Alarms
The alarm guide is a troubleshooting guide for the alerts displayed by the welding machine on the Machine Status > Alarm Monitor page. Each alarm explains what it means, how it affects the machine, the probable causes, the verification procedure, how to reset it and on which machines it may appear; below the alarm, the cause entries describe how to recognise and verify each cause.
The alerts are divided into two groups:
- Tool Alarms: fitted tools (actuators, presence sensors, voids, controls, Smart Tool, tool status);
- Machine Alarms: the welding machine (services, axes, tool interfaces, safety devices, machine cycles, heating sources and systems, cooling).
Alarm code: each alarm has a code such as M09000-1.03:
| Part | Example | Meaning |
|---|---|---|
| letter | M |
M machine alarm, T tool alarm |
| two digits | 09 |
unit (component) |
| single digit | 0 |
sub-group |
| two digits | 00 |
alarm number within the unit |
| digit after the hyphen | 1 |
zone: 0 general, 1 front, 2 table, 3 mirror (rear/left), 4 right-hand mirror |
| two digits after the full stop | 03 |
element number (e.g. actuator 3); 01 for individual components |
In the manual, the element number is indicated as XX.
Category: the colour of the row in the Alarm Monitor indicates the category: Alarm (red), Warning (yellow), Info (grey). The actual effect on the machine is described for each alarm in the Effect paragraph.
Reset: stored alarms are cleared once the cause has been rectified, using the Reset button on the Current Alarms tab (or via the external alarm reset signal, if connected), and reappear if the cause is still present; notifications linked to a condition disappear automatically. If the Reset faults with password option is enabled in Machine settings > General settings, the reset requires password authentication.
Before working on the electric panel, pressurised circuits, lasers, hot surfaces or moving parts, secure the machine in accordance with the user manual. If an alarm recurs, contact CEMAS Elettra support (Machine Diagnostics > Support).
Tool Alerts
Tool Alarms relate to the fitted tools: actuators, presences, vacuums, input and output commands, Smart Tools and the general status of the tools. The code begins with T and the text in Machine Status > Alarm Monitor begins with Tools, followed by the tools’ serial number in square brackets.
Any equipment alarm stops the machine: if it is in automatic mode, it switches to manual mode and neither the automatic cycle nor the tool change can be initiated. The parameters can be checked in Equipment Settings > Actuators and Presence Sensors; sensors and actuators can be tested manually via Machine Diagnostics > Manual Movements, under the Equipment tab.
Actuator
Alarms relating to machine actuators (clamps, slides, ejectors controlled by the machine’s valves): movements not completed within the expected time, inconsistent position sensors, position constraints not met, configuration of controls, valves and pins. XX is the actuator number; the parameters are found under Equipment Settings > Actuators and Presences, on the Actuators tab, whilst manual tests are found under Machine Diagnostics > Manual Movements, on the Equipment tab.
T01000-0.XX - Actuator - Rest position timeout
What this means: following the sleep command, the sleep sensor did not activate within the Sleep time specified in the Time-out unit (Equipment settings > Actuators and Presence, Actuators tab; default 5 s, −1 disables the check). In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.
Probable causes:
- stroke obstructed (Movement not completed);
- insufficient air supply or damaged hoses (Pneumatic check);
- sensor displaced or faulty (Sensors not working);
- time-out shorter than the stroke (Insufficient time).
How to resolve:
- Reset and select Standby in Machine Diagnostics > Manual Movements, Equipment tab: the button must display a green ring.
- If the actuator does not move: clear the stroke, check the air supply and hoses (maintenance technician).
- If it moves but the green halo does not appear: check the sensor and pins (Input pop-up, Rest tab).
- If it is delayed: increase the Rest time.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Move not completed
How to identify it: the actuator stops before reaching the position or reaches it without the sensor sending signals.
Check:
- Control the actuator from Machine Diagnostics > Manual Movements, Tools tab, and check whether it reaches the position: the button must display a green halo.
- If it stops before reaching the position: check for mechanical obstructions, incorrectly positioned parts or other actuators in the travel path.
- If it reaches the position but the green halo does not appear: in the actuator’s Input pop-up (Equipment settings > Actuators and sensors, Actuators tab), under the Idle or Work tab, the assigned pin must light up green when the actuator is in position.
Remedy: clear the travel path; correct the assigned pin (operator authorised to access tool settings) or the sensor wiring (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Not enough time
How to recognise this: the actuator reaches the position, but only after the time-out has expired (the green halo appears late).
Check:
- Control the actuator via Machine Diagnostics > Manual Movements, Tool tab, and estimate the travel time.
- Compare this with the Idle and Operating fields in the Timeout unit (Equipment settings > Actuators and Presences, Actuators tab).
Remedy: if the stroke is smooth but slow, increase the time-out, leaving a margin; if the stroke has become slower than usual, first check the air supply and flow regulators (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T01001-0.XX – Actuator – Working position timeout
What this means: following the work command, the work sensor did not activate within the Work time specified in the Time-out unit (Equipment settings > Actuators and Presences, Actuators tab; default 5 s, −1 disables the check). In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.
Probable causes:
- stroke obstructed (Movement not completed);
- insufficient air or damaged pipes (Pneumatic control);
- sensor displaced or faulty (Sensors not working);
- time-out shorter than the stroke (Insufficient time).
How to resolve:
- Reset and select Work in Machine Diagnostics > Manual Movements, Tools tab: the button must display a green ring.
- If the actuator does not move: clear the stroke, check the air supply and hoses (maintenance technician).
- If it moves but the indicator does not appear: check the sensor and pins (Input pop-up, Work tab).
- If it is delayed: increase the Job time.
Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Move not completed
How to identify it: the actuator stops before reaching the position or reaches it without the sensor sending signals.
Check:
- Control the actuator from Machine Diagnostics > Manual Movements, Tools tab, and check whether it reaches the position: the button must display a green halo.
- If it stops before reaching the position: check for mechanical obstructions, incorrectly positioned parts or other actuators in the travel path.
- If it reaches the position but the green halo does not appear: in the actuator’s Input pop-up (Equipment settings > Actuators and sensors, Actuators tab), under the Idle or Work tab, the assigned pin must light up green when the actuator is in position.
Remedy: clear the travel path; correct the assigned pin (operator authorised to access tool settings) or the sensor wiring (maintenance technician).
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Not enough time
How to recognise this: the actuator reaches the position, but only after the time-out has expired (the green halo appears late).
Check:
- Control the actuator via Machine Diagnostics > Manual Movements, Tool tab, and estimate the travel time.
- Compare this with the Idle and Operating fields in the Timeout unit (Equipment settings > Actuators and Presences, Actuators tab).
Remedy: if the stroke is smooth but slow, increase the time-out, leaving a margin; if the stroke has become slower than usual, first check the air supply and flow regulators (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T01002-0.XX – Actuator – Rest position not released
What this means: after the job command, when the time-out expires (the Job field in the Time-out unit, Equipment settings > Actuators and Presences, Actuators tab), the idle sensor is still active: either the actuator has not started, or the sensor remains on even though the actuator has moved. In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until a reset is performed.
Probable causes:
- actuator held in position (Actuator jammed);
- no air supply or valve not controlled (Pneumatic control);
- idle sensor always active (Sensors not working).
How to resolve:
- Reset and select Work in Machine Diagnostics > Manual Movements, Tools tab, whilst observing the actuator.
- If it does not start: release the components holding it in place, check Safety constraints, air supply and valve (maintenance technician).
- If it starts but the idle sensor LED remains lit: adjust or replace the sensor (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Actuator jammed
How to recognise this: the actuator does not move, or does not move from its position, when commanded.
Check:
- Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
- Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
- Check that the stroke is free from mechanical obstructions.
Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T01003-0.XX - Actuator - Operating position not released
What this means: after the standby command, when the time-out expires (the Standby field in the Time-out unit, Equipment settings > Actuators and Presences, Actuators tab), the work sensor is still active: either the actuator has not started, or the sensor remains on even though the actuator has moved. In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until a reset is performed.
Probable causes:
- actuator held in position (Actuator jammed);
- no air supply or valve not controlled (Pneumatic control);
- work sensor constantly active (Sensors not working).
How to resolve:
- Reset and select Rest in Machine Diagnostics > Manual Movements, Tool tab, whilst observing the actuator.
- If it does not start: release the components holding it in place, check Safety constraints, air supply and valve (maintenance technician).
- If it starts but the work sensor LED remains lit: adjust or replace the sensor (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Actuator jammed
How to recognise this: the actuator does not move, or does not move from its position, when commanded.
Check:
- Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
- Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
- Check that the stroke is free from mechanical obstructions.
Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T01004-0.XX – Actuator – External alarm
What this means: external actuator alarm, i.e. a fault signalled by a device connected to the actuator rather than by its position sensors. In current versions of the machine software, this alarm is provided for but is not activated. In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): none.
If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
T01005-0.XX - Actuator - Both position feedback signals
What this means: the actuator’s idle and operating sensors are active simultaneously: the actuator’s position cannot be determined. Control is continuous. In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.
Probable causes:
- a sensor also detects the opposite position (Sensor positioning);
- faulty sensor or sensor always active (Sensors not working);
- same pin assigned to both sensors.
How to resolve:
- Move the actuator via Machine Diagnostics > Manual Movements, Tools tab, whilst observing the LEDs: only one sensor should light up in each position.
- If an LED remains lit at all times: reposition or replace the sensor (maintenance technician).
- If the LEDs are correct: check in the Input pop-up (Equipment settings > Actuators and presence, Actuators tab) that Rest and Work have different pins.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Sensor positioning
How to identify this: the component’s two position sensors are active at the same time.
Check:
- Move the component to one position and check that only the LED for the corresponding sensor is lit.
- Repeat in the other position.
- Check that each sensor is securely fitted and detects only its own position.
Remedy: reposition or replace the sensor that remains active (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T01006-0.XX – Actuator – Both commands
What this means: the actuator receives both the ‘rest’ and ‘work’ commands simultaneously, for example from two external commands linked in the Input unit of the actuator pop-up window (Equipment settings > Cycle settings). In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.
Probable causes:
- external ‘Idle’ and ‘Work’ commands active simultaneously (Reset the commands);
- external device sending both signals.
How to resolve:
- Note down the input commands associated with Rest and Work (Equipment settings > Cycle settings, actuator pop-up, Inputs unit).
- Check in Machine diagnostics > PLC that they are not active simultaneously.
- Correct the association or the device sending the commands (maintenance technician).
Reset: once the cause has been eliminated, press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Reset the controls
How to recognise it: the Both commands alarm appears when the actuator’s external commands are activated.
Check:
- In Equipment settings > Cycle settings, in the actuator pop-up window, under the Input unit, note down the input commands selected for Idle and Operate.
- Check in the Signals tab under Machine Diagnostics > PLC that the two commands are not active at the same time.
Remedy: pair commands so that they cannot be active simultaneously, or rectify the device sending them (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T01007-0.XX - Actuator - Not in the rest position
What this means: A movement (table, head, other actuators, repositioning) has been requested that requires the actuator to be in the rest position, but the rest position sensor is not active: the safe position constraint is not met and the movement is not executed. In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.
Probable causes:
- actuator out of position or stuck (Actuator jammed);
- air pressure dropped or absent (Pneumatic control);
- rest position sensor displaced or faulty (Sensors not working).
How to resolve:
- Reset and select Rest in Machine Diagnostics > Manual Movements, Tools tab: the button must display a green ring.
- If the actuator does not move: check for obstructions, air supply and the valve (maintenance technician).
- If it is in the rest position but the green halo does not appear: check the LED and the sensor position (maintenance technician).
- Repeat the required movement.
Reset: once the cause has been rectified, select Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Actuator jammed
How to recognise this: the actuator does not move, or does not move from its position, when commanded.
Check:
- Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
- Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
- Check that the stroke is free from mechanical obstructions.
Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T01008-0.XX – Actuator – Not in operating position
What this means: A movement (table, head, other actuators, repositioning) has been requested that requires the actuator to be in operation, but the operational sensor is not active: the safe position constraint is not met and the movement is not executed. In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.
Probable causes:
- actuator has retracted or is stuck (Actuator jammed);
- air pressure has dropped during the cycle (Pneumatic control);
- work sensor displaced or faulty (Sensors not working).
How to resolve:
- Reset and select Operation in Machine Diagnostics > Manual Movements, Tool tab: the button must display a green ring.
- If the actuator does not move: check for obstructions, air supply and the valve (maintenance technician).
- If it is operating but the green halo does not appear: check the LED and the sensor position (maintenance technician).
- Repeat the required movement.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Actuator jammed
How to recognise this: the actuator does not move, or does not move from its position, when commanded.
Check:
- Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
- Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
- Check that the stroke is free from mechanical obstructions.
Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T01009-0.XX – Actuator – Incorrect control address
What this means: a command associated with the actuator refers to a non-existent input or output command, for example one that was deleted after the association was made. This is a tool configuration error. In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- command deleted or invalid (Reset commands).
How to resolve:
- Check the outputs in the actuator’s Commands pop-up (Tooling Settings > Actuators and Presences, Actuators tab, visible in the advanced view).
- Check the external commands in the Input unit of the actuator pop-up (Tool settings > Cycle settings).
- Choose the correct command or Select signal if it is not required.
Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.
Reset the controls
How to recognise it: the alarm appears after deleting or modifying the tools’ input or output commands.
Check:
- Open the actuator’s Commands pop-up (Equipment Settings > Actuators and Presences, Actuators tab, visible in the advanced view) and check that the selected outputs exist in the Output Commands tab.
- Check the external commands in the Input unit of the actuator pop-up (Tool Settings > Cycle Settings).
Remedy: select the correct commands again or Select Signal if they are not required, then save (Save Changes).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T01010-0.XX – Actuator – Incorrect valve address
What this means: the valve assigned to the actuator is invalid: the valve number is outside the machine’s range (up to 10). The valve menu is next to the Input button (Equipment settings > Actuators and presences, Actuators tab). In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- valve not selected or does not exist on the interface (Reset the valve);
- tools created on a machine with different valves.
How to resolve:
- In the Cavities unit, check the interface on which the actuator is mounted.
- Select the valve that controls the actuator from the menu.
- Test the actuator via Machine Diagnostics > Manual Movements, Tooling tab.
Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Reset the valve
How to recognise it: the alarm appears on a new actuator or after changing the interface in the Cavity unit.
Check:
- Check in the Cavity unit (Tooling settings > Actuators and presences, Actuators tab) the interface on which the actuator is mounted.
- Check in the valve menu, next to the Input button, that the valve controlling the actuator is selected.
Remedy: correct the interface and valve, save (Save changes) and test the actuator via Machine diagnostics > Manual movements, Equipment tab. With the machine option General valve pack, configured by CEMAS, the valves suggested are always those shown on the table.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T01011-0.XX - Actuator - Incorrect actuator connector pin address
What this means: an actuator sensor is assigned to a pin that does not exist on the connector: for a 24-pin connector, pins 3–24 are valid; for a 32-pin connector, pins 3–32; and for a 64-pin or custom connector, pins 1–64. In the code, XX is the actuator number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Possible causes:
- unassigned or invalid pin (Reset inputs);
- interface or connector changed after configuration.
How to resolve:
- Open the actuator’s Input pop-up (Machine Settings > Actuators and Presences, Actuators tab) and check the selected pin (orange) in the Idle and Work tabs.
- Assign the pins from the tool’s wiring diagram.
- Check the interface selected in the Cavity unit.
Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Reset the inputs
How to recognise this: in the actuator’s Input pop-up, the selected pin (orange) is missing from one of the tabs, or an invalid pin has been assigned to the plug.
Check:
- Open the actuator’s Input pop-up (Equipment settings > Actuators and presences, Actuators tab) and check the Rest and Work tabs.
- Compare the pins with the tool’s wiring diagram.
- Check that the interface selected in the Cavities unit is the one to which the sensors are wired.
Remedy: assign the correct pins and save (Save changes).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Attendance
Alarms relating to tool presence, the sensors that monitor workpieces (photocells, microswitches, fibre optics): presence or absence not detected within the expected time, constraints not met, pin and command configuration, anti-repeat check. XX is the presence number; the parameters are found under Equipment Settings > Actuators and Presences, on the Presences tab.
T02000-0.XX - Presence - Presence timeout
What this means: when a presence is expected (automatically or during a tool change), the sensor has not been triggered within the Presence time specified in the Time-out unit (Tool Settings > Actuators and Presences, Presences tab; default 2 s, 0 disables the check). In the code, XX is the presence number (from 01 to 20).
Effect: Alarm (red line): with the presence in Safety mode (Mode unit), the machine switches to manual mode; the automatic cycle and tool change remain blocked. In Normal mode, this is merely a warning.
Probable causes:
- workpiece missing or incorrectly positioned (Object not present or incorrectly positioned);
- sensor displaced or out of alignment (Check not carried out);
- time-out too short (Insufficient time).
How to resolve:
- Position the workpiece correctly.
- Check in Machine Diagnostics > Manual Movements, under the Fixture tab, that the presence indicator turns green.
- If it remains grey whilst the workpiece is in place: check the sensor (maintenance technician).
- If it activates too late: increase the Presence time.
Reset: whilst the cycle is running, it remains stored (Reset in the Alarm Monitor); otherwise, it clears automatically.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Item missing or incorrectly positioned
How to identify the problem: the presence indicator remains grey because the part is missing or is not in the position where the sensor detects it.
Check:
- Check that the part is in its correct position and correctly seated.
- Remove and reinsert the part, observing the presence indicator in Machine Diagnostics > Manual Movements, Tool tab (green = presence active) and the sensor LED.
Remedy: position the workpiece correctly; if the indicator light does not change state with the workpiece in place, the cause is the sensor (see Check not performed or Sensors not working).
Not enough time
How to recognise it: the presence sensor is activated, but only after the time-out has expired, for example because the workpiece reaches the sensor following a movement.
Check:
- Observe automatically how long it takes for the presence indicator light to turn green.
- Compare this with the Presence field in the Time-out unit (Equipment settings > Actuators and presence, Presence tab; default 2 s).
Remedy: increase the Presence field, leaving a margin, and save (Save changes).
Check not carried out
How to identify this: the part is in place but the presence sensor does not detect it: the sensor LED is off and the presence indicator light is grey.
Check:
- Check the sensor LED whilst the component is in place.
- Check the sensor’s position, mounting and cleanliness.
- Check the calibration (sensitivity or activation distance) in accordance with the sensor manual.
Remedy: reposition, calibrate or replace the sensor (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T02001-0.XX – Presence – Absence timeout
What this means: when an absence is expected (either automatically or during a tool change), the sensor has not deactivated within the Absence time specified in the Time-out unit (Equipment settings > Actuators and Presences, Presences tab; default 2 s, 0 disables the check). In the code, XX is the presence number (from 01 to 20).
Effect: Alarm (red line): with the presence in Safety mode (Mode unit), the machine switches to manual mode; the automatic cycle and tool change remain blocked. In Normal mode, this is merely a warning.
Probable causes:
- workpiece or residue in front of the sensor (Object present or incorrectly positioned);
- sensor out of calibration or constantly active (Check not carried out);
- time-out too short (Insufficient time).
How to resolve:
- Remove the workpiece and any debris.
- Check in Machine Diagnostics > Manual Movements, under the Tool tab, that the presence indicator turns grey.
- If it remains green without a workpiece: check the sensor (maintenance technician).
- If it takes too long to deactivate: increase the Absence time.
Reset: whilst the cycle is in progress, it remains stored (Reset in the Alarm Monitor); otherwise, it clears automatically.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Object present or incorrectly positioned
How to recognise this: the presence indicator remains green because the workpiece, or a residue, is still in front of the sensor.
Check:
- Check that the workpiece has been removed and that there are no scraps or residues remaining in front of the sensor.
- Replace and remove the workpiece whilst observing the presence indicator in Machine Diagnostics > Manual Movements, Tooling tab (grey = presence not active).
Remedy: remove the workpiece and any residue; if the indicator light remains green without a workpiece present, the cause is the sensor (see Check not performed or Sensors not working).
Not enough time
How to recognise it: the presence indicator switches off, but only after the time-out has expired – for example, because the part is slowly moving away from the sensor.
Check:
- Observe automatically how long it takes for the presence indicator to turn grey.
- Compare this with the Absence field in the Time-out unit (Equipment settings > Actuators and presence, Presence tab; default 2 s).
Remedy: increase the Absence field, leaving a margin, and save (Save changes).
Check not carried out
How to recognise this: the object has been removed but the sensor continues to detect it: the sensor LED is on and the green presence indicator is lit.
Check:
- Check that the sensor is not detecting fixed parts of the tools or reflections.
- Check the sensor’s position, mounting and cleanliness.
- Check the calibration in accordance with the sensor manual.
Remedy: reposition, calibrate or replace the sensor (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T02002-0.XX - Presence - Incorrect connector pin address
What this means: the presence sensor is assigned to a pin that does not exist on the connector: for a 24-pin connector, pins 3–24 are valid; for a 32-pin connector, pins 3–32 are valid; for a 64-pin or custom connector, pins 1–64 are valid. In the code, XX is the presence number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- unassigned or invalid pin (Reset inputs);
- interface or connector changed after configuration.
How to resolve:
- Open the Input pop-up for the presence sensor (Equipment settings > Actuators and presence sensors, Presences tab) and check the selected pin (orange).
- Assign the pin from the tool’s wiring diagram.
- Check the interface selected in the Cavities unit.
Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Reset the inputs
How to recognise this: the presence indicator does not match the status of the component, or the Input pop-up does not have a valid pin.
Check:
- Open the Input pop-up for the presence sensor (Equipment Settings > Actuators and Presence Sensors, Presence tab): the selected pin (orange) must be the one shown in the wiring diagram and should light up green when the part is detected.
- Check the interface selected in the Cavity unit.
- Check the Contact unit (visible in the advanced view): Normally Open or Normally Closed depending on the sensor.
Remedy: correct the pin, interface or contact type and save (Save changes).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T02003-0.XX - Presence - Absent
What this means: A movement requiring active presence (presence constraint) has been requested, but the sensor does not detect the workpiece: the movement is not executed. In the code, XX is the presence number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- workpiece missing or incorrectly positioned (Object not present or incorrectly positioned);
- sensor displaced or faulty (Sensors not working);
- pins or contacts incorrectly set (Reset the inputs).
How to resolve:
- Position the part correctly.
- Check in Machine Diagnostics > Manual Movements, under the Tools tab, that the presence indicator turns green.
- If it remains grey: check the sensor (maintenance technician), the pin in the Input pop-up and the Contact unit (Tool Settings > Actuators and Presences, Presence tab).
- Repeat the movement.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Item missing or incorrectly positioned
How to identify the problem: the presence indicator remains grey because the part is missing or is not in the position where the sensor detects it.
Check:
- Check that the part is in its correct position and correctly seated.
- Remove and reinsert the part, observing the presence indicator in Machine Diagnostics > Manual Movements, Tool tab (green = presence active) and the sensor LED.
Remedy: position the workpiece correctly; if the indicator light does not change state with the workpiece in place, the cause is the sensor (see Check not performed or Sensors not working).
Reset the inputs
How to recognise this: the presence indicator does not match the status of the component, or the Input pop-up does not have a valid pin.
Check:
- Open the Input pop-up for the presence sensor (Equipment Settings > Actuators and Presence Sensors, Presence tab): the selected pin (orange) must be the one shown in the wiring diagram and should light up green when the part is detected.
- Check the interface selected in the Cavity unit.
- Check the Contact unit (visible in the advanced view): Normally Open or Normally Closed depending on the sensor.
Remedy: correct the pin, interface or contact type and save (Save changes).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T02004-0.XX – Presence – Not absent
What this means: A movement has been requested that requires non-active presence (movement constraint), but the sensor is still detecting an object: the movement is not carried out. In the code, XX is the presence number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- workpiece or residue in front of the sensor (Object present or incorrectly positioned);
- sensor out of calibration or constantly active (Sensors not functioning);
- pins or contacts incorrectly set (Reset the inputs).
How to resolve:
- Remove the part or residue.
- Check in Machine Diagnostics > Manual Movements, under the Tools tab, that the presence indicator turns grey.
- If it remains green: check the sensor (maintenance technician), the pin in the Input pop-up and the Contact unit (Tool Settings > Actuators and Presences, Presence tab).
- Repeat the movement.
Reset: once the cause has been rectified, select Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Object present or incorrectly positioned
How to recognise this: the presence indicator remains green because the workpiece, or a residue, is still in front of the sensor.
Check:
- Check that the workpiece has been removed and that there are no scraps or residues remaining in front of the sensor.
- Replace and remove the workpiece whilst observing the presence indicator in Machine Diagnostics > Manual Movements, Tooling tab (grey = presence not active).
Remedy: remove the workpiece and any residue; if the indicator light remains green without a workpiece present, the cause is the sensor (see Check not performed or Sensors not working).
Reset the inputs
How to recognise this: the presence indicator does not match the status of the component, or the Input pop-up does not have a valid pin.
Check:
- Open the Input pop-up for the presence sensor (Equipment Settings > Actuators and Presence Sensors, Presence tab): the selected pin (orange) must be the one shown in the wiring diagram and should light up green when the part is detected.
- Check the interface selected in the Cavity unit.
- Check the Contact unit (visible in the advanced view): Normally Open or Normally Closed depending on the sensor.
Remedy: correct the pin, interface or contact type and save (Save changes).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T02005-0.XX - Presence - Incorrect command address
What this means: an output command associated with a presence (Commands pop-up, Outputs unit) does not exist or is invalid, for example because it has been deleted from the Output Commands tab. In the code, XX is the presence number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- output command deleted or invalid (Reset commands).
How to resolve:
- Open the Commands pop-up for presence (Tool Settings > Actuators and Presences, Presences tab, visible in the advanced view).
- Select the command for Presence and Absence, or Select signal if not required.
Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.
Reset the controls
How to recognise it: the alarm appears after deleting or modifying the tools’ output commands.
Check:
- Open the Commands pop-up for presence (Equipment settings > Actuators and presences, Presence tab, visible in the advanced view).
- Check that the commands selected for Presence and Absence exist in the Output Commands tab.
Solution: select the commands again or Select the signal if they are not required, then save (Save changes).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T02006-0.XX - Presence - Anti-duplicate check
What this means: at the start of a new cycle, a presence with Anti-repeat enabled (Equipment settings > Actuators and presences, Presences tab) still detects the part welded in the previous cycle: the machine waits for it to be removed, so as not to weld it twice. In the code, XX is the presence number (from 01 to 20).
Effect: Info (grey line): the cycle does not start until the workpiece is removed; this is not a fault.
Possible causes:
- Welded part not unloaded (Remove welded part);
- Sensor out of calibration or constantly active (Sensors not working).
How to resolve:
- Remove the welded part.
- If the error persists: check under Machine Diagnostics > Manual Movements, Tools tab, that the presence indicator is grey; if it is green, check the sensor (maintenance technician).
Reset: the error clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Remove the welded part
How to recognise this: when the cycle starts, the anti-repeat check appears and the welded part is still in the tool.
Check:
- Check whether the part from the previous cycle is still in the tool.
- Check which presences have Anti-repeat set to Yes (Tool settings > Actuators and presences, Presences tab).
Remedy: remove the welded part and restart the cycle.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Vacuum
Tool vacuum alarms, where workpieces are held in place by suction cups or vacuum-sealed cavities: vacuum not reached, lost or not released; pump or vacuum switch input not configured. XX is the vacuum number; the parameters can be found under Tool Settings > Actuators and Presences, on the Vacuum tab.
T03000-0.XX - Vacuum - Vacuum timeout
What this means: with the vacuum valve open, the vacuum switch did not signal a vacuum within the Vacuum timeout set in the Timings unit (Equipment settings > Actuators and Presences, Vacuum tab; default 10 s). In the code, XX is the vacuum number (from 01 to 10).
Effect: Warning (yellow line): the workpiece is not being held; the valve remains open.
Probable causes:
- workpiece not correctly positioned (Vacuum not reached);
- damaged suction cups or hoses (Check holding, Pneumatic check);
- vacuum switch out of calibration or faulty (Check not carried out);
- time-out too short (Insufficient time).
How to resolve:
- Reposition the workpiece.
- Activate Vacuum in Machine Diagnostics > Manual Movements, Tool tab: the button must display a green ring.
- If the green halo does not appear: check the suction cups, hoses and vacuum switch (maintenance technician).
- If the vacuum is delayed: increase the Vacuum time-out.
Reset: this disappears automatically once the vacuum is achieved.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Vacuum not achieved
How to recognise it: when the vacuum is activated, the green ring around the Vacuum button does not appear.
Check:
- Check that the workpiece is securely held by the suction cups or in the cavity.
- Check the vacuum switch calibration (typical value −0.65 bar) and its LED.
- Activate Vacuum via Machine Diagnostics > Manual Movements, under the Tool tab, and check whether a vacuum is achieved.
Remedy: reposition the workpiece; calibrate or replace the vacuum switch (maintenance technician).
Check on withholding
How to recognise it: a vacuum is difficult to achieve, is lost shortly afterwards, or remains even after the valve is released.
Check:
- Check that the suction cups are undamaged, clean and not deformed.
- Check the vacuum lines and fittings: ensure no hoses are punctured, blocked or disconnected.
- Activate Vacuum and Blow from Machine Diagnostics > Manual Movements, under the Tools tab, whilst listening for any leaks.
Remedy: replace damaged suction cups or hoses and tighten the fittings (maintenance technician).
Check not carried out
How to identify this: the part is held in place but the vacuum switch does not signal a vacuum (LED off, no glow around Vacuum).
Check:
- Check the electrical connection and the vacuum switch LED.
- Check the calibration of the vacuum switch.
Remedy: Reconnect, calibrate or replace the vacuum switch (maintenance technician).
Not enough time
How to recognise it: the vacuum is achieved, but only after the Vacuum Timeout has expired.
Check:
- Select Empty from Machine Diagnostics > Manual Movements, under the Equipment tab, and estimate the time required.
- Compare this with the Empty Timeout in the Times unit (Equipment Settings > Actuators and Presences, Empties tab; default 10 s).
Remedy: increase the Vacuum Timeout, allowing for a margin, and save (Save changes); if the vacuum is taking longer than usual, first check for leaks and the pump (maintenance technician).
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T03001-0.XX - Vacuum - Invalid pump
What this means: the vacuum is associated with an invalid pump: the machine supports a maximum of 4 pumps and the assigned number is outside the valid range. This association is part of the machine’s vacuum configuration (Machine Settings > General Settings > Components), set by CEMAS. In the code, XX is the vacuum number (from 01 to 10).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The vacuum valve is closed.
Probable causes:
- Incorrect pump configuration (Incorrect configuration).
How to resolve:
- Check in Equipment Settings > Actuators and Presences, under the Vacuum tab, that the tool is set to use vacuum
XX. - If so, have the vacuum and pump configuration checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Incorrect configuration
How to identify it: the Invalid pump alarm appears as soon as the tool uses a vacuum.
Check:
- Note down the vacuum number (
XX) indicated in the alarm code. - Check under Equipment Settings > Actuators and Presences, in the Vacuums tab, that the tool is set to use that vacuum.
Remedy: the pump for each vacuum and the machines’ pumps are configured by CEMAS: contact CEMAS Elettra support (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T03002-0.XX – Vacuum – Vacuum not released
What this means: with the vacuum valve closed, the vacuum switch still signals a vacuum after 5 s (fixed value): the workpiece may not be released. In the code, XX is the vacuum number (from 01 to 10).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- workpiece jammed or insufficient blow-off (Workpiece not released);
- valve failing to close or blocked pipe (Check pneumatic system, Check retention);
- vacuum switch constantly active (Sensors not working).
How to resolve:
- Initiate Blow in Machine Diagnostics > Manual Movements, Tools tab: the part should detach and the Vacuum indicator should go out.
- If the workpiece remains attached: increase the Blow time (Equipment settings > Actuators and presences, Vacuum tab, Times unit) and check that it is not jammed.
- If it detaches but the vacuum remains indicated: check the valve and vacuum switch (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Check on withholding
How to recognise it: a vacuum is difficult to achieve, is lost shortly afterwards, or remains even after the valve is released.
Check:
- Check that the suction cups are undamaged, clean and not deformed.
- Check the vacuum lines and fittings: ensure no hoses are punctured, blocked or disconnected.
- Activate Vacuum and Blow from Machine Diagnostics > Manual Movements, under the Tools tab, whilst listening for any leaks.
Remedy: replace damaged suction cups or hoses and tighten the fittings (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Unreleased track
How to recognise it: after the blow, the part remains attached to the suction cups or in the cavity.
Check:
- Initiate Blow from Machine Diagnostics > Manual Movements, Tool tab, and observe whether the part detaches.
- Check the Blow time in the Timings unit (Tool settings > Actuators and presences, Vacuum tab).
- Check that the part is not jammed in its seat.
Remedy: increase the Blow time and save (Save changes); safely remove the part from the machine.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T03003-0.XX - Vacuum - Incorrect command address
What this means: a command associated with a vacuum (On and Off outputs in the Commands pop-up or external cycle commands) does not exist or is invalid, for example because it has been deleted. In the code, XX is the vacuum number (from 01 to 10).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The vacuum valve is closed.
Probable causes:
- command deleted or invalid (Reset commands).
How to resolve:
- Check the outputs in the Commands pop-up for the vacuum (Equipment Settings > Actuators and Presences, Vacuum tab, visible in the advanced view).
- Check the external commands in the vacuum pop-up (Equipment Settings > Cycle Settings, Input unit).
