replace damaged cables and connectors (by a maintenance technician).

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation is reserved for authorised maintenance technicians.
Check resistance

How to recognise it: voltage, power, load or zone resistance alarms.

Check:

  1. Read the measured resistance in the Current values unit for the zone under Tool settings > Infrared parameters.
  2. Compare it with the Nominal ± Tolerance in the Resistance unit.

Remedy: if the resistance is outside the limits, check the lamps, plug and cables (by a maintenance technician); if the Nominal value is incorrect, correct it to match the value of the installed lamps.

Check the bulbs

How to identify it: resistance in the upper zone or no current in the Current values unit under Tool settings > Infrared parameters.

Check: with the mirror cold, check that the lamps in the zone are not burnt out, blackened or broken.

Remedy: replace faulty lamps with lamps of the same type (by a maintenance technician).

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation is reserved for authorised maintenance technicians.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39105-0.XX – IR Rack – Box 4

What it means: Summary alert, triggered when box 4 of the rack is in alarm. It does not appear in the Alarm Monitor: instead, the specific alarms appear. In the code, XX is the IR rack number (01 or 02).

Effect: None other than that of the specific alarms that trigger it.

How to resolve:

  1. Check the Machine Status > Alarm Monitor page for active specific alarms and follow the instructions.

Reset: Cleared by resetting the specific alarms.

Availability: Only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

M39006-0.XX - IR - Output short-circuited

What this means: The IRM module detects a short circuit on the output to the zone. Check with the zone enabled, 15 seconds after the emergency restore and with the power supply unit ready. In the code, XX is the IR zone number, ranging from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones in the rack stop and are not ready; standby and full power modes are switched off; the IR heating goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • short circuit in cables, plug or mirror (Check for short circuits);
  • damaged lamp or faulty insulation.

How to resolve:

  1. With the machine in a safe state and the mirror cold, check the cables, plug and lamps in the zone (electrical maintenance technician).
  2. After the repair, read the resistance in the Current values unit under Equipment settings > Infrared parameters: it must be within the specified limits.
  3. Press Reset and try running a Single-zone test.

Reset: The alarm remains stored: it is cleared by pressing Reset on the Machine Status > Alarm Monitor page (or by disarming and rearming the emergency system) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the machine cycle.

Safety:

Warning Lamps, the mirror and the plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation is restricted to authorised maintenance technicians.
Warning Power modules, switches and wiring are located in the electric panel: only open it once the machines have been secured in accordance with the user manual. This operation is restricted to authorised electrical maintenance technicians.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full error code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Check for short circuits

How to identify it: short-circuit or low-zone output resistance alarm.

Check: with the mirror cold and the machine in a safe state, check that the cables, plug and lamps do not have damaged insulation or are not touching one another.

Remedy: repair or replace the damaged parts (by a qualified maintenance technician).

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This work must be carried out by an authorised maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39007-0.XX - IR - Resistance too high

What this means: 10 seconds after switching on, the measured resistance of the zone exceeds the Nominal value plus the Tolerance of the Resistance unit (Tool settings > Infrared parameters). With Nominal set to 0, the alarm is triggered for any zone that is switched on. Check with the zone enabled, 15 seconds after the emergency restore and with the power supply unit ready. In the code, XX is the IR zone number, from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones of the rack stop and are not ready; standby and full power modes are switched off; the IR heating goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • lamp cut off (Check lamps, Replace resistor);
  • faulty plug or cable connection;
  • incorrect Rated value or set to 0 (Check resistor).

How to resolve:

  1. Compare the resistance in the Current values section for the unit under Equipment settings > Infrared parameters with the Nominal value and Tolerance.
  2. If the Nominal value is 0 or incorrect, set the correct value for the lamps in the unit.
  3. Otherwise, with the mirror cold, check the lamps, plug and cables, and replace any burnt-out lamps (by a maintenance technician).
  4. Press Reset and try the Single Zone Test.

Reset: The alarm remains stored: it is cleared by pressing Reset on the Machine Status > Alarm Monitor page (or by disarming and rearming the emergency system) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the machine cycle begins.

Safety:

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full error code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Check resistance

How to recognise it: voltage, power, load or zone resistance alarms.

Check:

  1. Read the measured resistance in the Current values unit for the zone under Tool settings > Infrared parameters.
  2. Compare it with the Nominal ± Tolerance in the Resistance unit.

Remedy: if the resistance is outside the limits, check the lamps, plug and cables (by a maintenance technician); if the Nominal value is incorrect, correct it to match the value of the installed lamps.

Check the bulbs

How to identify it: resistance in the upper zone or no current in the Current values unit under Tool settings > Infrared parameters.

Check: with the mirror cold, check that the lamps in the zone are not burnt out, blackened or broken.

Remedy: replace faulty lamps with lamps of the same type (by a maintenance technician).

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation is reserved for authorised maintenance technicians.
Replace the heating element

How to identify it: the resistance in the zone remains outside the specified limits, even though the cables and plug are intact.

Check: with the lamp switched off, identify the blown or incorrect lamp (resistor).

Remedy: replace it with a bulb of the same type and check the resistance in the Current Values unit under Equipment Settings > Infrared Parameters (maintenance technician).

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation is reserved for authorised maintenance technicians.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39008-0.XX - IR - Resistance too low

What this means: 10 seconds after power-up, the measured resistance of the zone is lower than the Nominal value minus the Tolerance of the Resistance unit (Tool settings > Infrared parameters). Check with the zone enabled, 15 seconds after the emergency restore and with the power supply unit ready. In the code, XX is the IR zone number, from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones of the rack stop and are not ready; standby and full power modes are switched off; the IR heating goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • partial short circuit in cables, plug or reflector (Check for short circuits);
  • incorrect lamp type (Replace heating element);
  • incorrect rating (Check heating element).

How to resolve:

  1. Compare the resistance in the Current values unit under Tool settings > Infrared parameters with the Rated value and Tolerance.
  2. If the Nominal value is incorrect, correct it.
  3. Otherwise, with the mirror cold, check the cables, plug and lamps (maintenance technician).
  4. Press Reset and try the Single zone test.

Reset: The alarm remains stored: it is cleared by pressing Reset on the Machine Status > Alarm Monitor page (or by disengaging and re-engaging the emergency stop) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the machine cycle.

Safety:

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full error code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Check resistance

How to recognise it: voltage, power, load or zone resistance alarms.

Check:

  1. Read the measured resistance in the Current values unit for the zone under Tool settings > Infrared parameters.
  2. Compare it with the Nominal ± Tolerance in the Resistance unit.

Remedy: if the resistance is outside the limits, check the lamps, plug and cables (by a maintenance technician); if the Nominal value is incorrect, correct it to match the value of the installed lamps.

Check for short circuits

How to identify it: short-circuit or low-zone output resistance alarm.

Check: with the mirror cold and the machine in a safe state, check that the cables, plug and lamps do not have damaged insulation or are not touching one another.

Remedy: repair or replace the damaged parts (by a qualified maintenance technician).

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This work must be carried out by an authorised maintenance technician.
Replace the heating element

How to identify it: the resistance in the zone remains outside the specified limits, even though the cables and plug are intact.

Check: with the lamp switched off, identify the blown or incorrect lamp (resistor).

Remedy: replace it with a bulb of the same type and check the resistance in the Current Values unit under Equipment Settings > Infrared Parameters (maintenance technician).

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation is reserved for authorised maintenance technicians.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39009-0.XX - IR - Temperature too high

What this means: The temperature sensor associated with the zone is measuring a temperature higher than the Maximum set in the Temperature sensor unit (Equipment settings > Infrared parameters). Check with the sensor configured and the mirror in place. In the code, XX is the IR zone number, from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Warning. Alert only: the zone does not switch off, but in standby mode the setting drops to Standby power.

Possible causes:

  • Standby or Full power 1 settings too high;
  • Maximum set too low;
  • sensor displaced or close to a lamp.

How to resolve:

  1. Compare the current temperature with the Temperature setpoint and Maximum in Tool settings > Infrared parameters.
  2. Reduce the power settings or adjust the Maximum according to the tool’s validated values.
  3. When the mirror is cold, check the sensor position (maintenance technician).

Reset: The alarm remains stored; it can be cleared using Reset on the Machine Status > Alarm Monitor page once the temperature has returned to normal.

Safety:

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full error code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39010-0.XX - IR - Not ready

What this means: The zone is not automatically ready: the measured temperature is below the temperature setpoint minus the tolerance (Equipment settings > Infrared parameters). In the code, XX is the IR zone number, from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Info. Information only: the zone continues to heat. On cam-controlled IR vibration machines, the cycle does not start until the zones are ready; on IR machines, the cycle does not wait for this condition.

Possible causes:

  • mirror heating up after switch-on or a tool change;
  • Insufficient Standby power to reach the setpoint;
  • Temperature sensor displaced or faulty.

How to resolve:

  1. Wait for the zone to reach the temperature: on the screen, the current temperature will turn green.
  2. If it does not reach the temperature, check Standby and Temperature setpoint under Equipment settings > Infrared parameters.
  3. Check for any alarms relating to the same zone or its sensor.

Reset: The alert disappears automatically once the zone is ready.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the element number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with a mirrored tool (Tool type other than Without mirror in Tool settings > Configuration).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39011-0.XX - IR - Analogue temperature sensor

What this means: The signal from the temperature sensor (thermocouple) associated with the zone is invalid. Continuous monitoring with the configured sensor. In the code, XX is the IR zone number, ranging from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones in the rack stop and are not ready; standby and full power modes are switched off; the IR heating goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • damaged or disconnected thermocouple (Damaged thermocouple);
  • faulty mirror plug contacts (Check mirror plug wiring);
  • damaged cables between the module and the mirror (Check IRM wiring).

How to resolve:

  1. Under Equipment Settings > Infrared Parameters, in the Temperature Sensor unit, check which sensor is associated with the zone.
  2. With the mirror cold, check the thermocouple, plug and cables (maintenance technician).
  3. Press Reset.

Reset: The alarm clears when the signals return to normal; then press Reset on the Machine Status > Alarm Monitor page.

Safety:

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation is reserved for authorised maintenance technicians.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full error code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Damaged thermocouple

How to identify it: invalid temperature sensor alarm; the temperature in the zone is implausible.

Check: on the cold mirror, check that the thermocouple on the mirror is intact, securely fixed and connected.

Remedy: Reconnect or replace the thermocouple (by a maintenance technician).

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation must be carried out by an authorised maintenance technician.
Check the wiring for the mirror plug

How to recognise it: intermittent sensor or load errors that change when the plug is moved.

Check: with the mirror switched off, check that the contacts on the mirror’s plug are intact, clean and not deformed.

Remedy: clean or replace the plug (by a maintenance technician).

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation must be carried out by an authorised maintenance technician.
Check the IRM wiring

How to recognise it: abnormal load or invalid sensor, often following a tool change.

Check: with the mirror cold, check that the cables and plug between the IRM module and the mirror are intact and properly connected.

Remedy: Reconnect or replace damaged cables and connectors (by a maintenance technician).

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation is reserved for authorised maintenance technicians.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39012-0.XX - IR - Connector not in parking position

What this means: The mirror connection plug is not in the parking position when it should be: either when the tools are without a mirror, or when the plug’s zones are not enabled. Each plug supplies power to two zones (plug 1: zones 1 and 2, plug 2: zones 3 and 4, and so on). Check that this is not the case after a tool change, with the emergency mode reset. In the code, XX is the IR zone number, from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. The rack zones stop and the IR heating is not ready; on cam-driven IR vibration machines, the horizontal movement of the mirror is blocked.