- Choose the correct command or Select signal if not required.
Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.
Reset the controls
How to recognise it: the alarm appears after deleting or modifying the tools’ input or output commands.
Check:
- Open the Commands pop-up for the vacuum (Equipment Settings > Actuators and Presences, Vacuum tab, visible in the advanced view) and check the On and Off outputs.
- Check the external commands in the Inputs unit of the vacuum pop-up (Tool Settings > Cycle Settings).
Remedy: select the commands again or Select Signal if they are not required, then save (Save Changes).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T03004-0.XX - Vacuum - Input vacuum not configured
What this means: the tool is using vacuum XX, which is present on the machine but for which the vacuum switch input has not been enabled: the vacuum cannot be controlled. The input is configured in the Tool tab under Machine Settings > General Settings > Components, a CEMAS setting. A vacuum that is not present on the machine does not trigger an alarm. In the code, XX is the vacuum number (from 01 to 10).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The vacuum valve is closed.
Probable causes:
- Vacuum switch input not configured (Set inputs);
- Tool using a vacuum not provided for on this machine.
How to resolve:
- Check in Equipment Settings > Actuators and Presences, under the Vacuum tab, that vacuum
XXis required; if it is not required, delete it and save. - If it is required, have the vacuum switch input configured (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Set up the inputs
How to recognise it: the ‘Vacuum input not configured’ alarm appears as soon as the tools use vacuum.
Check:
- Check in Equipment Settings > Actuators and Presences, under the Vacuum tab, that the tool is set to use vacuum
XX. - If it is not required, remove it from the tool and save.
Remedy: if the vacuum is required, the vacuum switch input must be configured in the Equipment tab under Machine Settings > General Settings > Components by a CEMAS technician.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T03005-0.XX – Vacuum – Vacuum loss
What this means: a vacuum was automatically established but was lost whilst the valve was still open. Control is suspended whilst the machine awaits loading or the start of the cycle. In the code, XX is the vacuum number (from 01 to 10).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The valve remains open.
Probable causes:
- workpiece displaced or detached (Object incorrectly positioned);
- leaks or damaged suction cups (Check grip, Pneumatic check);
- vacuum switch out of calibration (Sensors not working).
How to resolve:
- Reposition the workpiece.
- Select Vacuum in Machine Diagnostics > Manual Movements, Tools tab: the green ring must remain steady.
- If it goes out: check suction cups, fittings and vacuum switch (maintenance technician).
Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Check on withholding
How to recognise it: a vacuum is difficult to achieve, is lost shortly afterwards, or remains even after the valve is released.
Check:
- Check that the suction cups are undamaged, clean and not deformed.
- Check the vacuum lines and fittings: ensure no hoses are punctured, blocked or disconnected.
- Activate Vacuum and Blow from Machine Diagnostics > Manual Movements, under the Tools tab, whilst listening for any leaks.
Remedy: replace damaged suction cups or hoses and tighten the fittings (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Item in the wrong place
How to recognise this: the vacuum is lost during the cycle because the workpiece has moved or is not seated properly.
Check:
- Check that the workpiece is in its correct position and is resting on all the suction cups.
- Check that no movement of the tools displaces it during the cycle.
Remedy: reposition the workpiece; if it always shifts at the same point in the cycle, have the tools checked (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Control inputs
Alarms relating to tool input controls – the input signals (buttons, pedals, Smart Tool signals) used in the cycle. These are configured under Equipment Settings > Actuators and Presences, on the Input Controls tab, which is visible in the advanced view.
T04000-0.XX - Control inputs - Incorrect signal address
What this means: the input command does not have a valid signal: in Plug mode, the pin does not exist on the plug; in Smart Tool mode, the selected signal is invalid (Equipment Settings > Actuators and Presences, Input Commands tab, Signal unit). In the code, XX is the input command number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- invalid pin or signal (Reset commands);
- plug or Smart Tool different from those specified.
How to resolve:
- Select the command in Tool Settings > Actuators and Presences, under the Input Commands tab (visible in advanced view) and check the Mode.
- With Plug: assign the pin in the Input pop-up; with Smart Tool: select the signal from the Signal menu.
Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Reset the controls
How to recognise it: the input command does not have a valid pin or signal.
Check:
- Select the command in Equipment Settings > Actuators and Presence, under the Input Commands tab (visible in advanced view) and check the Mode of the Signal unit.
- With Plug: check the pin in the Input pop-up; with Smart Tool: check the selected signal.
Solution: assign a valid pin or signal, or delete the command if it is not needed, and save (Save changes).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Command outputs
Alarms for the tool output commands – the output signals sent to the tools used in the cycle. These are configured under Equipment Settings > Actuators and Presences, on the Output Commands tab, which is visible in the advanced view.
T05000-0.XX - Output signals - Incorrect signal address
What this means: with the Smart Tool connected, the output command has an unselected signal or one outside the range (1 to 20) (Equipment settings > Actuators and presences, Output commands tab, Signal unit). In the code, XX is the output command number (01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- invalid signal (Reset the commands).
How to resolve:
- Select the command in Equipment Settings > Actuators and Presences, Output Commands tab (visible in advanced view).
- Select the signal from the Signal menu or delete the command if it is not required.
Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.
Reset the controls
How to identify this: the output command does not have a valid signal from the Smart Tool.
Check:
- Select the command under Equipment Settings > Actuators and Presences, on the Output Commands tab (visible in the advanced view).
- Check the Signal menu: it must not display Select signal.
Remedy: select the correct signal, or delete the command if it is not needed, and save (Save changes).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Smart Tool
Smart Tool (intelligent tool) alarms: the tool has its own PLC that exchanges signals with the welding machine: no communication, PLC disconnected, incompatible versions.
Availability: Tool option: only available when a Smart Tool is loaded.
T06000-0.XX - Smart Tool - Communication alarm
What this means: the Smart Tool’s PLC is no longer exchanging data with the welding machine’s PLC.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- plug or cable disconnected (Smart Tool not connected);
- Smart Tool switched off or not configured (Smart Tool PLC not configured).
How to resolve:
- Check that the Smart Tool plug is connected and that the Smart Tool is powered up.
- Check the Smart Tool’s communication LEDs.
- If the connection is correct, have the Smart Tool’s configuration checked (by a CEMAS technician).
Recovery: the fault clears automatically when the condition no longer exists; the Reset is also sent to the Smart Tool.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: tool option: only available when a Smart Tool is loaded.
Smart Tool not connected
How to tell: the Smart Tool is not communicating: the communication LEDs are off and the Smart Tool System icon does not appear in the bottom bar.
Check:
- Check that the Smart Tool’s plug is fully inserted.
- Check the power supply and the Smart Tool’s LEDs.
- Check that the cable is not damaged.
*Remedy*: Reconnect or replace the cable (by a maintenance technician); if the Smart Tool is powered up and connected but is not communicating, see Smart Tool PLC not configured**.
Smart Tool PLC not configured
How to identify the problem: the Smart Tool is connected and powered but communication cannot be established.
Check:
- Check that the Smart Tool fitted is the one intended for the loaded tool.
- Note any error status indicated by the LEDs on the Smart Tool’s PLC.
Remedy: the Smart Tool’s PLC is configured by connecting directly to its PLC, not via the control panel: contact CEMAS Elettra S.r.l. support (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T06001-0.XX - Smart Tool - Offline
What this means: The welding machine’s PLC does not detect the connected Smart Tool.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.
Probable causes:
- plug or cable disconnected (Smart Tool not connected);
- Smart Tool not powered.
How to resolve:
- Plug the Smart Tool’s connector in fully and check that it is powered.
- Check that the communication LEDs light up.
Recovery: the fault clears automatically once the condition no longer exists; a Reset is also sent to the Smart Tool.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: tool option: only available when a Smart Tool is loaded.
Smart Tool not connected
How to tell: the Smart Tool is not communicating: the communication LEDs are off and the Smart Tool System icon does not appear in the bottom bar.
Check:
- Check that the Smart Tool’s plug is fully inserted.
- Check the power supply and the Smart Tool’s LEDs.
- Check that the cable is not damaged.
*Remedy*: Reconnect or replace the cable (by a maintenance technician); if the Smart Tool is powered up and connected but is not communicating, see Smart Tool PLC not configured**.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T06002-0.XX - Smart Tool - Unsupported version of SmartTool
What this means: the version of the Smart Tool programme is not supported by the welding machine’s software.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.
Probable causes:
- Smart Tool programme is not compatible (Smart Tool update).
How to resolve:
- Note down the PLC release in Machine diagnostics > Support.
- Request a Smart Tool update (CEMAS technician).
Resolution: the issue resolves itself once the condition no longer exists; the Reset is also sent to the Smart Tool.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: tool option: only available when a Smart Tool is loaded.
Smart Tool Update
How to recognise it: a ‘version not supported’ warning appears (for the Smart Tool or the machine).
Check:
- Note down the PLC release under Machine Diagnostics > Support.
- Note down the Smart Tool programme version, if indicated on the Smart Tool or in its documentation.
Remedy: request a software update for the machine or the Smart Tool from CEMAS Elettra support (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T06003-0.XX - Smart Tool - Machine version not supported
What this means: The Smart Tool does not accept the welding machine’s software version.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.
Possible causes:
- machine software is older than required (Smart Tool update).
How to resolve:
- Note down the PLC release in Machine diagnostics > Support.
- Request a machine or Smart Tool update (CEMAS technician).
Resolution: the issue resolves itself when the condition no longer exists; the Reset is also forwarded to the Smart Tool.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: tool option: only available when a Smart Tool is loaded.
Smart Tool Update
How to recognise it: a ‘version not supported’ warning appears (for the Smart Tool or the machine).
Check:
- Note down the PLC release under Machine Diagnostics > Support.
- Note down the Smart Tool programme version, if indicated on the Smart Tool or in its documentation.
Remedy: request a software update for the machine or the Smart Tool from CEMAS Elettra support (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Tool status
Alarms relating to the general status of the tools: parameters that have been modified but not saved; an identification code read from the plug that differs from that of the loaded tools; head or mirror codes that differ from those of the table; plus some internal summaries not displayed in the Alarm Monitor.
T07000-0.XX - Tool status - Presences
What this means: internal PLC summary, active when at least one of the tool presence indicators is in alarm.
Effect: alert not displayed in the Alarm Monitor: none in itself: the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.
T07001-0.XX – Tool status – Actuators
What this means: internal PLC summary, active when at least one of the tools’ actuators is in alarm.
Effect: notification not displayed in the Alarm Monitor: none in itself: the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.
T07002-0.XX - Tool status - Vacuum
What this means: internal PLC summary, active when at least one of the tools’ vacuums is in alarm.
Effect: alert not displayed in the Alarm Monitor: none in itself: the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.
T07003-0.XX - Tool status - Input controls
What this means: internal PLC summary, active when at least one of the tools’ input commands is in alarm.
Effect: a message not displayed in the Alarm Monitor: none in itself; the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.
T07004-0.XX – Tool status – Output commands
What this means: internal PLC summary, active when at least one of the tools’ output commands is in alarm.
Effect: a message not displayed in the Alarm Monitor: none in itself: the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.
T07005-0.XX - Tool status - Smart Tool
What this means: internal PLC summary, active when at least one of the tools is in alarm.
Effect: notification not displayed in the Alarm Monitor: none in itself: the alarms to be resolved are the specific ones listed in the Current Alarms tab on the Machine Status > Alarm Monitor page.
T07006-0.XX - Tool status - Changes to tools to be saved
What this means: the parameters for the loaded tools have been changed but not yet saved; the Save changes button appears in the top panel. This control is not active in Putting into service or Configuration mode.
Effect: Alarm (red line): the automatic cycle cannot be started.
Possible causes:
- Parameters have been changed in Tool settings (Save changes).
How to resolve:
- Check the changes and tap Save changes: this opens Tool Change > Product Selection, from where you can save.
- To undo the changes, reload the tools from the same page.
Resolution: the issue resolves itself after saving or reloading.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Save changes
How to recognise it: the Save changes button is located in the top bar.
Check:
- Tap Save changes: this opens Tool change > Product selection.
- Check that the changes are as intended.
Solution: save the parameters; to discard the changes, reload the tools from the same page.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
T07007-0.XX - Tool status - ID code error on tool shank
What this means: outside of the tool change cycle, the code read from the plug’s coding pins differs from that of the loaded tool: the tool fitted may not correspond to the parameters currently in use.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.
Probable causes:
- plug not fully inserted or dirty contacts (Check plug);
- tool replaced without performing a tool change;
- coding pins incorrectly wired.
How to resolve:
- Check that the tool fitted is the one indicated in the lower box; if it is different, perform a tool change.
- If it is the correct one: check the plug and the code read in Machine Diagnostics > PLC, under the Pin Decoding tab.
- If the code is incorrect: check the wiring of the coding pins (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Check the plug
How to identify the problem: the tool code read from the plug does not match the tool loaded.
Check:
- Check that the tool plug is fully inserted and that the contacts are clean.
- Read the code in Machine Diagnostics > PLC, under the Pin Decoding tab.
- Compare the wiring of the coding pins with the wiring diagram.
Remedy: reinsert the plug; correct the wiring of the encoding pins (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Machine Alarms
Machine Alarms relate to the welding machine: power supplies and utilities (air, electric panel, pumps, extraction), axes and drives, tooling interfaces on the head, table and mirrors, safety devices, automatic and tool change cycles, vibration generators, laser sources, infrared or hot plate heating, and cooling. The code begins with M and the text in Machine Status > Alarm Monitor begins with Machine, followed by the zone (Head, Table, Mirror, Right Mirror) when the alarm relates to a specific zone.
Many units exist only for certain technologies or with certain machine options: each entry indicates this in the Availability paragraph.
Pressure switch
Alarms from the pressure switch on the main compressed air line, which monitors the supply pressure to the pneumatic actuators of the machine and tools. This is configured under Machine Settings > General Settings > Components, on the Pressure Switch tab.
M01000-0.XX - Pressure switch - No air
What this means: once the emergency has been reset, the main line pressure switch does not signal the pressure for approximately 3 s (fixed value). The threshold is set on the pressure switch (usually 5 bar).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. Without air, the pneumatic actuators are not controlled.
Probable causes:
- mains air supply shut off or absent (No air in the system);
- filter regulator closed, faulty or set too low (Filter regulator not supplied with air);
- inlet solenoid valve not actuated (Pilot-operated solenoid coil);
- pressure switch out of calibration or faulty.
How to resolve:
- Check that the machine’s air valve is open and that the mains supply is under pressure.
- Read the pressure gauge on the regulating filter: if the pressure is below the threshold, adjust the filter (maintenance technician).
- If the pressure is correct, check the inlet solenoid valve and pressure switch (by a maintenance technician).
Reset: once the cause has been rectified, press Reset on the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the pressure switch is fitted (Machine settings > General settings > Components, Pressure switch tab), option configured by CEMAS.
No air in the system
How to identify it: the machine’s pressure gauge shows zero or very low pressure; the pneumatic actuators do not move.
Check:
- Check that the machine’s air supply valve is open.
- Check that the factory air supply network is pressurised and that the supply hose is connected.
Remedy: open the valve or restore the supply (maintenance technician or the plant’s compressed air service).
Filter regulator not charged with air
How to identify this: air is reaching the machine, but the pressure gauge downstream of the regulator filter indicates low pressure.
Check:
- Read the pressure gauge on the regulator filter.
- Check the setting and condition of the filter cartridge and drain any condensation.
Remedy: adjust the pressure, clean or replace the cartridge; if the regulator is faulty, replace it (by a maintenance technician).
Controlled electric coil
How to identify the fault: the air supply valve does not open: no pressure reaches the downstream side even when mains air is present.
Check:
- Check that the PLC is controlling the valve (output active in Machine Diagnostics > PLC, Card Monitoring tab).
- Check the LED on the solenoid connector for the controlled valve.
- Check the voltage across the solenoid and the wiring.
Remedy: replace the connector or solenoid; if the solenoid is energised but the valve does not open, replace the valve (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M01001-0.XX - Pressure switch - Safety inputs not present
What this means: the two-channel safety pressure switch is sending signals of an inconsistency: the two channels are out of sync for 500 ms, or the first channel is open whilst the emergency has been reset.
Effect: Alarm (red line): the machine switches to manual mode; automatic cycle and tool change remain blocked.
Probable causes:
- insufficient or unstable air pressure;
- one channel of the pressure switch faulty or disconnected;
- wiring between the two inputs broken.
How to resolve:
- Check the pressure and stability of the supply air.
- Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the two pressure switch inputs light up simultaneously.
- If only one input switches: check the wiring and the pressure switch (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the safety pressure switch is fitted (Machine settings > General settings > Components, Pressure switch tab), an option configured by CEMAS.
Air conditioner
Alarms for the electric panel air conditioners (up to three), which maintain the internal temperature of the panel within the limits specified for the components. These are configured under Machine Settings > General Settings > Components, on the Air Conditioners tab.
M02000-0.XX - Air conditioner - Alarm
What this means: The air conditioner in the electric panel is signaling its own alarm (alarm contact open), for example due to high temperature or a fault. The control is active whilst the emergency condition has been resolved. In the code, XX is the air conditioner number (from 01 to 03).
Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle. It remains stored.
Probable causes:
- fault or alarm in the air conditioner (Alarm code);
- clogged filters or high ambient temperature;
- control panel doors open.
How to resolve:
- Read the alarm code on the air conditioning unit’s display and consult the manual.
- Check that the control panel doors are closed and that the vents are not blocked.
- Clean the filters (by a maintenance technician).
Reset: once the cause has been rectified, press Reset on the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the air conditioner is fitted (Machine settings > General settings > Components, Air conditioners tab), option configured by CEMAS.
Alarm code
How to identify it: the component (e.g. air conditioner, heat exchanger, generator or UPS) displays an error code on its screen or via its LEDs.
Check:
- Read the code on the display or in the component’s diagnostics.
- Look up the meaning of the code in the component’s manual.
Remedy: carry out the actions indicated in the component manual (by a maintenance technician); if the error code persists, report it to CEMAS Elettra S.r.l. support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M02001-0.XX - Air conditioner - Breaker triggered
What this means: the circuit board’s air conditioning protection switch is open: the air conditioning unit is not receiving power. The control is active with the emergency mode reset. In the code, XX is the air conditioning unit number (from 01 to 03).
Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic cycle. It remains stored in memory. Without cooling, the control panel may overheat.
Probable causes:
- circuit breaker tripped due to overload or fault (Circuit breaker (thermal) tripped);
- cabinet doors open (Door closure);
- door closure sensor faulty (Door closure sensor function).
How to resolve:
- Check that the control panel doors are closed.
- Reset the air-conditioning circuit breaker and check that it does not trip again (maintenance technician).
- If it trips again, have the air-conditioning unit checked (maintenance technician).
Restoration: once the cause has been rectified, press Reset on the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the air conditioner is fitted (Machine settings > General settings > Components, Air conditioners tab), option configured by CEMAS.
Door closing
How to identify this: the doors of the electric panel are open or ajar.
Check:
- Visually check that all the panel doors are closed and locked.
Remedy: close the panel doors; if the doors are open, the panel’s cooling system will not function correctly.
Circuit breaker (thermal) has tripped
How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.
Check:
- Locate the component’s circuit breaker on the wiring diagram and check its position.
- Check that the thermal setting corresponds to the diagram.
- Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.
Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).
Door closure sensor function
How to identify the problem: the control cabinet doors are closed, but the machine detects them as open.
Troubleshooting:
- Check the position and fixing of the control cabinet door closure sensor.
- Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the sensor input changes state when the door is opened and closed.
Remedy: reposition or replace the sensor (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Electric panel thermostat
Alarms from the electric panel thermostats (up to three), which signal that the internal temperature of the panel exceeds the temperature set on the thermostat. These are configured under Machine settings > General settings > Components, on the Electric panel thermostat tab.
M03000-0.XX – Electric panel thermostat – Alarm
What this means: The thermostat in the electric panel is signaling an internal temperature higher than that set on the thermostat. The control is active with the operator’s safety devices reset. In the code, XX is the thermostat number (from 01 to 03).
Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle. It remains stored in memory. A high temperature may cause faults in the electronic components.
Probable causes:
- Insufficient cabinet cooling or a fault (Cooling system);
- Thermostat set too low or faulty (Thermostat setting);
- Cabinet doors open or high ambient temperature.
How to resolve:
- Check that the cabinet air conditioner or fans are working and that the filters are clean (maintenance technician).
- Check that the cabinet doors are closed.
- Check the temperature set on the thermostat (maintenance technician).
Reset: once the cause has been rectified, press Reset on the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the thermostat is fitted (Machine settings > General settings > Components, Electric panel thermostat tab), an option configured by CEMAS.
Cooling system
How to tell: the electric panel is hot and the air conditioner or fans are not blowing cool air.
Check:
- Check that the air conditioning or fans in the switchboard are switched on.
- Check the filters and ventilation grilles.
- Check for any alarms on the air conditioning display.
Remedy: clean or replace the filters; have the faulty cooling system repaired (by a maintenance technician).
Thermostat settings
How to identify the problem: the thermostat trips when the cabinet is at normal temperature.
Check:
- Check the temperature setting on the cabinet thermostat.
- Compare it with the value shown in the wiring diagram.
Remedy: adjust the thermostat to the correct value; if it tripped anyhow, replace it (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
IM device status
Alarms from the IM interface modules, which connect the PLC to the input and output cards. The status of the cards can be viewed under Machine Diagnostics > PLC, on the PLC Hardware tab.
M04000-0.XX - IM device status - Device not configured
What this means: the IM interface module that connects the PLC to the input and output cards is not configured. On laser machines, there are up to three modules (XX from 01 to 03); on other machines, only IM1 is present. The cards can be viewed under Machine Diagnostics > PLC, on the PLC Hardware tab.
Effect: Alarm (red line): with the IM1 module, the machine switches to manual mode; the automatic cycle and tool change remain blocked. For IM2 and IM3, this is merely a warning.
Probable causes:
- PLC configuration does not match the installed modules (Configure IM);
- module replaced with a different model.
How to resolve:
- Check the status of the module cards in Machine Diagnostics > PLC, under the PLC Hardware tab.
- If a module has been replaced, check that the model is identical (maintenance technician).
- Have the PLC configuration checked (CEMAS technician).
Reset: disappears automatically when the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Set up IM
How to identify the problem: the IM module appears as unconfigured even though it is installed and powered.
Check:
- Check the module’s cards in Machine Diagnostics > PLC, under the PLC Hardware tab.
- Check that the installed module is the same model as specified in the configuration.
Remedy: the PLC configuration can only be updated by CEMAS Elettra S.r.l. personnel: contact support (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M04001-0.XX - IM device status - Device not accessible
What this means: the PLC is unable to communicate with the IM interface module. As the module is unreachable, input diagnostics are suspended; therefore, the warning may not appear even if a fault is present: this status can be viewed under Machine Diagnostics > PLC, in the PLC Hardware tab.
Effect: Alarm (red line): with the IM1 module, the machine switches to manual mode; the automatic cycle and tool change remain blocked. For IM2 and IM3, this is merely an indication.
Probable causes:
- Network cable between the PLC and the module is disconnected or damaged (Connect IM);
- Module is not powered.
How to resolve:
- Check for error cards (red exclamation mark) in Machine Diagnostics > PLC, under the PLC Hardware tab.
- Check the module’s power supply and LEDs, and the network cable (maintenance technician).
Resolution: the error disappears automatically once the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.
Connect IM
How to identify the problem: the IM module is not communicating: network LEDs are off or red, and there are error messages for the cards on the PLC Hardware page.
Check:
- Check that the network cable between the PLC and the module is connected.
- Check the module’s power supply (power LEDs should be on).
Remedy: Reconnect or replace the cable; restore the power supply (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M04002-0.XX - IM device status - Hardware error
What this means: the IM interface module is signalling a hardware fault, either in the module itself or in a connected card. When the module is in fault mode, input diagnostics are suspended, so the fault message may not appear: the status can be checked under Machine Diagnostics > PLC, on the PLC Hardware tab.
Effect: Alarm (red line): with the IM1 module, the machine switches to manual mode; the automatic cycle and tool change remain blocked. For IM2 and IM3, this is merely a warning.
Probable causes:
- Faulty module or card, or not inserted correctly (Check hardware).
How to resolve:
- In Machine Diagnostics > PLC, on the PLC Hardware tab, identify the card marked with a red exclamation mark.
- Check that the card is fully inserted into its socket (maintenance technician).
- If the fault persists, replace the card with one of the same model (maintenance technician) and notify CEMAS.
Reset: the fault clears automatically once the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Check the hardware
How to identify it: an IM module card displays a red exclamation mark under Machine Diagnostics > PLC, on the PLC Hardware tab.
Check:
- Check that the card is fully inserted into its socket.
- Move the card to another free position to determine whether the card or the socket is faulty.
Remedy: replace the card or socket with components of the same model (maintenance technician) and notify CEMAS Elettra support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Time zone
Machine time alerts: time zone not set or PLC clock not synchronised. The time zone is set via Date and time in the bottom pane (Time zone pop-up).
M05000-0.XX - Time zone - Time zone not selected
What this means: the machine’s time zone is not set or is invalid: the date and time of recorded events (cycles, alarms) may be incorrect.
Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle.
Probable causes:
- Time zone not selected after installation or an update (Time zone setting).
How to resolve:
- Tap Date and time in the bottom panel (Time zone pop-up) and select the time zone for the installation location (users authorised to manage the machine or tools).
- Confirm and check that the time displayed is correct.
Resolution: the issue resolves itself once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Setting the time zone
How to recognise it: the date and time displayed in the bottom bar do not match the local time.
Check:
- Tap Date and time in the bottom frame (Time zone pop-up) and check the set time zone.
Solution: select the time zone for the installation location and confirm (users authorised to manage the machine or tools).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M05001-0.XX – Time zone – Time synchronisation error
What this means: with synchronisation monitoring enabled (CEMAS setting), the PLC’s clock has been out of sync for at least 1 hour. The time source (network server or operator panel) depends on the PLC’s configuration; the PLC does not adjust the time itself.
Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic cycle.
Probable causes:
- Time server unreachable or company network disconnected;
- Time zone not set (Time zone setting);
- Incorrect synchronisation configuration.
How to resolve:
- Check the time zone via Date and Time in the bottom pane (Time Zone pop-up).
- Check that the machine’s network cable is connected and that the company’s time server is active (customer’s IT department).
- If the network connection is correct, have the configuration checked (CEMAS technician).
Resolution: the error disappears automatically once the issue is resolved.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Setting the time zone
How to recognise it: the date and time displayed in the bottom bar do not match the local time.
Check:
- Tap Date and time in the bottom frame (Time zone pop-up) and check the set time zone.
Solution: select the time zone for the installation location and confirm (users authorised to manage the machine or tools).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Signal tower
Alarms from the machine’s stack light. This is configured under Machine Settings > General Settings > Components, on the Signal Column tab.
M06000-0.XX – Signal tower – Patlite communication error
What this means: The stack light is not communicating with the PLC via the network.
Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle. The stack light does not display the machine’s status.
Probable causes:
- the stack light’s network or power cable is disconnected (Stack light connection);
- the stack light is faulty (Stack light functionality).
How to resolve:
- Check that the signal tower is powered (indicator lights on at start-up).
- Check the signal tower’s mains cable and its connectors (maintenance technician).
- If the connection is correct, replace the tower (maintenance technician).
Resolution: the fault clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the stack light is fitted (Machine settings > General settings > Components, Signal column tab), an option configured by CEMAS.
Stack light functions
How to identify the problem: the turret is powered up and connected but does not switch on or communicate.
Check:
- Check the turret’s status LEDs.
- Temporarily replace the network cable with a working one.
Remedy: if the turret remains unresponsive, replace it (by a maintenance technician).
Stack light connection
How to recognise this: the turret is switched off or is not communicating following work carried out on the machine.
Check:
- Check the turret’s power cable.
- Check the network cable and its connectors.
Remedy: Reconnect or replace any damaged cables (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
General signal
General signal alarms: signals with a fixed function (clamp, alarm reset, cycle start, home position, pressure switch, presences, out-of-limit, external manual/automatic), often used to connect the welding machine to a production line or a robot. These are configured under Machine Settings > General Settings > Components, on the General Signals tab.
M07000-0.XX – General signal – Incorrect command address
What this means: the general signal XX is assigned to an input command that does not exist (number outside the range 1–20) or is not enabled, for example, one that has been deleted after assignment; the signal remains at its last value. XX: 01 Clamp, 02 External clamp, 03 Reset alarms, 04 Start cycle, 05 Start cycle external, 06 Home position, 07 Pressure switch, 08 LH presence, 09 RH presence, 10 Out of clearance, 11 external manual/automatic.
Effect: Alarm (red line): for signals 01 to 09, the machine switches to manual mode; the automatic cycle and tool change remain blocked. For 10 and 11, it is merely an indication.
Probable causes:
- Input command deleted or disabled after assignment (Reset command).
How to resolve:
- Check the command assigned to signal
XXin Machine Settings > General Settings > Components, under the General Signals tab. - Check in Machine Settings > General Settings > Components, under the Input Commands tab, that the command exists and is enabled.
- Correct the assignment (CEMAS technician).
Reset: stored: after correction, press Reset in the Alarm Monitor; if the cause remains, the fault will recur.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Reset command
How to recognise it: the alarm appears after modifying or deleting machine input commands.
Check:
- Check in Machine Settings > General Settings > Components, under the General Signals tab, the command assigned to the signal indicated by
XX. - Check in Machine Settings > General Settings > Components, under the Input Commands tab, that the command exists and is enabled.
Remedy: correct the assignment (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Suction
Warnings relating to the extractor fan for welding fumes. This is configured under Machine settings > General settings > Components, on the Extractor fan tab.
M08000-0.XX - Suction - Breaker triggered
What this means: the fume extractor’s safety switch is open.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked. The fume extraction is switched off.
Probable causes:
- motor overload or fault, blocked filters (Circuit breaker (thermal) tripped).
How to resolve:
- Check the condition of the extractor filters and clean or replace them (maintenance technician).
- Reset the circuit breaker and check that it does not trip again (maintenance technician).
- If it trips again, have the extractor motor checked (maintenance technician).
Restoration: once the cause has been rectified, press Reset on the Alarm Monitor. On machines with vibration, the alarm may remain active after pressing Reset: in this case, contact CEMAS Elettra support.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the extractor is fitted (Machine settings > General settings > Components, Extractor tab), an option configured by CEMAS.
Circuit breaker (thermal) has tripped
How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.
Check:
- Locate the component’s circuit breaker on the wiring diagram and check its position.
- Check that the thermal setting corresponds to the diagram.
- Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.
Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
VCU
Alarms from the VCU (Vibration Control Unit), the generator that controls the vibration of the head and communicates with the PLC via a serial link: communication, safety switch, readiness, vibration duration and amplitude, amplitude calibration.
The VCU parameters (maximum amplitude, tolerance, vibration time-out) are found under Machine Settings > General Settings > Tool Interfaces, VCU tab; the vibration can be tested via Machine Diagnostics > Machine Test, VCU tab; the results of the amplitude tests are found in Machine Diagnostics > Calibrations and Certifications, VCU tab.
Availability: only on vibration machines.
M09000-1.XX – Head – VCU – Transmission error
What this means: The PLC is unable to send data to the VCU via the serial line: the transmission fails or is not confirmed within 500 milliseconds (ms). Control is always active; fixed value.
Effect: Alarm (red line): the VCU is not ready, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode; the automatic cycle, tool change and VCU procedures are suspended.
Probable causes:
- VCU switched off or locked;
- serial cable disconnected or damaged;
- PLC serial module faulty.
How to resolve:
- Check that the VCU display is on and showing no errors; if not, check the power supply (maintenance technician).
- Check the TX and RX LEDs on the serial board in the control cabinet: they should be flashing; if one remains off, check the cable and connectors (maintenance technician).
- If the alarm recurs whilst the cable and VCU are in good working order, have the serial module checked (CEMAS technician).
Reset: the alarm clears automatically upon the first successful data exchange; then restart the cycle.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on vibration machines (all models 901, 902, 911, 912, 918, 950 and 999).
VCU ignition
How to identify the problem: the VCU (vibration generator) has a blank display or shows an error; the vibration does not start and communication alarms appear.
Check:
- Check that the VCU display is on: if it is off, check the switch and the VCU power supply in the control panel.
- If the display shows an error code, make a note of it.
- After switching it back on, wait approximately 20 seconds: the VCU start-up message should disappear.
Remedy: reset or restore the power supply (maintenance technician); if the VCU does not switch on or remains in error mode, report the code to the (CEMAS technician).
Check the message
How to identify it: the transmission or reception alarms persist even when the VCU is switched on.
Check:
- In the electric panel, check the LEDs on the PLC’s serial card: TX should flash when the PLC is transmitting, and RX when it is receiving.
- TX off: the PLC is not transmitting; this is a problem with the serial module. RX off whilst TX is active: the VCU is not responding or the cable is broken.
Remedy: if RX is off, check the cable and the VCU (maintenance technician); if TX is off, have the serial module and its configuration checked (CEMAS technician).
Check the connection
How to recognise it: no communication with the VCU or intermittent communication, sometimes following work on the control panel or machine vibrations.
Check:
- Check that the serial cable between the PLC and the VCU is plugged in and securely fastened at both ends.
- Check that the cable is not crushed, cut or has a disconnected shield.
Remedy: Reconnect or replace the serial cable (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09001-1.XX - Head - VCU - Reception error
What this means: The PLC does not receive a response from the VCU within 500 milliseconds (ms), or receives an error response. Control is always active; fixed value.