Probable causes:

  • plug not returned to the parking position after a tool change (Plug in parking position);
  • tools or zones configured incorrectly;
  • faulty parking sensor.

How to resolve:

  1. Insert the mirror plug into the parking socket at the rear of the welding machine.
  2. Check the Tool type and enabled zones in Tool settings > Infrared parameters.
  3. If the plug is in the socket and the alarm persists, have the sensor checked (by a maintenance technician).

Reset: The alarm clears automatically once the condition is rectified.

Safety:

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation is reserved for authorised maintenance technicians.

The parking connectors are enabled in Machine Settings > General Settings > Components, IR tab (configured by CEMAS).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full error code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Plug in the car park

How to recognise it: ‘Connector not in dock’ alarm, when using tools without a mirror or with unused sections of the plug.

Check: check that the mirror plug is inserted into the dock at the rear of the welding machine.

Remedy: Insert the plug into the socket (operator).

Warning The lamps, mirror and plug remain very hot even after the machine has been switched off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation is reserved for authorised maintenance technicians.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39013-0.XX - IR - Parking connector

What this means: The mirror connection plug is in the parking position, but the fitted tools have the mirror and are using the zones associated with that plug. Check outside the tool change, with the emergency mode reset. In the code, XX is the IR zone number, from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. The rack zones stop and the IR heating is not ready; on cam-driven IR vibration machines, the horizontal movement of the mirror is blocked.

Probable causes:

  • plug not connected to the mirror after a tool change (Connect plug);
  • faulty parking sensor.

How to resolve:

  1. Remove the plug from the parking position and insert it into the mirror socket.
  2. If the plug is connected and the warning remains, have the parking sensor checked (by a maintenance technician).

Reset: The warning clears automatically once the plug is connected.

Safety:

Warning The lamps, mirror and plug remain very hot even after switching off: before touching them, secure the machine in accordance with the user manual, wait for them to cool down and wear heat-resistant gloves. This operation must be carried out by an authorised maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full error code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Plug in the plug

How to recognise it: parking socket warning light, with a mirror-mounted tool fitted.

Check: check that the plug is connected to the mirror socket and not in the parking socket.

Remedy: remove the plug from the parking socket and insert it into the mirror socket (operator).

Warning The lamps, mirror and plug remain very hot even after switching off: before touching them, secure the machine in accordance with the user manual, wait for it to cool down and wear heat-resistant gloves. This operation is reserved for authorised maintenance technicians.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M39014-0.XX - IR - Communication with the PLC

What this means: The IRM module for the zone is reporting a communication error with the machine. Check with the zone enabled, 15 seconds after the emergency restore and with the power supply unit ready. In the code, XX is the IR zone number, ranging from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones of the rack stop and are not ready; standby and full power modes are switched off; the IR heating goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • the module’s mains cable is disconnected or damaged;
  • the module is not powered or is faulty.

How to resolve:

  1. Check whether the same alarm is active across multiple zones of the same rack: if so, check the rack’s connections.
  2. Check the module’s connection and power supply in the electric panel (electrical maintenance technician).
  3. Press Reset.
  4. If the alarm reoccurs in the same zone whilst the lamps and cables are intact, have the IRM module replaced (CEMAS technician).

Reset: The alarm remains stored: it can be cleared by pressing Reset on the Machine Status > Alarm Monitor page (or by disarming and rearming the emergency system) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the cycle.

Safety:

Warning Power modules, switches and wiring are located in the electric panel: only open it when the machine is in a safe state, as per the user manual. This operation must be carried out by an authorised electrical maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the component number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

M39015-0.XX - IR - Low current requirement

What this means: The IRM module signals that the current required for the zone is below its minimum operating level. Check with the zone enabled, 15 seconds after the emergency restore and with the power supply unit ready. In the code, XX is the IR zone number, ranging from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones in the rack stop and are not ready; standby and full power modes are switched off; the IR heating system goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • power setting for the zone is too low;
  • the zone’s resistance is significantly different from expected.

How to resolve:

  1. Check the zone power settings in the Power unit Equipment Settings > Infrared Parameters.
  2. Compare the resistance in the Current Values unit for the zone under Equipment Settings > Infrared Parameters with Nominal and Tolerance.
  3. Press Reset.

Reset: The alarm remains stored: it is cleared by pressing Reset on the Machine status > Alarm monitor page (or by disarming and rearming the emergency system) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the cycle.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the element number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

M39016-0.XX - IR - High current demand

What this means: The IRM module signals that the current required for the zone exceeds its maximum operating current. Check with the zone enabled, 15 seconds after the emergency restore and with the power supply unit ready. In the code, XX is the IR zone number, ranging from 01 to 32 (rack 1: zones 01–16, rack 2: zones 17–32).

Effect: Alarm. All 16 zones in the rack stop and are not ready; standby and full power modes are switched off; the IR heating system goes into alarm mode and the machine switches from automatic to manual mode.

Probable causes:

  • power setting too high for the zone’s lamps;
  • zones resistance set too low.

How to resolve:

  1. Check the zone power settings in the Power unit of Equipment Settings > Infrared Parameters.
  2. Compare the resistance in the Current Values unit for the zone under Equipment Settings > Infrared Parameters with the Nominal and Tolerance values.
  3. Press Reset.

Reset: The alarm remains stored: it is cleared by pressing Reset on the Machine status > Alarm monitor page (or by disarming and rearming the emergency system) after the cause has been rectified; the zones will restart and must be brought back up to temperature before the cycle.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the element number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

M39202-0.XX - IR Box - Starting up

What this means: The IRM module box is checked within the first 15 seconds of boot-up. Fixed time. In the code, XX is the box number: 01–04 for boxes in rack 1, 05–08 for boxes in rack 2.

Effect: Info. Information only: the zones in the box are not monitored until boot-up is complete.

How to resolve:

  1. Wait 15 seconds.

Reset: The message clears automatically once the start-up is complete.

If the problem persists: if the message remains active, check the other alarms in the unit; then contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code including the element number, model and serial number, the time of the alarm (Machine Status > Alarm Monitor, Alarm History tab) and the checks carried out.

Availability: only on machines with infrared heating: IR (IR9, IR14, IR20) and cam-driven IR vibration (911MK2-IR, 918MK2-IR). Tool option: with mirrored tools (Tool type other than Without mirror in Tool settings > Configuration).

Voltage monitoring

Alarms relating to the voltage monitoring of the machine’s circuits (up to ten). The status can be viewed under Machine Diagnostics > PLC, on the Card Monitoring tab, in the Voltage Presences section; it can be configured under Machine Settings > General Settings > Components, on the Voltage Presences tab.

M44000-0.XX – Voltage control – Not fitted

What this means: a monitored supply voltage is not present (signal from an input or from a channel on a selective module). The status can be viewed under Machine Diagnostics > PLC, on the Card Monitoring tab, in the Voltage Presences section: grey indicator light = no voltage. In the code, XX is the number of the monitored voltage (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. With some configurations, input diagnostics are suspended until the voltage returns.

Probable causes:

  • open circuit switch or fuse (Inspect the electric panel);
  • selective module channel tripped;
  • faulty power supply.

How to resolve:

  1. Identify the circuit with the grey indicator light.
  2. Check the circuit’s switches, fuses and selective modules in the control panel (maintenance technician).
  3. Reset and check that the indicator light turns green.

Reset: once the cause has been rectified, press Reset on the Alarm Monitor.

Safety:

Warning Before opening the electric panel, secure the machines in accordance with the user manual. This operation is reserved for qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if voltage monitoring is present (Machine settings > General settings > Components, Voltage presences tab), an option configured by CEMAS.

Inspection of the electric panel

How to identify this: in Machine Diagnostics > PLC, on the Card Monitoring tab, in the Voltage Presences section, the indicator light for a circuit is grey.

Check:

  1. Identify the circuit that has tripped.
  2. Check the circuit breakers, fuses and selective module channels for that circuit in the switchboard.

Remedy: eliminate the cause of the trip and reset (maintenance technician).

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation must only be carried out by qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Protective Gear for Tools

Alarms relating to the mirror’s tool guards, the cycle-controlled and manually operated guards accessed via Machine Diagnostics > Manual Movements, Machine tab > Guards: incomplete movements, inconsistent sensors, simultaneous commands.

Guards are configured in Machine Settings > General Settings > Tool Interfaces, Spindle tab, Guards tab.

Availability: only on IR machines (IR9, IR14, IR20), HP machines with hot plates (HP9, HP14, HP20, HP-P125) and IR 912-IR vibration machines. Machine option: appears if safety guards are fitted; option configured via CEMAS.

M45000-3.XX - Mirror (rear/left) - Tool Protectors - Timeout in rest position

What this means: Following the command to move to the rest position, the sensor for that position of the mirror safety device did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Safety Devices tab (−1 disables the check). The guards are automatically controlled by the cycle.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • rest position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement from Machine Diagnostics > Manual Movements, Machine tab > Safeguards (Operating, Rest): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is simply slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on IR machines (IR9, IR14, IR20), HP machines with hot plates (HP9, HP14, HP20, HP-P125) and IR 912-IR vibration machines. Machine option: appears if the safety guards are fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Move not completed

How to identify the problem: the guard does not move to the commanded position, or it moves there but the sensor does not light up.

Check:

  1. Initiate the movement from Machine Diagnostics > Manual Movements, Machine tab > Guards (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor’s LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the safety device completes the movement, but with a delay relative to the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, Protections tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M45001-3.XX - Mirror (rear/left) - Tools Protective Fittings - Work position timeout

What this means: Following the command to move to the working position, the sensor for that position of the mirror guard did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Guards tab (−1 disables the check). The guards are automatically controlled by the cycle.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • movement obstructed by a mechanical obstruction;
  • insufficient air pressure or a valve that fails to switch;
  • work position sensor out of calibration or faulty.

How to resolve:

  1. Initiate the movement from Machine Diagnostics > Manual Movements, Machine tab > Safeguards (Work, Rest): if this does not occur, check for obstructions and verify the air supply and valve (maintenance technician).
  2. If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
  3. If the movement is merely slow, have the Time-out checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on IR machines (IR9, IR14, IR20), HP machines with hot plates (HP9, HP14, HP20, HP-P125) and IR 912-IR vibration machines. Machine option: appears if the safety guards are fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Check the compressed air

How to identify the problem: the guard does not move into the working position or moves slowly.

Check:

  1. Check the supply air pressure to the safety guard.
  2. Activate the safety guard and check that the valve switches (coil LED lit).

Remedy: restore the air supply, replace the faulty valve or solenoid (by a maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Move not completed

How to identify the problem: the guard does not move to the commanded position, or it moves there but the sensor does not light up.

Check:

  1. Initiate the movement from Machine Diagnostics > Manual Movements, Machine tab > Guards (Work, Rest) and observe whether the stroke is completed.
  2. Stroke complete: check the sensor’s LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
  3. Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.

Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Not enough time

How to recognise it: the safety device completes the movement, but with a delay relative to the Time out: the alarm is triggered even if the position is subsequently reached.

Check:

  1. Manually control the movement and measure how long it takes to reach the position.
  2. Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, Protections tab.

Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M45002-3.XX - Mirror (rear/left) - Tools Protectors - Rest position not released

What this means: After the command to move to the working position, when the Time out expires, the sensor for the mirror guard’s rest position is still active: the device has not started, or the sensor remains on.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • rest position sensor constantly active or out of calibration.