Effect: Alarm (red line): the VCU is not ready, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode; the automatic cycle, tool change and VCU procedures remain blocked.
Probable causes:
- VCU switched off or locked;
- serial cable disconnected or damaged;
- PLC serial module faulty.
How to resolve:
- Check that the VCU display is on and showing no errors; if not, check the power supply (maintenance technician).
- Check the TX and RX LEDs on the serial board in the control cabinet: they should be flashing; if one remains off, check the cable and connectors (maintenance technician).
- If the alarm recurs whilst the cable and VCU are in good working order, have the serial module checked (CEMAS technician).
Reset: the alarm clears automatically upon the first successful data exchange; then restart the cycle.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on vibration machines (all models 901, 902, 911, 912, 918, 950 and 999).
VCU ignition
How to identify the problem: the VCU (vibration generator) has a blank display or shows an error; the vibration does not start and communication alarms appear.
Check:
- Check that the VCU display is on: if it is off, check the switch and the VCU power supply in the control panel.
- If the display shows an error code, make a note of it.
- After switching it back on, wait approximately 20 seconds: the VCU start-up message should disappear.
Remedy: reset or restore the power supply (maintenance technician); if the VCU does not switch on or remains in error mode, report the code to the (CEMAS technician).
Check the message
How to identify it: the transmission or reception alarms persist even when the VCU is switched on.
Check:
- In the electric panel, check the LEDs on the PLC’s serial card: TX should flash when the PLC is transmitting, and RX when it is receiving.
- TX off: the PLC is not transmitting; this is a problem with the serial module. RX off whilst TX is active: the VCU is not responding or the cable is broken.
Remedy: if RX is off, check the cable and the VCU (maintenance technician); if TX is off, have the serial module and its configuration checked (CEMAS technician).
Check the connection
How to recognise it: no communication with the VCU or intermittent communication, sometimes following work on the control panel or machine vibrations.
Check:
- Check that the serial cable between the PLC and the VCU is plugged in and securely fastened at both ends.
- Check that the cable is not crushed, cut or has a disconnected shield.
Remedy: Reconnect or replace the serial cable (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09002-1.XX – Head – VCU – CRC Invalid
What this means: A response from the VCU fails the integrity check (CRC): the data has arrived corrupted. The check is carried out on every response.
Effect: Alarm (red line): the VCU is not ready, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode; the automatic cycle, tool change and VCU procedures remain blocked.
Probable causes:
- electromagnetic interference on the serial line;
- damaged serial cable, connectors or shielding.
How to resolve:
- Check that the serial cable is intact, securely screwed into the connectors, with the shielding connected and kept away from power cables (maintenance technician).
- Press Reset: if the alarm recurs frequently, replace the cable (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor (the reset is also sent to the VCU); then restart the cycle.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on vibration machines (all models 901, 902, 911, 912, 918, 950 and 999).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09003-1.XX – Head – VCU – Maximum amplitude not specified
What this means: The Maximum amplitude of the VCU (Machine settings > General settings > Tool interfaces, VCU tab) is zero or has not been set: without this reference, the vibration cannot be controlled. Configuration error; always check.
Effect: Alarm (red line): the VCU is not ready, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode; the automatic cycle, tool change and VCU procedures remain blocked.
Probable causes:
- VCU parameters not set following a VCU replacement or a parameter reset.
How to resolve:
- Check the Maximum amplitude under Machine settings > General settings > Tool interfaces, VCU tab: it must be greater than zero.
- If missing, have it set according to the machine’s specifications and have the calibration repeated (by a CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor (the reset is also sent to the VCU); then restart the cycle.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Edit amplitude limits
How to identify this: the Maximum amplitude under Machine settings > General settings > Tool interfaces, on the VCU tab, is zero or blank, for example following the replacement of the VCU or a parameter reset.
Check:
- Open Machine Settings > General Settings > Tool Interfaces, VCU tab, and note the Minimum amplitude and Maximum amplitude.
- Compare these with the machine data: the maximum amplitude must be greater than zero.
Remedy: set the correct values and repeat the amplitude calibration (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09004-1.XX – Head – VCU – Breaker triggered
What this means: The VCU’s automatic (thermal) switch is open. Check whether the input is enabled (Machine settings > General settings > Tool interfaces, VCU tab, Thermal); the alarm remains stored.
Effect: Alarm (red line): the VCU is not ready, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode; the automatic cycle, tool change and VCU procedures remain blocked. After resetting, the VCU returns to a ready state in approximately 20 seconds (s).
Probable causes:
- VCU overload or fault;
- thermal set point too low.
How to resolve:
- Check the VCU thermal fuse and its calibration in the control panel (maintenance technician).
- Reset it once only, wait 20 s and press Reset.
- If it trips again, do not reset it: have the VCU and head cables checked (CEMAS technician).
Recovery: once the cause has been rectified, press Reset in the Alarm Monitor (the reset is also sent to the VCU); then restart the cycle.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Circuit breaker (thermal) has tripped
How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.
Check:
- Locate the component’s circuit breaker on the wiring diagram and check its position.
- Check that the thermal setting corresponds to the diagram.
- Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.
Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09005-1.XX - Head - VCU - Generator not ready
What this means: The VCU does not give the ‘Ready’ signal even though the thermal valve has been closed for at least 20 seconds (s). Check whether the input is enabled (Machine settings > General settings > Tool interfaces, VCU tab, Ready); the alarm remains stored.
Effect: Alarm (red line): the VCU is not ready, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode; the automatic cycle, tool change and VCU procedures remain blocked.
Probable causes:
- VCU in internal alarm;
- ‘Ready’ signal cable disconnected.
How to resolve:
- Read and note down the alarm code on the VCU display.
- Switch the VCU off and on again, wait 20 seconds and press Reset (maintenance technician).
- If the VCU does not return to standby mode, report the code to support (CEMAS technician).
Restoration: once the cause has been rectified, press Reset in the Alarm Monitor (the reset is also sent to the VCU); then restart the cycle.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on vibration machines (all models 901, 902, 911, 912, 918, 950 and 999).
Alarm code
How to identify it: the component (e.g. air conditioner, heat exchanger, generator or UPS) displays an error code on its screen or via its LEDs.
Check:
- Read the code on the display or in the component’s diagnostics.
- Look up the meaning of the code in the component’s manual.
Remedy: carry out the actions indicated in the component manual (by a maintenance technician); if the error code persists, report it to CEMAS Elettra S.r.l. support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09006-1.XX - Head - VCU - Vibration timeout
What this means: The vibration command has remained active for longer than the VCU’s time-out (Machine settings > General settings > Tool interfaces, VCU tab; usually 10 seconds). This check applies during welding, in the test under Machine diagnostics > Machine test, VCU tab, and during calibration; the same value limits the maximum welding time for the tooling.
Effect: Alarm (red line): the VCU is not ready, so any welding in progress is interrupted (scrap piece) and the machine switches to Manual mode; the automatic cycle, tool change and VCU procedures remain blocked.
Probable causes:
- welding that does not reach the required depth (low force or amplitude);
- workpieces that do not fit properly and are not drawn in;
- CYCLE START button held down for too long during the test.
How to resolve:
- Check in the last cycle whether the depth has stopped increasing: if so, check the force, amplitude and end-of-phase settings in Tooling Settings > Welding Parameters.
- Check that the parts are as specified and fit without any play.
Reset: once the cause has been eliminated, press Reset in the Alarm Monitor (the reset is also sent to the VCU); then restart the cycle.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Check cycle settings
How to recognise it: the sound or vibration timeout occurs following changes to the cycle or when using new tools.
Check:
- Check in Tools Settings > Cycle Settings that the stages are in the correct sequence.
- Check that no stage causes the machine to wait whilst sound or vibration is active.
Remedy: correct the sequence of stages and save (operator authorised to access tool settings).
Inspection of components to be welded
How to recognise it: the vibration lasts for the maximum time but the welding depth increases little or not at all; the parts move together instead of dragging.
Check:
- Check that the parts loaded are those specified for the tool.
- Check that they fit snugly in the fixtures with no play: the part that is to vibrate must be dragged by the head.
Remedy: reject parts that are out of tolerance; if there is play in the fixtures, have them checked (by a maintenance technician).
Check welding limits
How to recognise this: the welding takes longer than expected and reaches the maximum time, for example because it does not reach the set depth or penetration.
Check:
- Check the Type of weld termination and the Time / Depth value in the phase table under Equipment Settings > Welding Parameters.
- Check the Upper limit for the Welding time in the Welding limits panel and compare it with the Results of the last welding cycle.
Remedy: correct the welding parameters or limits (operator authorised to adjust tool settings); the machine’s maximum times are configured by CEMAS.
Check welding parameters
How to recognise it: the welding depth increases slowly and the welding cycle reaches the maximum vibration time.
Check:
- Check the force, amplitude and end-of-phase condition of the welding phases under Equipment Settings > Welding Parameters.
- Compare the values with those from the last successful production run.
Remedy: correct the parameters in accordance with the process instructions (operator authorised to modify parameters).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09007-1.XX - Head - VCU - Calibration error
What this means: A warning is provided for an amplitude calibration error; calibration errors are indicated by Maximum amplitude cannot be reached. In current versions of the machine software, the warning is provided but is not triggered.
Effect: Alarm (red line): none.
If this appears: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Check collection
How to identify this: the amplitude returned by the VCU pick-up differs from that measured by the amplitude meter, or the calibration fails.
Check:
- In Machine Diagnostics > Calibrations and Certifications, on the VCU tab, compare the Pickup amplitude with the measured value.
- With the machine in a safe state, check that the pickup components are intact and that the magnet moves centred within the coil.
Remedy: reposition or replace the pickup (CEMAS technician).
Check the calibration instrument
How to recognise this: the amplitude meter shows an error on its display or the reading is unstable during calibration.
Check:
- Read any error code shown on the amplitude meter’s display and make a note of it.
- Check that the instrument is securely fixed and correctly aligned with the head.
Remedy: reposition the instrument and repeat the procedure; if an error code appears, contact support (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09008-1.XX – Head – VCU – Amplitude tolerance
What this means: With the VCU calibrated, during vibration the measured amplitude deviates from the required amplitude by more than the Vibration tolerance (typically 0.5 millimetres, mm) for longer than the monitoring time (typically 1.5 s), both of which can be found in Machine settings > General settings > Tool interfaces, under the VCU tab.
Effect: Alarm (red line): the VCU is not ready, so any welding in progress is interrupted (reject part) and the machine switches to Manual mode; the automatic cycle, tool change and VCU procedures remain blocked.
Probable causes:
- tools fitted incorrectly or loose screws;
- mechanical problems with the head;
- calibration no longer valid.
How to resolve:
- Check that the screws securing the tools to the vibrating plate are tight (maintenance technician).
- Run a test without the tools via Machine Diagnostics > Machine Test, VCU tab: a stable amplitude indicates a problem with the tools; otherwise, have the head inspected (CEMAS technician).
- Check the last calibration in Machine Diagnostics > Calibrations and Certifications, VCU tab; if necessary, have it repeated (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor (the reset is also sent to the VCU); then restart the cycle. Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Check operation under vacuum conditions
How to recognise it: the amplitude does not stabilise or does not reach the required value, and the head may make an unusual noise.
Check:
- Dismantle the upper assembly (maintenance technician).
- In Machine Diagnostics > Machine Test, on the VCU tab, set an amplitude, select On for Manual Vibration Enable and hold down START CYCLE.
- Regular noise and stable amplitude: the problem lies with the tools. Abnormal noise or unstable amplitude: the problem lies with the head.
Remedy: for the tools, inspect them and refit them, tightening the screws to the specified torque (maintenance technician); for the head, have it inspected (CEMAS technician).
Check the set tolerances
How to recognise it: the tolerance alarm appears with a stable amplitude close to the required value.
Check:
- Under Machine settings > General settings > Tool interfaces, on the VCU tab, read the Vibration tolerance (typical value 0.5 mm) and the associated monitoring time (typically 1.5 s).
- Compare this with the actual deviation observed in Machine Diagnostics > Machine Test, VCU tab.
Remedy: if the tolerance is too tight, have it corrected (by a CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09009-1.XX - Head - VCU - Maximum amplitude not achievable
What this means: During calibration, the calculated coefficient exceeds the acceptable range: the amplitude measured by the amplitude meter is too low compared to the Maximum amplitude (Machine settings > General settings > Tool interfaces, VCU tab). Checked only during calibration.
Effect: Alarm (red line): calibration is interrupted and the VCU remains unready; the machine automatically switches to Manual mode.
Probable causes:
- amplitude gauge incorrectly positioned;
- mechanical obstruction restricting the head’s movement;
- Maximum amplitude set too high for the head.
How to resolve:
- Check the position and fixing of the amplitude sensor (CEMAS technician).
- Run a test without tools via Machine Diagnostics > Machine Test, using the VCU card to rule out head-related issues.
- Check the Maximum amplitude and repeat the calibration (CEMAS technician).
Reset: once the cause has been rectified, perform a Reset in the Alarm Monitor (the reset is also sent to the VCU); then restart the cycle. Calibration must be repeated.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on vibration machines (all models 901, 902, 911, 912, 918, 950 and 999).
Check operation under vacuum conditions
How to recognise it: the amplitude does not stabilise or does not reach the required value, and the head may make an unusual noise.
Check:
- Dismantle the upper assembly (maintenance technician).
- In Machine Diagnostics > Machine Test, on the VCU tab, set an amplitude, select On for Manual Vibration Enable and hold down START CYCLE.
- Regular noise and stable amplitude: the problem lies with the tools. Abnormal noise or unstable amplitude: the problem lies with the head.
Remedy: for the tools, inspect them and refit them, tightening the screws to the specified torque (maintenance technician); for the head, have it inspected (CEMAS technician).
Perform calibration
How to recognise this: the actual amplitude does not match the set value, or in Machine Diagnostics > Calibrations and Certifications, under the VCU tab, the calibration status is shown as Not performed or Interrupted.
Check:
- Check the status and date of the last calibration under Machine Diagnostics > Calibrations and Certifications, VCU tab, Calibration tab.
- Perform the calibration via Machine settings > General settings > Tool interfaces, VCU tab, with the amplitude meter fitted and connected.
- Once complete, check that the result is OK.
Remedy: calibration must be carried out by CEMAS Elettra personnel or under their direct supervision.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09010-1.XX – Head – VCU – Uncalibrated
What this means: A successfully completed amplitude calibration is missing; the calibration is also lost when the system is initialised. The status can be found under Machine Diagnostics > Calibrations and Certifications, VCU tab, Calibration tab.
Effect: Warning (yellow line): the cycle can start, but the head does not vibrate during welding and the workpiece is rejected (maximum time exceeded or insufficient depth). In manual mode, vibration is only possible at a percentage power setting.
Probable causes:
- VCU, pick-up or head replaced;
- calibration interrupted or never carried out;
- system initialisation after calibration.
How to resolve:
- Check under Machine Diagnostics > Calibrations and Certifications, VCU tab, Calibration tab: Not performed or Interrupted confirms the cause.
- Run the calibration via Machine Settings > General Settings > Tool Interfaces, VCU tab, using the amplitude meter (CEMAS technician).
- Check that the result is OK.
Reset: disappears automatically once calibration is completed successfully.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Perform calibration
How to recognise this: the actual amplitude does not match the set value, or in Machine Diagnostics > Calibrations and Certifications, under the VCU tab, the calibration status is shown as Not performed or Interrupted.
Check:
- Check the status and date of the last calibration under Machine Diagnostics > Calibrations and Certifications, VCU tab, Calibration tab.
- Perform the calibration via Machine settings > General settings > Tool interfaces, VCU tab, with the amplitude meter fitted and connected.
- Once complete, check that the result is OK.
Remedy: calibration must be carried out by CEMAS Elettra personnel or under their direct supervision.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09011-1.XX – Head – VCU – Calibration in progress
What this means: The machine is performing a vibration amplitude calibration, initiated via Machine Settings > General Settings > Tool Interfaces, VCU tab, with the amplitude sensor measuring the actual amplitude.
Effect: Info (grey line): status indication. During the procedure, the automatic cycle and tool change cannot be initiated; an alarm from the VCU or the amplitude sensor will interrupt it.
How to resolve:
- Wait for the procedure to finish without interfering with the head.
- Check the result under Machine Diagnostics > Calibrations and Certifications, VCU tab.
Resolution: the message disappears automatically once the procedure is complete.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09012-1.XX – Head – VCU – Certification pending
What this means: The machine is carrying out vibration amplitude certification, initiated via Machine Settings > General Settings > Tool Interfaces, VCU tab, with the amplitude sensor measuring the actual amplitude.
Effect: Info (grey line): status indication. During this procedure, the automatic cycle and tool change cannot be initiated; an alarm from the VCU or the amplitude sensor will interrupt it.
How to resolve:
- Wait for the procedure to finish without interfering with the head.
- Check the result under Machine Diagnostics > Calibrations and Certifications, VCU tab.
Resolution: the message disappears automatically once the procedure is complete.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09013-1.XX – Head – VCU – Capability under development
What this means: The machine is performing the vibration amplitude capability test (Cmk), initiated via Machine Settings > General Settings > Tool Interfaces, VCU tab, with the amplitude gauge measuring the actual amplitude.
Effect: Info (grey line): status indication. During this procedure, the automatic cycle and tool change cannot be initiated; an alarm from the VCU or the amplitude sensor will interrupt it.
How to resolve:
- Wait for the procedure to finish without interfering with the head.
- Check the result under Machine Diagnostics > Calibrations and Certifications, VCU tab.
Resolution: the message disappears automatically once the procedure is complete.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M09014-1.XX - Head - VCU - VCU starting up
What this means: The VCU is starting up: the generator thermal cut-out has been closed for less than 20 seconds (s) or, if there is no thermal cut-out, less than 20 s have elapsed since power-up. Fixed value.
Effect: Info (grey line): status indication: the unit cannot be controlled whilst vibration is present.
How to resolve:
- Wait for approximately 20 s.
- If the message persists, check that the VCU thermal switch is closed and the generator is powered (maintenance technician).
Reset: the warning disappears automatically when the VCU is ready.
Applicability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
VCU Amplitude Meter
Alarms from the amplitude metre, the networked measuring instrument that detects the amplitude of the head’s vibration during VCU calibration, certification and capability testing. It is triggered only during these procedures: its alarms do not appear during production.
Availability: only on vibrating machines.
M10000-1.XX - Head - VCU Amplitude Meter - Transmission error
What this means: The PLC is unable to send data to the amplitude metre: the transmission fails or is not confirmed within 2 seconds (s). Checked only whilst the amplitude metre is active: during VCU calibration, certification and capability testing, and for approximately 2 minutes afterwards.
Effect: Alarm (red line): the calibration, certification or capability test in progress is interrupted; the machine automatically switches to Manual mode.
Probable causes:
- amplitude meter switched off or not powered;
- the network cable between the amplitude meter and the Ethernet switch is disconnected or damaged.
How to resolve:
- Check that the amplitude meter is switched on and that there are no errors on the display.
- Check the network cable and the port LED on the Ethernet switch; if it is off, replace the cable (by a maintenance technician).
- Repeat the procedure.
Resolution: the issue resolves itself when communication returns to normal (a Reset does not clear it); then repeat the procedure.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Check the connection
How to identify the problem: Alarms on the amplitude metre appear as soon as the calibration, certification or capability procedure begins.
Check:
- Check that the amplitude metre is switched on and powered up.
- Check that the network cable is connected to the instrument and the Ethernet switch, and that it is not damaged.
Remedy: reconnect or replace the cable, then repeat the procedure (by a maintenance technician).
Check the message
How to identify the problem: the amplitude metre is switched on but the PLC is not receiving the measurements.
Troubleshooting:
- Check that the LED on the Ethernet switch port to which the amplitude metre is connected is lit.
- If the LED is off whilst the cable is plugged in, try another port or another cable.
Remedy: re-establish the connection (maintenance technician); if the instrument has been replaced, have its network configuration checked (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M10001-1.XX - Head - VCU Amplitude Meter - Reception error
What this means: The PLC does not receive a response from the amplitude metre within 2 seconds (s). Checked only whilst the amplitude metre is active: during VCU calibration, certification and capability testing, and for approximately 2 minutes afterwards.
Effect: Alarm (red line): the calibration, certification or capability test in progress is interrupted; the machine automatically switches to Manual mode.
Probable causes:
- amplitude meter switched off or not powered;
- the network cable between the amplitude meter and the Ethernet switch is disconnected or damaged.
How to resolve:
- Check that the amplitude meter is switched on and that there are no errors on the display.
- Check the network cable and the port LED on the Ethernet switch; if it is off, replace the cable (by a maintenance technician).
- Repeat the procedure.
Resolution: the error disappears automatically when communication returns to normal (a Reset does not clear it); then repeat the procedure.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on vibration machines (all models 901, 902, 911, 912, 918, 950 and 999).
Check the connection
How to identify the problem: Alarms on the amplitude metre appear as soon as the calibration, certification or capability procedure begins.
Check:
- Check that the amplitude metre is switched on and powered up.
- Check that the network cable is connected to the instrument and the Ethernet switch, and that it is not damaged.
Remedy: reconnect or replace the cable, then repeat the procedure (by a maintenance technician).
Check the message
How to identify the problem: the amplitude metre is switched on but the PLC is not receiving the measurements.
Troubleshooting:
- Check that the LED on the Ethernet switch port to which the amplitude metre is connected is lit.
- If the LED is off whilst the cable is plugged in, try another port or another cable.
Remedy: re-establish the connection (maintenance technician); if the instrument has been replaced, have its network configuration checked (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M10002-1.XX - Head - VCU Amplitude Meter - Disconnected
What this means: The PLC was unable to connect to the amplitude metre within 1 second (s) of it being activated. This is only checked whilst the amplitude metre is active: during VCU calibration, certification and capability testing, and for approximately 2 minutes afterwards.
Effect: Alarm (red line): does not stop the machine, but prevents amplitude calibration from starting.
Probable causes:
- amplitude meter switched off or not powered;
- the network cable between the amplitude meter and the Ethernet switch is disconnected or damaged.
How to resolve:
- Check that the amplitude meter is switched on and that there are no errors on the display.
- Check the network cable and the port LED on the Ethernet switch; if it is off, replace the cable (by a maintenance technician).
- Repeat the procedure.
Recovery: A reset does not clear this error: it disappears when the amplitude meter is switched off (approximately 2 minutes after the procedure has finished).
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Check the connection
How to identify the problem: Alarms on the amplitude metre appear as soon as the calibration, certification or capability procedure begins.
Check:
- Check that the amplitude metre is switched on and powered up.
- Check that the network cable is connected to the instrument and the Ethernet switch, and that it is not damaged.
Remedy: reconnect or replace the cable, then repeat the procedure (by a maintenance technician).
Check the message
How to identify the problem: the amplitude metre is switched on but the PLC is not receiving the measurements.
Troubleshooting:
- Check that the LED on the Ethernet switch port to which the amplitude metre is connected is lit.
- If the LED is off whilst the cable is plugged in, try another port or another cable.
Remedy: re-establish the connection (maintenance technician); if the instrument has been replaced, have its network configuration checked (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Centering
Alarms relating to centerings – the pneumatic devices that center the tools on the head, table or faceplate: movements not completed within the expected time, inconsistent position sensors, simultaneous commands.
Centreing devices are configured under Machine Settings > General Settings > Tool Interfaces, in the zone tab, under the Centerings tab; they are operated manually via Tool Change > Tool Change, in the Manual tab > Centerings, whilst the machine is in tool change mode.
M11000-2.XX - Table - Centering - Forward movement timeout
What this means: Following the command to move to the forward position, the sensor for that table centering position did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Centerings tab (−1 disables the check). The centering mechanism only moves outside the automatic cycle, with the emergency stops released.
Effect: Alarm (red line): the valves de-energise and the device remains stationary where it is; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- movement obstructed by a mechanical obstruction;
- insufficient air pressure or valve failing to switch;
- forward position sensor out of calibration or faulty.
How to resolve:
- Initiate the movement from Tool Change > Tool Change, Manual tab > Centering (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
- If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
- If the movement is merely slow, have the Time-out checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if centering is present; option configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Move not completed
How to recognise this: the centering does not reach the commanded position, or it reaches it but the sensor does not light up.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out) and observe whether the stroke is completed.
- Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
- Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.
Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.
Not enough time
How to recognise it: the centering completes the movement, but with a delay compared to the Time out: the alarm is triggered even if the position is subsequently reached.
Check:
- Manually control the movement and measure how long it takes to reach the position.
- Compare the time with the Time out in Machine settings > General settings > Tool interfaces, zone tab, Centering tab.
Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M11001-2.XX - Table - Centering - Backward movement timeout
What this means: Following the command to move to the retraction position, the sensor for that table centering position did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Centerings tab (−1 disables the check). The centering mechanism only moves outside the automatic cycle, with the emergency stops released.
Effect: Alarm (red line): the valves de-energise and the device remains stationary where it is; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- movement obstructed by a mechanical obstruction;
- insufficient air pressure or valve failing to switch;
- rear position sensor out of calibration or faulty.
How to resolve:
- Initiate the movement from Tool Change > Tool Change, Manual tab > Centering (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
- If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
- If the movement is merely slow, have the Time-out checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if centering is present; option configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Move not completed
How to recognise it: the centering does not reach the commanded position, or it reaches it but the sensor does not light up.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out) and observe whether the stroke is completed.
- Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
- Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.
Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.
Not enough time
How to recognise it: the centering completes the movement, but with a delay compared to the Time out: the alarm is triggered even if the position is subsequently reached.
Check:
- Manually control the movement and measure how long it takes to reach the position.
- Compare the time with the Time out in Machine settings > General settings > Tool interfaces, zone tab, Centering tab.
Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M11002-2.XX - Table - Centering - Forward position not released
What this means: Following the command to move to the ‘back’ position, when the Time out expires, the ‘forward’ position sensor for the table centering is still active: either the device has not started, or the sensor remains active.
Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- device mechanically jammed;
- no air supply or valve failing to switch;
- forward position sensor always active or out of calibration.
How to resolve:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
- If the device moves but the forward position sensor LED remains lit, adjust or replace the sensor (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if centering is present; option configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Centering lock engaged
How to recognise it: the centering does not start when commanded or stops halfway through its stroke; the start position sensor remains lit.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out), whilst observing the device.
- With the machine in a safe state, check that nothing is obstructing the travel (residue, loose components).
Remedy: remove the obstruction and check the air supply and valve (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M11003-2.XX - Table - Centering - Rear position not released
What this means: Following the command to move forwards, when the Time-out expires, the sensor for the table’s rear centering position is still active: the device has not started, or the sensor remains on.
Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- device mechanically jammed;
- no air supply or valve failing to switch;
- rear position sensor always active or out of calibration.
How to resolve:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
- If the device moves but the reverse position sensor LED remains lit, adjust or replace the sensor (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if centering is present; option configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Centering lock engaged
How to recognise it: the centering does not start when commanded or stops halfway through its stroke; the start position sensor remains lit.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Centerings (In, Out), whilst observing the device.
- With the machine in a safe state, check that nothing is obstructing the travel (residue, loose components).
Remedy: remove the obstruction and check the air supply and valve (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M11004-2.XX - Table - Centering - External alarm
What this means: A warning is provided for an external table-centering alarm. In current versions of the machine software, the warning is provided but is not triggered.
Effect: Alarm (red line): none.
If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if centering is present; option configured by CEMAS.
M11005-2.XX - Table - Centering - Both position sensors
What this means: The forward and reverse position sensors for table centering are active at the same time: the position cannot be determined. Control is always active when the device is present.
Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- a faulty or short-circuited sensor, which is always active;
- sensors positioned so as to detect both positions;
- sensor inputs configured incorrectly.
How to resolve:
- With the device stopped, check under Machine Diagnostics > PLC, on the Card Monitoring tab, which of the two inputs is active for no reason.
- Control the device via Tool Change > Tool Change, Manual tab > Centering (In, Out): each sensor must light up only in its own position; reposition or replace the one that remains lit (maintenance technician).
- If the sensors are working, have the inputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Centering tab (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if centering is present; option configured by CEMAS.
Sensor positioning
How to identify this: the component’s two position sensors are active at the same time.
Check:
- Move the component to one position and check that only the LED for the corresponding sensor is lit.
- Repeat in the other position.
- Check that each sensor is securely fitted and detects only its own position.
Remedy: reposition or replace the sensor that remains active (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M11006-2.XX - Table - Centering - Both commands
What this means: The two valves controlling the table’s centering movement are being actuated simultaneously: either due to a manual command issued during a cycle movement, or because the outputs have been configured incorrectly.
Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- a manual command given at the same time as a cycle command;
- the same output assigned to both movements.
How to resolve:
- Press Reset and repeat the movement using only one command at a time.
- If the alarm reoccurs, have the valve outputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Centering tab (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if centering is present; option configured by CEMAS.
Reset the controls
How to recognise it: the component receives the two opposing commands simultaneously (for example, forwards and backwards).
Check:
- Check the outputs and commands assigned to the component under Machine Settings > General Settings > Tool Interfaces.
- Check that two different commands do not use the same output or the same signal.
Remedy: correct the configuration (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Actuator connector
Alarms relating to connectors – the actuators that engage and disengage the automatic connection plug between the welding machine and the tools: incomplete movements, inconsistent sensor readings, simultaneous commands, unlocking required whilst the plug is engaged.
The connectors are configured in Machine Settings > General Settings > Tool Interfaces, under the zone tab, Connectors tab; they are controlled manually via Tool Change > Tool Change, under the Manual tab > Connectors.
M12000-2.XX - Table - Actuator connector - Forward movement timeout
What this means: Following the command to move to the forward position, the sensor for that position on the table connector did not activate within the Time-out set in Machine Settings > General Settings > Tool Interfaces, Table tab, Connectors tab (−1 disables the check). The connector only moves during tool change, with the operator safety devices in place; typical time-out is 5 seconds (s). In the code, XX is the connector number (from 01 to 03).
Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- movement obstructed by a mechanical obstruction;
- insufficient air pressure or a valve that fails to switch;
- forward position sensor out of calibration or faulty.
How to resolve:
- Initiate the movement from Tool Change > Tool Change, Manual tab > Connectors (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
- If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
- If the movement is merely slow, have the Time-out checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the connector is present; option configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Move not completed
How to recognise it: the connector does not reach the commanded position, or it reaches it but the sensor does not light up.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) and observe whether the stroke is completed.
- Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
- Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.
Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.
Not enough time
How to recognise it: the connector completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.
Check:
- Manually control the movement and measure how long it takes to reach the position.
- Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, connectors tab.
Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M12001-2.XX - Table - Actuator connector - Backward movement timeout
What this means: Following the command to move to the retraction position, the sensor for that position on the table connector did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Connectors tab (−1 disables the check). The connector only moves during tool change, with the operator safety devices in place; typical time-out is 5 seconds (s). In the code, XX is the connector number (from 01 to 03).
Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- movement obstructed by a mechanical obstruction;
- insufficient air pressure or a valve that fails to switch;
- rear position sensor out of calibration or faulty.
How to resolve:
- Initiate the movement from Tool Change > Tool Change, Manual tab > Connectors (In, Out): if this does not work, check for obstructions and verify the air supply and valve (maintenance technician).
- If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
- If the movement is merely slow, have the Time-out checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the connector is present; option configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Move not completed
How to recognise it: the connector does not reach the commanded position, or it reaches it but the sensor does not light up.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) and observe whether the stroke is completed.
- Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
- Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.
Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.
Not enough time
How to recognise it: the connector completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.
Check:
- Manually control the movement and measure how long it takes to reach the position.
- Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, connectors tab.
Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M12002-2.XX - Table - Actuator connector - Forward position not released
What this means: Following the command to move to the reverse position, when the Timeout expires, the forward position sensor for the table connector is still active: either the device has not started, or the sensor remains active. In the code, XX is the connector number (from 01 to 03).
Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- device mechanically jammed;
- no air supply or valve failing to switch;
- forward position sensor always active or out of calibration.
How to resolve:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
- If the device moves but the forward position sensor LED remains lit, adjust or replace the sensor (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the connector is present; option configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Connection blocked
How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
- With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).
Remedy: remove the obstruction and check the air supply and valve (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M12003-2.XX - Table - Actuator connector - Reverse position not released
What this means: Following the command to move forwards, when the Time out expires, the sensor for the table’s reverse position is still active: either the device has not started, or the sensor remains active. In the code, XX is the connector number (from 01 to 03).
Effect: Alarm (red line): the valves de-energise and the device remains stationary where it is; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- device mechanically jammed;
- no air supply or valve failing to switch;
- ‘back’ position sensor constantly active or out of calibration.
How to resolve:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
- If the device moves but the reverse position sensor LED remains lit, adjust or replace the sensor (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the connector is fitted; option configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Connection blocked
How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
- With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).
Remedy: remove the obstruction and check the air supply and valve (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M12004-2.XX - Table - Actuator connector - External alarm
What this means: A message is provided for an external alarm relating to the table connector. In current versions of the machine software, the message is provided but is not triggered. In the code, XX is the connector number (from 01 to 03).
Effect: Alarm (red line): none.
If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the connector is present; option configured by CEMAS.
M12005-2.XX – Table – Actuator connector – Both position sensors
What this means: The forward and reverse position sensors for the table connector are active simultaneously: the position cannot be determined. Monitoring is always active when this device is present. In the code, XX is the connector number (from 01 to 03).