How to resolve:

  1. Initiate the movement via Machine Diagnostics > Manual Movements, Machine tab > Safeguards (Work, Rest), whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the rest position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before carrying out any work on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on IR machines (IR9, IR14, IR20), HP machines with hot plates (HP9, HP14, HP20, HP-P125) and IR 912-IR vibration machines. Machine option: appears if the safety devices are fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Tool guards locked in place

How to identify the problem: the safety guard does not start when commanded or stops halfway through its movement; the position sensor remains lit.

Check:

  1. Initiate the movement from Machine Diagnostics > Manual Movements, Machine tab > Safeguards (Work, Standby), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the travel (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M45003-3.XX – Mirror (rear/left) – Tool guards – Work position not released

What this means: Following the command to return to the rest position, once the Time-out has elapsed, the mirror guard’s working position sensor is still active: the device has not started, or the sensor remains on.

Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding process results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device mechanically jammed;
  • no air supply or valve failing to switch;
  • working position sensor constantly active or out of calibration.

How to resolve:

  1. Control the movement via Machine Diagnostics > Manual Movements, Machine tab > Safeguards (Work, Standby), whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
  2. If the device moves but the work position sensor LED remains lit, adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before carrying out any work on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on IR machines (IR9, IR14, IR20), HP hot plate machines (HP9, HP14, HP20, HP-P125) and IR 912-IR vibration machines. Machine option: appears if the safety devices are fitted; option configured by CEMAS.

Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Tool guards locked in place

How to identify the problem: the safety guard does not start when commanded or stops halfway through its movement; the position sensor remains lit.

Check:

  1. Initiate the movement from Machine Diagnostics > Manual Movements, Machine tab > Safeguards (Work, Standby), whilst observing the device.
  2. With the machine in a safe state, check that nothing is obstructing the travel (residue, loose components).

Remedy: remove the obstruction and check the air supply and valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M45004-3.XX - Mirror (rear/left) - Tool Protectors - External Alarm

What this means: A message is provided for an external alarm relating to the mirror tool’s safety devices. In current versions of the machine software, the message is provided but is not triggered.

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on IR machines (IR9, IR14, IR20), HP machines with hot plates (HP9, HP14, HP20, HP-P125) and IR 912-IR vibration machines. Machine option: appears if the safety guards are fitted; option configured by CEMAS.

M45005-3.XX - Mirror (rear/left) - Tool Protectors - Both position indicators

What this means: The sensors for the mirror guard’s rest and working positions are active simultaneously: the position cannot be determined. Monitoring is always active when the device is present.

Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a faulty or short-circuited sensor that is always active;
  • sensors positioned so that they detect both positions;
  • sensor inputs configured incorrectly.

How to resolve:

  1. With the device stopped, check under Machine Diagnostics > PLC, on the Card Monitoring tab, which of the two inputs is active for no reason.
  2. Operate the device via Machine Diagnostics > Manual Movements, under the Machine tab > Safeguards (Work, Rest): each sensor should only light up in its own position; reposition or replace the one that remains lit (maintenance technician).
  3. If the sensors are working, have the inputs checked in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Protections tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on IR machines (IR9, IR14, IR20), HP machines with hot plates (HP9, HP14, HP20, HP-P125) and IR 912-IR vibration machines. Machine option: appears if the safety guards are fitted; option configured by CEMAS.

Sensor positioning

How to identify this: the component’s two position sensors are active at the same time.

Check:

  1. Move the component to one position and check that only the LED for the corresponding sensor is lit.
  2. Repeat in the other position.
  3. Check that each sensor is securely fitted and detects only its own position.

Remedy: reposition or replace the sensor that remains active (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M45006-3.XX - Mirror (rear/left) - Tool Protectors - Both Commands

What this means: The two motion valves for the mirror protection are being actuated simultaneously: either due to a manual command issued during a cycle, or because the outputs have been configured incorrectly.

Effect: Alarm (red line): the valves de-energise and the device stops; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • a manual command issued at the same time as a cycle command;
  • the same output assigned to both movements.

How to resolve:

  1. Press Reset and repeat the movement using only one command at a time.
  2. If the alarm reoccurs, have the valve outputs checked in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Protections tab (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

Availability: only on IR machines (IR9, IR14, IR20), HP machines with hot plates (HP9, HP14, HP20, HP-P125) and IR 912-IR vibration machines. Machine option: appears if the safety guards are fitted; option configured by CEMAS.

Reset the controls

How to recognise it: the component receives the two opposing commands simultaneously (for example, forwards and backwards).

Check:

  1. Check the outputs and commands assigned to the component under Machine Settings > General Settings > Tool Interfaces.
  2. Check that two different commands do not use the same output or the same signal.

Remedy: correct the configuration (CEMAS technician).

Prohibited The **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Air interface

Alarms for the air interface, the valve that supplies compressed air to the tools on the head, table or mirror when the tools are present and connected, controlled by a pressure switch and, where fitted, by two safety inputs.

The air interface is configured under Machine Settings > General Settings > Tool Interfaces, in the zone tab, under the Air Valve tab.

M46000-1.XX - Head - Air interface - Pressure switch

What this means: With the head air interface open, the pressure switch does not confirm that the pressure is within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Head tab, Air Valve tab (typically 5 seconds, s). The interface is opened whilst the tools are in place, the tool safety devices are secure, there are no alarms and the pneumatic connector is inserted (if fitted). The alarm is logged.

Effect: Alarm (red line): the interface valve closes; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • insufficient compressed air;
  • interface valve fails to switch or solenoid coil is not energised;
  • pressure switch out of calibration or faulty.

How to resolve:

  1. Check the supply air pressure (maintenance technician).
  2. Check that the valve switches (coil LED lit) and that the pressure switch input is activated in Machine Diagnostics > PLC, under the Card Monitoring tab.
  3. Adjust or replace the pressure switch or the valve (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machines in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the air interface is enabled, an option configured by CEMAS.

Pressure switch adjustment

How to recognise this: air is reaching the tool but the interface pressure switch is not confirming the pressure.

Check:

  1. Read the pressure using the system pressure gauge.
  2. Check that the pressure switch is set to 5 bar and that its input is active in Machine Diagnostics > PLC, under the Card Monitoring tab.

Remedy: adjust or replace the pressure switch (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Controlled electric coil

How to identify the fault: the air supply valve does not open: no pressure reaches the downstream side even when mains air is present.

Check:

  1. Check that the PLC is controlling the valve (output active in Machine Diagnostics > PLC, Card Monitoring tab).
  2. Check the LED on the solenoid connector for the controlled valve.
  3. Check the voltage across the solenoid and the wiring.

Remedy: replace the connector or solenoid; if the solenoid is energised but the valve does not open, replace the valve (by a maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance by a qualified maintenance technician.
Warning Resetting and measurements in the electric panel must be carried out by qualified personnel, with the machine secured in accordance with the user manual.
Valve function

How to identify the problem: when the interface is open, air does not reach the tools.

Check:

  1. Check that the valve coil is receiving a signal (LED lit).
  2. Check that the valve switches and that there is pressure downstream.

Remedy: replace the faulty valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M46000-2.XX – Table – Air interface – Pressure switch

What this means: With the table’s air interface open, the pressure switch does not confirm that the pressure is within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Air Valve tab (typically 5 seconds, s). The interface is opened whilst the tools are in place, the tool safety devices are engaged, there are no alarms and the pneumatic connector is inserted (if fitted). The alarm is logged.

Effect: Alarm (red line): the interface valve closes; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • insufficient compressed air;
  • interface valve fails to switch or solenoid coil is not energised;
  • pressure switch out of calibration or faulty.

How to resolve:

  1. Check the supply air pressure (maintenance technician).
  2. Check that the valve switches (coil LED lit) and that the pressure switch input is activated in Machine Diagnostics > PLC, under the Card Monitoring tab.
  3. Adjust or replace the pressure switch or the valve (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the air interface is enabled; this option is configured by CEMAS.

Pressure switch adjustment

How to recognise this: air is reaching the tool but the interface pressure switch is not confirming the pressure.

Check:

  1. Read the pressure using the system pressure gauge.
  2. Check that the pressure switch is set to 5 bar and that its input is active in Machine Diagnostics > PLC, under the Card Monitoring tab.

Remedy: adjust or replace the pressure switch (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Controlled electric coil

How to identify the fault: the air supply valve does not open: no pressure reaches the downstream side even when mains air is present.

Check:

  1. Check that the PLC is controlling the valve (output active in Machine Diagnostics > PLC, Card Monitoring tab).
  2. Check the LED on the solenoid connector for the controlled valve.
  3. Check the voltage across the solenoid and the wiring.

Remedy: replace the connector or solenoid; if the solenoid is energised but the valve does not open, replace the valve (by a maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance by a qualified maintenance technician.
Warning Resetting and measurements in the electric panel must be carried out by qualified personnel, with the machine secured in accordance with the user manual.
Valve function

How to identify the problem: when the interface is open, air does not reach the tools.

Check:

  1. Check that the valve coil is receiving a signal (LED lit).
  2. Check that the valve switches and that there is pressure downstream.

Remedy: replace the faulty valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M46000-3.XX – Mirror (rear/left) – Air interface – Pressure switch

What this means: With the air interface of the spindle open, the pressure switch does not confirm the pressure within the Time-out set in Machine Settings > General Settings > Tool Interfaces, Spindle tab, Air Valve tab (typically 5 seconds, s). The interface is opened whilst the tools are in place, the tool safety devices are engaged, there are no alarms and the pneumatic connector is inserted (if fitted). The alarm remains stored.

Effect: Alarm (red line): the interface valve closes; indication only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • insufficient compressed air;
  • interface valve fails to switch or solenoid coil is not energised;
  • pressure switch out of calibration or faulty.

How to resolve:

  1. Check the supply air pressure (maintenance technician).
  2. Check that the valve switches (coil LED lit) and that the pressure switch input is activated in Machine Diagnostics > PLC, under the Card Monitoring tab.
  3. Adjust or replace the pressure switch or the valve (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types of blade: IR (IR9, IR14, IR20), hot plate blade (HP9, HP14, HP20, HP-P125), IR 912-IR vibration blade and IR cam vibration blade (911MK2-IR, 918MK2-IR). Machine option: appears if the air interface is enabled; this option is configured via CEMAS.

Pressure switch adjustment

How to recognise this: air is reaching the tool but the interface pressure switch is not confirming the pressure.

Check:

  1. Read the pressure using the system pressure gauge.
  2. Check that the pressure switch is set to 5 bar and that its input is active in Machine Diagnostics > PLC, under the Card Monitoring tab.

Remedy: adjust or replace the pressure switch (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
Controlled electric coil

How to identify the fault: the air supply valve does not open: no pressure reaches the downstream side even when mains air is present.

Check:

  1. Check that the PLC is controlling the valve (output active in Machine Diagnostics > PLC, Card Monitoring tab).
  2. Check the LED on the solenoid connector for the controlled valve.
  3. Check the voltage across the solenoid and the wiring.

Remedy: replace the connector or solenoid; if the solenoid is energised but the valve does not open, replace the valve (by a maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance by a qualified maintenance technician.
Warning Resetting and measurements in the electric panel must be carried out by qualified personnel, with the machine secured in accordance with the user manual.
Valve function

How to identify the problem: when the interface is open, air does not reach the tools.

Check:

  1. Check that the valve coil is receiving a signal (LED lit).
  2. Check that the valve switches and that there is pressure downstream.

Remedy: replace the faulty valve (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M46001-3.XX - Mirror (rear/left) - Air interface - Safety inputs not present

What this means: The two safety inputs on the mirror’s air interface remain out of sync for more than 500 milliseconds (ms). Checked with the safety inputs configured in Machine Settings > General Settings > Tool Interfaces, Mirror tab, Air Valve tab and the tool safety devices in place; this setting is saved.

Effect: Alarm (red line): the interface valve closes; indication only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • one of the two safety sensors is faulty, out of calibration or disconnected;
  • unstable pressure.

How to resolve:

  1. Check the two safety inputs in Machine Diagnostics > PLC, under the Card Monitoring tab: they must change state simultaneously.
  2. Check the wiring and calibration of the sensor that is lagging behind; replace it if faulty (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the following types of blade: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration blade and IR cam-type vibration blade (911MK2-IR, 918MK2-IR). Machine option: appears if the air interface is enabled; this option is configured via CEMAS.

M46001-1.XX – Head – Air interface – Safety inputs not present

What this means: The two safety inputs on the head’s air interface remain out of sync for more than 500 milliseconds (ms). Checked with the safety inputs configured in Machine Settings > General Settings > Tool Interfaces, Head tab, Air Valve tab and the tool safety devices in place; this setting is saved.

Effect: Alarm (red line): the interface valve closes; the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • one of the two safety sensors is faulty, out of calibration or disconnected;
  • unstable pressure.

How to resolve:

  1. Check the two safety inputs in Machine Diagnostics > PLC, under the Card Monitoring tab: they must change state simultaneously.
  2. Check the wiring and calibration of the sensor that is lagging behind; replace it if faulty (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with the tools also fitted to the head: laser, IR and HP hot plate. Machine option: appears if the air interface is enabled; this option is configured by CEMAS.

M46001-2.XX - Table - Air interface - Safety inputs not present

What this means: The two safety inputs on the table’s air interface remain out of sync for more than 500 milliseconds (ms). Checked with the safety inputs configured in Machine Settings > General Settings > Tool Interfaces, Table tab, Air Valve tab, and the tool safety devices in place; this setting is saved.

Effect: Alarm (red line): the interface valve closes; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • one of the two safety sensors is faulty, out of calibration or disconnected;
  • unstable pressure.

How to resolve:

  1. Check the two safety inputs in Machine Diagnostics > PLC, under the Card Monitoring tab: they must change state simultaneously.
  2. Check the wiring and calibration of the sensor that is lagging behind; replace it if faulty (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the air interface is enabled; this option is configured by CEMAS.

Selection form

Alarms from the selective modules (up to two), which protect and distribute the 24 V power supply across multiple channels. These are configured under Machine Settings > General Settings > Components, on the Selective Modules tab.

M47000-0.XX – Selective module – Error

What this means: the 24 V selective protection module is signalling a fault: a channel has tripped due to an overload or short circuit, or the diagnostic signal is invalid. In the code, XX is the module number (from 01 to 02).

Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle. The circuit powered by the tripped channel is de-energised.

Probable causes:

  • overload or short circuit on a load connected to the channel (Check fault);
  • faulty module.

How to resolve:

  1. Check on the module which channel is faulty (red LED).
  2. Eliminate the cause of the overload on the connected load (maintenance technician).
  3. Reset the channel via the module.

Recovery: after resetting the channel, press Reset in the Alarm Monitor; if the fault persists, contact support.

Safety:

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation must only be carried out by qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the selective module is present (Machine settings > General settings > Components, Selective modules tab), option configured by CEMAS.

Error check

How to identify it: a channel on the selective module has a red or flashing LED.

Check:

  1. Check on the module which channel has tripped.
  2. Check the load supplied by the channel (short circuit or excessive current draw).

Remedy: eliminate the cause and reset the channel in accordance with the module manual (maintenance technician).

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation is reserved for qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

I/O interface

Alarms from the IO interface, the welding machine’s network-based input/output module dedicated to the head, table or mirror assembly: module not configured, unreachable or faulty. The status of the modules can be viewed under Machine Diagnostics > PLC, on the PLC Hardware tab.

The interface is configured under Machine Settings > General Settings > Tool Interfaces, on the zone tab, under the Inputs tab.

M48000-1.XX - Head - I/O interface - Device not configured

What this means: The head’s I/O interface is not configured on the PLC network. Operation is only permitted with the interface configured on the network.

Effect: Alarm (red line): on IR and HP machines, the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked. On laser machines, this is merely an indication.

Probable causes:

  • a new or replaced device has not yet been configured;
  • the machine configuration is not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Resolution: the issue resolves itself once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

Configure the I/O interface

How to recognise it: the alarm appears after the module has been replaced or the machine configuration has been changed.

Check:

  1. Check the status of the IO interface module in Machine Diagnostics > PLC, under the PLC Hardware tab.

Remedy: have the module configured (by a CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M48000-3.XX - Mirror (rear/left) - IO interface - Device not configured

What this means: The mirror’s IO interface is not configured on the PLC network. Only monitored via the interface configured on the network.

Effect: Alarm (red line): on IR cam-type vibration machines, the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • New or replaced device not yet configured;
  • Machine configuration not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Resolution: the error clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

Configure the I/O interface

How to recognise it: the alarm appears after the module has been replaced or the machine configuration has been changed.

Check:

  1. Check the status of the IO interface module in Machine Diagnostics > PLC, under the PLC Hardware tab.

Remedy: have the module configured (by a CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M48000-2.XX - Table - I/O interface - Device not configured

What this means: The table’s I/O interface is not configured on the PLC network. Only checked when the interface is configured on the network.

Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • new or replaced device not yet configured;
  • machine configuration not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Resolution: the error clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Configure the I/O interface

How to recognise it: the alarm appears after the module has been replaced or the machine configuration has been changed.

Check:

  1. Check the status of the IO interface module in Machine Diagnostics > PLC, under the PLC Hardware tab.

Remedy: have the module configured (by a CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M48001-3.XX – Mirror (rear/left) – IO interface – Device not accessible

What this means: The PLC is unable to communicate with the mirror’s I/O interface. Control is only possible via the network-configured interface.

Effect: Alarm (red line): on IR cam-type vibration machines, the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device switched off or not powered;
  • network cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; in Machine Diagnostics > PLC, on the PLC Hardware tab, the device must show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: the alarm clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

Connecting the I/O interface

How to identify the problem: the IO interface module shows an error or the LEDs are off.

Check:

  1. Check that the module is powered (LEDs on).
  2. Check the network cable and ensure that, under Machine Diagnostics > PLC, on the PLC Hardware tab, the module is shown as error-free.

Remedy: restore the power supply or reconnect the cable (by a maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M48001-1.XX – Head – I/O interface – Device not accessible

What this means: The PLC is unable to communicate with the head’s I/O interface. Can only be monitored via the network-configured interface.

Effect: Alarm (red line): on IR and HP machines, the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked. On laser machines, this is merely an indication.

Probable causes:

  • device switched off or not powered;
  • network cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; under Machine Diagnostics > PLC, on the PLC Hardware tab, the device must show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: clears automatically when the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

Connecting the I/O interface

How to identify the problem: the IO interface module shows an error or the LEDs are off.

Check:

  1. Check that the module is powered (LEDs on).
  2. Check the network cable and ensure that, under Machine Diagnostics > PLC, on the PLC Hardware tab, the module is shown as error-free.

Remedy: restore the power supply or reconnect the cable (by a maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M48001-2.XX – Table – I/O interface – Device not accessible

What this means: The PLC is unable to communicate with the table’s I/O interface. Check only when the interface is configured on the network.

Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • device switched off or not powered;
  • network cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; in Machine Diagnostics > PLC, on the PLC Hardware tab, the device must show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: the alarm clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Connecting the I/O interface

How to identify the problem: the IO interface module shows an error or the LEDs are off.

Check:

  1. Check that the module is powered (LEDs on).
  2. Check the network cable and ensure that, under Machine Diagnostics > PLC, on the PLC Hardware tab, the module is shown as error-free.

Remedy: restore the power supply or reconnect the cable (by a maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M48002-3.XX – Mirror (rear/left) – I/O interface – Hardware fault device

What this means: The mirror’s I/O interface is signalling a hardware fault. Can only be checked via the network-configured interface.

Effect: Alarm (red line): on IR cam-vibration machines, the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again and check whether the fault reoccurs.
  2. If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears itself once the condition no longer exists.

Availability: only on machines with the following types of cutting head: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

Check the hardware

How to identify it: the device sends signals indicating a fault even when the power supply and network are functioning normally.

Check:

  1. Switch the machine off and on again, and check whether the fault reoccurs.
  2. Check that the device is correctly installed and undamaged.

Remedy: replace the faulty device (maintenance technician) and have its configuration checked (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M48002-2.XX - Table - I/O interface - Hardware fault device

What this means: The table’s I/O interface is signalling a hardware fault. This can only be checked when the interface is configured for network operation.

Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again, and check whether the fault reoccurs.
  2. If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Check the hardware

How to identify it: the device sends signals indicating a fault even when the power supply and network are functioning normally.

Check:

  1. Switch the machine off and on again, and check whether the fault reoccurs.
  2. Check that the device is correctly installed and undamaged.

Remedy: replace the faulty device (maintenance technician) and have its configuration checked (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M48002-1.XX - Head - I/O interface - Hardware fault device

What this means: The head’s I/O interface is signalling a hardware fault. Can only be checked via the network-configured interface.

Effect: Alarm (red line): on IR and HP machines, the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked. On laser machines, this is merely an indication.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again, and check whether the fault reoccurs.
  2. If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

Check the hardware

How to identify it: the device sends signals indicating a fault even when the power supply and network are functioning normally.

Check:

  1. Switch the machine off and on again, and check whether the fault reoccurs.
  2. Check that the device is correctly installed and undamaged.

Remedy: replace the faulty device (maintenance technician) and have its configuration checked (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Machine valves

Alarms relating to the valve units in the welding machine’s network that control the actuators on the head, table or mirror: unit not configured, unreachable or faulty. The status of the units can be viewed under Machine Diagnostics > PLC, on the PLC Hardware tab.

The valve units are configured in Machine Settings > General Settings > Tool Interfaces, under the zone tab, in the Valves tab.

M51000-1.XX - Head - Machine valves - Device not configured

What this means: The head valve unit is not configured in the PLC network.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • New or replaced device not yet configured;
  • Machine configuration not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Resolution: the error clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

Configuring valve units

How to recognise it: the alarm appears after replacing the valve unit or changing the configuration.

Check:

  1. Check the status of the valve unit in Machine Diagnostics > PLC, under the PLC Hardware tab.

Remedy: have the valve unit configured; configuration must be carried out by a CEMAS technician.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M51000-3.XX - Mirror (rear/left) - Machine valves - Device not configured

What this means: The mirror valve unit is not configured in the PLC network.

Effect: Alarm (red line): the machine switches to manual mode (a welding process results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • New or replaced device not yet configured;
  • Machine configuration not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Resolution: the error clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

Configuring valve units

How to recognise it: the alarm appears after replacing the valve unit or changing the configuration.

Check:

  1. Check the status of the valve unit in Machine Diagnostics > PLC, under the PLC Hardware tab.

Remedy: have the valve unit configured; configuration must be carried out by a CEMAS technician.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M51000-2.XX - Table - Machine valves - Device not configured

What this means: The table valve unit is not configured in the PLC network.

Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • New or replaced device not yet configured;
  • Machine configuration not up to date.

How to resolve:

  1. Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
  2. Have the device configured (by a CEMAS technician).

Resolution: the error clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Configuring valve units

How to recognise it: the alarm appears after replacing the valve unit or changing the configuration.

Check:

  1. Check the status of the valve unit in Machine Diagnostics > PLC, under the PLC Hardware tab.

Remedy: have the valve unit configured; configuration must be carried out by a CEMAS technician.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M51001-2.XX - Table - Machine valves - Device not accessible

What this means: The PLC is unable to communicate with the table’s valve unit.

Effect: Alarm (red line): the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device switched off or not powered;
  • mains cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; in Machine Diagnostics > PLC, on the PLC Hardware tab, the device must show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: the alarm clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Valve unit start-up

How to identify the problem: the valve unit’s LEDs are off and the tools’ actuators are not moving.

Check:

  1. Check the power supply to the valve unit (LEDs should be on).
  2. Check the fuse or circuit breaker supplying power to it.

Remedy: restore power to the unit and check why the protection mechanism tripped (maintenance technician).

Check the message

How to identify the problem: the valve unit is powered on but the PLC cannot communicate with it.

Check:

  1. Check the unit’s communication LED and the network cable.
  2. Check under Machine Diagnostics > PLC, on the PLC Hardware tab, that the unit is reporting no errors.

Remedy: re-establish the connection (maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M51001-1.XX - Head - Machine valves - Device not accessible

What this means: The PLC is unable to communicate with the head valve unit.

Effect: Alarm (red line): the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device switched off or not powered;
  • mains cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; in Machine Diagnostics > PLC, on the PLC Hardware tab, the device must show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: the alarm clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

Valve unit start-up

How to identify the problem: the valve unit’s LEDs are off and the tools’ actuators are not moving.

Check:

  1. Check the power supply to the valve unit (LEDs should be on).
  2. Check the fuse or circuit breaker supplying power to it.

Remedy: restore power to the unit and check why the protection mechanism tripped (maintenance technician).

Check the message

How to identify the problem: the valve unit is powered on but the PLC cannot communicate with it.

Check:

  1. Check the unit’s communication LED and the network cable.
  2. Check under Machine Diagnostics > PLC, on the PLC Hardware tab, that the unit is reporting no errors.

Remedy: re-establish the connection (maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M51001-3.XX – Mirror (rear/left) – Machine valves – Device not accessible

What this means: The PLC is unable to communicate with the mirror valve unit.

Effect: Alarm (red line): the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • device switched off or not powered;
  • mains cable or connector disconnected or damaged;
  • tools not connected correctly.

How to resolve:

  1. Check that the device is powered and that the network LEDs are lit (maintenance technician).
  2. Check the cable and connectors; in Machine Diagnostics > PLC, on the PLC Hardware tab, the device must show no errors.
  3. If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).

Reset: the alarm clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

Valve unit start-up

How to identify the problem: the valve unit’s LEDs are off and the tools’ actuators are not moving.

Check:

  1. Check the power supply to the valve unit (LEDs should be on).
  2. Check the fuse or circuit breaker supplying power to it.

Remedy: restore power to the unit and check why the protection mechanism tripped (maintenance technician).

Check the message

How to identify the problem: the valve unit is powered on but the PLC cannot communicate with it.

Check:

  1. Check the unit’s communication LED and the network cable.
  2. Check under Machine Diagnostics > PLC, on the PLC Hardware tab, that the unit is reporting no errors.

Remedy: re-establish the connection (maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M51002-2.XX - Table - Machine valves - Hardware fault indicator

What this means: The table’s valve unit is signalling a hardware fault.

Effect: Alarm (red line): the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again and check whether the fault reoccurs.
  2. If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M51002-3.XX – Mirror (rear/left) – Machine valves – Hardware fault indicator

What this means: The mirror valve unit is reporting a hardware fault.

Effect: Alarm (red line): the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again and check whether the fault reoccurs.
  2. If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines with a mirror: IR (IR9, IR14, IR20), HP hot plate (HP9, HP14, HP20, HP-P125), IR 912-IR vibration and cam-driven IR vibration (911MK2-IR, 918MK2-IR).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M51002-1.XX - Head - Machine valves - Hardware fault indicator

What this means: The head valve unit is signalling a hardware fault.

Effect: Alarm (red line): the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.

Probable causes:

  • faulty device;
  • unstable power supply.

How to resolve:

  1. Switch the machine off and on again and check whether the fault reoccurs.
  2. If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).

Resolution: the fault clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on machines where the tools are also fitted to the head: laser, IR and HP hot plate.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

General machine information

General machine alerts: hardware safety, checklists, required test cycles and initialisation, movement restrictions excluded, outside dimensions exceeded.

M52000-0.XX – General machine information – Hardware security

What this means: the PLC safety modules (hardware safety) have not given their consent: the safety circuits have not authorised operation.

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • safety module in error or faulty;
  • safety circuit open or not reset.

How to resolve:

  1. Reset emergency stops and safety devices.
  2. Check in Machine Diagnostics > PLC, under the PLC Hardware tab, that the modules are not in error.
  3. If the fault persists, contact support (CEMAS technician).

Reset: the message disappears automatically once the condition no longer exists.

Safety:

Warning Before opening the electric panel, ensure the machine is safely shut down in accordance with the user manual. This operation is reserved for qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M52001-0.XX – General machine – Incomplete checklist

What this means: the machine checklist has not been completed.

Effect: Info (grey line): does not halt the automatic cycle.

How to resolve:

  1. In current versions of the control panel, the checklist cannot be completed via the HMI: contact CEMAS Elettra S.r.l. support.

Resolution: it disappears automatically once the condition no longer applies.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M52003-0.XX - General machine information - Initialisation confirmation required

What this means: the PLC has detected a new programme or configuration and requires confirmation of initialisation.

Effect: Info (grey line): does not halt the automatic cycle.

How to resolve:

  1. Do not alter the machine parameters.
  2. Contact CEMAS Elettra support, who will carry out the confirmation.

Resolution: the message disappears automatically once the condition no longer exists.

Safety:

Warning System initialisation erases machine data, including calibrations and planarity settings.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M52004-0.XX - General machine information - Movement constraints bypassed

What this means: motion constraints, which prevent movements that could cause collisions, are disabled using the Bypass motion constraints command in Machine diagnostics > Manual movements (in manual mode).

Effect: Warning (yellow line): the machine does not prevent collisions between moving parts; this is not a fault.

How to resolve:

  1. Move the machine slowly whilst monitoring it visually.
  2. Deactivate Bypass movement constraints in Machine diagnostics > Manual movements as soon as you have finished.

Resolution: the alarm clears automatically when the constraints are re-enabled.

Safety:

Warning With constraints disabled, an incorrect movement may damage the machines and tools.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M52005-0.XX – General machine specifications – External dimensions

What this means: the external clearance signal is missing: an external device (e.g. a robot) is not confirming that it is outside the machine’s working area. The signal is the Clearance signal under General Signals (Machine Settings > General Settings > Components, General Signals tab).

Effect: Warning (yellow line): indication only: does not stop the machine or halt the automatic cycle. Movements requiring authorisation await the signal.

Probable causes:

  • external device within the working area or in alarm mode;
  • signal connection interrupted.

How to resolve:

  1. Check that the external device is outside the work area and not in alarm.
  2. Check the signal in Machine Diagnostics > PLC, Signals tab.
  3. Check the signal wiring (maintenance technician).

Resolution: the fault clears automatically once the condition no longer exists.

Safety:

Warning Before working in the vicinity of the tools, ensure the machine is safely shut down in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the external out-of-limit signal is present (Machine settings > General settings > Components, General signals tab), an option configured by CEMAS.

M52006-0.XX – General machine – Programming error

1.24.16

What this means: PLC programming error. In current versions of the machine software, this message is provided but is not triggered.

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Planarity

Reports on the planarity check of the table and, on IR and HP machines, of the lower and upper mirrors. The check is carried out by a CEMAS Elettra technician using a dial gauge; the results can be found under Machine Diagnostics > Calibrations and Certifications, in the Planarity tab.

M53000-0.XX – Planarity – Not carried out

What this means: The table planarity check has not been carried out: the measurements have never been confirmed; a value has been modified or is outside the range of ± 0.05 mm; or the machine has been initialised.

Effect: Warning (yellow line). Information only: the machine is operating normally.

Probable causes:

  • new or initialised machine;
  • measurements modified or out of tolerance (Perform planarity test item).

How to resolve:

  1. Check the result in Machine Diagnostics > Calibrations and Certifications, Planarity tab, Table tab: Not performed indicates missing or unconfirmed measurements.
  2. Measure the four corners with the dial gauge, enter the values in Machine settings > General settings > Components, Planarity tab, and confirm (CEMAS technician).

Reset: the warning disappears once the check has been confirmed.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Carry out planarity tests

How to identify it: under Machine Diagnostics > Calibrations and Certifications, on the Planarity tab, the result is Not performed.

Check:

  1. Check whether the machine has been initialised or whether the values have been changed.

Remedy: the CEMAS technician measures the planarity using a dial gauge, enters the values in Machine settings > General settings > Components, under the Planarity tab, and confirms the check.

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M53001-0.XX – Planarity – Lower mirror not machined

1.24.16

What this means: The planarity check between the table and the mirror (lower mirror) has not been carried out: the measurements have never been confirmed, a value has been altered or is outside the range of ± 0.05 mm, or the machine has been initialised.

Effect: Warning (yellow line). Informative message only: the machine is operating normally.

Probable causes:

  • new or initialised machine;
  • measurements altered or out of tolerance.

How to resolve:

  1. Check the result in Machine Diagnostics > Calibrations and Certifications, Planarity tab, Lower Mirror tab: Not performed indicates missing or unconfirmed measurements.
  2. Measure the four corners with the dial gauge, enter the values in Machine Settings > General Settings > Components, Planarity tab, and confirm (CEMAS technician).

Reset: the warning disappears once the check has been confirmed.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP machines with hot plates (HP9, HP14, HP20, HP-P125).

M53002-0.XX – Planarity – Upper mirror not machined

1.24.16

What this means: the planarity check between the mirror and the head (upper mirror) has not been carried out: the measurements have never been confirmed; a value has been altered or is outside the range of ± 0.05 mm; or the machine has been initialised.

Effect: Warning (yellow line). Indication only: the machine is operating normally.

Probable causes:

  • new or initialised machine;
  • measurements altered or out of tolerance.

How to resolve:

  1. Check the result in Machine Diagnostics > Calibrations and Certifications, Planarity tab, Upper Mirror tab: Not performed indicates missing or unconfirmed measurements.
  2. Measure the four corners with the dial gauge, enter the values in Machine Settings > General Settings > Components, Planarity tab, and confirm (CEMAS technician).

Reset: the warning disappears once the check has been confirmed.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR machines (IR9, IR14, IR20) and HP hot plate machines (HP9, HP14, HP20, HP-P125).

ID Card Reader

Notifications from the Key ID reader, which the operator uses to identify themselves on the machine. This is configured under Machine settings > General settings > Components, on the Key ID reader tab.

M54000-0.XX - ID Key Reader - Device not configured

What this means: The ID key reader is not configured on the PLC network.

Effect: Warning (yellow line): information only: does not stop the machine or halt the automatic cycle. Identification using the key may not work.

Probable causes:

  • Reader not configured or incorrectly configured (Configure ID key reader).