Effect: Alarm (red line): the valves de-energise and the device remains stationary; the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- a faulty or short-circuited sensor that is always active;
- sensors positioned so that they detect both positions;
- sensor inputs configured incorrectly.
How to resolve:
- With the device stopped, check under Machine Diagnostics > PLC, on the Card Monitoring tab, which of the two inputs is active for no reason.
- Control the device via Tool Change > Tool Change, Manual tab > Connectors (In, Out): each sensor should only light up in its own position; reposition or replace the one that remains lit (maintenance technician).
- If the sensors are working, have the inputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Connectors tab (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the connector is present; option configured by CEMAS.
Sensor positioning
How to identify this: the component’s two position sensors are active at the same time.
Check:
- Move the component to one position and check that only the LED for the corresponding sensor is lit.
- Repeat in the other position.
- Check that each sensor is securely fitted and detects only its own position.
Remedy: reposition or replace the sensor that remains active (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M12006-2.XX - Table - Actuator connector - Both commands
What this means: The two motion valves of the table connector are being actuated simultaneously: either due to a manual command issued during a cycle movement, or because the outputs have been configured incorrectly. In the code, XX is the connector number (from 01 to 03).
Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- a manual command issued simultaneously with a cycle command;
- the same output assigned to both movements.
How to resolve:
- Press Reset and repeat the movement using only one command at a time.
- If the alarm reoccurs, have the valve outputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Connectors tab (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
Availability: machine option: appears if the connector is present; option configured by CEMAS.
Reset the controls
How to identify it: the Both commands alarm reoccurs even when the connector is activated just once.
Check:
- Press Reset and repeat only one command at a time, whilst no cycle is in progress.
- If the alarm returns, check that the two contactor valves are assigned to different outputs in Machine Settings > General Settings > Tool Interfaces, under the zone tab, in the Connectors tab.
Remedy: correct the output configuration (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M12007-2.XX - Table - Actuator connector - Pressure switch
What this means: A warning is provided for the pressure switch on the table’s automatic connection plug. In current versions of the machine software, the warning is provided but is not activated. In the code, XX is the connector number (from 01 to 03).
*Effect*: alert not displayed in the Alarm Monitor**: none.
If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the connector is present; option configured by CEMAS.
Check the pressure switch
How to identify the problem: the pressure switch on the connection plug does not confirm the pressure when the connector is closed.
Check:
- Check that the pressure switch LED lights up when pressure is present and that its input is active in Machine Diagnostics > PLC, under the Card Monitoring tab.
- Check the calibration using the adjustment screw.
Remedy: adjust or replace the pressure switch (maintenance technician).
Check the solenoid valve
How to identify the fault: air does not reach the automatic connection plug when the connector is engaged.
Check:
- Check that the solenoid valve coil is receiving the signal (LED lit).
- Check that the valve switches and that there is pressure downstream.
Remedy: replace the faulty coil or valve (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M12008-2.XX - Table - Actuator connector - Not in the ‘back’ position
What this means: A request has been made to release the tool on the table (clamped in the rest position) whilst the connector is still engaged: before releasing the tool, the connector must be returned to its original position. The alarm is stored. In the code, XX is the connector number (from 01 to 03).
Effect: Alarm (red line): the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain locked.
Probable causes:
- manual sequence carried out in the wrong order;
- connector locked in the ‘forward’ position;
- ‘reverse’ position sensor out of calibration or faulty.
How to resolve:
- Move the connector back via Tool Change > Tool Change, Manual tab > Connectors (In, Out) and check that the reverse position sensor LED lights up.
- If the connector does not move, remove the obstruction and check the air supply and valve (maintenance technician).
- Press Reset and repeat the release procedure.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the connector is present; option configured by CEMAS.
Assembly of tools
How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.
Check:
- Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
- Check that the centerings fit into their sockets and that the interface plate is in the correct position.
- Repeat the loading of the tools from the tool change.
Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Connection blocked
How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
- With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).
Remedy: remove the obstruction and check the air supply and valve (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M12009-2.XX - Table - Actuator connector - Not in the forward position
What this means: An alarm is programmed for when the table is not in the forward position. In current versions of the machine software, the alarm is programmed but is not triggered. In the code, XX is the connector number (from 01 to 03).
Effect: Alarm (red line): none.
If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the connector is present; option configured by CEMAS.
Assembly of tools
How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.
Check:
- Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
- Check that the centerings fit into their sockets and that the interface plate is in the correct position.
- Repeat the loading of the tools from the tool change.
Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).
Check inserts
How to recognise it: the connector cannot be fully inserted: the plug on the tool does not fit into the socket on the welding machine.
Check:
- With the machine switched off and secured, compare the inserts fitted to the welding machine’s socket with those on the tool’s plug.
- Check that there are no bent contacts or foreign objects.
Remedy: reposition the inserts so that they align correctly (maintenance technician).
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Connection blocked
How to recognise it: the connector does not start when commanded or stops halfway through its stroke; the position sensor remains lit.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Connectors (In, Out) whilst observing the device.
- With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).
Remedy: remove the obstruction and check the air supply and valve (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Clamp
Alarms relating to clamps – the devices that secure the tools to the head, table or spindle: incomplete movements, inconsistent sensor readings, interlock pressure not reached, invalid pump or safety inputs, or movements requested whilst the clamp is in the wrong position.
Clamps are configured under Machine Settings > General Settings > Tool Interfaces, in the zone tab, under the Clamp tab; they are operated manually via Tool Change > Tool Change, in the Manual tab > Clamps.
M14000-2.XX - Table - Clamp - Idle movement timeout
What this means: Following the command to move to the rest position, the sensor for that position of the table clamp did not activate within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamping tab (−1 deactivates the check). The clamp moves during tool change or, in manual mode, during repositioning.
Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- movement obstructed by a mechanical obstruction;
- insufficient air pressure or a valve that fails to switch;
- rest position sensor out of calibration or faulty.
How to resolve:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest): if this does not occur, check for obstructions and verify the air supply and valve (maintenance technician).
- If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
- If the movement is merely slow, have the Time-out checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the clamp is present; option configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Move not completed
How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.
Check:
- Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
- Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
- Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.
Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.
Not enough time
How to recognise it: the clamp completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.
Check:
- Manually control the movement and measure how long it takes to reach the position.
- Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, Clamp tab.
Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M14001-2.XX - Table - Clamp - Work movement timeout
What this means: Following the command to move to the working position, the sensor for that position of the table clamp did not activate within the Time-out set in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamping tab (−1 deactivates the check). The clamp moves during tool change or, in manual mode, during repositioning.
Effect: Alarm (red line): the valves de-energise and the device remains stationary where it is; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- movement obstructed by a mechanical obstruction;
- insufficient air pressure or a valve that fails to switch;
- work position sensor out of calibration or faulty.
How to resolve:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest): if this does not occur, check for obstructions and verify the air supply and valve (maintenance technician).
- If the movement reaches the end of its travel, check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace the sensor (maintenance technician).
- If the movement is merely slow, have the Time-out checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the clamp is present; option configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Move not completed
How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.
Check:
- Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
- Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
- Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.
Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.
Not enough time
How to recognise it: the clamp completes the movement, but after the Time out: the alarm is triggered even if the position is subsequently reached.
Check:
- Manually control the movement and measure how long it takes to reach the position.
- Compare the time with the Time out in Machine Settings > General Settings > Tool Interfaces, zone tab, Clamp tab.
Remedy: if the movement is smooth but slow, increase the Time-out (CEMAS technician); if it is slower than usual, check the air supply and friction (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M14002-2.XX - Table - Clamp - Rest position not released
What this means: After the command to move to the working position, when the Time out expires, the sensor for the table clamp’s rest position is still active: the device has not started, or the sensor remains on.
Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- device mechanically jammed;
- no air supply or valve failing to switch;
- rest position sensor constantly active or out of calibration.
How to resolve:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
- If the device moves but the rest position sensor LED remains lit, adjust or replace the sensor (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the clamp is active; this option is configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Clamp locked
How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
- With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).
Remedy: remove the obstruction and check the air supply and valve (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M14003-2.XX - Table - Clamp - Work position not released
What this means: Following the command to return to the rest position, once the Time-out has elapsed, the sensor for the table clamp working position is still active: the device has not started, or the sensor remains on.
Effect: Alarm (red line): the valves de-energise and the device remains stationary in its current position; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- device mechanically jammed;
- no air supply or valve failing to switch;
- working position sensor constantly active or out of calibration.
How to resolve:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) whilst observing the device: if it does not start, remove the obstruction and check the air supply and valve (maintenance technician).
- If the device moves but the working position sensor LED remains lit, adjust or replace the sensor (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the clamp is active; this option is configured by CEMAS.
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Clamp locked
How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
- With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).
Remedy: remove the obstruction and check the air supply and valve (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M14004-2.XX - Table - Clamp - External alarm
What this means: A message is provided for an external table clamp alarm. In current versions of the machine software, the message is provided but is not triggered.
Effect: Alarm (red line): none.
If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the clamp is present; option configured by CEMAS.
M14005-2.XX - Table - Clamp - Both position sensors
What this means: The sensors for the table clamp’s rest and working positions are active simultaneously: the position cannot be determined. Monitoring is always active when the device is present.
Effect: Alarm (red line): the valves de-energise and the device remains stationary; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- a faulty or short-circuited sensor, which is always active;
- sensors positioned so as to detect both positions;
- sensor inputs configured incorrectly.
How to resolve:
- With the device stopped, check under Machine Diagnostics > PLC, on the Card Monitoring tab, which of the two inputs is active for no reason.
- Operate the device via Tool Change > Tool Change, Manual tab > Clamps (Work, Rest): each sensor must light up only in its own position; reposition or replace the one that remains lit (maintenance technician).
- If the sensors are working, have the inputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamp tab (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the clamp is present; option configured by CEMAS.
Sensor positioning
How to identify this: the component’s two position sensors are active at the same time.
Check:
- Move the component to one position and check that only the LED for the corresponding sensor is lit.
- Repeat in the other position.
- Check that each sensor is securely fitted and detects only its own position.
Remedy: reposition or replace the sensor that remains active (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M14006-2.XX - Table - Clamp - Both commands
What this means: The two valves controlling the table clamp mechanism are being actuated simultaneously: either due to a manual command issued during a cycle movement, or because the outputs have been configured incorrectly.
Effect: Alarm (red line): the valves de-energise and the device comes to a standstill; the machine switches to manual mode (welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- a manual command given at the same time as a cycle command;
- the same output assigned to both movements.
How to resolve:
- Press Reset and repeat the movement using only one command at a time.
- If the alarm reoccurs, have the valve outputs checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamp tab (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
Availability: machine option: appears if the clamp is active; option configured by CEMAS.
Reset the controls
How to identify it: the Both commands alarm reoccurs even when the clamp is commanded just once.
Check:
- Press Reset and repeat only one command at a time, whilst no cycle is in progress.
- If the alarm returns, check that the two clamping valves are assigned to different outputs in Machine Settings > General Settings > Tool Interfaces, under the zone tab, in the Clamp tab.
Remedy: correct the output configuration (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M14007-2.XX - Table - Clamp - Not in the rest position
What this means: Without any tools, the table axis moves whilst the table clamp is not in the rest position: the clamp may cause an impact. The alarm is stored.
Effect: Alarm (red line): the machine switches to manual mode (welding in progress results in a scrap piece); automatic cycle and tool change remain blocked.
Probable causes:
- clamp left in the ‘working’ position after tool unloading;
- clamp stuck halfway through its stroke;
- rest position sensor out of calibration or faulty.
How to resolve:
- Set the clamp to rest mode via Tool Change > Tool Change, Manual tab > Clamps (Operating, Rest) and check the rest position sensor LED.
- If it does not move or the sensor does not light up, check the air supply, valve and sensor (maintenance technician).
- Press Reset and repeat the axis movement.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the clamp is present; option configured by CEMAS.
Assembly of tools
How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.
Check:
- Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
- Check that the centerings fit into their sockets and that the interface plate is in the correct position.
- Repeat the loading of the tools from the tool change.
Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Clamp locked
How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
- With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).
Remedy: remove the obstruction and check the air supply and valve (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M14008-2.XX - Table - Clamp - Not in working position
What this means: A command has been issued to engage the connectors, or to move the machine whilst the tools are loaded, whilst the table clamp is not in the working position: the tools may not be secured. The alarm is stored.
Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- clamp not closed before proceeding;
- clamp stuck halfway through its stroke;
- working position sensor out of calibration or faulty.
How to resolve:
- Set the clamp to ‘Operating’ via Tool Change > Tool Change, Manual tab > Clamps (Operating, Rest) and check the operating sensor LED.
- Check that the tool is correctly positioned and that nothing is preventing it from closing (maintenance technician).
- Press Reset and repeat the command.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the clamp is present; option configured by CEMAS.
Assembly of tools
How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.
Check:
- Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
- Check that the centerings fit into their sockets and that the interface plate is in the correct position.
- Repeat the loading of the tools from the tool change.
Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Clamp locked
How to recognise it: the clamp does not start when activated or stops halfway through its stroke; the position sensor remains lit.
Check:
- Initiate the movement via Tool Change > Tool Change, Manual tab > Locks (Work, Rest), whilst observing the device.
- With the machine in a safe state, check that nothing is obstructing the stroke (residue, loose components).
Remedy: remove the obstruction and check the air supply and valve (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M14009-2.XX - Table - Clamp - Circuit 1 pressure timeout
What this means: The interlock valve for circuit 1 of the table clamp system is activated, but the pressure switch for circuit 1 does not confirm the pressure within the Interlock Pressure Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamping tab.
Effect: Alarm (red line): the interlock valves and the pump remain active; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- Insufficient supply pressure or the pump failing to reach it;
- Leaks in the clamp circuit;
- Pressure switch out of calibration or faulty;
- Time-out set too short.
How to resolve:
- Check the supply pressure and ensure there are no leaks in the circuit (maintenance technician).
- Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the pressure switch input activates when the clamp is in operation; if not, adjust or replace it (maintenance technician).
- If the pressure is present but delayed, have the Time-out checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the clamp is active; option configured by CEMAS.
Move not completed
How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.
Check:
- Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
- Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
- Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.
Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.
Insufficient time for inspection
How to recognise it: the interlock pressure is reached, but after the Interlock pressure time-out: the alarm appears even if the pressure switch subsequently confirms.
Check:
- With the clamp in operation, check under Machine Diagnostics > PLC, Card Monitoring tab, to see how long it takes for the pressure switch input to activate.
- Compare this time with the Time-out for Interlock pressure in Machine settings > General settings > Tool interfaces, under the zone tab, Clamp tab.
Remedy: if the pressure rises steadily but slowly, increase the Time-out (CEMAS technician); if it is slower than usual, check the pump and for leaks (maintenance technician).
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M14010-2.XX - Table - Clamp - Circuit 2 pressure timeout
What this means: The interlock valve for circuit 2 of the table clamp system is activated, but the pressure switch for circuit 2 does not confirm that the pressure is within the Interlock Pressure Timeout set in Machine Settings > General Settings > Tool Interfaces, under the Table tab and the Clamping tab. Circuit 2 is only controlled if its valve and pressure switch are enabled.
Effect: Alarm (red line): the interlock valves and the pump remain active; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- insufficient supply pressure or the pump failing to reach it;
- leaks in the clamp circuit;
- pressure switch out of calibration or faulty;
- Time-out set too short.
How to resolve:
- Check the supply pressure and ensure there are no leaks in the circuit (maintenance technician).
- Check in Machine Diagnostics > PLC, under the Card Monitoring tab, that the pressure switch input activates when the clamp is in operation; if not, adjust or replace it (maintenance technician).
- If the pressure is present but delayed, have the Time-out checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the clamp is active; option configured by CEMAS.
Move not completed
How to recognise it: the clamp does not reach the commanded position, or it reaches it but the sensor does not light up.
Check:
- Initiate the movement from Tool Change > Tool Change, Manual tab > Clamps (Work, Rest) and observe whether the stroke is completed.
- Stroke complete: check the sensor LED and its input in Machine Diagnostics > PLC, Card Monitoring tab.
- Stroke incomplete: check for mechanical obstructions and inspect the air supply and valve.
Remedy: adjust or replace the sensor, remove the obstruction (maintenance technician); for incorrectly configured inputs, contact a CEMAS technician.
Insufficient time for inspection
How to recognise it: the interlock pressure is reached, but after the Interlock pressure time-out: the alarm appears even if the pressure switch subsequently confirms.
Check:
- With the clamp in operation, check under Machine Diagnostics > PLC, Card Monitoring tab, to see how long it takes for the pressure switch input to activate.
- Compare this time with the Time-out for Interlock pressure in Machine settings > General settings > Tool interfaces, under the zone tab, Clamp tab.
Remedy: if the pressure rises steadily but slowly, increase the Time-out (CEMAS technician); if it is slower than usual, check the pump and for leaks (maintenance technician).
Pneumatic tyre pressure check
How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.
Check:
- Check the supply air pressure on the machine’s pressure gauge.
- Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
- Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.
Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M14011-2.XX - Table - Clamp - Invalid pump
What this means: The pump associated with the table clamp has an invalid number: the machine manages pumps 1 to 4. Configuration error; always check.
Effect: Alarm (red line): the clamp cannot be activated; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- Incorrect pump number set in the clamp configuration.
How to resolve:
- Have the pump assigned to the clamp checked in Machine Settings > General Settings > Tool Interfaces, Table tab, Clamp tab, and the pumps configured in Machine Settings > General Settings > Components (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if a clamp is present; this option is configured by CEMAS.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M14012-2.XX - Table - Clamp - Safety inputs not present
What this means: With the operator safety devices in place, the two channels of the table clamp pressure switch’s safety inputs are inconsistent: for 500 milliseconds (ms), an interlock valve is activated without pressure confirmation from the first channel, or the two channels are out of sync. Checked only if the safety inputs are configured; remains stored.
Effect: Alarm (red line): the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- Insufficient interlock pressure;
- One of the two safety pressure switches is faulty, out of calibration or disconnected.
How to resolve:
- Check the two safety inputs for the ‘Clamp in operation’ status under Machine Diagnostics > PLC, Card Monitoring tab: both must be active.
- If one remains off, check the pressure, wiring and calibration of the relevant pressure switch (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the clamp is present; option configured by CEMAS.
Axis
Alarms relating to the axes that move the table, head and mirror: drives, brakes, switches, overtravel, referencing, positions, the machine’s load cell, force-related procedures and, on hydraulic vibration machines, the table’s hydraulic power unit. The alarm message indicates the area (Head, Table, Plate).
The status of the motors can be viewed under Machine Diagnostics > Motor Status; manual movements are controlled via Machine Diagnostics > Manual Movements, Machine tab.
M15300-2.XX - Table - Axis calibration and certification - Calibration timeout
What this means: the table axis force calibration procedure did not complete within the maximum time limit (default 600 seconds (s), configured by CEMAS).
Effect: Alarm (red line). The procedure is interrupted (status Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.
Probable causes:
- force failing to stabilise at the required values (Axis calibration and certification settings);
- external load cell incorrectly positioned or axis obstructed;
- procedure left on hold (Calibration not completed).
How to resolve:
- Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms (CEMAS technician).
- Check that nothing is obstructing the axis and that there are no other active alarms.
- Repeat the procedure (CEMAS technician) and check the result under Machine Diagnostics > Calibrations and Certifications.
Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.
Axis calibration and certification settings
How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.
Check:
- Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
- Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).
Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.
Calibration not completed
How to identify this: under Machine Diagnostics > Calibrations and Certifications, Table tab > Calibration, the result is Interrupted or Not performed.
Check:
- Check the date and result of the last calibration.
- Check Machine Status > Alarm Monitor for the alarms that caused the calibration to be interrupted.
Remedy: once the causes have been rectified, the calibration must be repeated by CEMAS Elettra personnel or under their supervision.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15000-2.XX - Table - Axis - Axis alarm
What this means: summary message: the table axis has an alarm listed in its details (drive, switches, overtravel).
Effect: The signal is not displayed in the Alarm Monitor. Specific alarms relating to the table axis details (M151xx-2.XX) appear: follow the instructions for those entries.
Axis status coding
How to recognise it: the axis is stationary in alarm mode and its drive signals an abnormal status.
Check:
- In Machine Diagnostics > Motor Status, open the axis card and tap the i icon: the diagnostics pop-up displays the drive’s current statuses, errors and warnings.
- Make a note of the statuses and errors displayed.
Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the fault persists, report the noted data to CEMAS Elettra support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15100-2.XX - Table - Beam - External alarm
What this means: this warning (external table axis alarm) is provided for in the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.
Effect: Alarm (red line). No effect on the machine.
How to resolve:
- If the warning appears, note down the full code, the time and the machine’s operating conditions.
- Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.
M15101-2.XX – Table – Circuit board – Breaker triggered
What this means: one of the circuit breakers (logic thermal or power thermal) supplying power to the table axis drive has tripped.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- circuit breaker tripped due to overload or short circuit on the motor, cable or drive (entry Circuit breaker (thermal) tripped);
- circuit breaker opened for maintenance and not reset;
- auxiliary contact or input wiring disconnected.
How to resolve:
- In the electric panel, reset the circuit breaker (logic thermal or power thermal) for the table axis (electrical maintenance technician).
- If it trips again, do not persist: check for a short circuit or overload in the cables, motor and drive.
- If the circuit breaker is closed but the alarm persists, check the auxiliary contact and wiring.
Reset: it clears automatically when the circuit breaker is re-closed; other drive alarms are cleared using Reset.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Circuit breaker (thermal) has tripped
How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.
Check:
- Locate the component’s circuit breaker on the wiring diagram and check its position.
- Check that the thermal setting corresponds to the diagram.
- Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.
Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15301-2.XX - Table - Axis calibration and certification - Certification timeout
What this means: the table axis force certification procedure has not been completed within the maximum time limit (default 900 seconds (s), configured by CEMAS).
Effect: Alarm (red line). The procedure is interrupted (status Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.
Probable causes:
- force failing to stabilise at the required values (Axis calibration and certification settings);
- external load cell incorrectly positioned or axis obstructed;
- procedure left on hold (Certification not completed).
How to resolve:
- Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms (CEMAS technician).
- Check that nothing is obstructing the axis and that there are no other active alarms.
- Repeat the procedure (CEMAS technician) and check the result under Machine Diagnostics > Calibrations and Certifications.
Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.
Axis calibration and certification settings
How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.
Check:
- Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
- Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).
Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.
Certification not completed
How to identify it: under Machine Diagnostics > Calibrations and Certifications, on the Table tab > Certification, the result is Interrupted or Not performed.
Check:
- Check the date and result of the last certification.
- Check Machine status > Alarm monitor for the alarms that caused the interruption.
Remedy: once the causes have been rectified, the certification must be repeated by CEMAS Elettra personnel or under their supervision.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15001-2.XX - Table - Shaft - Safety brake opening timeout
What this means: when the safety brake on the table axis is released, with the safety devices in place, the brake-open signal does not arrive within 500 milliseconds (ms) – a fixed value. Check only active if the signal is enabled.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- brake faulty, not powered or with the connector disconnected (Brake function item);
- brake switch tripped (Breaker triggered alarm);
- brake open sensor faulty, out of calibration or disconnected.
How to resolve:
- If Brake breaker triggered is also active under Machine status > Alarm monitor, resolve that first.
- Check the brake power supply and connector: when released, the brake must open (maintenance technician).
- Check that the open brake sensor LED lights up; if not, adjust or replace the sensor (maintenance technician).
- If the brake does not open, do not force the axis.
Reset: alarm stored; clear by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: only on models with a safety brake on the table (911MK2, 911MK2-IR, 918MK2, 918MK2-IR). Machine option configured by CEMAS.
Brake performance
How to identify the fault: when the axle is released, the brake does not click, the axle does not move, or the ‘brake open’ signal is not received.
Check:
- Check that the brake is receiving power at the release control (maintenance technician).
- Check the brake connector and cable (maintenance technician).
- Check that the brake-open sensor switches (LED) when the brake opens (maintenance technician).
Remedy: the maintenance technician must repair the connection or replace the sensor or brake; if the brake is integrated into the motor, contact CEMAS Elettra S.r.l. support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15302-2.XX - Table - Axis calibration and certification - Timeout capability
What this means: the table axis force capability procedure did not complete within the maximum time limit (default 900 seconds (s), configured by CEMAS).
Effect: Alarm (red line). The procedure is interrupted (status Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.
Probable causes:
- force failing to stabilise at the required values (Axis calibration and certification settings);
- external load cell incorrectly positioned or axis obstructed;
- procedure left on hold (Capability not completed).
How to resolve:
- Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms (CEMAS technician).
- Check that nothing is obstructing the axis and that there are no other active alarms.
- Repeat the procedure (CEMAS technician) and check the result under Machine Diagnostics > Calibrations and Certifications.
Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.
Axis calibration and certification settings
How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.
Check:
- Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
- Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).
Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.
Capability not completed
How to identify it: under Machine Diagnostics > Calibrations and Certifications, Table tab > Capability, the result is Interrupted or Not performed.
Check:
- Check the date and result of the last capability test.
- Check Machine status > Alarm monitor for the alarms that caused the interruption.
Remedy: eliminate the causes; the capability test must be repeated by CEMAS Elettra personnel or under their supervision.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15102-2.XX – Table – Axis – Drive not configured
What this means: The field network diagnostics (PROFINET) signal that the table axis drive is either not configured or has a configuration that differs from that specified in the machine software.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is rejected.
Probable causes:
- drive replaced with a non-identical one or not yet configured (Configure drive option);
- drive configuration lost.
How to resolve:
- Check whether the drive has been replaced recently: the replacement must be identical to the original.
- Configure the drive (CEMAS technician).
Reset: the alarm clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.
Configure the drive
How to identify this: the axis drive is not configured, for example following a replacement.
Check:
- Check whether the drive has been replaced recently.
- Check that the model fitted is the one specified in the wiring diagram.
Remedy: the drive must be configured by CEMAS Elettra personnel: contact support (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15002-2.XX - Table - Board - Breaker triggered
What this means: The circuit breaker (thermal) supplying the safety brake on the table axis has tripped: the input of the circuit breaker’s auxiliary contact, enabled in the configuration, is low.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- circuit breaker tripped due to overload or short circuit on the brake or its cable (entry Circuit breaker (thermal) tripped);
- circuit breaker opened for maintenance and not reset;
- auxiliary contact or input wiring broken.
How to resolve:
- In the electric panel, reset the table brake circuit breaker (electrical maintenance technician).
- If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
- If the circuit breaker is closed but the alarm persists, check the auxiliary contact and the wiring.
Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using Reset.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.
Circuit breaker (thermal) has tripped
How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.
Check:
- Locate the component’s circuit breaker on the wiring diagram and check its position.
- Check that the thermal setting corresponds to the diagram.
- Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.
Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15103-2.XX – Table – Beam – Drive not accessible
What this means: The PLC is unable to communicate with the table axis drive via the fieldbus (PROFINET).
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- drive switched off or without logic power supply (see Drive power-on);
- network cable disconnected or damaged, or network switch not powered (see Check communication).
How to resolve:
- Check under Machine status > Alarm monitor whether a circuit breaker alarm is also active: if so, resolve that first.
- Check that the drive’s display or status LEDs are lit (electrical maintenance technician).
- Check the network cable: the port LEDs must be lit or flashing (electrical maintenance technician).
Reset: the fault message clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Powering on the drive
How to identify the problem: the drive is not responding to the PLC: the display or status LEDs are off.
Check:
- Check that the drive is powered (display or LEDs lit).
- Check the drive’s power switches in the electric panel.
Remedy: restore the power supply; if the drive remains off or in error mode, have it checked (by an electrical maintenance technician).
Check the message
How to identify the problem: the drive is switched on but the PLC is not communicating with it.
Check:
- Check the drive’s Profinet network cable and the port LED.
- Check in Machine Diagnostics > Motor Status that the axis values are updating.
Remedy: Reconnect or replace the network cable (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15303-2.XX - Table - Axis calibration and certification - External load cell error
What this means: during a procedure relating to the force on the table axis, the external load cell used as a reference is in alarm mode. Force-related procedures are carried out by CEMAS Elettra personnel or under their direct supervision.
Effect: Alarm (red line). The procedure is interrupted (status Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.
Probable causes:
- external load cell disconnected or with a damaged cable (Load cell connection section);
- faulty external load cell (Load cell functionality section).
How to resolve:
- Check the alarms in the External load cell unit under Machine status > Alarm monitor and resolve them.
- Check the power supply and network cable of the external load cell (CEMAS technician).
- Repeat the procedure.
Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.
Load cell functionality
How to identify this: the external load cell is connected, but the force reading is implausible or immediately goes to full scale.
Check:
- Visually inspect the load cell and its cable.
- Check that the load cell’s full-scale range is suitable for the force involved in the procedure.
- Check that the load cell is correctly positioned, with no lateral loads.
Remedy: replace the load cell if it is damaged or unsuitable; to have the load cell checked, contact CEMAS Elettra support.
Load cell connection
How to identify the problem: the external load cell is not communicating with the machine.
Check:
- Check the power supply to the load cell and its amplifier.
- Check the network cable between the load cell and the machine, and the communication LEDs.
Remedy: Reconnect or replace the cables and repeat the procedure.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15003-2.XX – Table – Circuit board – Logic switch
What this means: The circuit breaker (thermal logic) supplying power to the table axis drive control unit has tripped: the auxiliary contact input, enabled in the configuration, is low.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- circuit breaker tripped due to overload or short circuit on the drive power supply (item Circuit breaker (thermal) tripped);
- circuit breaker opened for maintenance and not reset;
- auxiliary contact or input wiring broken.
How to resolve:
- In the electric panel, reset the logic circuit breaker (electrical maintenance technician).
- If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
- If the circuit breaker is closed but the alarm persists, check the auxiliary contact and the wiring.
Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using Reset.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.
Circuit breaker (thermal) has tripped
How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.
Check:
- Locate the component’s circuit breaker on the wiring diagram and check its position.
- Check that the thermal setting corresponds to the diagram.
- Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.
Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15004-2.XX - Table - Board - Power switch
What this means: The circuit breaker (thermal overload) supplying power to the drive unit of the table axis has tripped.
Effect: The message is not displayed in the Alarm Monitor. The tripping of the circuit breaker can be identified by the Breaker triggered alarm in the axis details (M15101-2.XX): follow the instructions for that item.
Circuit breaker (thermal) has tripped
How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.
Check:
- Locate the component’s circuit breaker on the wiring diagram and check its position.
- Check that the thermal setting corresponds to the diagram.
- Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.
Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15304-2.XX - Table - Axis calibration and certification - Maximum force not achievable
What this means: when the table axis force command is set to 100 per cent, the external load cell measures a value lower than the Maximum force required by the procedure. Force-related procedures are carried out by CEMAS Elettra personnel or under their direct supervision.
Effect: Alarm (red line). The procedure is interrupted (status Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.
Probable causes:
- The procedure’s Maximum force exceeds that which the axis can deliver (under Axis calibration and certification settings);
- On hydraulic machines, the maximum pressure of the power unit is set too low (under Set maximum pressure valve);
- External load cell not calibrated.
How to resolve:
- Check the Maximum force under Machine settings > General settings > Tool interfaces, Table tab > Axes > Calibration (CEMAS technician).
- On hydraulic machines, check the setting of the maximum pressure valve (maintenance technician).
- Repeat the procedure.
Reset: alarm logged; clear by selecting Reset in the Alarm Monitor after rectifying the cause.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.
Record maximum pressure valve
How to recognise this: the table’s maximum force is not reached and the pressure remains below the expected value.
Check:
- Under Machine diagnostics > Motor status, read the maximum pressure reached at 100 per cent force.
- Compare this with the valve’s set point: approximately 170 bar on ST welding machines, approximately 210 bar on HL welding machines (maintenance technician).
Remedy: the maintenance technician adjusts the set screw on the maximum pressure valve to the specified value, whilst the machine is in a safe state.
Axis calibration and certification settings
How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.
Check:
- Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
- Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).
Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15104-2.XX - Table - Drive - Hardware error
What this means: the field network diagnostics signal a hardware fault in the table axis drive or one of its modules.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- drive electronics fault;
- unstable logic power supply.
How to resolve:
- Read the fault code (Drive fault code) in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis error code entry).
- Switch the machine off and on again in accordance with the user manual (maintenance technician).
- If the fault recurs, report the code to the service department: the drive may need replacing.
Reset: the fault message clears automatically once the cause has been rectified; then press the Reset button on the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.
Axis error code
How to identify it: the axis drive has encountered an error.
Check:
- In Machine Diagnostics > Motor Status, open the axis card and tap the i icon.
- Read and note down the error code (Drive fault code, Alarms word tab) displayed in the diagnostics pop-up.
Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the error recurs, report the code to CEMAS Elettra S.r.l. support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15305-2.XX - Table - Axis calibration and certification - Not calibrated
What this means: The table axis force calibration is invalid: it has never been carried out, was interrupted, or was cancelled by a machine initialisation.
Effect: Warning (yellow line). The axis is not ready: the automatic cycle cannot start.
Probable causes:
- new machine or one that has just been initialised;
- last calibration was interrupted (entry Calibration not completed).
How to resolve:
- Check the result of the last calibration in Machine Diagnostics > Calibrations and Certifications, Table tab > Calibration.
- Perform the calibration via Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration (CEMAS technician).
Reset: the warning clears automatically once calibration is complete.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.
Calibration not completed
How to identify this: under Machine Diagnostics > Calibrations and Certifications, Table tab > Calibration, the result is Interrupted or Not performed.
Check:
- Check the date and result of the last calibration.