How to resolve:

  1. Have the reader configured (by a CEMAS technician).

Resolution: the message disappears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.

Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), an option configured by CEMAS.

Configure the ID key reader

How to identify the problem: the reader is fitted and powered, but the machine reports it as unconfigured and the key is not being read.

Check:

  1. Check that the reader fitted is the model specified in the wiring diagram.
  2. Check that it has not been replaced recently.

Remedy: the reader must be configured by CEMAS Elettra personnel: contact support (CEMAS technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M54001-0.XX – ID Key Reader – Device not accessible

What this means: The PLC is unable to access the ID key reader.

Effect: Warning (yellow line): information only: does not stop the machine or halt the automatic cycle. Key identification may not work.

Probable causes:

  • reader switched off or not powered (Switch on ID key reader);
  • communication interrupted (Check communication).

How to resolve:

  1. Check that the reader is switched on (LEDs lit).
  2. Check the network and power cables (maintenance technician).

Resolution: the fault clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), an option configured by CEMAS.

ID Key Reader Activation

How to recognise this: the LEDs on the ID card reader are off.

Check:

  1. Check the reader’s power supply and its connector.

Remedy: restore the power supply; if the reader remains off, replace it (by a maintenance technician).

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This work must only be carried out by qualified personnel.
Check the message

How to identify the problem: the reader is switched on but is not communicating with the machine.

Troubleshooting:

  1. Check the reader’s communication LEDs.
  2. Check the network cable or the connection to the Smart accessory.

Remedy: Reconnect or replace the cable (by a maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M54002-0.XX – ID Key Reader – Hardware error

What this means: The ID key reader is reporting a hardware fault.

Effect: Warning (yellow line): this is for information only; it does not stop the machine or halt the automatic cycle. Key identification may not work.

Probable causes:

  • Faulty reader.

How to resolve:

  1. Switch the machine off and on again and check whether the warning disappears.
  2. If it persists, replace the reader (by a maintenance technician).

Reset: the warning disappears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), an option configured by CEMAS.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M54003-0.XX – ID Key Reader – ID Error

What this means: the code read from the key is invalid.

Effect: Warning (yellow line): information only: does not stop the machine or interrupt the automatic cycle. Key identification may not work. The key remains stored.

Possible causes:

  • Key is not authorised, damaged or inserted incorrectly.

How to resolve:

  1. Remove and reinsert the key.
  2. Try another authorised key.
  3. If no key is recognised, check the reader (maintenance technician).

Reset: once the cause has been rectified, select Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), option configured by CEMAS.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M54004-0.XX – ID Key Reader – Communication error

What this means: The ID key reader is not communicating with the welding machine’s PLC.

Effect: Warning (yellow line): this is for information purposes only; it does not stop the machine or halt the automatic cycle. Identification using the key may not work.

Probable causes:

  • Network or power cable disconnected (ID key reader connection).

How to resolve:

  1. Check the power supply and the reader’s LED.
  2. Check the network cable and connectors (by a maintenance technician).

Resolution: the message disappears automatically once the issue has been resolved.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), an option configured by CEMAS.

ID Key Reader Connection

How to recognise this: the reader is not communicating with the machine, often following work carried out on the control panel or the wiring.

Check:

  1. Check the reader’s power cable.
  2. Check the network cable and connectors.

Remedy: reconnect or replace any damaged cables (by a maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M54005-0.XX – ID Key Reader – Offline

What this means: the ID key reader, connected via the Smart accessory, is disconnected.

Effect: Warning (yellow line): this is for information only; it does not stop the machine or halt the automatic cycle. Key identification may not work.

Possible causes:

  • cable disconnected (Check connection);
  • communication with the Smart accessory interrupted (Check communication).

How to resolve:

  1. Check the cable between the reader and the Smart accessory.
  2. Check that the Smart accessory is switched on and communicating.

Resolution: the fault clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), an option configured by CEMAS.

Check the connection

How to recognise this: the reader, connected via the Smart accessory, appears to be disconnected and the key is not read.

Check:

  1. Check that the cable between the reader and the Smart accessory is connected and undamaged.
  2. Check that the Smart accessory is switched on.

Remedy: reconnect or replace the cable (by a maintenance technician).

Check the message

How to identify the problem: the reader is switched on but is not communicating with the machine.

Troubleshooting:

  1. Check the reader’s communication LEDs.
  2. Check the network cable or the connection to the Smart accessory.

Remedy: Reconnect or replace the cable (by a maintenance technician).

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Virtual master axis

Alarms for the master virtual axis, the reference axis that synchronises the table’s movement with the vertical and horizontal cams of the IR mirror during preheating. The cam profiles are recalculated and checked whenever the cam parameters or mirror type change; the axis is controlled manually via Machine Diagnostics > Manual Movements, Machine tab > Axes, Synchro tab.

Availability: only on IR cam-driven vibration machines (911MK2-IR, 918MK2-IR), with tools fitted with a cam-driven mirror.

Oops

Alarms from the uninterruptible power supply (UPS), which powers the machine during brief mains power cuts. This is configured under Machine Settings > General Settings > Components, on the UPS tab.

Availability: only on IR machines, HP machines with hot plates and IR cam-driven vibration machines (911MK2-IR, 918MK2-IR).

M58000-0.XX - UPS - General alarm

What this means: the uninterruptible power supply (UPS) is signalling a fault.

Effect: Alarm (red line): on IR and HP machines, the machine switches to manual mode; the automatic cycle and tool change remain blocked. On IR cam-type vibration machines, this is merely an indication.

Probable causes:

  • Internal fault in the UPS (Alarm code).

How to resolve:

  1. Read the alarm code on the UPS display and consult the manual.
  2. Have the UPS checked (by a maintenance technician).

Resolution: the alarm clears automatically once the fault has been rectified.

Safety:

Warning Before opening the electric panel, isolate the machine in accordance with the user manual. This operation must only be carried out by qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on IR machines, HP hot plate machines, IR 912-IR vibration machines and IR cam-type vibration machines (911MK2-IR, 918MK2-IR). Machine option: appears if the UPS is present (Machine settings > General settings > Components, UPS tab), option configured by CEMAS.

Alarm code

How to identify it: the component (e.g. air conditioner, heat exchanger, generator or UPS) displays an error code on its screen or via its LEDs.

Check:

  1. Read the code on the display or in the component’s diagnostics.
  2. Look up the meaning of the code in the component’s manual.

Remedy: carry out the actions indicated in the component manual (by a maintenance technician); if the error code persists, report it to CEMAS Elettra S.r.l. support.

Warning Before opening the electric panel, secure the machines in accordance with the user manual. This work must only be carried out by qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M58001-0.XX – UPS – Input voltage outside tolerance

What this means: the UPS is indicating that the input voltage is outside the tolerance range.

Effect: Alarm (red line): on IR and HP machines, the machine switches to manual mode; the automatic cycle and tool change remain locked. On IR cam-type vibration machines, this is merely an indication.

Probable causes:

  • unstable mains supply or mains voltage outside tolerance;
  • loose mains connection.

How to resolve:

  1. Check the machine’s mains voltage with the electrical department.
  2. Check the UPS input connections (maintenance technician).

Resolution: the fault clears automatically once the condition no longer exists.

Safety:

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation must only be carried out by qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on IR machines, HP machines with hot plates, IR 912-IR vibration machines and IR cam-type vibration machines (911MK2-IR, 918MK2-IR). Machine option: appears if the UPS is present (Machine settings > General settings > Components, UPS tab), option configured by CEMAS.

Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M58002-0.XX – UPS – Battery dead

What this means: the UPS indicates that the battery is not functioning properly: in the event of a mains power cut, it cannot power the machine.

Effect: Alarm (red line): on IR and HP machines, the machine switches to manual mode; the automatic cycle and tool change remain locked. On IR cam-type vibration machines, this is merely an indication.

Probable causes:

  • battery depleted or at the end of its service life (Replace battery).

How to resolve:

  1. Leave the machine switched on to recharge the battery and check whether the warning disappears.
  2. If it persists, replace the battery in accordance with the UPS manual (maintenance technician).

Reset: the warning disappears automatically once the condition no longer exists.

Safety:

Warning Before opening the electric panel, isolate the machines in accordance with the user manual. This operation must only be carried out by qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on IR machines, HP hot plate machines, IR 912-IR vibration machines and IR cam-type vibration machines (911MK2-IR, 918MK2-IR). Machine option: appears if the UPS is present (Machine settings > General settings > Components, UPS tab), option configured by CEMAS.

Changing the battery

How to recognise this: the UPS sends signals that the battery is not performing properly even after a full charge.

Check:

  1. Check the battery status on the UPS display.
  2. Check the battery’s installation date.

Remedy: replace the battery with an equivalent one, in accordance with the UPS manual (maintenance technician).

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This work must only be carried out by qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

M58003-0.XX – UPS – Power failure

What this means: the UPS indicates a power failure: the machine is either running on battery power or has no power supply.

Effect: Alarm (red line): on IR and HP machines, the machine switches to manual mode; the automatic cycle and tool change remain locked. On IR cam-type vibration machines, this is merely an indication. In automatic mode, the machine initiates the shutdown procedure by moving to a safe position; on IR and HP machines, manual movements are limited to 20 per cent of the speed.

Probable causes:

  • loss of mains power (Check connection);
  • UPS power switch open.

How to resolve:

  1. Check whether there is a mains power failure at the site.
  2. Check the switches and UPS connection (maintenance technician).
  3. When power is restored, check that the warning disappears before resuming operation.

Resolution: the message clears automatically once the condition no longer exists.

Safety:

Warning Before opening the electric panel, secure the machines in accordance with the user manual. This operation must only be carried out by qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: only on IR machines, HP machines with hot plates, IR 912-IR machines with vibration, and IR cam-type vibration machines (911MK2-IR, 918MK2-IR). Machine option: appears if the UPS is present (Machine settings > General settings > Components, UPS tab), option configured by CEMAS.

Check the connection

How to identify the problem: the UPS indicates a loss of input voltage.

Check:

  1. Check that mains power is present.
  2. Check the power switch and the UPS input cable.

Remedy: re-establish the connection (by a maintenance technician).

Warning Before opening the electric panel, secure the machine in accordance with the user manual. This operation must only be carried out by qualified personnel.
Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Tool trolley

Notifications regarding the trolley, the trolley used for tool changes. This is configured under Machine settings > General settings > Components, on the Trolley tab.

M59000-0.XX – Tool trolley – In stock

What this means: the presence sensor detects the trolley inserted into the machine in the correct position. The message appears at any stage, not just during tool change.

Effect: Warning (yellow line): the trolley is preventing the table from rising.

Possible causes:

  • trolley left in place after a tool change.

How to resolve:

  1. If the tool change is complete, remove the trolley.
  2. If the trolley is removed but the warning persists, check the presence sensor (maintenance technician).

Reset: the warning disappears automatically once the condition no longer exists.

Safety:

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the trolley is present (Machine settings > General settings > Components, Trolley tab), option configured by CEMAS.

M59001-0.XX – Tool trolley – Not available

What this means: Trolley not inserted into the machine. In current versions of the machine software, this warning is provided for but is not triggered.

Effect: Warning (yellow line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the trolley is present (Machine settings > General settings > Components, Trolley tab), option configured by CEMAS.

M59002-0.XX - Tool trolley - Trolley not in the correct position

The position sensor signals that the trolley is not correctly positioned.

Optional connectors

Alarms for optional connectors (up to five), additional connections between the machine and the tool. These are configured under Machine Settings > General Settings > Components, on the Optional Connectors tab; the tool specifies which ones it uses under Tool Settings > Configuration, on the Optional Connectors card.

M60000-0.XX - Optional connectors - Not fitted

1.23.12

What this means: with the tool installed, the optional connector XX is specified by the tool (Tool Settings > Configuration, Optional Connectors tab) but its presence sensor does not detect it. This is a continuous check. In the code, XX is the number of the optional connector (from 01 to 05).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • connector not connected or not fully inserted;
  • faulty connector presence sensor;
  • connector incorrectly specified in the tool parameters.

How to resolve:

  1. Connect the optional connector and insert it fully.
  2. Check under Tools Settings > Configuration, on the Optional Connectors tab, that the tool is actually supposed to use it.
  3. If it is connected but not detected, check the presence sensor (maintenance technician).

Reset: the message disappears automatically when the condition no longer exists.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: this appears if the optional connector is present (Machine settings > General settings > Components, Optional connectors tab), an option configured by CEMAS.

M60001-0.XX - Optional connectors - Present

1.23.12

What this means: when no tool is inserted, the sensor for the optional connector XX detects that it is connected. The tool parameters are irrelevant; when a tool is inserted, an unexpected connector does not trigger any alarms. In the code, XX is the number of the optional connector (from 01 to 05).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. It also blocks entry into the tool change sequence.

Probable causes:

  • connector left connected after the tool has been unloaded;
  • presence sensor always active.

How to resolve:

  1. Disconnect the optional connector and stow it away.
  2. If it is disconnected but the alarm persists, check the presence sensor (maintenance technician).

Reset: the fault clears automatically once the condition no longer exists.

Safety:

Warning Before working in the vicinity of the tool, ensure the machine is safely shut down in accordance with the user manual: moving parts.

Availability: machine option: appears if the optional connector is present (Machine settings > General settings > Components, Optional connectors tab), option configured by CEMAS.

M60002-0.XX – Optional connectors – Incorrect position

1.23.12

What this means: optional connectors are either not fully connected or are in the wrong position. In current versions of the machine software, this warning is provided but is not triggered. In the code, XX is the number of the optional connector (from 01 to 05).

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the optional connector is present (Machine settings > General settings > Components, Optional connectors tab), option configured by CEMAS.

Electric panel doors

Alarms for the electric panel doors (up to four). These are configured under Machine settings > General settings > Components, on the Electric panel doors tab.

M61000-0.XX - Electric panel doors - Electric panel door not closed

1.25.0

What this means: the electric panel door sensor signals that the door is open. In the code, XX is the electric panel door number (from 01 to 04).

Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle. With the door open, the control cabinet is not cooled properly and the powered components are not protected.

Probable causes:

  • control cabinet door open or not fully closed;
  • door sensor faulty or misaligned.

How to resolve:

  1. Close the electric panel door.
  2. If it is closed and the fault indication persists, check the sensor (maintenance technician).

Reset: the warning disappears automatically once the condition no longer exists.

Safety:

Warning Before opening the electric panel, ensure the machines are safely shut down in accordance with the user manual. This operation must only be carried out by qualified personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

Availability: machine option: appears if the control of the electric panel doors is enabled (Machine settings > General settings > Components, Electric panel doors tab), an option configured by CEMAS.

Mirror rotation

Mirror rotation alarms: the two motors (master and slave) that rotate the mirror and the cylinder that locks it in its position. The status of the motors can be viewed under Machine Diagnostics > Motor Status, on the Rotation Axis tab.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured via CEMAS).

M63300-3.XX - Mirror (rear/left) - Mirror rotation - External alarm

1.25.0

What this means: the warning (external alarm for the mirror rotation motor) is provided for in the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear. In the alarm code, XX indicates the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the message appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a machine software version different from the one documented.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63400-3.XX – Mirror (rear/left) – Mirror rotation – Forward position timeout

1.25.0

What this means: The mirror rotation clamp has not reached the forward (locked) position within the time-out set in Machine Settings > General Settings > Tool Interfaces, under the Mirror > Rotation Axis tab, in the Clamp section.

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Possible causes:

  • No or insufficient compressed air (see Pneumatic control);
  • Cylinder mechanically jammed or mirror not aligned with its seat;
  • Valve or solenoid coil not working;
  • position sensor out of calibration or faulty (see Faulty sensors);
  • time-out set too short.

How to resolve:

  1. Check that compressed air is present at the correct pressure.
  2. Operate the cylinder manually via Machine Diagnostics > Manual Movements, Machine tab > Mirror Rotation and observe the movement.
  3. Check the valve and the forward position sensor LED (maintenance technician).
  4. If the movement is smooth but slow, increase the time-out on the same page (CEMAS technician).

Reset: alarm logged; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before carrying out any work on cylinders and air pipes, secure the machine in accordance with the user manual and release the compressed air (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP hot plate machines (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63200-3.XX – Mirror (rear/left) – Mirror rotation – Axis in alarm

1.25.0

What this means: this warning (mirror rotation motor summary alarm) is provided for in the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear. In the alarm code, XX indicates the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm not displayed in the Alarm Monitor. No effect on the machine.

How to resolve:

  1. If the alarm appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: this may indicate a machine software version different from the one documented.

Availability: only on IR and HP hot plate machines (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63000-3.XX – Mirror (rear/left) – Mirror rotation – Master motor alarm

1.25.0

What this means: Summary message: the master rotation motor has an alarm.

Effect: Message not displayed in the Alarm Monitor. Specific alarms for the rotation motors (M632xx and M633xx) appear.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured via CEMAS).

M63301-3.XX – Mirror (rear/left) – Mirror rotation – Protection alarm

1.25.0

What this means: One of the circuit breakers (logic thermal or power thermal) supplying power to the mirror rotation motor drive has tripped. In the alarm code, XX indicates the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). Motor disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the motor, cable or drive (entry Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not re-closed;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the circuit breaker (logic thermal or power thermal) for the mirror rotation motor (electrical maintenance technician).
  2. If it trips again, do not attempt to reset it: check for a short circuit or overload in the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and wiring.

Reset: it clears automatically when the circuit breaker is re-closed; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63201-3.XX - Mirror (rear/left) - Mirror rotation - Logic switch

1.25.0

What this means: The circuit breaker (thermal logic) for the mirror rotation motor drive has tripped: the enable input is low. In the alarm code, XX refers to the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; this signal alone does not switch the machine to manual mode.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the drive power supply (entry Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not re-closed;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the circuit breaker for the mirror rotation logic (electrical maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and the wiring.

Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a circuit breaker that has tripped.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63401-3.XX - Mirror (rear/left) - Mirror rotation - Reverse position timeout

1.25.0

What this means: the mirror rotation clamp cylinder has not reached the retraction (unlocked) position within the time-out set in Machine Settings > General Settings > Tool Interfaces, under the Mirror > Rotation Axis tab, in the Clamp Cylinder section.

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Possible causes:

  • No or insufficient compressed air (see Pneumatic control);
  • Cylinder mechanically jammed or mirror not aligned with its seat;
  • Valve or solenoid coil not working;
  • position sensor out of calibration or faulty (see Faulty sensors);
  • time-out set too short.

How to resolve:

  1. Check that compressed air is present at the correct pressure.
  2. Operate the cylinder manually via Machine Diagnostics > Manual Movements, Machine tab > Mirror Rotation and observe the movement.
  3. Check the valve and the LED on the reverse position sensor (maintenance technician).
  4. If the movement is smooth but slow, increase the time-out on the same page (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on cylinders and air pipes, secure the machine in accordance with the user manual and release the compressed air (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63001-3.XX – Mirror (rear/left) – Mirror rotation – Slave motor alarm

1.25.0

What this means: summary message: the rotation slave motor has an alarm.

Effect: Message not displayed in the Alarm Monitor. Alarms specific to the rotation motors (M632xx and M633xx) appear.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured via CEMAS).

M63202-3.XX – Mirror (rear/left) – Mirror rotation – Power switch

1.25.0

What this means: The circuit breaker (thermal overload) for the mirror rotation motor drive has tripped: the enable input is low. In the alarm code, XX refers to the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; this signal alone does not switch the machine to manual mode.

Probable causes:

  • circuit breaker tripped due to overload or short circuit on the motor or its cable (entry Circuit breaker (thermal) tripped);
  • circuit breaker opened for maintenance and not re-closed;
  • auxiliary contact or input wiring broken.

How to resolve:

  1. In the electric panel, reset the mirror rotation circuit breaker (electrical maintenance technician).
  2. If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
  3. If the circuit breaker is closed but the alarm persists, check the auxiliary contact and the wiring.

Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using Reset.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a circuit breaker that has tripped.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63402-3.XX - Mirror (rear/left) - Mirror rotation - Forward position not released

1.25.0

What this means: when the retraction command is issued, once the time-out has expired, the forward position sensor of the clamp cylinder is still active: either the cylinder has not started moving or the sensor remains active.

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; the alarm alone does not switch the machine to manual mode.

Probable causes:

  • cylinder mechanically jammed;
  • no compressed air or faulty valve;
  • sensor constantly active or out of calibration.

How to resolve:

  1. Check the compressed air supply and ensure nothing is blocking the cylinder.
  2. Observe the sensor LED whilst moving the cylinder manually; adjust or replace it if it remains lit (maintenance technician).

Reset: alarm stored; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before carrying out any work on cylinders and air pipes, secure the machines in accordance with the user manual and release the compressed air (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63302-3.XX - Mirror (rear/left) - Mirror rotation - Not configured

1.25.0

What this means: The fieldbus diagnostics (PROFINET) signal that the mirror rotation motor drive is either not configured or has a configuration that differs from that specified in the machine software. In the alarm code, XX refers to the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). Motor disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Probable causes:

  • the drive has been replaced with a non-identical one or has not yet been configured (see Configure drive);
  • drive configuration lost.

How to resolve:

  1. Check whether the drive has been replaced recently: the replacement must be identical to the original.
  2. Configure the drive (CEMAS technician).

Reset: the alarm will clear automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63002-3.XX - Mirror (rear/left) - Mirror rotation - Not in gear

1.25.0

What this means: the rotation slave motor has been disconnected from the master using Disconnect gearing in Machine Settings > General Settings > Tool Interfaces, under the Mirror > Rotation Axis tab, for example to align or reference the motors.

Effect: Warning (yellow line). Information only: the machine does not switch to manual mode.

Possible causes:

  • Disconnect Gearing left enabled after an adjustment.

How to resolve:

  1. Once the adjustment is complete, deactivate Disconnect gearing in Machine settings > General settings > Tool interfaces, under the Mirror > Rotation axis tab (CEMAS technician).
  2. Check the In Gearing indicator for the secondary motor in Machine Diagnostics > Motor Status.

Resolution: the warning disappears when the slave is re-engaged.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63003-3.XX – Mirror (rear/left) – Mirror rotation – ‘Not in gear’ warning

1.25.0

What this means: the rotation slave motor, which is ready, is not linked to the master, even though it has not been disconnected by the operator.

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Probable causes:

  • an alarm on one of the two motors;
  • motors misaligned beyond the tolerance.

How to resolve:

  1. Check the rotation motor alarms in Machine Status > Alarm Monitor and resolve them.
  2. Check the positions of the two motors and the In Gearing indicator in Machine Diagnostics > Motor Status.
  3. Press the Reset button on the Alarm Monitor; if engagement fails, contact support.