- Check Machine Status > Alarm Monitor for the alarms that caused the calibration to be interrupted.
Remedy: once the causes have been rectified, the calibration must be repeated by CEMAS Elettra personnel or under their supervision.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15105-2.XX - Table - Shaft - Drive alarm
What this means: The table axis drive has encountered an error: it has detected a problem with the motor, the encoder, the power supply or the movement. This error is not signalled when safety guards are open or the safety light curtain is in alarm mode.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- overload or obstructed movement;
- motor or drive overheating;
- damaged encoder or motor cables.
How to resolve:
- Read the fault code (Drive fault code) in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis error code entry).
- Check that nothing is obstructing movement and that the motor is not overheating.
- Press the Reset button on the Alarm Monitor; if the fault reoccurs, report the code to support.
Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.
Axis error code
How to identify it: the axis drive has encountered an error.
Check:
- In Machine Diagnostics > Motor Status, open the axis card and tap the i icon.
- Read and note down the error code (Drive fault code, Alarms word tab) displayed in the diagnostics pop-up.
Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the error recurs, report the code to CEMAS Elettra S.r.l. support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15005-2.XX - Table - Beam - Incorrect contact position
What this means: during welding force adjustment, the table position moves outside the permitted range: more than 10 millimetres (mm) above or 30 mm below the starting height, derived from Workpiece contact (fixed values). Not checked during certification and capability assessment.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- Incorrect Workpiece contact dimension in Tool settings > Positions (Workpiece contact dimension setting);
- Missing, duplicate, incorrectly positioned workpieces or foreign objects in the cavities (Correct workpiece positioning);
- parts different from those intended for the fitted tools.
How to resolve:
- Check the parts in the cavities: ensure they are present, correct, fully inserted and free from foreign objects.
- Compare the position at contact (under Machine Diagnostics > Motor Status) with Part Contact.
- If the dimension is incorrect, have it corrected by the person responsible for the tools and run a test cycle.
Reset: alarm logged; clear it using Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.
Setting the contact height for workpieces
How to recognise it: the alarm appears during every cycle with correct workpieces, always at the same stage.
Check:
- In Machine Diagnostics > Motor Status, read the table position when the workpieces make contact.
- Compare this with the Workpiece contact dimension in Tool settings > Positions, Table tab: the difference must be between 30 mm below and 10 mm above.
Remedy: the tool manager corrects the dimension and runs a test cycle.
Correct positioning of parts
How to recognise it: the alarm only appears on certain cycles; the parts appear raised, warped or missing.
Check:
- Check that the parts are those specified for the tool.
- Check that they are fully inserted into the cavities and that there are no foreign objects or debris.
Remedy: the operator repositions the parts or cleans the cavities and repeats the cycle.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15006-2.XX - Table - Beam - Upper limit reached
What this means: with the current tool in place and outside the tool change cycle, the table axis has reached the Upper limit set for the tool in Tool Settings > Positions (hysteresis 1 mm).
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- Upper limit set too low compared to the other cycle dimensions (Upper limit setting option);
- workpieces lower than expected or missing, causing the axis to rise beyond the contact height;
- tools different from those specified in the loaded parameters.
How to resolve:
- Check that the workpieces are present and correct.
- Check in Equipment Settings > Positions that the Upper limit is higher than Workpiece contact and the other working dimensions; this limit can only be modified by CEMAS personnel.
- Check that the loaded parameters correspond to the fitted tools.
Reset: alarm stored; clear it by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.
Setting the upper limit
How to recognise it: the upper limit alarm appears with correct parts, always at the same stage of the cycle.
Check:
- Check in Tool Settings > Positions, under the Table tab, that the Upper Limit is higher than Workpiece Contact and the other working dimensions.
Remedy: CEMAS personnel correct the Upper limit (which can only be modified by CEMAS) and the tool manager checks the other dimensions.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15106-2.XX – Table – Beam – Technological object alarm
What this means: The PLC’s motion control for the table axis has signalled an error, such as a tracking error (the axis is not following the commanded position), a software limit being exceeded, or a referencing error. This error is not signalled when the safety guards are open or the safety light curtain is in alarm mode.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- movement braked or obstructed;
- drive in error or not ready;
- commanded position outside the axis limits.
How to resolve:
- Read the active bits of the Alarms word card in the drive diagnostics pop-up, which opens via the i icon on the motor card under Machine diagnostics > Motor status (Axis status code entry).
- Resolve any other drive alarms.
- Press the Reset button on the Alarm Monitor and attempt a manual movement via Machine Diagnostics > Manual Movements, the Machine tab, or using the arrows in the right-hand column.
Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.
Axis status coding
How to recognise it: the axis is stationary in alarm mode and its drive signals an abnormal status.
Check:
- In Machine Diagnostics > Motor Status, open the axis card and tap the i icon: the diagnostics pop-up displays the drive’s current statuses, errors and warnings.
- Make a note of the statuses and errors displayed.
Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the fault persists, report the noted data to CEMAS Elettra support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15306-2.XX - Table - Axis calibration and certification - Calibration in progress
What this means: The table axis force calibration procedure is in progress.
Effect: Info (grey line). Information: no action required.
How to resolve:
- Wait for the procedure to finish and check the result under Machine Diagnostics > Calibrations and Certifications.
Resolution: the message disappears automatically once the procedure is complete.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15007-2.XX – Table – Beam – Machine load cell error
What this means: the value from the internal load cell, which measures the force on the table’s axis, is outside the valid range (0–100 %).
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- load cell cable or connector disconnected or damaged (see Check electrical connection);
- load cell damaged, for example due to an overload (see Load cell functionality).
How to resolve:
- Read the load cell value under Machine diagnostics > Motor status: when the table is stationary and unloaded, it must be close to zero and never negative.
- Check the load cell cable and M12 connector (maintenance technician).
- If the value remains abnormal whilst the wiring is intact, the load cell must be replaced (CEMAS technician).
Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.
Load cell functionality
How to identify this: the load cell value under Machine Diagnostics > Motor Status is negative, constant or exceeds the maximum force of the welding machine.
Check:
- With the table stationary and no force applied, read the value in Machine Diagnostics > Motor Status: it should be close to zero.
- Apply force in manual mode: the value should increase steadily.
Remedy: if the value is abnormal whilst the wiring is intact, the load cell must be replaced: contact CEMAS Elettra support.
Check the electrical connection
How to identify the problem: the load cell value in Machine Diagnostics > Motor Status is missing or fluctuates erratically.
Check:
- Check that the load cell cable is intact and not pinched (maintenance technician).
- Check that the M12 connector is properly inserted and tightened (maintenance technician).
Remedy: the maintenance technician must re-establish the connection or replace the cable.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15307-2.XX - Table - Axis calibration and certification - Certification in progress
What this means: The certification procedure for the table’s axial force is in progress.
Effect: Info (grey line). Information: no action required.
How to resolve:
- Wait for the procedure to finish and check the result under Machine Diagnostics > Calibrations and Certifications.
Resolution: the message disappears automatically once the procedure has finished.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15107-2.XX - Table - Beam - Positive overtravel alarm
What this means: the positive over-travel limit switch on the table axis is active (if enabled): the axis has moved beyond its working travel.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic and tool change functions blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- axis moved beyond its travel limit in manual mode or with motion constraints disabled;
- home position lost or incorrect;
- limit switch faulty, out of calibration or disconnected (see Faulty sensors).
How to resolve:
- Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab, or using the arrows in the right-hand column (see Release Overtravel).
- With the axis in motion, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
- If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).
Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.
Release the overrun
How to recognise this: the axis has reached the over-travel limit, beyond its normal travel; continuing would damage the machine.
Check:
- In Machine Diagnostics > Manual Movements, on the Machine tab, check the direction in which the axis has reached the overtravel limit.
- Check that the overtravel sensor is not faulty or misaligned.
Remedy: move the axis by hand in the opposite direction until the sensor is released, then press Reset; if the axis does not move, contact CEMAS Elettra S.r.l. support.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15108-2.XX - Table - Beam - Negative overtravel alarm
What this means: the negative over-travel limit switch for the table axis is active (if enabled): the axis has moved beyond its working travel.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic and tool change functions blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- axis moved beyond its travel range in manual mode or with motion constraints disabled;
- homing lost or incorrect;
- limit switch faulty, out of calibration or disconnected (see Sensors not working).
How to resolve:
- Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab, or using the arrows in the right-hand column (see Release Overtravel).
- With the axis in motion, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
- If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).
Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.
Release the overrun
How to recognise this: the axis has reached the over-travel limit, beyond its normal travel; continuing would damage the machine.
Check:
- In Machine Diagnostics > Manual Movements, on the Machine tab, check the direction in which the axis has reached the overtravel limit.
- Check that the overtravel sensor is not faulty or misaligned.
Remedy: move the axis by hand in the opposite direction until the sensor is released, then press Reset; if the axis does not move, contact CEMAS Elettra S.r.l. support.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15008-2.XX – Table – Axis – Transducer position error
What this means: on electric axes with linear transducers, the table position read by the encoder differs by more than 10 mm from that of the transducer for more than 15 ms (fixed values).
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- axis home position lost or set to an incorrect value (Perform zeroing option);
- linear transducer faulty, disconnected or with the magnet displaced;
- mechanical slippage between the motor and the axis.
How to resolve:
- In Machine Diagnostics > Motor Status, compare the position of the axis with that of the transducers.
- If there are any transducer alarms, resolve them first.
- Perform homing using the Home position button for the axis in Machine settings > General settings > Tool interfaces, Table tab: with the machine in manual mode, set the reference position without moving the axis (CEMAS technician).
Reset: clear the alarm using the Reset button on the Alarm Monitor or by performing axis homing; then select Home position (right-hand column) and Automatic cycle to restart.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.
Perform a reset
How to identify this: the axis is not referenced (the Referenced indicator is grey in Machine Diagnostics > Motor Status) or its position does not match the actual position.
Check:
- Check the Home indicator for the axis in Machine Diagnostics > Motor Status.
- Check whether the drive, motor or encoder has been replaced recently.
Remedy: Referencing is carried out manually using the axis’s Home position button in Machine settings > General settings > Tool interfaces (in Machine settings > General settings > Components for gates and sliding tables): this sets the reference position without moving the axis and remains valid even after the machine is switched off. This operation is reserved for CEMAS technicians.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15308-2.XX – Table – Axis calibration and certification – Capability assessment in progress
What this means: The table axis force capability procedure is in progress.
Effect: Info (grey line). Information: no action required.
How to resolve:
- Wait for the procedure to finish and check the result under Machine Diagnostics > Calibrations and Certifications.
Resolution: the message disappears automatically once the procedure has finished.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15009-2.XX - Table - Axis - Handling timeout
What this means: during positioning, the table axis remains outside the tolerance of the commanded position for more than 3 seconds (s) on the electric axes and 6 s on the hydraulic axes; these are fixed values.
Effect: Alarm (red line). The table stops (drive disabled). Machine alarm: automatic cycle interrupted (machine in manual mode), automatic mode and tool change blocked; during welding, the workpiece is a scrap piece.
Probable causes:
- mechanical obstruction to movement (see Movement of the mobile platen);
- insufficient available force, brake not released or drive restricted;
- on hydraulic machines: shut-off valves, speed control valve, proportional valve or pump not functioning (related items).
How to resolve:
- Check that nothing is obstructing movement.
- Check for other active alarms in Machine status > Alarm monitor (brake, drive, hydraulic power unit).
- Test the movement manually via Machine Diagnostics > Manual Movements, the Machine tab or using the arrows in the right-hand column: the axis must move smoothly.
- On hydraulic machines, check the pump and valves on the power unit (maintenance technician).
Reset: alarm logged; clear by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.
Movement of the mobile platen
How to recognise this: the table does not move or stops before reaching the commanded position.
Check:
- Check that there are no objects in the work area blocking the table.
- Test the movement manually via Machine Diagnostics > Manual Movements, the Machine tab or using the arrows in the right-hand column.
Remedy: remove the obstruction before moving the table again; if the table remains jammed for no apparent reason, contact CEMAS Elettra support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15309-2.XX - Table - Axis calibration and certification - Axis locked
What this means: during a force measurement procedure, the force on the table axis was increased to 100 per cent without the axis moving by at least 0.5 mm (fixed value).
Effect: Alarm (red line). The procedure is interrupted (result Interrupted in Machine Diagnostics > Calibrations and Certifications) and, whilst the alarm is active, the automatic cycle is blocked.
Probable causes:
- axis at end stop or external load cell incorrectly positioned;
- brake not released or limited actuation.
How to resolve:
- Check that the external load cell is fitted and centred between the table and the head, and that there are no alarms on it (CEMAS technician).
- Check the other active alarms in Machine Status > Alarm Monitor.
- Repeat the procedure.
Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15010-2.XX – Table – Beam – Upper limit force scaling
What this means: this warning (force exceeding the upper limit) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.
Effect: Alarm (red line). No effect on the machine.
How to resolve:
- If the warning appears, note down the full code, the time and the machine’s operating conditions.
- Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.
Axis calibration and certification settings
How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.
Check:
- Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
- Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).
Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.
Perform calibration
How to recognise this: the table force does not match the set value, or the calibration is invalid.
Check:
- Check under Machine Diagnostics > Calibrations and Certifications, Table tab > Calibration, for the result and date of the last calibration.
- Check whether the calibration has been modified manually (Manually edited calibration field).
Remedy: the CEMAS technician carries out the calibration via Machine Settings > General Settings > Tool Interfaces, under the Table tab > Axes > Calibration using the external load cell and checks the result.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15011-2.XX - Table - Beam - Lower limit force scaling
What this means: this warning (force falling below the lower limit) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.
Effect: Alarm (red line). No effect on the machine.
How to resolve:
- If the warning appears, note down the full code, the time and the machine’s operating conditions.
- Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.
Axis calibration and certification settings
How to identify this: the table force procedures do not complete or do not reach the required values, even when the external load cell is fitted correctly.
Check:
- Check the results and values of the last procedure under Machine Diagnostics > Calibrations and Certifications, Table tab.
- Compare the minimum force, maximum force and procedure points in Machine Settings > General Settings > Tool Interfaces, Table tab > Axes > Calibration with the force available on the machine (CEMAS technician).
Remedy: the CEMAS technician corrects the configuration values and repeats the procedure.
Perform calibration
How to recognise this: the table force does not match the set value, or the calibration is invalid.
Check:
- Check under Machine Diagnostics > Calibrations and Certifications, Table tab > Calibration, for the result and date of the last calibration.
- Check whether the calibration has been modified manually (Manually edited calibration field).
Remedy: the CEMAS technician carries out the calibration via Machine Settings > General Settings > Tool Interfaces, under the Table tab > Axes > Calibration using the external load cell and checks the result.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M15014-2.XX – Table – Beam – Unreferenced beam
What this means: the table axis is powered but does not have a reference height: the positions read are unreliable and the axis cannot perform height-controlled movements.
Effect: Alarm (red line). The table drive remains disabled and the axis is not ready: the automatic cycle and tool change cannot start.
Probable causes:
- motor, encoder or drive replaced (see Perform zeroing);
- reference lost following a fault in the encoder or its power supply.
How to resolve:
- Check the table’s Referenced indicator in Machine Diagnostics > Motor Status: grey indicates the axis is not referenced.
- Perform referencing using the Home position button for the axis in Machine settings > General settings > Tool interfaces, Table tab: with the machine in manual mode, set the reference position without moving the axis; if linear transducers are present, the position is taken from these (CEMAS technician).
Reset: this is automatically cleared after homing.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.
Perform a reset
How to identify this: the axis is not referenced (the Referenced indicator is grey in Machine Diagnostics > Motor Status) or its position does not match the actual position.
Check:
- Check the Home indicator for the axis in Machine Diagnostics > Motor Status.
- Check whether the drive, motor or encoder has been replaced recently.
Remedy: Referencing is carried out manually using the axis’s Home position button in Machine settings > General settings > Tool interfaces (in Machine settings > General settings > Components for gates and sliding tables): this sets the reference position without moving the axis and remains valid even after the machine is switched off. This operation is reserved for CEMAS technicians.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
External load cell
Alarms from the external load cell, the reference instrument connected to the machine for calibration, certification and force capability; the results can be found under Machine Diagnostics > Calibrations and Certifications.
M16000-0.XX – External load cell – Full scale reached
What this means: the force measured by the external load cell has remained outside the load cell’s measurement range for 3 s. This check is active when the external load cell is enabled for calibration, certification or force capability testing.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked. The current procedure is interrupted.
Probable causes:
- load cell with a full-scale range lower than the applied force (Inappropriate load cell);
- load cell faulty or not calibrated (Load cell functionality).
How to resolve:
- Check that the load cell’s full-scale range is adequate for the machine’s maximum force.
- Check that the load cell is correctly positioned and free from lateral loads.
- Replace the load cell with a suitable one and repeat the procedure.
Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Load cell functionality
How to identify this: the external load cell is connected, but the force reading is implausible or immediately goes to full scale.
Check:
- Visually inspect the load cell and its cable.
- Check that the load cell’s full-scale range is suitable for the force involved in the procedure.
- Check that the load cell is correctly positioned, with no lateral loads.
Remedy: replace the load cell if it is damaged or unsuitable; to have the load cell checked, contact CEMAS Elettra support.
Unsuitable load cell
How to recognise it: the full-scale alarm always occurs at the highest forces specified in the procedure.
Check:
- Read the full-scale value on the load cell nameplate.
- Compare it with the machine’s maximum force.
Remedy: use a load cell with a full-scale value greater than the machine’s maximum force and repeat the procedure.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M16001-0.XX – External load cell – Communication
What this means: The external load cell is not responding to the welding machine’s PLC via the network. This check is active when the external load cell is enabled for calibration, certification or force capability testing.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The current procedure is interrupted.
Probable causes:
- Load cell not powered or network cable disconnected (Load cell connection).
How to resolve:
- Check the power supply to the load cell and its amplifier.
- Check the network cable between the load cell and the machine.
- Repeat the procedure.
Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Load cell connection
How to identify the problem: the external load cell is not communicating with the machine.
Check:
- Check the power supply to the load cell and its amplifier.
- Check the network cable between the load cell and the machine, and the communication LEDs.
Remedy: Reconnect or replace the cables and repeat the procedure.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M16002-0.XX – External load cell – Profinet disconnection
What this means: Profinet communication with the external load cell has been interrupted. This check is active when the external load cell is enabled for calibration, certification or force capability testing.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The current procedure is interrupted.
Probable causes:
- Profinet cable disconnected or damaged, load cell not powered (Load cell connection).
How to resolve:
- Check the load cell’s power supply and LEDs.
- Check the Profinet cable and connectors.
- Repeat the procedure.
Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Load cell connection
How to identify the problem: the external load cell is not communicating with the machine.
Check:
- Check the power supply to the load cell and its amplifier.
- Check the network cable between the load cell and the machine, and the communication LEDs.
Remedy: Reconnect or replace the cables and repeat the procedure.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Control inputs
Alarms from the machine input commands, configurable input signals, including those received from the Smart accessory. These are configured under Machine Settings > General Settings > Components, on the Input Commands tab.
M17000-0.XX - Control inputs - Incorrect signal address
What this means: the machine’s input command, configured as a Smart Accessory signal, has a signal number outside the range 1–20. This check applies only to Smart Accessory commands, provided the Smart Accessory is connected; digital commands do not trigger the alarm. In the code, XX is the input command number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- Invalid Smart Accessory signal (Reset the commands).
How to resolve:
- Check command
XXin Machine settings > General settings > Components, Input commands tab. - Correct the signal number (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Reset the controls
How to recognise it: the alarm appears on a machine command associated with a signal from the Smart accessory.
Check:
- Check the command in Machine Settings > General Settings > Components, under the Input Commands tab, or in Machine Settings > General Settings > Components, under the Output Commands tab.
- Check that the signal number is between 1 and 20.
Remedy: correct the signal number (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Command outputs
Alarms from the machine output commands, configurable output signals, which can also be sent to the Smart accessory. These are configured under Machine Settings > General Settings > Components, on the Output Commands tab.
M18000-0.XX – Control outputs – Incorrect signal address
What this means: the machine’s output command, configured as a Smart Accessory signal, has a signal number outside the range 1–20. This check applies only to Smart Accessory commands, provided the Smart Accessory is connected; digital commands do not trigger the alarm. In the code, XX is the output command number (from 01 to 20).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- Invalid Smart accessory signal (Reset the commands).
How to resolve:
- Check command
XXin Machine settings > General settings > Components, Output commands tab. - Correct the signal number (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Reset the controls
How to recognise it: the alarm appears on a machine command associated with a signal from the Smart accessory.
Check:
- Check the command in Machine Settings > General Settings > Components, under the Input Commands tab, or in Machine Settings > General Settings > Components, under the Output Commands tab.
- Check that the signal number is between 1 and 20.
Remedy: correct the signal number (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Pump
Alarms for the machine’s pumps (up to four), triggered by vacuums, clamps and valves: electrical protection, pressure, level, filter and oil temperature. XX is the pump number. These are configured under Machine Settings > General Settings > Components, on the Pumps tab.
M19000-0.XX - Pump - Breaker triggered
What this means: the pump’s (thermal) protection switch is open. In the code, XX is the pump number (from 01 to 04).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked. The pump stops: vacuum lines, clamps and valves that use it have no pressure.
Probable causes:
- motor overload or fault (Circuit breaker (thermal) tripped);
- circuit breaker setting too low.
How to resolve:
- Reset the pump circuit breaker and check that it does not trip again (maintenance technician).
- If it trips again, check the motor and pump circuit (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.
Circuit breaker (thermal) has tripped
How to identify the problem: in the electric panel, the component’s circuit breaker (thermal) is tripped and the component is not receiving power.
Check:
- Locate the component’s circuit breaker on the wiring diagram and check its position.
- Check that the thermal setting corresponds to the diagram.
- Reset the circuit breaker and check that it does not trip again, either on start-up or during operation.
Remedy: if it trips again, investigate the cause (seized motor, short circuit, overload) and repair or replace the component (electrical maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M19001-0.XX – Pump – Maximum pressure
What this means: pump pressure exceeds the alarm threshold. In current versions of the machine software, the alert is programmed but is not triggered. In the code, XX is the pump number (from 01 to 04).
Effect: Alarm (red line): none.
If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out. Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.
M19002-0.XX - Pump - Analogue pressure alarm
What this means: the signal from the pump’s analogue pressure sensor is outside the valid range: the value is unreliable. In the code, XX is the pump number (from 01 to 04).
Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle. It is stored in memory. The pump continues to operate.
Probable causes:
- sensor disconnected, cable broken or sensor faulty.
How to resolve:
- Check the pressure sensor connector and cable (maintenance technician).
- If the wiring is intact, replace the sensor (maintenance technician).
Reset: once the cause has been rectified, press Reset on the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.
M19003-0.XX - Pump - Pressure-reach timeout
What this means: the hydraulic control unit has not reached the target pressure (with a tolerance of ±10 bar) within the specified time (5 s as standard). The target pressure and time are part of the pump configuration (Machine settings > General settings > Components, Pumps tab), set by CEMAS. This applies only to hydraulic pumps. In the code, XX is the pump number (from 01 to 04).
Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle. It remains stored. The pump continues to operate.
Probable causes:
- low oil level or leaks in the circuit;
- worn pump or misadjusted control valve;
- faulty pressure sensor.
How to resolve:
- Check the oil level and ensure there are no leaks (maintenance technician).
- Check the pressure on the control unit’s pressure gauge (maintenance technician).
- If the pressure is correct, check the pressure sensor (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.
M19004-0.XX - Pump - Low oil level
What this means: the pump reservoir level sensor is indicating insufficient oil. In the code, XX is the pump number (from 01 to 04).
Effect: Alarm (red line): warning only: does not stop the machine or interrupt the automatic cycle. It remains stored in memory. The pump continues to operate. Continuing to operate with low oil levels may damage the pump.
Probable causes:
- oil consumption or leaks;
- faulty level sensor.
How to resolve:
- Check the level on the tank gauge.
- Top up with the oil specified in the user manual (maintenance technician).
- Check for any leaks in the circuit (maintenance technician).
Reset: once the cause has been rectified, press Reset on the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.
M19005-0.XX - Pump - Clogged oil filter
What this means: the oil filter sensor on the pump is signaling that the filter is blocked. In the code, XX is the pump number (from 01 to 04).
Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle. The fault is stored in memory. The pump continues to operate.
Probable causes:
- dirty filter or filter at the end of its service life;
- faulty filter sensor.
How to resolve:
- Check the filter blockage indicator.
- Replace the cartridge in accordance with the user manual (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.
M19006-0.XX - Pump - Maximum temperature
What this means: the oil thermostat on the pump indicates that the maximum temperature has been reached. In the code, XX is the pump number (from 01 to 04).
Effect: Alarm (red line): warning only: does not stop the machine or interrupt the automatic cycle. It remains stored in memory. The pump continues to operate. Oil that is too hot reduces the performance and service life of the circuit.
Probable causes:
- oil cooler or fan is dirty or not working;
- high ambient temperature or very heavy workload;
- low oil level.
How to resolve:
- Check the oil level and the operation of the control unit’s cooling system (maintenance technician).
- Clean the heat exchanger (by a maintenance technician).
- Wait for the oil to cool down before resuming operation.
Recovery: once the cause has been rectified, press Reset on the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the pump is fitted (Machine settings > General settings > Components, Pumps tab), option configured by CEMAS.
Gate
Alarms for the front and rear gates, which close off the work area during the cycle: movement times, sensors, controls and, for motorised gates, the axis and drive. Gate alarms stop the gate but do not switch the machine to manual mode.
The gates are configured in Machine Settings > General Settings > Components, under the Gates tab, and are operated manually via Machine Diagnostics > Manual Movements, under the Machine > Gates tab; the status of the motors can be viewed in Machine Diagnostics > Motor Status, under the Gates tab.
Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).
M20000-0.XX - Gate - Closing timeout
What this means: the gate has not reached the closed position within the closing time-out (default 10 s, under Machine settings > General settings > Components, Gates tab); for speed-controlled gates, the travel time is added to this. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). It does not switch the machine to manual mode: the automatic cycle remains on hold until the gate reaches the required position.
Probable causes:
- no power or motor in alarm (item Check drive);
- movement obstructed or dirty guides (sections Check cleanliness and Movement not completed);
- closed position sensor out of calibration or faulty (section Sensors not working);
- time-out too short (section Insufficient time).
How to resolve:
- Operate the gate manually via Machine diagnostics > Manual movements, Machine tab > Gates, and observe the movement.
- If it does not move, check the air supply (pneumatic) or the axis alarms (motorised).
- If it does not reach the end of its travel, remove any obstructions and clean the guides; if it does reach the end, check the sensor LED (maintenance technician).
- If the movement is smooth but slow, increase the time-out (CEMAS technician).
Reset: clear the fault by selecting Reset in the Alarm Monitor or by pressing the cycle start button, once the cause has been rectified.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.
Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).
Check the drive
How to identify the problem: the gate does not move or moves jerkily when activated.
Check:
- Pneumatic gate: check that air is reaching the cylinder and that the hoses are connected, intact and not kinked.
- Motorised gate: check under Machine status > Alarm monitor and under Machine diagnostics > Motor status, Gates tab, that the motor and drive have no alarms.
Remedy: the maintenance technician must restore the pneumatic supply or resolve any drive alarms.
Not enough time
How to recognise this: the gate completes its movement smoothly, but shortly after the time-out has expired.
Check:
- Time the movement by initiating it from Machine Diagnostics > Manual Movements, Machine tab > Gates.
- Compare this with the opening or closing Time-out in Machine Settings > General Settings > Components, Gates tab.
Remedy: the CEMAS technician increases the time-out by an appropriate margin.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Check that it is clean
How to recognise it: the gate slides with difficulty, slows down at certain points or is noisy.
Check:
- Check that the guides, runners and bearings are clean and lubricated (by a maintenance technician).
- Move the gate by hand and check that it runs smoothly.
Remedy: the maintenance technician should clean and lubricate the guides: CEMAS Elettra recommends NLGI 2 grease or Arexons GC300, always using the same type, as specified in the component catalogues.
Move not completed
How to identify the problem: the gate stops before reaching the end of its travel or reaches the end but the sensor does not light up.
Check:
- Check that nothing is obstructing the gate’s movement.
- Check the limit switch LED and ensure its input is correct in Machine Settings > General Settings > Components, under the Gates tab (maintenance technician).
Remedy: the maintenance technician removes the obstruction or adjusts the sensor; the CEMAS technician corrects any incorrect inputs.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20100-0.XX – Gate – External alarm
What this means: the warning (external gate alarm) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). No effect on the machine.
How to resolve:
- If the alert appears, note down the full code, the time and the machine’s operating conditions.
- Contact CEMAS Elettra support: this may indicate a machine software version different from the one documented.
Availability: Machine option: only with Siemens or HDT motorised gates (Type).
M20101-0.XX – Gate – Security alarm
What this means: this warning (gate drive protection alarm) is provided for in the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). No effect on the machine.
How to resolve:
- If the alarm appears, note down the full code, the time and the machine’s operating conditions.
- Contact CEMAS Elettra support: this may indicate a machine software version different from the one documented.
Availability: Machine option: only with Siemens or HDT motorised gates (Type).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20001-0.XX - Gate - Opening timeout
What this means: the gate has not reached the open position within the opening time-out (default 10 s, under Machine settings > General settings > Components, Gates tab); for speed-controlled gates, the travel time is added to this. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (command withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold until the gate reaches the required position.
Probable causes:
- no power or motor in alarm (item Check drive);
- movement obstructed or dirty guides (sections Check cleanliness and Movement not completed);
- open position sensor out of calibration or faulty (section Sensors not working);
- time-out too short (section Insufficient time).
How to resolve:
- Operate the gate manually via Machine diagnostics > Manual movements, Machine tab > Gates, and observe the movement.
- If it does not move, check the air supply (pneumatic) or the axis alarms (motorised).
- If it does not reach the end of its travel, remove any obstructions and clean the guides; if it does reach the end, check the sensor LED (maintenance technician).
- If the movement is smooth but slow, increase the time-out (CEMAS technician).
Reset: clear the fault by selecting Reset in the Alarm Monitor or by pressing the cycle start button, once the cause has been rectified.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.
Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).
Check the drive
How to identify the problem: the gate does not move or moves jerkily when activated.
Check:
- Pneumatic gate: check that air is reaching the cylinder and that the hoses are connected, intact and not kinked.
- Motorised gate: check under Machine status > Alarm monitor and under Machine diagnostics > Motor status, Gates tab, that the motor and drive have no alarms.
Remedy: the maintenance technician must restore the pneumatic supply or resolve any drive alarms.
Not enough time
How to recognise this: the gate completes its movement smoothly, but shortly after the time-out has expired.
Check:
- Time the movement by initiating it from Machine Diagnostics > Manual Movements, Machine tab > Gates.
- Compare this with the opening or closing Time-out in Machine Settings > General Settings > Components, Gates tab.
Remedy: the CEMAS technician increases the time-out by an appropriate margin.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Check that it is clean
How to recognise it: the gate slides with difficulty, slows down at certain points or is noisy.
Check:
- Check that the guides, runners and bearings are clean and lubricated (by a maintenance technician).
- Move the gate by hand and check that it runs smoothly.
Remedy: the maintenance technician should clean and lubricate the guides: CEMAS Elettra recommends NLGI 2 grease or Arexons GC300, always using the same type, as specified in the component catalogues.
Move not completed
How to identify the problem: the gate stops before reaching the end of its travel or reaches the end but the sensor does not light up.
Check:
- Check that nothing is obstructing the gate’s movement.
- Check the limit switch LED and ensure its input is correct in Machine Settings > General Settings > Components, under the Gates tab (maintenance technician).
Remedy: the maintenance technician removes the obstruction or adjusts the sensor; the CEMAS technician corrects any incorrect inputs.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20102-0.XX - Gate - Drive not configured
What this means: The field network diagnostics (PROFINET) signal that the gate drive is not configured or has a configuration different from that expected. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (command withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.
Probable causes:
- the drive has been replaced with one that is not identical or has not yet been configured (see Configure drive);
- drive configuration lost.
How to resolve:
- Check whether the drive has been replaced recently: the replacement must be identical to the original.
- Configure the drive (CEMAS technician).
Reset: this clears automatically once the drive is recognised.
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.
Availability: Machine option: only with Siemens or HDT motorised gates (Type).
Configure the drive
How to identify this: the axis drive is not configured, for example following a replacement.
Check:
- Check whether the drive has been replaced recently.
- Check that the model fitted is the one specified in the wiring diagram.
Remedy: the drive must be configured by CEMAS Elettra personnel: contact support (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20002-0.XX - Gate - Closed position not released
What this means: when the opening command is issued, once the time-out has expired, the closed-position sensor is still active: either the gate has not started moving or the sensor remains active. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stationary (command withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.
Probable causes:
- gate mechanically jammed (see Gate jammed);
- command not executed: no air supply or motor in alarm mode (see Check operation);
- closed position sensor constantly active (see Sensors not working).
How to resolve:
- Operate the gate manually via Machine diagnostics > Manual movements, Machine tab > Gates, and observe the movement.
- If the gate does not move, check the air supply or axis alarms and remove any obstructions.
- If the gate moves, check that the closed position sensor LED goes out (maintenance technician).
Reset: clear the fault using Reset in the Alarm Monitor or the cycle start button, once the cause has been rectified.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and the checks carried out.
Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).
Check the drive
How to identify the problem: the gate does not move or moves jerkily when activated.
Check:
- Pneumatic gate: check that air is reaching the cylinder and that the hoses are connected, intact and not kinked.
- Motorised gate: check under Machine status > Alarm monitor and under Machine diagnostics > Motor status, Gates tab, that the motor and drive have no alarms.
Remedy: the maintenance technician must restore the pneumatic supply or resolve any drive alarms.
Gate locked
How to identify the problem: when the command is given, the gate does not move and the position sensor remains lit.
Check:
- Check that there are no mechanical obstructions blocking the gate.
- Operate the gate manually via Machine Diagnostics > Manual Movements, under the Machine tab > Gates.
Remedy: the maintenance technician removes the obstruction; if the gate remains stationary for no apparent reason, check the pneumatic system or the drive.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20003-0.XX - Gate - Open position not released
What this means: when the closing command is issued, once the time-out has expired, the open-position sensor is still active: either the gate has not started moving or the sensor remains active. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (command withdrawn, motor disabled). Does not switch the system to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.
Probable causes:
- gate mechanically jammed (see Gate jammed);
- command not executed: no air supply or motor in alarm mode (see Check operation);
- open position sensor always active (see Sensors not working).
How to resolve:
- Operate the gate manually via Machine diagnostics > Manual movements, Machine tab > Gates, and observe the movement.
- If the gate does not move, check the air supply or axis alarms and remove any obstructions.
- If the gate moves, check that the open position sensor LED goes out (maintenance technician).
Reset: clear the fault using Reset in the Alarm Monitor or the cycle start button once the cause has been rectified.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.
Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).
Check the drive
How to identify the problem: the gate does not move or moves jerkily when activated.
Check:
- Pneumatic gate: check that air is reaching the cylinder and that the hoses are connected, intact and not kinked.
- Motorised gate: check under Machine status > Alarm monitor and under Machine diagnostics > Motor status, Gates tab, that the motor and drive have no alarms.
Remedy: the maintenance technician must restore the pneumatic supply or resolve any drive alarms.
Gate locked
How to identify the problem: when the command is given, the gate does not move and the position sensor remains lit.
Check:
- Check that there are no mechanical obstructions blocking the gate.
- Operate the gate manually via Machine Diagnostics > Manual Movements, under the Machine tab > Gates.
Remedy: the maintenance technician removes the obstruction; if the gate remains stationary for no apparent reason, check the pneumatic system or the drive.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20103-0.XX – Gate – Drive unit inaccessible
What this means: The PLC is unable to communicate with the gate drive on the field network (PROFINET). In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (command withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains waiting for the gate to reach the required position.
Probable causes:
- drive switched off or without logic power supply (see Drive power-up);
- network cable disconnected or damaged (see Check communication).
How to resolve:
- If a limit switch alarm is also active, resolve that first.
- Check that the drive’s display or status LEDs are lit (electrical maintenance technician).
- Check the network cable: the port LEDs must be lit or flashing (electrical maintenance technician).
Reset: clears automatically when communication is restored.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: only with Siemens or HDT motorised gates (Type).
Powering on the drive
How to identify the problem: the drive is not responding to the PLC: the display or status LEDs are off.
Check:
- Check that the drive is powered (display or LEDs lit).
- Check the drive’s power switches in the electric panel.
Remedy: restore the power supply; if the drive remains off or in error mode, have it checked (by an electrical maintenance technician).
Check the message
How to identify the problem: the drive is switched on but the PLC is not communicating with it.
Check:
- Check the drive’s Profinet network cable and the port LED.
- Check in Machine Diagnostics > Motor Status that the axis values are updating.
Remedy: Reconnect or replace the network cable (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20004-0.XX - Gate - External alarm
What this means: the warning (external gate alarm) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). No effect on the machine.
How to resolve:
- If the alert appears, note down the full code, the time and the machine’s operating conditions.
- Contact CEMAS Elettra support: this may indicate a machine software version different from the one documented.
Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).
M20104-0.XX - Gate - Drive hardware fault
What this means: the field network diagnostics signal a hardware fault in the gate drive. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.
Probable causes:
- fault in the drive’s electronics;
- unstable logic power supply.
How to resolve:
- Read the Drive fault code in the drive diagnostics pop-up (i icon on the motor card) under Machine diagnostics > Motor status, Gates tab (Axis error code entry).
- Switch the machine off and on again in accordance with the user manual (maintenance technician).
- If the fault reoccurs, report the code to the service department.
Reset: the fault clears automatically once the fault has been rectified.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: only with Siemens or HDT motorised gates (Type).
Axis error code
How to identify it: the axis drive has encountered an error.
Check:
- In Machine Diagnostics > Motor Status, open the axis card and tap the i icon.
- Read and note down the error code (Drive fault code, Alarms word tab) displayed in the diagnostics pop-up.
Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the error recurs, report the code to CEMAS Elettra S.r.l. support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20105-0.XX – Gate – Drive alarm
What this means: there is a fault with the gate’s drive system (motor, encoder, power supply or movement). This is not signalled when the safety guards are open or the barrier is in alarm mode. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.
Probable causes:
- overload or obstructed movement;
- motor or drive overheating;
- damaged encoder or motor cables.
How to resolve:
- Read the Drive fault code in the drive diagnostics pop-up (i icon on the motor card) under Machine diagnostics > Motor status, Logs tab (Axis error code entry).
- Check that nothing is obstructing movement.
- Press Reset; if the error reoccurs, report the code to support.
Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: only with Siemens or HDT motorised gates (Type).
Axis error code
How to identify it: the axis drive has encountered an error.
Check:
- In Machine Diagnostics > Motor Status, open the axis card and tap the i icon.
- Read and note down the error code (Drive fault code, Alarms word tab) displayed in the diagnostics pop-up.
Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the error recurs, report the code to CEMAS Elettra S.r.l. support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20005-0.XX - Gate - Both position sensors
What this means: the sensors for the gate’s open and closed positions are active at the same time. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control signal withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.
Probable causes:
- faulty sensor or sensor constantly active (see Faulty sensors);
- sensors positioned so that both detect the gate (see Sensor positioning);
- sensor inputs set incorrectly.
How to resolve:
- Observe the LEDs on the two sensors whilst moving the gate by hand: each one should light up only when in its correct position (maintenance technician).
- Reposition or replace the sensor that remains lit.
- Check the inputs under Machine Settings > General Settings > Components, Gates tab (CEMAS technician).
Reset: clear by selecting Reset in the Alarm Monitor or by pressing the cycle start button, once the cause has been rectified.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.
Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).
Sensor positioning
How to identify this: the ‘open’ and ‘closed’ sensors are both lit.
Check:
- Move the gate and observe the LEDs: one should light up only when the gate is open, the other only when the gate is closed (maintenance technician).
Remedy: the maintenance technician repositions the sensor that detects both positions or replaces it if faulty.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20106-0.XX – Gate – Technical equipment alarm
What this means: the gate PLC’s motion control system has signalled an error, such as a tracking error or a software limit being exceeded. This error is not signalled when the safety guards are open or the barrier is in alarm mode. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.
Probable causes:
- movement braked or obstructed;
- actuator faulty or not ready.
How to resolve:
- Check the active bits in the Alarms word card in the drive diagnostics pop-up (the i icon on the motor card) under Machine diagnostics > Motor status, Gates tab (Axis status code entry).
- Resolve any other drive alarms.
- Press Reset and attempt a manual movement via Machine Diagnostics > Manual Movements, Machine tab > Clear.
Reset: stored alarm; clear by pressing Reset in the Alarm Monitor after rectifying the cause.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: only with Siemens or HDT motorised gates (Type).
Axis status coding
How to recognise it: the axis is stationary in alarm mode and its drive signals an abnormal status.
Check:
- In Machine Diagnostics > Motor Status, open the axis card and tap the i icon: the diagnostics pop-up displays the drive’s current statuses, errors and warnings.
- Make a note of the statuses and errors displayed.
Remedy: press Reset in the Alarm Monitor once the safety devices have been reset; if the fault persists, report the noted data to CEMAS Elettra support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20006-0.XX - Gate - Both commands
What this means: the gate opening and closing commands are active at the same time: the output configuration is inconsistent. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (command withdrawn, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold until the gate is in the required position.
Probable causes:
- Control outputs set incorrectly, for example, the same output used for both commands (see Resetting the commands).
How to resolve:
- Check the gate outputs under Machine settings > General settings > Components, Gates tab (CEMAS technician).
- Operate the gate manually via Machine diagnostics > Manual movements, Machine tab > Gates, and observe the movement.
Reset: press Reset in the Alarm Monitor or use the cycle start button once the cause has been rectified.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: appears if the gate is present (Machine settings > General settings > Components, Gates tab, Present).
Reset the controls
How to recognise it: an alarm is triggered by both commands being active, even if the gate is not moving.
Check:
- Check in Machine Settings > General Settings > Components, under the Gates tab, that opening and closing use different and correct outputs (CEMAS technician).
Remedy: the CEMAS technician corrects the outputs and tests the gate manually.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20107-0.XX - Gate - Positive overtravel alarm
What this means: the gate’s positive over-travel limit switch is active (if enabled): the shaft is beyond its working travel. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.
Probable causes:
- movement beyond the travel limit in manual mode or with movement constraints deactivated;
- lost or incorrect reference;
- limit switch faulty, out of alignment or disconnected (see Sensors not working).
How to resolve:
- Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab > Gates (see Release Overtravel).
- Whilst the axis is moving, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
- If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).
Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: only with Siemens or HDT motorised gates (Type).
Release the overrun
How to recognise this: the axis has reached the over-travel limit, beyond its normal travel; continuing would damage the machine.
Check:
- In Machine Diagnostics > Manual Movements, on the Machine tab, check the direction in which the axis has reached the overtravel limit.
- Check that the overtravel sensor is not faulty or misaligned.
Remedy: move the axis by hand in the opposite direction until the sensor is released, then press Reset; if the axis does not move, contact CEMAS Elettra S.r.l. support.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20007-0.XX – Gate – Unreferenced axis
What this means: the gate motor is powered but does not have a reference position: the position reading is unreliable. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.
Probable causes:
- motor, encoder or drive replaced (see Perform reset);
- reference lost following an encoder fault.
How to resolve:
- Check the Referenced indicator in Machine Diagnostics > Motor Status, Gates tab.
- With the machine in manual mode, reference the gate using Home position in Machine settings > General settings > Components, Gates tab (CEMAS technician).
Reset: this clears automatically after referencing.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: only with Siemens or HDT motorised gates (Type).
Perform a reset
How to identify the issue: under Machine Diagnostics > Motor Status, on the Gates tab, the gate’s Referenced indicator is grey.
Check:
- Check whether the gate’s motor, encoder or drive has been replaced.
Remedy: the CEMAS technician must re-reference the gate to the Home position in Machine Settings > General Settings > Components, under the Gates tab, whilst the machine is in manual mode.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20008-0.XX - Gate - Axis alarm
What this means: the gate axis is in alarm mode: on Siemens and HDT gates, an alarm is displayed in the axis details; on high-speed gates, the drive is in error mode. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the system to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.
Probable causes:
- fault in the gate actuator or motor (see Axis status coding);
- movement obstructed.
How to resolve:
- Check the detailed gate alarms in Machine status > Alarm monitor and follow the instructions.
- Check the drive status in the drive diagnostics pop-up (the i icon on the motor card) under Machine diagnostics > Motor status, Gates tab.
- Check that nothing is obstructing the gate.
Reset: clear the alarm by selecting Reset in the Alarm Monitor or by pressing the cycle start button once the cause has been rectified.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full error code, serial number, time of the alarm and checks carried out.
Availability: Machine option: available only with motorised gates (Type: Siemens, HDT or Velocità).
Axis status coding
How to recognise it: gate shaft alarm with no apparent cause.
Check:
- Open the drive diagnostics pop-up (the i icon on the motor card) in Machine Diagnostics > Motor Status, under the Gates tab.
- Read the active bits and the fault and warning codes.
Remedy: resolve the indicated cause; if it is unclear, report the codes to CEMAS Elettra support.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20108-0.XX - Gate - Negative overtravel alarm
What this means: the gate’s negative over-travel limit switch is active (if enabled): the shaft is beyond its operating travel. In the alarm code, XX indicates the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the machine to manual mode: the automatic cycle remains on hold, awaiting the gate to reach the required position.
Probable causes:
- movement beyond the travel limit in manual mode or with movement constraints deactivated;
- lost or incorrect reference;
- limit switch faulty, out of alignment or disconnected (see Sensors not working).
How to resolve:
- Release the limit switch by moving the axis manually in the opposite direction via Machine Diagnostics > Manual Movements, Machine tab > Gates (see Release Overtravel).
- Whilst the axis is moving, check that the limit switch LED goes out; if it remains lit, replace it (maintenance technician).
- If the value in Machine Diagnostics > Motor Status does not correspond to the actual position, have the axis re-referenced (CEMAS technician).
Reset: stored alarm; clear by selecting Reset in the Alarm Monitor after rectifying the cause (limit switch released).
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: only with Siemens or HDT motorised gates (Type).
Release the overrun
How to recognise this: the axis has reached the over-travel limit, beyond its normal travel; continuing would damage the machine.
Check:
- In Machine Diagnostics > Manual Movements, on the Machine tab, check the direction in which the axis has reached the overtravel limit.
- Check that the overtravel sensor is not faulty or misaligned.
Remedy: move the axis by hand in the opposite direction until the sensor is released, then press Reset; if the axis does not move, contact CEMAS Elettra S.r.l. support.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M20009-0.XX – Gate – Logic switch
What this means: the gate drive’s automatic switch (thermal logic) is open: the enabled input is low. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the system to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.
Probable causes:
- circuit breaker tripped due to overload or short circuit on the drive power supply (see Circuit breaker (thermal) tripped);
- circuit breaker opened for maintenance and not reset;
- auxiliary contact or input wiring broken.
How to resolve:
- In the electric panel, reset the gate logic circuit breaker (electrical maintenance technician).
- If it trips again, do not keep trying: check for a short circuit or overload on the cables, motor and drive.
- If the circuit breaker is closed but the alarm persists, check the auxiliary contact and the wiring.
Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using the Reset button.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: available only with motorised gates (Type: Siemens, HDT or Velocità).
M20010-0.XX - Gate - Power switch
What this means: the gate drive’s circuit breaker (thermal overload) has tripped: the enabled input is low. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the system to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.
Probable causes:
- circuit breaker tripped due to overload or short circuit on the motor or its cable (see Circuit breaker (thermal) tripped);
- circuit breaker opened for maintenance and not reset;
- auxiliary contact or input wiring broken.
How to resolve:
- In the electric panel, reset the gate’s main circuit breaker (maintenance technician).
- If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
- If the circuit breaker is closed but the alarm persists, check the auxiliary contact and the wiring.
Reset: the alarm clears automatically when the circuit breaker is closed again; other drive alarms are cleared using the Reset button.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: available only with motorised gates (Type: Siemens, HDT or Velocità).
M20011-0.XX - Gate - Breaker triggered
What this means: the circuit breaker supplying power to the gate motor brake has tripped: the enabled input is low. In the alarm code, XX refers to the gate (also named in the text): 01 front, 02 rear.
Effect: Alarm (red line). Gate stopped (control signal removed, motor disabled). Does not switch the system to manual mode: the automatic cycle remains on hold whilst the gate is in the required position.
Probable causes:
- circuit breaker tripped due to overload or short circuit on the brake or its cable (see Circuit breaker (thermal) tripped);
- circuit breaker opened for maintenance and not reset;
- auxiliary contact or input wiring broken.
How to resolve:
- In the electric panel, reset the gate brake circuit breaker (electrical maintenance technician).
- If it trips again, do not persist: check for a short circuit or overload on the cables, motor and drive.
- If the circuit breaker is closed but the fault indication persists, check the auxiliary contact and the wiring.
Reset: the fault clears automatically when the circuit breaker is closed again; other drive alarms are cleared using the Reset button.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: available only with motorised gates (Type: Siemens, HDT or Velocità).
Transducer system
Alarms from the transducer system, the linear position sensors that measure the height of the table (and the head, where fitted) during welding: status of the left and right units and misalignment between the transducers on the same axis.
The positions and misalignment can be viewed under Machine Diagnostics > Transducers; the limits are set under Machine Settings > General Settings > Components, on the Transducers tab.
Availability: Machine option: appears if position transducers are configured; this option is configured by CEMAS.
M21000-0.XX – Transducer system – Left-hand unit alarm
What this means: At least one of the transducers on the left-hand side (top or bottom) is in alarm mode: this is the summary for the left-hand unit.
Effect: The alert is not displayed in the Alarm Monitor: the height is invalid, so an ongoing welding process is interrupted (rejected part) and the machine switches to Manual mode. The line visible in the Alarm Monitor is that of the individual transducer, showing its number.
Probable causes:
- transducer not powered;
- network or power cable disconnected or damaged.
How to resolve:
- On the Machine Status > Alarm Monitor page, check the alarm for transducer 01 (top left) or 02 (bottom left) and follow the procedure.
Reset: once the cause has been rectified, select Reset in the Alarm Monitor.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Transducer connection
How to identify the problem: the transducer is not communicating: under Machine Diagnostics > Transducers, the reading is missing or is not updating.
Check:
- Check the transducer’s power cable and Profinet network cable.
- Check the transducer’s LEDs.
Remedy: Reconnect or replace any damaged cables (maintenance technician).
Check the magnet
How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.
Check:
- Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
- Check that the transducer magnet and rod are clean and undamaged.
Remedy: clean, reposition or replace the magnet (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M21001-0.XX - Transducer system - Right-hand unit alarm
What this means: At least one of the transducers on the right-hand side (top or bottom) is in alarm mode: this is the summary for the right-hand unit.
Effect: The alert is not displayed in the Alarm Monitor: the height is invalid, so ongoing welding is interrupted (rejected part) and the machine switches to Manual mode. The line visible in the Alarm Monitor is that of the individual transducer, showing its number.
Probable causes:
- transducer not powered;
- network or power cable disconnected or damaged.
How to resolve:
- On the Machine Status > Alarm Monitor page, check the alarm for transducer 03 (top right) or 04 (bottom right) and follow the procedure.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Transducer connection
How to identify the problem: the transducer is not communicating: under Machine Diagnostics > Transducers, the reading is missing or is not updating.
Check:
- Check the transducer’s power cable and Profinet network cable.
- Check the transducer’s LEDs.
Remedy: Reconnect or replace any damaged cables (maintenance technician).
Check the magnet
How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.
Check:
- Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
- Check that the transducer magnet and rod are clean and undamaged.
Remedy: clean, reposition or replace the magnet (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M21002-0.XX – Transducer system – Maximum head misalignment error
What this means: With transducers on both sides, the difference between the readings of the upper (head) transducers exceeds the Maximum head misalignment error (typically 0.5 millimetres, mm) in Machine settings > General settings > Components, under the Transducers tab. Check is always active; remains stored.
Effect: alert not displayed in the Alarm Monitor: the height is invalid, so a welding operation in progress is interrupted (rejected part) and the machine switches to Manual mode. There is no dedicated line in the Alarm Monitor.
Probable causes:
- magnet or transducer loose or displaced;
- head not parallel.
How to resolve:
- In Machine Diagnostics > Transducers, compare the high measurements with the Head misalignment error card.
- Check that the head’s magnets and transducers are securely fastened (maintenance technician).
- If the discrepancy persists, have the head’s parallelism checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Check the magnet
How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.
Check:
- Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
- Check that the transducer magnet and rod are clean and undamaged.
Remedy: clean, reposition or replace the magnet (by a maintenance technician).
Check the installation
How to identify the problem: the reading for a transducer under Machine Diagnostics > Transducers is different from the expected value or from that of the other side, or the transducer is signaling a fault.
Check:
- With the machine in a safe state, check that the transducer is securely fastened and aligned with the axis.
- Check that the magnets are secured, clean and at the correct distance from the transducer.
- Once the machine is back in service, move the axis and check in Machine Diagnostics > Transducers that the position changes smoothly.
Remedy: secure or reposition the transducer and magnets (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M21003-0.XX – Transducer system – Maximum misalignment error: Table
What this means: With transducers on both sides, the difference between the readings from the lower transducers (table) exceeds the Maximum table misalignment error (typically 0.5 millimetres, mm) in Machine settings > General settings > Components, under the Transducers tab. Check always active; remains stored.
Effect: Alarm (red line): the height is invalid, so a welding operation in progress is interrupted (scrap part) and the machine switches to Manual mode.
Possible causes:
- magnet or transducer loose or displaced;
- table not parallel.
How to resolve:
- In Machine Diagnostics > Transducers, compare the lower dimensions with the Table misalignment error card, whilst moving the table by hand.
- Check that the magnets and transducers on the table are securely fixed (maintenance technician).
- If the discrepancy persists, have the table checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Check the magnet
How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.
Check:
- Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
- Check that the transducer magnet and rod are clean and undamaged.
Remedy: clean, reposition or replace the magnet (by a maintenance technician).
Check the installation
How to identify the problem: the reading for a transducer under Machine Diagnostics > Transducers is different from the expected value or from that of the other side, or the transducer is signaling a fault.
Check:
- With the machine in a safe state, check that the transducer is securely fastened and aligned with the axis.
- Check that the magnets are secured, clean and at the correct distance from the transducer.
- Once the machine is back in service, move the axis and check in Machine Diagnostics > Transducers that the position changes smoothly.
Remedy: secure or reposition the transducer and magnets (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Transducer unit
Alarms for the left and right transducer units: these summarise the status of the upper and lower transducers on each side.
Availability: Machine option: appears if the position transducers are configured; this option is configured by CEMAS.
M22000-0.XX – Transducer unit – Upper transducer alarm
What this means: The high transducer for the specified unit is in alarm; check this when the corresponding side also shows a high reading. In the code, XX indicates the unit: 01 left, 02 right.
Effect: alert not displayed in the Alarm Monitor: the level is invalid, so an ongoing welding process is interrupted (rejected part) and the machine switches to Manual mode. The line visible in the Alarm Monitor is that of the individual transducer, showing its number.
Probable causes:
- transducer not powered;
- network or power cable disconnected or damaged.
How to resolve:
- On the Machine Status > Alarm Monitor page, check the alarm for transducer 01 (top left) or 03 (top right) and follow the procedure.
Reset: the alarm clears automatically once the transducer is no longer in alarm mode.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Transducer connection
How to identify the problem: the transducer is not communicating: under Machine Diagnostics > Transducers, the reading is missing or is not updating.
Check:
- Check the transducer’s power cable and Profinet network cable.
- Check the transducer’s LEDs.
Remedy: Reconnect or replace any damaged cables (maintenance technician).
Check the magnet
How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.
Check:
- Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
- Check that the transducer magnet and rod are clean and undamaged.
Remedy: clean, reposition or replace the magnet (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M22001-0.XX - Transducer unit - Lower transducer alarm
What this means: The lower transducer in the specified unit is in alarm. In the code, XX indicates the unit: 01 left, 02 right.
Effect: the message is not displayed in the Alarm Monitor: the height is invalid, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode. The line visible in the Alarm Monitor is that of the individual transducer, showing its number.
Probable causes:
- transducer not powered;
- network or power cable disconnected or damaged.
How to resolve:
- On the Machine Status > Alarm Monitor page, check the alarm for transducer 02 (bottom left) or 04 (bottom right) and follow the procedure.
Reset: the alarm clears automatically once the transducer is no longer in alarm mode.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Transducer connection
How to identify the problem: the transducer is not communicating: under Machine Diagnostics > Transducers, the reading is missing or is not updating.
Check:
- Check the transducer’s power cable and Profinet network cable.
- Check the transducer’s LEDs.
Remedy: Reconnect or replace any damaged cables (maintenance technician).
Check the magnet
How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.
Check:
- Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
- Check that the transducer magnet and rod are clean and undamaged.
Remedy: clean, reposition or replace the magnet (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Transducer
Alarms for individual position transducers: network communication, faults, full-scale and position reading. The element number identifies the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right. The values can be viewed under Machine Diagnostics > Transducers.
Availability: Machine option: appears if the position transducers are configured; this option is configured by CEMAS.
M23000-0.XX – Transducer – Not accessible
What this means: The PLC is unable to access the transducer via the network. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).
Effect: Alarm (red line): the height is invalid, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode.
Probable causes:
- transducer not powered;
- network or power cable disconnected or damaged;
- faulty network switch.
How to resolve:
- Check in Machine Diagnostics > PLC, under the PLC Hardware tab, whether the transducer is showing an error.
- Check the power supply, network LED, cables and connectors of the transducer (maintenance technician).
- Press Reset.
Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Transducer connection
How to identify the problem: the transducer is not communicating: under Machine Diagnostics > Transducers, the reading is missing or is not updating.
Check:
- Check the transducer’s power cable and Profinet network cable.
- Check the transducer’s LEDs.
Remedy: Reconnect or replace any damaged cables (maintenance technician).
Check the magnet
How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.
Check:
- Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
- Check that the transducer magnet and rod are clean and undamaged.
Remedy: clean, reposition or replace the magnet (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M23001-0.XX – Transducer – Hardware fault
What this means: The transducer is sending signals indicating a fault in its electronics. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (01 to 04).
Effect: Alarm (red line): the height is invalid, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode.
Probable causes:
- faulty transducer;
- damaged or incorrectly fitted transducer.
How to resolve:
- Check the fixing and integrity of the transducer and magnet (maintenance technician).
- Switch the machine off and on again, then press Reset.
- If the fault persists, replace the transducer (CEMAS technician).
Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Check the installation
How to identify the problem: the reading for a transducer under Machine Diagnostics > Transducers is different from the expected value or from that of the other side, or the transducer is signaling a fault.
Check:
- With the machine in a safe state, check that the transducer is securely fastened and aligned with the axis.
- Check that the magnets are secured, clean and at the correct distance from the transducer.
- Once the machine is back in service, move the axis and check in Machine Diagnostics > Transducers that the position changes smoothly.
Remedy: secure or reposition the transducer and magnets (by a maintenance technician).
Check the magnet
How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.
Check:
- Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
- Check that the transducer magnet and rod are clean and undamaged.
Remedy: clean, reposition or replace the magnet (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M23002-0.XX - Transducer - Mains fault
What this means: The transducer is signaling a network error: communication disruption or device not configured correctly. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).
Effect: Alarm (red line): the height is invalid, so any welding in progress is interrupted (scrap piece) and the machine switches to Manual mode.
Probable causes:
- faulty network cable or switch;
- transducer replaced but not configured.
How to resolve:
- Check the cable, connectors and LEDs on the switch port (maintenance technician).
- If the transducer has been replaced, have its network configuration checked (CEMAS technician).
- Press Reset.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M23003-0.XX - Transducer - Full scale reached
What this means: The transducer returns a value outside the measurement range, usually because it cannot detect the magnet. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).
Effect: Alarm (red line): the position is invalid, so any welding in progress is interrupted (scrap piece) and the machine switches to Manual mode.
Probable causes:
- magnet missing, detached or too far away;
- faulty wiring.
How to resolve:
- Check the transducer reading in Machine Diagnostics > Transducers: an out-of-range value confirms the alarm.
- Check the magnet (present, clean, at the correct distance) and the wiring (maintenance technician).
- Press Reset.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Check the magnet
How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.
Check:
- Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
- Check that the transducer magnet and rod are clean and undamaged.
Remedy: clean, reposition or replace the magnet (by a maintenance technician).
Check the assembly
How to identify this: the transducer reading under Machine Diagnostics > Transducers is out of range or missing.
Check:
- With the machine in a safe state, check the position and alignment of the magnet relative to the transducer.
- Check that the transducer’s electrical wiring is intact and that the connectors are securely fitted.
Remedy: reposition the magnet or replace the damaged cable (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M23004-0.XX – Transducer – Device in activation mode
What this means: The transducer has not completed its network activation. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).
Effect: Alarm (red line): the height is invalid, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode.
Probable causes:
- transducer still starting up;
- transducer replaced but not configured;
- unstable power supply or mains supply.
How to resolve:
- Wait a few seconds and press Reset.
- If the problem recurs, check the power supply and network cable (maintenance technician).
- If the transducer has been replaced, have its configuration checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M23005-0.XX – Transducer – Second position illegible
What this means: The top transducer, configured to read two positions (two magnets on the same transducer), is not providing the second position. Checked only in this configuration; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).
Effect: Alarm (red line): the height is invalid, so a welding operation in progress is interrupted (scrap piece) and the machine switches to Manual mode.
Probable causes:
- single-position transducer fitted instead of a dual-position one;
- second magnet missing or out of range;
- transducer not accessible on the network.
How to resolve:
- Check that the transducer is the specified two-position type (maintenance technician).
- Check the presence and secure fixation of the second magnet.
- Press Reset; if the fault recurs, have the configuration checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
Check the magnet
How to identify the problem: the transducer reading in Machine Diagnostics > Transducers is missing, skips or remains static whilst the axis is moving.
Check:
- Check that the transducer magnet is securely fixed and at the distance specified in the transducer manual.
- Check that the transducer magnet and rod are clean and undamaged.
Remedy: clean, reposition or replace the magnet (by a maintenance technician).
Check the installation
How to identify the problem: the reading for a transducer under Machine Diagnostics > Transducers is different from the expected value or from that of the other side, or the transducer is signaling a fault.
Check:
- With the machine in a safe state, check that the transducer is securely fastened and aligned with the axis.
- Check that the magnets are secured, clean and at the correct distance from the transducer.
- Once the machine is back in service, move the axis and check in Machine Diagnostics > Transducers that the position changes smoothly.
Remedy: secure or reposition the transducer and magnets (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M23006-0.XX – Transducer – Fixed value
What this means: The transducer value (resolution 0.001 millimetres, mm) remains unchanged for 500 milliseconds (ms): the reading appears to be stuck. Also checked whilst the machine is stationary, with a position other than zero. Checked 7 seconds (s) after power-up; the alarm remains stored. In the code, XX refers to the transducer: 01 top left, 02 bottom left, 03 top right, 04 bottom right (from 01 to 04).
Effect: Alarm (red line): the height is invalid, so any welding in progress is interrupted (rejected part) and the machine switches to Manual mode.
Probable causes:
- communication blocked;
- magnet detached or not securely attached to the axis.
How to resolve:
- Move the axis by hand and check in Machine Diagnostics > Transducers that the position changes.
- If it does not change, check the magnet, transducer and power cable (maintenance technician).
- Press Reset; if the fault recurs, have the transducer checked (CEMAS technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the position transducers are configured; this option is configured by CEMAS.
SmartAccessory
Alarms from the Smart accessory, the external device with its own PLC connected to the welding machine (conveyor systems, traceability, robots). Details of the alarms can be found in the Smart accessory tab on the Machine status > Alarm monitor page and on the Machine diagnostics > Smart accessory page.
Availability: machine option: only available if the Smart accessory is present; option configured by CEMAS.
M24000-0.XX - SmartAccessory - Communication alarm
What this means: The Smart Accessory is no longer responding: the communication status signal has been static for 5 seconds.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Possible causes:
- the Smart Accessory’s network or power cable is disconnected (Smart Accessory Connection);
- the Smart Accessory is switched off or frozen.
How to resolve:
- Check that the Smart Accessory is switched on.
- Check the network cable and the communication LEDs.
- Open the Machine Diagnostics > Smart Accessory page: if a message stating that the device is unreachable appears, the connection has been lost.
Resolution: the message disappears automatically once the issue has been resolved.
Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.
Smart Accessory Connection
How to identify the issue: The Smart accessory is not communicating and the Machine Diagnostics > Smart accessory page does not load.
Check:
- Check that the Smart accessory is powered up and switched on.
- Check the network cable and the communication LEDs at both ends.
Remedy: Reconnect or replace the cable; restart the Smart accessory (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M24001-0.XX - SmartAccessory - Offline
What this means: The Smart Accessory is disconnected from the welding machine’s PLC.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.
Probable causes:
- Power cable disconnected or damaged (Smart Accessory connection);
- Smart accessory switched off.
How to resolve:
- Check the power supply and ensure the Smart Accessory is switched on.
- Check the network cable and connectors (maintenance technician).
Resolution: the error clears automatically once the issue has been resolved.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.
Smart Accessory Connection
How to identify the issue: The Smart accessory is not communicating and the Machine Diagnostics > Smart accessory page does not load.
Check:
- Check that the Smart accessory is powered up and switched on.
- Check the network cable and the communication LEDs at both ends.
Remedy: Reconnect or replace the cable; restart the Smart accessory (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M24002-0.XX - SmartAccessory - Unsupported version
What this means: the Smart Accessory software version is not supported by the welding machine: either the major version is different, or the minor version is older than the one required.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.
Probable causes:
- Smart accessory programme not up to date (Update Smart Accessory version).
How to resolve:
- Note down the PLC Release in Machine Diagnostics > Support.
- Request an update for the Smart Accessory (CEMAS technician).
Resolution: the issue resolves itself once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.
Update Smart Accessory version
How to recognise it: the message Unsupported version appears immediately after connecting the Smart accessory.
Check:
- Make a note of the PLC release under Machine diagnostics > Support.
- Note down the version of the Smart accessory from the Machine Diagnostics > Smart accessory page, if available.
Remedy: request an update for the Smart accessory from CEMAS Elettra support (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M24003-0.XX - SmartAccessory - Machine version not supported
What this means: The Smart accessory reports that it does not support the welding machine’s software version.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.
Probable causes:
- Welding machine software is not compatible (Update the welding machine PLC version).
How to resolve:
- Note down the PLC Release in Machine Diagnostics > Support.
- Request a software update (CEMAS technician).