Reset: stored alarm; clear by pressing Reset on the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63303-3.XX - Mirror (rear/left) - Mirror rotation - Not accessible

1.25.0

What this means: The PLC is unable to communicate with the mirror rotation motor drive via the fieldbus (PROFINET). In the alarm code, XX refers to the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). Motor disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Probable causes:

  • drive switched off or without logic power supply (see Drive power-on);
  • network cable disconnected or damaged, or network switch not powered (see Check communication).

How to resolve:

  1. Check under Machine status > Alarm monitor to see if a circuit breaker alarm is also active: if so, resolve that first.
  2. Check that the drive’s display or status LEDs are lit (electrical maintenance technician).
  3. Check the network cable: the port LEDs must be lit or flashing (electrical maintenance technician).

Reset: the fault message clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

Safety:

Warning Electric panel: authorised electrical maintenance technician only, with the machine in a safe state as per the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP hot plate machines (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63403-3.XX – Mirror (rear/left) – Mirror rotation – Rear position not released

1.25.0

What this means: when the forward command is issued, once the time-out has expired, the sensor indicating the clamp cylinder is in the ‘back’ position is still active: either the cylinder has not started moving or the sensor remains active.

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; the alarm alone does not switch the machine to manual mode.

Probable causes:

  • cylinder mechanically jammed;
  • no compressed air or faulty valve;
  • sensor constantly active or out of calibration.

How to resolve:

  1. Check the compressed air supply and ensure nothing is blocking the cylinder.
  2. Observe the sensor LED whilst moving the cylinder manually; adjust or replace it if it remains lit (maintenance technician).

Reset: alarm logged; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before carrying out any work on cylinders and air pipes, secure the machine in accordance with the user manual and release the compressed air (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63203-3.XX – Mirror (rear/left) – Mirror rotation – Unreferenced axis

1.25.0

What this means: the mirror rotation motor is powered but does not have a reference position. In the alarm code, XX indicates the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Probable causes:

  • motor, encoder or drive replaced;
  • reference lost following an encoder fault.

How to resolve:

  1. Check the Referenced indicator for the motor under Machine Diagnostics > Motor Status.
  2. Reference the motor using Home position in Machine settings > General settings > Tool interfaces, Mirror > Rotation axis tab; for the secondary motor, Disconnect gearing must first be enabled (CEMAS technician).

Reset: clears automatically after referencing.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra S.r.l. personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP hot plate machines (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63004-3.XX – Mirror (rear/left) – Mirror rotation – Movement timeout

1.25.0

What this means: during a rotation, the mirror remains stationary outside the tolerance of the commanded position for more than 3 s (fixed value).

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Probable causes:

  • mechanical obstruction to rotation;
  • clamp not retracted;
  • motors not enabled or in alarm mode.

How to resolve:

  1. Check that nothing is obstructing the rotation of the mirror.
  2. Check the clamp and motor alarms in Machine Status > Alarm Monitor.
  3. Test rotation manually via Machine Diagnostics > Manual Movements, Machine tab > Table Rotation.

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; perform manual movements only when the work area is clear.
Warning The IR mirror and hot plate remain hot for a long time: only approach them once the machine has been secured in accordance with the user manual and after they have cooled down.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63404-3.XX – Mirror (rear/left) – Mirror rotation – External alarm

1.25.0

What this means: the warning (external alarm for the mirror rotation clamp) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.

Effect: Alarm (red line). No effect on the machine.

How to resolve:

  1. If the warning appears, note down the full code, the time and the machine’s operating conditions.
  2. Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63304-3.XX - Mirror (rear/left) - Mirror rotation - Drive hardware error

1.25.0

What this means: the field network diagnostics signal a hardware fault in the mirror rotation motor drive or one of its modules. In the alarm code, XX refers to the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). Motor disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Probable causes:

  • drive electronics fault;
  • unstable logic power supply.

How to resolve:

  1. Read the fault code (Drive fault code) in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis error code entry).
  2. Switch the machine off and on again in accordance with the user manual (maintenance technician).
  3. If the fault recurs, report the code to the service department: the drive may need replacing.

Reset: the fault message clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.

Safety:

Warning Electric panel: authorised electrical maintenance technicians only, with the machine secured in accordance with the user manual. Do not repeatedly reset a tripped circuit breaker.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63405-3.XX – Mirror (rear/left) – Mirror rotation – Both position sensors

1.25.0

What this means: the forward and reverse position sensors on the clamp cylinder are active at the same time.

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Probable causes:

  • faulty sensor or sensor that is constantly active (see Sensors not working);
  • sensors positioned so that they both detect the cylinder;
  • sensor inputs set incorrectly.

How to resolve:

  1. Observe the LEDs on the two sensors whilst moving the cylinder: each one should light up only when in its own position (maintenance technician).
  2. Adjust or replace the sensor that remains lit.
  3. Check the inputs under Machine Settings > General Settings > Tool Interfaces, Mirror > Rotation Axis tab, Clamp Cylinder section (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before carrying out any work on cylinders and air pipes, secure the machine in accordance with the user manual and release the compressed air (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63005-3.XX – Mirror (rear/left) – Mirror rotation – Misaligned axes

1.25.0

What this means: the positions of the master and slave rotation motors differ by more than 5 mm (fixed value).

Effect: Alarm (red line). Indication only: the machine does not switch to manual mode.

Probable causes:

  • mechanical impact or slippage;
  • incorrect homing of one of the motors.

How to resolve:

  1. Compare the positions of the primary and secondary motors in Machine Diagnostics > Motor Status.
  2. Realign and re-reference the motors (CEMAS technician).

Reset: alarm stored; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements must only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63305-3.XX – Mirror (rear/left) – Mirror rotation – Actuation alarm

1.25.0

What this means: The mirror rotation motor drive has encountered an error: it has detected a problem with the motor, the encoder, the power supply or the movement. This is not signalled when safety guards are open or the safety light curtain is in alarm mode. In the alarm code, XX indicates the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). Motor disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Probable causes:

  • overload or obstructed movement;
  • motor or drive overheating;
  • damaged encoder or motor cables.

How to resolve:

  1. Read the fault code (Drive fault code) in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis error code entry).
  2. Check that nothing is obstructing movement and that the motor is not overheating.
  3. Press the Reset button on the Alarm Monitor; if the fault reoccurs, report the code to support.

Reset: stored alarm; clear by pressing Reset on the Alarm Monitor after rectifying the cause.

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63406-3.XX - Mirror (rear/left) - Mirror rotation - Both commands

1.25.0

What this means: the forward and reverse outputs of the clamp cylinder are active at the same time: the control configuration is inconsistent.

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; this signal alone does not switch the machine to manual mode.

Probable causes:

  • Control outputs set incorrectly, for example, the same output used for both commands.

How to resolve:

  1. Check the outputs in Machine Settings > General Settings > Tool Interfaces, Mirror > Rotation Axis tab, Clamp Cylinder section (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Machine settings may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP hot plate machines (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63006-3.XX - Mirror (rear/left) - Mirror rotation - Axle not in position

1.25.0

What this means: the mirror is not in the rest position for rotation, or the correct position sensor is not active.

Effect: Warning (yellow line). Information only: the machine cannot be switched to manual mode.

Probable causes:

  • rotation interrupted or not completed;
  • position sensor out of calibration or faulty.

How to resolve:

  1. Move the mirror into position using Home position or via Machine diagnostics > Manual movements, Machine tab > Mirror rotation.
  2. With the mirror in position, check the sensor LED; adjust or replace it if it does not switch (maintenance technician).

Reset: the warning disappears when the mirror is in position.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; perform manual movements only when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63306-3.XX – Mirror (rear/left) – Mirror rotation – Technical object warning

1.25.0

What this means: the motion control unit of the PLC for the mirror rotation motor is signalling an error, such as a tracking error (the axis is not following the commanded position), a software limit being exceeded, or a re-referencing error. This error is not signalled when the safety guards are open or the safety barrier is in alarm. In the alarm code, XX indicates the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). Motor disabled and mirror rotation not ready; the alarm alone does not switch the machine to manual mode.

Probable causes:

  • movement braked or obstructed;
  • drive in error or not ready;
  • commanded position outside the axis limits.

How to resolve:

  1. Read the active bits of the Alarms word card in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis status code entry).
  2. Resolve any other drive alarms.
  3. Press the Reset button on the Alarm Monitor and attempt a manual movement via Machine Diagnostics > Manual Movements, Machine tab > Mirror Rotation.

Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on axes and moving parts, secure the machine in accordance with the user manual; perform manual movements only when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63307-3.XX – Mirror (rear/left) – Mirror rotation – Positive overtravel alarm

1.25.0

What this means: the positive over-travel limit switch for the mirror rotation motor (if enabled) has been triggered: the axis is beyond its working travel. In the alarm code, XX indicates the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). Motor disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Probable causes:

  • axis moved beyond its travel range in manual mode or with motion constraints disabled;
  • lost or incorrect home position;
  • limit switch faulty, out of calibration or disconnected (see Faulty sensors).

How to resolve:

  1. Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab > Mirror Rotation (see Release Overtravel).
  2. Whilst the axis is moving, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
  3. If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63407-3.XX - Mirror (rear/left) - Mirror rotation - Not in position

1.25.0

What this means: A rotation command has been issued whilst the clamp has not been retracted.

Effect: Alarm (red line). Rotation motors disabled and mirror rotation not ready; this signal alone does not switch the machine to manual mode.

Probable causes:

  • cylinder remaining in the locking position;
  • retraction position sensor not active.

How to resolve:

  1. Move the cylinder backwards via Machine Diagnostics > Manual Movements, Machine tab > Mirror Rotation and repeat the movement.
  2. Check the reverse position sensor (maintenance technician).

Reset: alarm stored; clear by selecting Reset in the Alarm Monitor after rectifying the cause.

Safety:

Warning Before working on cylinders and air pipes, secure the machine in accordance with the user manual and release the compressed air (maintenance technician).

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

M63308-3.XX - Mirror (rear/left) - Mirror rotation - Negative overtravel alarm

1.25.0

What this means: the negative over-travel limit switch for the mirror rotation motor (if enabled) has been triggered: the axis is beyond its working travel. In the alarm code, XX indicates the motor (also named in the text): 01 master, 02 slave.

Effect: Alarm (red line). Motor disabled and mirror rotation not ready; this alarm alone does not switch the machine to manual mode.

Probable causes:

  • axis moved beyond its travel limit in manual mode or with motion constraints disabled;
  • lost or incorrect home position;
  • limit switch faulty, out of calibration or disconnected (see Faulty sensors).

How to resolve:

  1. Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab > Mirror Rotation (see Release Overtravel).
  2. Whilst the axis is moving, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
  3. If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).

Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).

Safety:

Warning Before carrying out any work on axes or moving parts, secure the machine in accordance with the user manual; manual movements should only be carried out when the work area is clear.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.

Availability: only on IR and HP machines with hot plates (IR9, IR14, IR20, HP9, HP14, HP20, HP-P125). Machine option: Rotation axis of the mirror enabled (configured by CEMAS).

Tool Conveyor

Alarms for the tool roller conveyor, the roller system that transports the tool onto the table during tool change: slide, clamps, rollers and tool presence. The roller conveyor is configured in Machine Settings > General Settings > Components, under the Tool Roller Conveyor tab.

Availability: only on HP laser and hot plate machines. Machine option: appears if the Tool Conveyor is present (Machine Settings > General Settings > Components, Tool Conveyor tab, Present).