Resolution: the alarm clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.
Update the PLC version of the welding machine
How to recognise it: the message ‘Machine version not supported’ appears immediately after connecting the Smart accessory.
Check:
- Note down the PLC release under Machine diagnostics > Support.
Remedy: the welding machine’s software must be updated by CEMAS Elettra personnel: contact support (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M24004-0.XX - SmartAccessory - Transport System Error
What this means: The Smart Accessory signals an alarm from the transport system (e.g. a workpiece conveyor) that it controls.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.
Probable causes:
- Conveyor system fault.
How to resolve:
- Check the details in the Smart accessory tab on the Machine status > Alarm monitor page and on the Machine diagnostics > Smart accessory page.
- Resolve the fault on the specified device, in accordance with its documentation.
- Check that the alert disappears.
Reset: the alert disappears automatically once the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.
M24005-0.XX - SmartAccessory - Traceability error
What this means: The Smart Accessory signals an alarm from the traceability system (e.g. barcode readers or label printers).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.
Probable causes:
- traceability system fault.
How to resolve:
- Check the details in the Smart accessory tab on the Machine status > Alarm monitor page and on the Machine diagnostics > Smart accessory page.
- Resolve the fault on the specified device, in accordance with its documentation.
- Check that the alert disappears.
Reset: the alert clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.
M24006-0.XX - SmartAccessory - Robot error
What this means: The Smart Accessory signals an alarm from the robot it controls.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.
Probable causes:
- robot fault or shutdown.
How to resolve:
- Check the details in the Smart accessory tab on the Machine status > Alarm monitor page and on the Machine diagnostics > Smart accessory page.
- Resolve the fault on the specified device, in accordance with its documentation.
- Check that the alert disappears.
Reset: the alert disappears automatically once the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.
M24007-0.XX - SmartAccessory - General
What this means: The Smart Accessory is triggering a general alarm, not related to transport, traceability or robots.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain locked.
Probable causes:
- Internal fault in the Smart accessory.
How to resolve:
- Check the details in the Smart accessory tab on the Machine status > Alarm monitor page and on the Machine diagnostics > Smart accessory page.
- Resolve the fault on the specified device, in accordance with its documentation.
- Check that the alert disappears.
Resolution: the alert disappears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: only available if the Smart accessory is fitted; option configured by CEMAS.
Welding cycle
Welding alarms: values from the last cycle are outside the limits set in Equipment Settings > Welding Parameters, under the Welding Limits panel. Each alarm results in the workpiece being rejected and prevents the next cycle from starting until a Reset is performed.
M25000-0.XX - Welding cycle - Lower limit of welding time not exceeded
What this means: the Welding time for the last cycle is less than the Lower limit set in Equipment settings > Welding parameters, Welding limits panel: the weld reached the end depth too early. On IR and HP machines, this refers to the joining phase following preheating (the cooling lines on the panel).
Effect: Warning (yellow line). The workpiece is declared a scrap piece (reason shown on the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In test cycles, the limits are not monitored.
Probable causes:
- workpieces with excess material or incorrectly positioned, which reach the depth immediately;
- lower limit set too high (Welding time configuration setting).
How to resolve:
- Check parts and tools: ensure parts are correct, fully inserted, and that there are no previously welded parts or foreign objects (see Check tools).
- Compare the time shown in Last cycle results with the limits in Tool settings > Welding parameters, under the Welding limits panel.
- If the parts are sound and the time is stable, ask the tool manager to adjust the limit.
Reset: clear the alarm using Reset in the Alarm Monitor; check the rejected part before restarting.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Welding time settings
How to identify it: the variation in welding time recurs with good parts and a stable welding time.
Check:
- Compare the Welding time in Last cycle results with the Lower limit and Upper limit in Tool settings > Welding parameters, Welding limits panel.
Remedy: the tool manager corrects the limits based on the good parts.
Check tools
How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.
Check:
- Check that the tool is undamaged and correctly assembled.
- Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
- Check that the parts are the correct ones.
Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M25001-0.XX - Welding cycle - Upper limit of welding time reached
What this means: the Welding time has reached the Upper limit set in Tool settings > Welding parameters, under the Welding limits panel: welding is stopped immediately. On machines with vibration, the limit cannot exceed the VCU’s vibration time-out. On IR and HP machines, it refers to the joining phase following heating (the cooling lines on the panel).
Effect: Warning (yellow line). The workpiece is declared a reject (reason shown in the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In vacuum cycles, the limits are not monitored.
Probable causes:
- parts that do not melt or sink as expected;
- insufficient force, amplitude or power;
- upper limit set too low (Welding time configuration setting).
How to resolve:
- Check the parts and tools: correct parts, fully inserted, no previously welded parts or foreign objects (see Check tools).
- Check the tools’ welding parameters.
- If the parts are sound and the time is stable, have the limit adjusted in Tool Settings > Welding Parameters, under the Welding Limits panel.
Reset: clear the alarm using Reset in the Alarm Monitor; check the scrap piece before restarting.
If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.
Welding time settings
How to identify it: the variation in welding time recurs with good parts and a stable welding time.
Check:
- Compare the Welding time in Last cycle results with the Lower limit and Upper limit in Tool settings > Welding parameters, Welding limits panel.
Remedy: the tool manager corrects the limits based on the good parts.
Check tools
How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.
Check:
- Check that the tool is undamaged and correctly assembled.
- Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
- Check that the parts are the correct ones.
Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M25002-0.XX – Welding cycle – Lower limit of welding start position not exceeded
What this means: the Welding Start Position is below the Lower Limit set in Equipment Settings > Welding Parameters, under the Welding Limits panel: the workpieces have come into contact lower down than expected. The check takes place at the end of stabilisation and then continuously: if out of limit, welding will not start or will be interrupted.
Effect: Warning (yellow line). The workpiece is declared a reject (reason shown in the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. During test cycles, the limits are not monitored.
Probable causes:
- workpiece missing, shorter than required or not fully inserted;
- tools different from those specified in the loaded parameters;
- lower limit set too high (under Welding start position configuration).
How to resolve:
- Check workpieces and tools: ensure the correct workpieces are used, fully inserted, and that there are no previously welded workpieces or foreign objects (under Check tools).
- Compare the position in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Reset: clear by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.
If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.
Setting the welding start position
How to identify it: the deviation in the welding start position recurs in good parts.
Check:
- Compare the Welding start position in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Remedy: the tool manager corrects the limits based on the good parts.
Check tools
How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.
Check:
- Check that the tool is undamaged and correctly assembled.
- Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
- Check that the parts are the correct ones.
Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M25003-0.XX - Welding cycle - Upper limit of welding start position reached
What this means: the Welding Start Position has reached the Upper Limit set in Equipment Settings > Welding Parameters, under the Welding Limits panel: the workpieces have come into contact higher up than expected. The check takes place at the end of stabilisation and then continuously: if the limit is exceeded, welding will not start or will be interrupted.
Effect: Warning (yellow line). The workpiece is declared a reject (reason shown in the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. During idle cycles, the limits are not monitored.
Probable causes:
- workpiece is too high, duplicated or has already been welded;
- foreign object in the tools;
- upper limit set too low (under Welding start position configuration).
How to resolve:
- Check workpieces and tools: correct workpieces, fully inserted, no previously welded workpieces or foreign objects (under Check tools).
- Compare the height in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Reset: clear by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.
Setting the welding start position
How to identify it: the deviation in the welding start position recurs in good parts.
Check:
- Compare the Welding start position in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Remedy: the tool manager corrects the limits based on the good parts.
Check tools
How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.
Check:
- Check that the tool is undamaged and correctly assembled.
- Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
- Check that the parts are the correct ones.
Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M25004-0.XX - Welding cycle - Lower limit of the end-of-weld position not reached
What this means: the End-of-weld position (average position of the table at the end of cooling) is below the Lower limit set in Equipment settings > Welding parameters, under the Welding limits panel.
Effect: Warning (yellow line). The workpiece is declared a scrap piece (reason shown on the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In idle cycles, the limits are not monitored.
Probable causes:
- excessive depth;
- workpieces shorter than expected;
- lower limit set too high (Welding end position configuration setting).
How to resolve:
- Check workpieces and tools: correct workpieces, fully inserted, no previously welded workpieces or foreign objects (see Check tools).
- Check the welding parameters.
- Compare the height in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Reset: reset by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.
If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.
Setting the end-of-welding position
How to identify it: the deviation in the end-of-welding height recurs in good parts.
Check:
- Compare the End-of-weld dimension in Last welding cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Remedy: the tool manager corrects the limits based on the good parts.
Check tools
How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.
Check:
- Check that the tool is undamaged and correctly assembled.
- Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
- Check that the parts are the correct ones.
Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M25005-0.XX - Welding cycle - Upper limit of the end-of-weld position reached
What this means: the End-of-weld position (average position of the table at the end of cooling) has reached the Upper limit set in Equipment settings > Welding parameters, under the Welding limits panel.
Effect: Warning (yellow line). The workpiece is declared a scrap piece (reason shown in the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In dry runs, the limits are not monitored.
Probable causes:
- insufficient depth;
- workpieces taller than expected or foreign objects;
- upper limit set too low (Welding End Height Configuration setting).
How to resolve:
- Check the workpieces and tools: ensure the correct workpieces are used, that they are fully inserted, and that there are no previously welded workpieces or foreign objects (see Check tools).
- Check the welding parameters.
- Compare the height in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Reset: reset by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.
If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.
Setting the end-of-welding position
How to identify it: the deviation in the end-of-welding height recurs in good parts.
Check:
- Compare the End-of-weld dimension in Last welding cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Remedy: the tool manager corrects the limits based on the good parts.
Check tools
How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.
Check:
- Check that the tool is undamaged and correctly assembled.
- Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
- Check that the parts are the correct ones.
Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M25006-0.XX – Welding cycle – Lower limit of welding depth not exceeded
What this means: the Weld depth (the difference between the position at the end of cooling and the welding start position) is below the Lower limit set in Tool settings > Welding parameters, under the Welding limits panel: the workpieces have not been submerged deeply enough.
Effect: Warning (yellow line). The workpiece is declared a reject (reason shown in the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In dry runs, the limits are not monitored.
Probable causes:
- insufficient welding time, energy or force;
- non-compliant workpieces;
- lower limit set too high (Welding Depth Configuration setting).
How to resolve:
- Check workpieces and tools: correct workpieces, fully inserted, no previously welded workpieces or foreign objects (see Check tools).
- Check the welding parameters.
- Compare the depth in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Reset: clear by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.
If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.
Welding depth settings
How to identify it: the variation in welding depth is consistent across good parts.
Check:
- Compare the Welding depth in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Remedy: the tool manager corrects the limits based on the good parts.
Check tools
How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.
Check:
- Check that the tool is undamaged and correctly assembled.
- Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
- Check that the parts are the correct ones.
Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M25007-0.XX - Welding cycle - Upper limit of welding depth reached
What this means: the Weld depth (the difference between the position at the end of cooling and the welding start position) has reached the Upper limit set in Equipment settings > Welding parameters, under the Welding limits panel: the workpieces have sunk too far.
Effect: Warning (yellow line). The workpiece is declared a scrap piece (reason shown on the Welding Result card under Machine Status > CONTROL PAGE). The machine does not switch to manual mode, but the next cycle will not start until the warning is cleared. In idle cycles, the limits are not monitored.
Probable causes:
- excessive welding time, energy or force;
- non-compliant workpieces;
- upper limit set too low (Welding depth configuration setting).
How to resolve:
- Check workpieces and tools: correct workpieces, fully inserted, no previously welded workpieces or foreign objects (see Check tools).
- Check the welding parameters.
- Compare the depth in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Reset: clear by selecting Reset in the Alarm Monitor; check the scrap piece before restarting.
If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.
Welding depth settings
How to identify it: the variation in welding depth is consistent across good parts.
Check:
- Compare the Welding depth in Last cycle results with the limits in Tool settings > Welding parameters, Welding limits panel.
Remedy: the tool manager corrects the limits based on the good parts.
Check tools
How to recognise it: defects appear randomly or following an impact, maintenance or a tool change.
Check:
- Check that the tool is undamaged and correctly assembled.
- Check that there are no previously welded parts, scrap metal or foreign objects in the cavities.
- Check that the parts are the correct ones.
Remedy: the operator cleans the cavities and repositions the parts; damaged tools must be repaired by the person responsible for the tools.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Door
Alarms relating to the machine’s doors (up to ten): door not closed or not locked. These are configured under Machine Settings > General Settings > Components, on the Doors tab.
M26000-0.XX - Door - Unlocked
What this means: the door has been closed for more than 1 s but its electric lock has not been reset: the unlocking, initiated manually or during a tool change using Door Unlock (in the Quick Actions menu on the control panel), is still active. In the code, XX is the door number (from 01 to 10).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- lock not reset after opening;
- door not fully closed (Door locking);
- faulty electric lock or sensor (Sensors not working).
How to resolve:
- Close the door fully.
- Tap Door Unlock to reset the lock: when the doors are closed and locked, the padlock icon is grey.
- If the lock does not reset: check the electric lock and sensor (maintenance technician).
Reset: disappears automatically when the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: only for doors with unlock and reset controls, configured by CEMAS in Machine Settings > General Settings > Components, Doors tab.
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Door locking
How to recognise this: the door appears to be closed, but the machine does not detect it as closed or locked.
Check:
- Open the door and close it firmly until it stops.
- Check the Door Unlock indicator (in the Quick Actions menu on the dashboard): it should be grey when all doors are closed and locked.
Remedy: if the warning persists after closing, see Faulty sensors or Door functionality.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M26001-0.XX – Door – Not closed
What this means: once the emergency has been reset, the door does not remain closed for more than 1 s. In the code, XX is the door number (from 01 to 10).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- door open or not fully closed (Door locking);
- closure sensor displaced or faulty (Sensors not working);
- worn hinges or latches (Door functionality).
How to resolve:
- Close the door fully.
- Check the Door Unlock lock (Quick Actions menu on the frame): green when at least one door is open.
- If the door is closed but appears open: check the sensor and strike plate (maintenance technician).
Reset: disappears automatically when the condition no longer applies.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the door is fitted (Machine settings > General settings > Components, Doors tab), option configured by CEMAS.
Door functions
How to identify the problem: the door closes with difficulty, has play or does not reach the sensor.
Check:
- Check the hinges, guides and door stop.
- Check that the closing sensor is securely fixed and aligned with the door stop.
Remedy: adjust or replace worn components (by a maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Door locking
How to recognise this: the door appears to be closed, but the machine does not detect it as closed or locked.
Check:
- Open the door and close it firmly until it stops.
- Check the Door Unlock indicator (in the Quick Actions menu on the dashboard): it should be grey when all doors are closed and locked.
Remedy: if the warning persists after closing, see Faulty sensors or Door functionality.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Safety feature
Alarms from safety devices (emergency, light curtains, gates, safety edges, doors) have not been reset. These can be configured under Machine Settings > General Settings > Components, on the Safety tab.
M27000-0.XX – Light curtain – Not reset
What this means: the XX safety device has not been reset for at least 0.5 s and has not been bypassed. XX: 01 emergency, 02–03 front and rear safety barriers, 04–05 front gate and rear gate, 06–07 front and rear gate safety edges, 08–17 doors 1 to 10.
Effect: Alarm (red line): in the case of emergency, safety edges and doors, the machine switches to manual mode; the automatic cycle and tool change remain blocked. The barriers only lock during the cycle when the gate is not closed; for gates, this is merely an indication.
Probable causes:
- device obstructed, open or pressed (Reset the light curtain);
- light curtain misaligned (Check alignment) or damaged (Light curtain functionality).
How to resolve:
- Disengage the emergency stop, close doors and gates, clear the barrier, then reset the safety devices.
- If the barrier remains in alarm mode: clean it and check its alignment and error codes (maintenance technician).
Emergency restore: edges and doors clear automatically upon restore; barriers via Reset.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the safety device is fitted (Machine settings > General settings > Components, Safety tab), option configured by CEMAS.
Functions of light curtains
How to identify the problem: the barrier remains in alarm mode even when there are no obstacles, or the LEDs indicate a fault.
Check:
- Check that the lenses are clean and undamaged.
- Check the LEDs and any error codes displayed by the barrier.
Remedy: clean the lenses with an anti-static cloth; replace any damaged components (by a maintenance technician).
Check alignment
How to recognise it: the light curtain is interrupted without any obstacles or intermittently, for example following an impact.
Check:
- Check the alignment between the transmitter and receiver using the light curtain’s indicators.
- Check that the brackets are not loose.
Remedy: realign the light barrier in accordance with its manual (maintenance technician).
Reset the light curtain
How to recognise this: the safety device has been triggered and has not been reset.
Check:
- Check that no object or person is obstructing the barrier.
- Check that emergency exits, doors and gates have been reset.
Remedy: clear the barrier, reset the safety devices in accordance with the user manual and press Reset on the Alarm Monitor.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Sliding plane
Alarms for the sliding table, which moves the tools between the loading, welding, undercut and tool change positions: axis and drive, positions and shutter (clamp).
The table is configured under Machine Settings > General Settings > Components, on the Sliding Table tab, and is controlled manually via Machine Diagnostics > Manual Movements, under the Machine tab > Axes > Sliding Table.
Availability: only on models with a sliding table (950-ST, 950-HL, 999-HL, 999-XT). Machine option: appears if the Sliding Table is present (Machine Settings > General Settings > Components, Sliding Table tab, Present).
Tool connector
Alarms relating to the 64-pin tool connectors, in the IO-Link or GVX version, through which the welding machine communicates with the input and output modules fitted to the tool: device not configured, unreachable or faulty. The pin status can be viewed under Tool Change > Tool Change, on the Pin Decoding tab.
The connectors are configured under Machine Settings > General Settings > Tool Interfaces, in the zone tab, under the Connectors tab.
M29100-2.XX - Table - 64-pin tool connectors - Device not configured
What this means: The tool’s IO-Link module connected to the table’s 64-pin connector is not configured on the PLC network. Checked with the IO-Link connector selected and the tool present.
Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- New or replaced device not yet configured;
- Machine configuration not up to date.
How to resolve:
- Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
- Have the device configured (by a CEMAS technician).
Reset: the error clears automatically once the device returns to normal operation.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears with the IO-Link connector; option configured by CEMAS.
Configure device
How to recognise it: the alarm appears as soon as a new tool is connected or after the connector module has been replaced.
Check:
- Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
- Check that the connector type selected for the tools is the one that has been fitted.
Remedy: have the device configured (by a CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M29100-2.XX - Table - 64-pin GVX tool connectors - Device not configured
What this means: The tool module connected to the 64-pin GVX connector on the table is not configured in the PLC network. Checked with the GVX connector selected and enabled, and the tool present.
Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic machine cycle.
Possible causes:
- new or replaced device not yet configured;
- machine configuration not up to date.
How to resolve:
- Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
- Have the device configured (by a CEMAS technician).
Resolution: the issue resolves itself once the device returns to normal operation.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears when the GVX connector is enabled; this option is configured by CEMAS.
Configure device
How to recognise it: the alarm appears as soon as a new tool is connected or after the connector module has been replaced.
Check:
- Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
- Check that the connector type selected for the tools is the one that has been fitted.
Remedy: have the device configured (by a CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M29000-2.XX - Table - Tool connector - 64-pin connector fault
What this means: Summary of alarms for the table’s 64-pin IO-Link connector: this is active when any of them are active.
Effect: alert not displayed in the Alarm Monitor: this stops the machine in the same way as connector alarms, which appear in the Alarm Monitor with their respective codes.
How to resolve:
- Check the Alarm Monitor for the active 64-pin connector alarm and follow the procedure.
Reset: the alarm clears automatically once the device returns to normal operation.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
M29101-2.XX - Table - 64-pin GVX tool connectors - Device not accessible
What this means: The PLC is unable to communicate with the tool module connected to the table’s 64-pin GVX connector. Checked with the GVX connector selected and enabled, and the tools present.
Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle.
Possible causes:
- device switched off or not powered;
- network cable or connector disconnected or damaged;
- tools not connected correctly.
How to resolve:
- Check that the device is powered and that the network LEDs are lit (maintenance technician).
- Check the cable and connectors; under Machine Diagnostics > PLC, on the PLC Hardware tab, the device should show no errors.
- If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).
Reset: the alarm clears automatically once the device returns to normal operation.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears when the GVX connector is enabled; this option is configured by CEMAS.
Turning on the device
How to identify the problem: the tool’s input and output module has its LEDs off and no signals are being received from the tools.
Check:
- Check that the tool’s plug is connected and that the module’s power LEDs are lit.
- Check the status of the connector pins in Tool Change > Tool Change, under the Pin Decoding tab.
Remedy: re-establish the connection or restore power to the module (by a maintenance technician).
Check the message
How to identify the problem: the tool module is powered on but the PLC cannot communicate with it.
Check:
- Check the module’s communication LED.
- Check under Machine Diagnostics > PLC, on the PLC Hardware tab, to see if the device is showing an error, and check the cable and plug contacts.
Remedy: clean or replace damaged contacts and cables (maintenance technician); if the module has been replaced, have its configuration checked (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M29101-2.XX - Table - 64-pin tool connectors - Device not accessible
What this means: The PLC is unable to communicate with the tool’s IO-Link module connected to the table’s 64-pin connector. Checked with the IO-Link connector selected and the tool present.
Effect: Alarm (red line): the machine switches to manual mode (a welding process results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- device switched off or not powered;
- network cable or connector disconnected or damaged;
- tools not connected correctly.
How to resolve:
- Check that the device is powered and that the network LEDs are lit (maintenance technician).
- Check the cable and connectors; under Machine Diagnostics > PLC, on the PLC Hardware tab, the device should show no errors.
- If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).
Reset: the alarm clears automatically when the device returns to normal operation.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears with the IO-Link connector; this option is configured by CEMAS.
Turning on the device
How to identify the problem: the tool’s input and output module has its LEDs off and no signals are being received from the tools.
Check:
- Check that the tool’s plug is connected and that the module’s power LEDs are lit.
- Check the status of the connector pins in Tool Change > Tool Change, under the Pin Decoding tab.
Remedy: re-establish the connection or restore power to the module (by a maintenance technician).
Check the message
How to identify the problem: the tool module is powered on but the PLC cannot communicate with it.
Check:
- Check the module’s communication LED.
- Check under Machine Diagnostics > PLC, on the PLC Hardware tab, to see if the device is showing an error, and check the cable and plug contacts.
Remedy: clean or replace damaged contacts and cables (maintenance technician); if the module has been replaced, have its configuration checked (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M29102-2.XX - Table - 64-pin tool connectors - Hardware fault
What this means: The IO-Link module on the tool connected to the 64-pin connector on the table is sending signals of a hardware fault. Checked with the selected IO-Link connector and the tool present.
Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- faulty device;
- unstable power supply.
How to resolve:
- Switch the machine off and on again and check whether the fault reoccurs.
- If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).
Resolution: the fault clears automatically once the device returns to normal operation.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears with the IO-Link connector; this option is configured by CEMAS.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M29102-2.XX - Table - 64-pin GVX tool connectors - Hardware error device
What this means: The tool module connected to the 64-pin GVX connector on the table is sending signals of a hardware fault. Checked with the GVX connector selected and enabled, and the tools present.
Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic cycle.
Probable causes:
- faulty device;
- unstable power supply.
How to resolve:
- Switch the machine off and on again and check whether the fault reoccurs.
- If it persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).
Resolution: the fault clears automatically once the device returns to normal operation.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears when the GVX connector is enabled; this option is configured by CEMAS.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Presence and position
Alarms from the presence and position sensors for the tools on the head, table and mirror: tools missing when required, not positioned correctly, or present when the machine has not loaded them.
The sensors are configured under Machine Settings > General Settings > Tool Interfaces, in the zone tab, under the Presences and Positions tab.
M30000-2.XX - Table - Presence and position - Tools not present
What this means: The presence sensor on the table does not detect the tools when they should be present: when the clamp mechanism is activated during operation or when the tools are loaded into the PLC. The alarm is logged.
Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- tool not fitted or not seated correctly;
- presence sensor out of calibration, dirty or faulty.
How to resolve:
- Check that the tool is fitted and seated correctly.
- Check the sensor LED and its input under Machine Diagnostics > PLC, Card Monitoring tab; adjust, clean or replace the sensor (maintenance technician).
- Press Reset.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Assembly of tools
How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.
Check:
- Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
- Check that the centerings fit into their sockets and that the interface plate is in the correct position.
- Repeat the loading of the tools from the tool change.
Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M30001-2.XX - Table - Presence and position - Tool not in the correct position
What this means: The tool is present on the table but the position sensor does not confirm the correct position: after the Position error delay set in Machine settings > General settings > Tool interfaces, Table tab, Presences and positions tab (typically 2 seconds, s), or immediately if the clamp is controlled during operation or the tools are loaded. The alarm remains stored.
Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- tool poorly positioned or not centred;
- foreign objects beneath the tooling;
- position sensor out of calibration or faulty.
How to resolve:
- Check that the tool is centred and correctly positioned with no foreign objects present; reposition it if necessary.
- Check the position sensor LED and its input in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace it (by a maintenance technician).
- Press Reset.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Assembly of tools
How to identify the problem: the tools’ clamps, connectors or presence and position sensors are not detecting the correct position.
Check:
- Check that the tools are resting on their mounting, centred and with no foreign objects underneath.
- Check that the centerings fit into their sockets and that the interface plate is in the correct position.
- Repeat the loading of the tools from the tool change.
Remedy: refit the tools correctly; if the alignment pins are damaged, have them repaired (by a maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M30002-2.XX - Table - Presence and position - Tools present
What this means: A sensor on the table detects a tool that the machine has not loaded (or has loaded without parameters) whilst a movement, an actuator or the start of a cycle is being commanded. This is not checked during tool change. The alarm is stored.
Effect: Alarm (red line): the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- previous tool not unloaded or tool data not loaded;
- presence sensor is always active.
How to resolve:
- If the tools are fitted, load their data from Tool Change > Tool Change, Manual tab (Load Tools) or unload them using the unloading procedure.
- If there are no tools, check the sensor and its input in Machine Diagnostics > PLC, Card Monitoring tab (maintenance technician).
- Press Reset.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Dismantle tools
How to recognise this: a sensor detects that a tool is fitted, but the machine has not loaded its data, or the previous tool has remained fitted.
Check:
- Check in Tool Change > Tool Change, under the Manual tab, whether the tool data has been loaded.
- Visually check whether the tool (or the part indicated by the alarm) is fitted.
Remedy: if the correct tool is fitted, load its data (Load Tool); otherwise, unload it using the unloading procedure in Tool Change > Tool Change.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Automatic cycle
Automatic cycle alarms: cycle duration, cavity selection, part contact, fire safety procedure and rejection confirmation. Some stop the cycle and switch the machine back to manual mode, whilst others are simply warnings: each item specifies this.
M31000-0.XX – Automatic cycle – Maximum cycle time
What this means: the duration of the automatic cycle has exceeded the Maximum set in the Cycle time tab under Machine settings > Configuration. With Maximum set to 0, this message appears at every cycle. Not checked during the test cycle.
Effect: Warning (yellow line). Warning only: the cycle continues and the part is not rejected.
Possible causes:
- cycle slowed down by delays (confirmations, actuators or slow presences);
- Maximum set too low or at 0 (Cycle not completed entry).
How to resolve:
- Identify the cycle phase that is slower than usual on the CONTROL PAGE.
- Eliminate the cause of the slowdown (actuators, presences, operator delays).
- If the duration is correct, ask the tool manager to increase the Maximum.
Reset: stored alarm; clear it using Reset in the Alarm Monitor after eliminating the cause.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and checks carried out.
Cycle not completed
How to recognise it: the maximum cycle time warning appears at every cycle, even without any obvious slowdowns.
Check:
- Compare the actual cycle time with the Maximum value on the Cycle Time tab under Tool Settings > Configuration.
- Check that the Maximum is not set to 0.
Remedy: the tool manager sets a Maximum value appropriate to the actual cycle time.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M31001-0.XX – Automatic cycle – Minimum cycle time
What this means: at the end of the cycle, the Minimum time set in the Cycle time tab under Tool settings > Configuration (time counted from start-up) has not elapsed.
Effect: Warning (yellow line). Information only: the cycle ends and the part is not rejected.
Possible causes:
- a cycle phase has been skipped or is shorter than expected;
- Minimum set too high (see Cycle not completed).
How to resolve:
- Check that all cycle phases have been carried out and that the workpiece complies.
- If the duration is correct, ask the tool manager to reduce the Minimum.
Reset: alarm stored; clear by selecting Reset in the Alarm Monitor after rectifying the cause.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.
Cycle not completed
How to recognise it: the minimum cycle time warning appears with good parts and complete cycles.
Check:
- Compare the actual cycle time with the Minimum value on the Cycle Time card under Tool Settings > Configuration.
Remedy: the tool manager reduces the Minimum value based on the actual cycle time.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M31002-0.XX - Automatic cycle - No cavity selected
What this means: With automatic cavity selection, the clamp command has been issued, but neither the LH nor RH workpiece presence sensor detects a workpiece: the machine does not know which cavity to weld.
Effect: Alarm (red line). The automatic cycle is interrupted and the machine switches to manual mode; whilst this mode is active, neither the automatic cycle nor tool change can be initiated.
Probable causes:
- workpiece not inserted or not detected by the presence sensors;
- faulty or misaligned workpiece presence sensor;
- cavity selection set incorrectly (Select cavity option).
How to resolve:
- Insert the part correctly before issuing the clamp command.
- Check that the cavity presence indicator lights up when the part is inserted (Machine Diagnostics > Manual Movements, Presences tab).
- Check Model Selection and Cavity Configuration in Tool Settings > Configuration.
Reset: stored alarm; clear it by selecting Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.
Select cavity
How to identify the problem: the cycle stops at the ‘No cavity selected’ alarm when the clamp is engaged.
Check:
- Check Tool Settings > Configuration under Model Selection and Cavity Configuration.
- With automatic selection, check that the cavity presence indicator lights up when the workpiece is inserted.
Remedy: with manual selection, choose LH+RH, LH or RH before starting; with automatic selection, the workpiece must be inserted before the clamp command is given.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M31003-0.XX – Automatic cycle – Workpiece contact timeout
What this means: during the contact phase between the workpieces, the axes remain stationary for 5 s (fixed value) without detecting contact or reaching the clamp force.
Effect: Alarm (red line). The automatic cycle is interrupted and the machine switches to manual mode; whilst this alarm is active, neither the automatic cycle nor tool change can be initiated.
Probable causes:
- Incorrect Workpiece contact height, often too high (Workpiece contact height configuration setting);
- Missing or incorrectly positioned workpieces;
- Clamp force cannot be achieved.
How to resolve:
- Check the components in the tool.
- Compare the position of the table at contact (Machine Diagnostics > Motor Status) with Workpiece Contact in Tool Settings > Positions.
- Ask the person responsible for the tools to correct the dimension.
Reset: alarm stored; clear it using Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Setting the contact height for workpieces
How to recognise it: the cycle stops during the contact phase with the workpiece contact timeout alarm, even with correct workpieces.
Check:
- Compare the table position at the contact point (Machine Diagnostics > Motor Status) with Workpiece Contact in Equipment Settings > Positions.
Remedy: the equipment manager corrects the height (which is often too high) and runs a test cycle.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M31004-0.XX - Automatic cycle - Cycle timeout
What this means: the automatic cycle has not completed within 180 s (fixed value).
Effect: Alarm (red line). The automatic cycle is interrupted and the machine switches to manual mode; whilst this is active, neither the automatic cycle nor tool change can be initiated.
Probable causes:
- cycle halted whilst awaiting a condition that does not occur (actuator, presence, gate, confirmation);
- movement blocked without a specific alarm.
How to resolve:
- On the CONTROL PAGE, identify the stage at which the cycle has stopped.
- Check the condition being awaited at that stage (actuators, presence sensors, gates) and restore it.
- Check the stages in Equipment Settings > Cycle Settings.
Reset: stored alarm; clear it using Reset in the Alarm Monitor after rectifying the cause; then select Home position (right-hand column) and Automatic cycle to restart.
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), stating the full code, serial number, time of the alarm and the checks carried out.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M31006-0.XX – Automatic cycle – Confirmation of rejection request
What this means: the cycle has ended with a scrap piece and the machine is awaiting confirmation from the operator before opening the gates and releasing the parts.
Effect: Warning (yellow line). The current cycle remains paused; the automatic cycle cannot be restarted until confirmation is given.
How to resolve:
- Confirm the reject using the button with the tick symbol in the SCRAP PIECE(S) box under Machine Status > CONTROL PAGE.
- With Confirm request with login, log in using a user account authorised to Allow tool release.
- Separate the scrap piece from the good parts.
Restore: this is only cleared by confirming the rejection; Reset does not clear it.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Availability: Machine option: appears if Rejection behaviour is set to Confirmation required or Confirmation required with login (Machine settings > General settings > Optionals).
Tool loading cycle
Tool loading alerts (Tool Change > Tool Change page): plug type not selected, tool code not read, rear tool change active.
M32000-0.XX - Tool loading cycle - No connector selected
What this means: When the tool load begins, or when Proceed is selected, the Plug type is not selected in Tool settings > Configuration: the machine does not know which connector to read.
Effect: Alarm (red line). The load does not start. Machine alarm: automatic and tool change functions are blocked.
Probable causes:
- Plug type not set in the tool configuration (Select plug type option).
How to resolve:
- Select the Plug type in Tool settings > Configuration and save the parameters.
- Repeat the loading process via Tool change > Tool change.
Reset: alarm logged; clear by selecting Reset in the Alarm Monitor after rectifying the cause.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), quoting the full code, serial number, time of the alarm and the checks carried out.
Select plug type
How to identify the problem: the tool load does not start and a ‘connector not selected’ alarm is triggered.
Check:
- Check the plug type in Tool Settings > Configuration.
- Check that it matches the plug fitted to the tool.
Solution: select the tool’s plug type, save the parameters and repeat the tool loading process.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M32001-0.XX – Tool loading cycle – Tool code not found
What this means: during the load code check, with the connector plugged in, the tool code is not read within 10 seconds (fixed value).
Effect: Alarm (red line). The load remains stationary. Machine alarm: automatic operation and tool change blocked.
Probable causes:
- plug not inserted or inserted incorrectly;
- incorrect or broken coding pin wiring (see Check wiring);
- code not programmed on the tools.
How to resolve:
- Check that the plug is connected.
- Check the code displayed in the Pin Decoding tab under Tool Change > Tool Change.
- Check the plug wiring (maintenance technician).
Reset: this is cleared upon confirmation of the step or by selecting Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra S.r.l. support (Machine Diagnostics > Support), providing the full code, serial number, time of the alarm and the checks carried out.
Check the wiring
How to identify the problem: the load stops during the code check: the code read is 0 or different from the expected one.
Check:
- Check the code in the Pin Decoding tab under Tool Change > Tool Change.
- Check that the plug is fully inserted.
- Check the wiring of the code pins (maintenance technician).
Remedy: the maintenance technician must rectify the plug wiring; the tool code must be programmed by the tool manager.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M32002-0.XX – Equipment loading cycle – Active rear tool change
What this means: the rear tool change selector is active: the machine is in the process of changing tools at the rear.
Effect: Warning (yellow line). Indication only.
How to resolve:
- Complete the rear tool change.
- Return the selector to the working position.
Resolution: the warning disappears when the selector returns to the working position.
Availability: only on machines with vibration (all 901, 902, 911, 912, 918, 950 and 999 models). Machine option: only with rear tool change (Machine settings > General settings > Components, Rear tool change tab).
Tool unloading cycle
Tool unloading alarms (Tool Change > Tool Change page).
M33000-0.XX - Tool unloading cycle - Unload tool
What this means: The warning (tool unloading) is provided for by the HMI but is not active in current versions of the machine software: under normal conditions, it does not appear.
Effect: Warning not displayed in the Alarm Monitor. No effect on the machine.
How to resolve:
- If the alert appears, note down the full code, the time and the machine’s operating conditions.
- Contact CEMAS Elettra support: they may indicate a version of the machine software different from the one documented.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Archive management
Alerts relating to cycle data logging (records can be viewed under Machine Status > Production Reports).
M34000-0.XX - Archive management - Buffer full
What this means: the queue in which the PLC stores cycle data awaiting archiving (5 archives) is full: the panel is not acquiring the archives. Whilst the queue is full, data from new cycles is discarded.
Effect: Alarm (red line): notification only: does not stop the machine or halt the automatic cycle. Discarded cycles do not appear in the Production Report.
Probable causes:
- Panel archiving has stopped or is running slowly;
- Communication between the panel and the PLC has been interrupted.
How to resolve:
- Check that the panel is switched on and connected (no ‘PLC not connected’ message).
- Restart the operator panel if data logging does not resume.
- Check in Machine Status > Production Report that new cycles are being recorded.
Resolution: the issue resolves itself the first time the panel acquires a log.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M34001-0.XX - Archive management - Acquisition timeout
What this means: the panel did not confirm receipt of a cycle’s data within 2 minutes.
Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle.
Probable causes:
- control panel overloaded or data storage blocked;
- communication between the control panel and the PLC interrupted.
How to resolve:
- Check that the control panel is responding and is connected to the PLC.
- If the alarm recurs, restart the operator panel.
Resolution: the alarm clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Tool columns
Alarms for equipment columns – the columns that hold equipment parts in a stacked configuration for transport and tool changes and which, once the tools are fitted, must be returned to their storage positions. Presence sensors detect columns inserted into the tools, whilst rest sensors detect those that have been stowed.
The sensors are configured in Machine Settings > General Settings > Tool Interfaces, under the ‘Zone’ tab, in the Tooling Columns section.
M35000-2.XX - Table - Tool columns - Columns not fitted
What this means: The columns on the table are not inserted into the tool during the loading and unloading phases when the tool is to be stacked. The alarm remains stored.
Effect: Alarm (red line): the machine switches to manual mode (a welding process results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- columns not inserted or only partially inserted;
- column presence sensor out of calibration or faulty.
How to resolve:
- Insert all columns into the tool sockets, as required by the current step in Tool Change > Tool Change.
- Check the LEDs on the column sensors and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).
- Press Reset and resume the procedure.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Check that the columns have been entered
How to recognise this: during loading or unloading, the process stops whilst columns remain undetected in the tools.
Check:
- Visually check that all columns are fully inserted into their sockets on the tools.
- Check the column sensor LEDs and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab.
Remedy: insert any missing columns; adjust or replace the sensor that is not switching (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M35001-2.XX - Table - Tools columns - Built-in columns
What this means: The columns on the table are still inserted in the tool when they should be removed: whilst the tool is loaded, outside the tool change cycle, or at the end of the loading process. The alarm is stored.
Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- columns not removed at the end of loading;
- column presence sensor remains active.
How to resolve:
- Remove the columns and return them to their storage positions on either side of the fixture.
- Check the LEDs on the column sensors and their inputs under Machine Diagnostics > PLC, Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).
- Press Reset.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Check that the columns have been entered
How to tell: with the tools fitted, the machine sends signals indicating which columns are still in place.
Check:
- Visually check whether any columns have been left in the tool.
- If the columns have been removed, check that the sensors switch off (Machine Diagnostics > PLC, Card Monitoring tab).
Remedy: remove the columns and return them to their storage positions; replace the sensor that is always active (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M35002-2.XX - Table - Tool columns - Columns in the wrong position
What this means: During loading or unloading checks, not all the columns on the table are in the required position: some are engaged and others are not.
Effect: Alarm (red line): this is for information purposes only; it does not stop the machine or halt the automatic cycle.
Probable causes:
- one or more columns have not been moved;
- a column sensor is out of calibration or faulty.
How to resolve:
- Move all columns to the same position: in the transport tool, or to their rest positions with the tool fitted.
- Check the column sensor LEDs and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Check the position of the columns
How to identify this: some columns are inserted and others are not.
Check:
- Visually check the position of each column: all should be in the transport tool, and all should be in their rest positions with the equipment fitted.
- Check that each sensor corresponds to the actual column (Machine Diagnostics > PLC, Card Monitoring tab).
Remedy: move all columns to the same position; adjust any sensor that does not correspond (maintenance technician).
Sensors not working
How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.
Check:
- Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
- Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
- Check the sensor’s connector, cable, mounting and calibration.
Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M35003-2.XX - Table - Tool columns - Non-idle columns
What this means: The columns on the table are not in their resting positions: either when the tools are loaded outside the tool change cycle, or at the end of loading, when they should have been stowed. The alarm is stored.
Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- columns not returned to their rest positions;
- Rest position sensor out of calibration or faulty.
How to resolve:
- Return all columns to their rest positions on either side of the fixture.
- Check the LEDs on the column sensors and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).
- Press Reset.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
M35004-2.XX - Table - Tool columns - Columns at rest
What this means: During unloading, when the columns need to be raised to stack the tools, they are still in their resting positions. The alarm is logged.
Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- columns not retrieved at the Column Insertion stage;
- rest position sensor always active.
How to resolve:
- Remove the columns from their rest positions and insert them into the tools.
- Check the column sensor LEDs and their inputs in Machine Diagnostics > PLC, under the Card Monitoring tab; adjust or replace any sensor that is not switching (maintenance technician).
- Press Reset and resume unloading.
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on machines with vibration (all models 901, 902, 911, 912, 918, 950 and 999).
Voltage monitoring
Alarms relating to the voltage monitoring of the machine’s circuits (up to ten). The status can be viewed under Machine Diagnostics > PLC, on the Card Monitoring tab, in the Voltage Presences section; it can be configured under Machine Settings > General Settings > Components, on the Voltage Presences tab.
M44000-0.XX – Voltage control – Not fitted
What this means: a monitored supply voltage is not present (signal from an input or from a channel on a selective module). The status can be viewed under Machine Diagnostics > PLC, on the Card Monitoring tab, in the Voltage Presences section: grey indicator light = no voltage. In the code, XX is the number of the monitored voltage (from 01 to 10).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. With some configurations, input diagnostics are suspended until the voltage returns.
Probable causes:
- open circuit switch or fuse (Inspect the electric panel);
- selective module channel tripped;
- faulty power supply.
How to resolve:
- Identify the circuit with the grey indicator light.
- Check the circuit’s switches, fuses and selective modules in the control panel (maintenance technician).
- Reset and check that the indicator light turns green.
Reset: once the cause has been rectified, press Reset on the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if voltage monitoring is present (Machine settings > General settings > Components, Voltage presences tab), an option configured by CEMAS.
Inspection of the electric panel
How to identify this: in Machine Diagnostics > PLC, on the Card Monitoring tab, in the Voltage Presences section, the indicator light for a circuit is grey.
Check:
- Identify the circuit that has tripped.
- Check the circuit breakers, fuses and selective module channels for that circuit in the switchboard.
Remedy: eliminate the cause of the trip and reset (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Air interface
Alarms for the air interface, the valve that supplies compressed air to the tools on the head, table or mirror when the tools are present and connected, controlled by a pressure switch and, where fitted, by two safety inputs.
The air interface is configured under Machine Settings > General Settings > Tool Interfaces, in the zone tab, under the Air Valve tab.
M46000-2.XX – Table – Air interface – Pressure switch
What this means: With the table’s air interface open, the pressure switch does not confirm that the pressure is within the Timeout set in Machine Settings > General Settings > Tool Interfaces, Table tab, Air Valve tab (typically 5 seconds, s). The interface is opened whilst the tools are in place, the tool safety devices are engaged, there are no alarms and the pneumatic connector is inserted (if fitted). The alarm is logged.
Effect: Alarm (red line): the interface valve closes; the machine switches to manual mode (a welding operation in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- insufficient compressed air;
- interface valve fails to switch or solenoid coil is not energised;
- pressure switch out of calibration or faulty.
How to resolve:
- Check the supply air pressure (maintenance technician).
- Check that the valve switches (coil LED lit) and that the pressure switch input is activated in Machine Diagnostics > PLC, under the Card Monitoring tab.
- Adjust or replace the pressure switch or the valve (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the air interface is enabled; this option is configured by CEMAS.
Pressure switch adjustment
How to recognise this: air is reaching the tool but the interface pressure switch is not confirming the pressure.
Check:
- Read the pressure using the system pressure gauge.
- Check that the pressure switch is set to 5 bar and that its input is active in Machine Diagnostics > PLC, under the Card Monitoring tab.
Remedy: adjust or replace the pressure switch (maintenance technician).
Controlled electric coil
How to identify the fault: the air supply valve does not open: no pressure reaches the downstream side even when mains air is present.
Check:
- Check that the PLC is controlling the valve (output active in Machine Diagnostics > PLC, Card Monitoring tab).
- Check the LED on the solenoid connector for the controlled valve.
- Check the voltage across the solenoid and the wiring.
Remedy: replace the connector or solenoid; if the solenoid is energised but the valve does not open, replace the valve (by a maintenance technician).
Valve function
How to identify the problem: when the interface is open, air does not reach the tools.
Check:
- Check that the valve coil is receiving a signal (LED lit).
- Check that the valve switches and that there is pressure downstream.
Remedy: replace the faulty valve (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M46001-2.XX - Table - Air interface - Safety inputs not present
What this means: The two safety inputs on the table’s air interface remain out of sync for more than 500 milliseconds (ms). Checked with the safety inputs configured in Machine Settings > General Settings > Tool Interfaces, Table tab, Air Valve tab, and the tool safety devices in place; this setting is saved.
Effect: Alarm (red line): the interface valve closes; the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- one of the two safety sensors is faulty, out of calibration or disconnected;
- unstable pressure.
How to resolve:
- Check the two safety inputs in Machine Diagnostics > PLC, under the Card Monitoring tab: they must change state simultaneously.
- Check the wiring and calibration of the sensor that is lagging behind; replace it if faulty (maintenance technician).
Reset: once the cause has been rectified, press Reset in the Alarm Monitor.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the air interface is enabled; this option is configured by CEMAS.
Selection form
Alarms from the selective modules (up to two), which protect and distribute the 24 V power supply across multiple channels. These are configured under Machine Settings > General Settings > Components, on the Selective Modules tab.
M47000-0.XX – Selective module – Error
What this means: the 24 V selective protection module is signalling a fault: a channel has tripped due to an overload or short circuit, or the diagnostic signal is invalid. In the code, XX is the module number (from 01 to 02).
Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle. The circuit powered by the tripped channel is de-energised.
Probable causes:
- overload or short circuit on a load connected to the channel (Check fault);
- faulty module.
How to resolve:
- Check on the module which channel is faulty (red LED).
- Eliminate the cause of the overload on the connected load (maintenance technician).
- Reset the channel via the module.
Recovery: after resetting the channel, press Reset in the Alarm Monitor; if the fault persists, contact support.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the selective module is present (Machine settings > General settings > Components, Selective modules tab), option configured by CEMAS.
Error check
How to identify it: a channel on the selective module has a red or flashing LED.
Check:
- Check on the module which channel has tripped.
- Check the load supplied by the channel (short circuit or excessive current draw).
Remedy: eliminate the cause and reset the channel in accordance with the module manual (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
I/O interface
Alarms from the IO interface, the welding machine’s network-based input/output module dedicated to the head, table or mirror assembly: module not configured, unreachable or faulty. The status of the modules can be viewed under Machine Diagnostics > PLC, on the PLC Hardware tab.
The interface is configured under Machine Settings > General Settings > Tool Interfaces, on the zone tab, under the Inputs tab.
M48000-2.XX - Table - I/O interface - Device not configured
What this means: The table’s I/O interface is not configured on the PLC network. Only checked when the interface is configured on the network.
Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle.
Probable causes:
- new or replaced device not yet configured;
- machine configuration not up to date.
How to resolve:
- Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
- Have the device configured (by a CEMAS technician).
Resolution: the error clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Configure the I/O interface
How to recognise it: the alarm appears after the module has been replaced or the machine configuration has been changed.
Check:
- Check the status of the IO interface module in Machine Diagnostics > PLC, under the PLC Hardware tab.
Remedy: have the module configured (by a CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M48001-2.XX – Table – I/O interface – Device not accessible
What this means: The PLC is unable to communicate with the table’s I/O interface. Check only when the interface is configured on the network.
Effect: Alarm (red line): indication only: does not stop the machine or halt the automatic cycle.
Probable causes:
- device switched off or not powered;
- network cable or connector disconnected or damaged;
- tools not connected correctly.
How to resolve:
- Check that the device is powered and that the network LEDs are lit (maintenance technician).
- Check the cable and connectors; in Machine Diagnostics > PLC, on the PLC Hardware tab, the device must show no errors.
- If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).
Reset: the alarm clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Connecting the I/O interface
How to identify the problem: the IO interface module shows an error or the LEDs are off.
Check:
- Check that the module is powered (LEDs on).
- Check the network cable and ensure that, under Machine Diagnostics > PLC, on the PLC Hardware tab, the module is shown as error-free.
Remedy: restore the power supply or reconnect the cable (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M48002-2.XX - Table - I/O interface - Hardware fault device
What this means: The table’s I/O interface is signalling a hardware fault. This can only be checked when the interface is configured for network operation.
Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle.
Probable causes:
- faulty device;
- unstable power supply.
How to resolve:
- Switch the machine off and on again, and check whether the fault reoccurs.
- If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).
Resolution: the fault clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Check the hardware
How to identify it: the device sends signals indicating a fault even when the power supply and network are functioning normally.
Check:
- Switch the machine off and on again, and check whether the fault reoccurs.
- Check that the device is correctly installed and undamaged.
Remedy: replace the faulty device (maintenance technician) and have its configuration checked (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Machine valves
Alarms relating to the valve units in the welding machine’s network that control the actuators on the head, table or mirror: unit not configured, unreachable or faulty. The status of the units can be viewed under Machine Diagnostics > PLC, on the PLC Hardware tab.
The valve units are configured in Machine Settings > General Settings > Tool Interfaces, under the zone tab, in the Valves tab.
M51000-2.XX - Table - Machine valves - Device not configured
What this means: The table valve unit is not configured in the PLC network.
Effect: Alarm (red line): the machine switches to manual mode (a weld in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- New or replaced device not yet configured;
- Machine configuration not up to date.
How to resolve:
- Check the status of the device in Machine Diagnostics > PLC, under the PLC Hardware tab.
- Have the device configured (by a CEMAS technician).
Resolution: the error clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Configuring valve units
How to recognise it: the alarm appears after replacing the valve unit or changing the configuration.
Check:
- Check the status of the valve unit in Machine Diagnostics > PLC, under the PLC Hardware tab.
Remedy: have the valve unit configured; configuration must be carried out by a CEMAS technician.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M51001-2.XX - Table - Machine valves - Device not accessible
What this means: The PLC is unable to communicate with the table’s valve unit.
Effect: Alarm (red line): the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- device switched off or not powered;
- mains cable or connector disconnected or damaged;
- tools not connected correctly.
How to resolve:
- Check that the device is powered and that the network LEDs are lit (maintenance technician).
- Check the cable and connectors; in Machine Diagnostics > PLC, on the PLC Hardware tab, the device must show no errors.
- If the alarm persists whilst the connections are intact, have the device checked (CEMAS technician).
Reset: the alarm clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Valve unit start-up
How to identify the problem: the valve unit’s LEDs are off and the tools’ actuators are not moving.
Check:
- Check the power supply to the valve unit (LEDs should be on).
- Check the fuse or circuit breaker supplying power to it.
Remedy: restore power to the unit and check why the protection mechanism tripped (maintenance technician).
Check the message
How to identify the problem: the valve unit is powered on but the PLC cannot communicate with it.
Check:
- Check the unit’s communication LED and the network cable.
- Check under Machine Diagnostics > PLC, on the PLC Hardware tab, that the unit is reporting no errors.
Remedy: re-establish the connection (maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M51002-2.XX - Table - Machine valves - Hardware fault indicator
What this means: The table’s valve unit is signalling a hardware fault.
Effect: Alarm (red line): the machine switches to manual mode (any welding in progress results in a scrap piece); the automatic cycle and tool change remain blocked.
Probable causes:
- faulty device;
- unstable power supply.
How to resolve:
- Switch the machine off and on again and check whether the fault reoccurs.
- If the fault persists, replace the device (maintenance technician) and have its configuration checked (CEMAS technician).
Resolution: the fault clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
General machine information
General machine alerts: hardware safety, checklists, required test cycles and initialisation, movement restrictions excluded, outside dimensions exceeded.
M52000-0.XX – General machine information – Hardware security
What this means: the PLC safety modules (hardware safety) have not given their consent: the safety circuits have not authorised operation.
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- safety module in error or faulty;
- safety circuit open or not reset.
How to resolve:
- Reset emergency stops and safety devices.
- Check in Machine Diagnostics > PLC, under the PLC Hardware tab, that the modules are not in error.
- If the fault persists, contact support (CEMAS technician).
Reset: the message disappears automatically once the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M52001-0.XX – General machine – Incomplete checklist
What this means: the machine checklist has not been completed.
Effect: Info (grey line): does not halt the automatic cycle.
How to resolve:
- In current versions of the control panel, the checklist cannot be completed via the HMI: contact CEMAS Elettra S.r.l. support.
Resolution: it disappears automatically once the condition no longer applies.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M52002-0.XX – General machine information – Test of the required machine cycle
What this means: the machine requires a test cycle, carried out at reduced speed and force (or torque), to verify that the safety devices are functioning correctly. During Putting into Service, this is not required for hydraulic vibration machines and cam-driven IR vibration machines.
Effect: Info (grey line): does not lock: the first cycle initiated is carried out as a test cycle.
How to resolve:
- Set the machine to automatic mode using Automatic Cycle.
- Press the cycle start button: the machine will run the test cycle.
- Check that the cycle completes successfully.
Resolution: the fault clears automatically once the test cycle has completed successfully.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: only on vibration and laser machines.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M52003-0.XX - General machine information - Initialisation confirmation required
What this means: the PLC has detected a new programme or configuration and requires confirmation of initialisation.
Effect: Info (grey line): does not halt the automatic cycle.
How to resolve:
- Do not alter the machine parameters.
- Contact CEMAS Elettra support, who will carry out the confirmation.
Resolution: the message disappears automatically once the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M52004-0.XX - General machine information - Movement constraints bypassed
What this means: motion constraints, which prevent movements that could cause collisions, are disabled using the Bypass motion constraints command in Machine diagnostics > Manual movements (in manual mode).
Effect: Warning (yellow line): the machine does not prevent collisions between moving parts; this is not a fault.
How to resolve:
- Move the machine slowly whilst monitoring it visually.
- Deactivate Bypass movement constraints in Machine diagnostics > Manual movements as soon as you have finished.
Resolution: the alarm clears automatically when the constraints are re-enabled.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M52005-0.XX – General machine specifications – External dimensions
What this means: the external clearance signal is missing: an external device (e.g. a robot) is not confirming that it is outside the machine’s working area. The signal is the Clearance signal under General Signals (Machine Settings > General Settings > Components, General Signals tab).
Effect: Warning (yellow line): indication only: does not stop the machine or halt the automatic cycle. Movements requiring authorisation await the signal.
Probable causes:
- external device within the working area or in alarm mode;
- signal connection interrupted.
How to resolve:
- Check that the external device is outside the work area and not in alarm.
- Check the signal in Machine Diagnostics > PLC, Signals tab.
- Check the signal wiring (maintenance technician).
Resolution: the fault clears automatically once the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the external out-of-limit signal is present (Machine settings > General settings > Components, General signals tab), an option configured by CEMAS.
M52006-0.XX – General machine – Programming error
What this means: PLC programming error. In current versions of the machine software, this message is provided but is not triggered.
Effect: Alarm (red line): none.
If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Planarity
Reports on the planarity check of the table and, on IR and HP machines, of the lower and upper mirrors. The check is carried out by a CEMAS Elettra technician using a dial gauge; the results can be found under Machine Diagnostics > Calibrations and Certifications, in the Planarity tab.
M53000-0.XX – Planarity – Not carried out
What this means: The table planarity check has not been carried out: the measurements have never been confirmed; a value has been modified or is outside the range of ± 0.05 mm; or the machine has been initialised.
Effect: Warning (yellow line). Information only: the machine is operating normally.
Probable causes:
- new or initialised machine;
- measurements modified or out of tolerance (Perform planarity test item).
How to resolve:
- Check the result in Machine Diagnostics > Calibrations and Certifications, Planarity tab, Table tab: Not performed indicates missing or unconfirmed measurements.
- Measure the four corners with the dial gauge, enter the values in Machine settings > General settings > Components, Planarity tab, and confirm (CEMAS technician).
Reset: the warning disappears once the check has been confirmed.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), stating the full code, serial number, time of the alarm and checks carried out.
Carry out planarity tests
How to identify it: under Machine Diagnostics > Calibrations and Certifications, on the Planarity tab, the result is Not performed.
Check:
- Check whether the machine has been initialised or whether the values have been changed.
Remedy: the CEMAS technician measures the planarity using a dial gauge, enters the values in Machine settings > General settings > Components, under the Planarity tab, and confirms the check.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
ID Card Reader
Notifications from the Key ID reader, which the operator uses to identify themselves on the machine. This is configured under Machine settings > General settings > Components, on the Key ID reader tab.
M54000-0.XX - ID Key Reader - Device not configured
What this means: The ID key reader is not configured on the PLC network.
Effect: Warning (yellow line): information only: does not stop the machine or halt the automatic cycle. Identification using the key may not work.
Probable causes:
- Reader not configured or incorrectly configured (Configure ID key reader).
How to resolve:
- Have the reader configured (by a CEMAS technician).
Resolution: the message disappears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.
Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), an option configured by CEMAS.
Configure the ID key reader
How to identify the problem: the reader is fitted and powered, but the machine reports it as unconfigured and the key is not being read.
Check:
- Check that the reader fitted is the model specified in the wiring diagram.
- Check that it has not been replaced recently.
Remedy: the reader must be configured by CEMAS Elettra personnel: contact support (CEMAS technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M54001-0.XX – ID Key Reader – Device not accessible
What this means: The PLC is unable to access the ID key reader.
Effect: Warning (yellow line): information only: does not stop the machine or halt the automatic cycle. Key identification may not work.
Probable causes:
- reader switched off or not powered (Switch on ID key reader);
- communication interrupted (Check communication).
How to resolve:
- Check that the reader is switched on (LEDs lit).
- Check the network and power cables (maintenance technician).
Resolution: the fault clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), an option configured by CEMAS.
ID Key Reader Activation
How to recognise this: the LEDs on the ID card reader are off.
Check:
- Check the reader’s power supply and its connector.
Remedy: restore the power supply; if the reader remains off, replace it (by a maintenance technician).
Check the message
How to identify the problem: the reader is switched on but is not communicating with the machine.
Troubleshooting:
- Check the reader’s communication LEDs.
- Check the network cable or the connection to the Smart accessory.
Remedy: Reconnect or replace the cable (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M54002-0.XX – ID Key Reader – Hardware error
What this means: The ID key reader is reporting a hardware fault.
Effect: Warning (yellow line): this is for information only; it does not stop the machine or halt the automatic cycle. Key identification may not work.
Probable causes:
- Faulty reader.
How to resolve:
- Switch the machine off and on again and check whether the warning disappears.
- If it persists, replace the reader (by a maintenance technician).
Reset: the warning disappears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), an option configured by CEMAS.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M54003-0.XX – ID Key Reader – ID Error
What this means: the code read from the key is invalid.
Effect: Warning (yellow line): information only: does not stop the machine or interrupt the automatic cycle. Key identification may not work. The key remains stored.
Possible causes:
- Key is not authorised, damaged or inserted incorrectly.
How to resolve:
- Remove and reinsert the key.
- Try another authorised key.
- If no key is recognised, check the reader (maintenance technician).
Reset: once the cause has been rectified, select Reset in the Alarm Monitor.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), option configured by CEMAS.
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M54004-0.XX – ID Key Reader – Communication error
What this means: The ID key reader is not communicating with the welding machine’s PLC.
Effect: Warning (yellow line): this is for information purposes only; it does not stop the machine or halt the automatic cycle. Identification using the key may not work.
Probable causes:
- Network or power cable disconnected (ID key reader connection).
How to resolve:
- Check the power supply and the reader’s LED.
- Check the network cable and connectors (by a maintenance technician).
Resolution: the message disappears automatically once the issue has been resolved.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), an option configured by CEMAS.
ID Key Reader Connection
How to recognise this: the reader is not communicating with the machine, often following work carried out on the control panel or the wiring.
Check:
- Check the reader’s power cable.
- Check the network cable and connectors.
Remedy: reconnect or replace any damaged cables (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
M54005-0.XX – ID Key Reader – Offline
What this means: the ID key reader, connected via the Smart accessory, is disconnected.
Effect: Warning (yellow line): this is for information only; it does not stop the machine or halt the automatic cycle. Key identification may not work.
Possible causes:
- cable disconnected (Check connection);
- communication with the Smart accessory interrupted (Check communication).
How to resolve:
- Check the cable between the reader and the Smart accessory.
- Check that the Smart accessory is switched on and communicating.
Resolution: the fault clears automatically once the condition no longer exists.
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the Key ID reader is present (Machine settings > General settings > Components, Key ID reader tab), an option configured by CEMAS.
Check the connection
How to recognise this: the reader, connected via the Smart accessory, appears to be disconnected and the key is not read.
Check:
- Check that the cable between the reader and the Smart accessory is connected and undamaged.
- Check that the Smart accessory is switched on.
Remedy: reconnect or replace the cable (by a maintenance technician).
Check the message
How to identify the problem: the reader is switched on but is not communicating with the machine.
Troubleshooting:
- Check the reader’s communication LEDs.
- Check the network cable or the connection to the Smart accessory.
Remedy: Reconnect or replace the cable (by a maintenance technician).
Further information
How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.
Check:
- Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
- Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
- Note down the checks already carried out and their results.
Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.
Virtual master axis
Alarms for the master virtual axis, the reference axis that synchronises the table’s movement with the vertical and horizontal cams of the IR mirror during preheating. The cam profiles are recalculated and checked whenever the cam parameters or mirror type change; the axis is controlled manually via Machine Diagnostics > Manual Movements, Machine tab > Axes, Synchro tab.
Availability: only on IR cam-driven vibration machines (911MK2-IR, 918MK2-IR), with tools fitted with a cam-driven mirror.
Tool trolley
Notifications regarding the trolley, the trolley used for tool changes. This is configured under Machine settings > General settings > Components, on the Trolley tab.
M59000-0.XX – Tool trolley – In stock
What this means: the presence sensor detects the trolley inserted into the machine in the correct position. The message appears at any stage, not just during tool change.
Effect: Warning (yellow line): the trolley is preventing the table from rising.
Possible causes:
- trolley left in place after a tool change.
How to resolve:
- If the tool change is complete, remove the trolley.
- If the trolley is removed but the warning persists, check the presence sensor (maintenance technician).
Reset: the warning disappears automatically once the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the trolley is present (Machine settings > General settings > Components, Trolley tab), option configured by CEMAS.
M59001-0.XX – Tool trolley – Not available
What this means: Trolley not inserted into the machine. In current versions of the machine software, this warning is provided for but is not triggered.
Effect: Warning (yellow line): none.
If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the trolley is present (Machine settings > General settings > Components, Trolley tab), option configured by CEMAS.
M59002-0.XX - Tool trolley - Trolley not in the correct position
The position sensor signals that the trolley is not correctly positioned.
Optional connectors
Alarms for optional connectors (up to five), additional connections between the machine and the tool. These are configured under Machine Settings > General Settings > Components, on the Optional Connectors tab; the tool specifies which ones it uses under Tool Settings > Configuration, on the Optional Connectors card.
M60000-0.XX - Optional connectors - Not fitted
What this means: with the tool installed, the optional connector XX is specified by the tool (Tool Settings > Configuration, Optional Connectors tab) but its presence sensor does not detect it. This is a continuous check. In the code, XX is the number of the optional connector (from 01 to 05).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.
Probable causes:
- connector not connected or not fully inserted;
- faulty connector presence sensor;
- connector incorrectly specified in the tool parameters.
How to resolve:
- Connect the optional connector and insert it fully.
- Check under Tools Settings > Configuration, on the Optional Connectors tab, that the tool is actually supposed to use it.
- If it is connected but not detected, check the presence sensor (maintenance technician).
Reset: the message disappears automatically when the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: this appears if the optional connector is present (Machine settings > General settings > Components, Optional connectors tab), an option configured by CEMAS.
M60001-0.XX - Optional connectors - Present
What this means: when no tool is inserted, the sensor for the optional connector XX detects that it is connected. The tool parameters are irrelevant; when a tool is inserted, an unexpected connector does not trigger any alarms. In the code, XX is the number of the optional connector (from 01 to 05).
Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. It also blocks entry into the tool change sequence.
Probable causes:
- connector left connected after the tool has been unloaded;
- presence sensor always active.
How to resolve:
- Disconnect the optional connector and stow it away.
- If it is disconnected but the alarm persists, check the presence sensor (maintenance technician).
Reset: the fault clears automatically once the condition no longer exists.
Safety:
Availability: machine option: appears if the optional connector is present (Machine settings > General settings > Components, Optional connectors tab), option configured by CEMAS.
M60002-0.XX – Optional connectors – Incorrect position
What this means: optional connectors are either not fully connected or are in the wrong position. In current versions of the machine software, this warning is provided but is not triggered. In the code, XX is the number of the optional connector (from 01 to 05).
Effect: Alarm (red line): none.
If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the optional connector is present (Machine settings > General settings > Components, Optional connectors tab), option configured by CEMAS.
Electric panel doors
Alarms for the electric panel doors (up to four). These are configured under Machine settings > General settings > Components, on the Electric panel doors tab.
M61000-0.XX - Electric panel doors - Electric panel door not closed
What this means: the electric panel door sensor signals that the door is open. In the code, XX is the electric panel door number (from 01 to 04).
Effect: Alarm (red line): warning only: does not stop the machine or halt the automatic cycle. With the door open, the control cabinet is not cooled properly and the powered components are not protected.
Probable causes:
- control cabinet door open or not fully closed;
- door sensor faulty or misaligned.
How to resolve:
- Close the electric panel door.
- If it is closed and the fault indication persists, check the sensor (maintenance technician).
Reset: the warning disappears automatically once the condition no longer exists.
Safety:
If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.
Availability: machine option: appears if the control of the electric panel doors is enabled (Machine settings > General settings > Components, Electric panel doors tab), an option configured by CEMAS.
Tool Conveyor
Alarms for the tool roller conveyor, the roller system that transports the tool onto the table during tool change: slide, clamps, rollers and tool presence. The roller conveyor is configured in Machine Settings > General Settings > Components, under the Tool Roller Conveyor tab.
Availability: only on HP laser and hot plate machines. Machine option: appears if the Tool Conveyor is present (Machine Settings > General Settings > Components, Tool Conveyor tab, Present).