Skip to content

Tool settings

The Equipment Settings unit contains the pages for configuring the fitted equipment: axis dimensions, actuators, presences, gaps, welding cycle and welding parameters. The settings are saved along with the equipment configuration.

Pages in the unit:

  • Configuration, Actuators and Presences, Positions, Cycle Settings, Welding Parameters;
  • Infrared Parameters: only on machines with infrared heating and a mirror tool;
  • Synoptic display and Smart tools: only when smart tools are loaded;
  • Hot plate: only on HP machines with hot plate tools.

These pages are only available when a tool is loaded, or when putting into service is active.

Tapping the unit on the Home page opens a pop-up showing, on the left, the unit’s icon, name and description, and, on the right, the list of pages; these same pages are also in the side menu.

Appearance: a green square icon with a dotted outline of a tool.

Position: on the Home page, in the first unit of the bottom row.

Configuration

The Configuration page contains the general settings for the loaded tools. The settings are saved with the tool configuration and reused every time the tools are loaded onto the machine.

The page consists of a grid of cards; which cards appear depends on the technology, the machine’s options and the advanced view:

  • always: Configuration, Cycle time and Piece taking (or Sliding table on machines that have one);
  • depending on the machine’s options: Plug type for the table, head and platen, ID association, gates, Optional connectors, Guards, Platen cleaning;
  • with multi-cavity tools: Model selection and, on the right, Cavity configuration;
  • in the advanced view: Alternative automatic cycle and User feedback.

Changes take effect immediately, even before saving. To reuse them in subsequent loadings, they must be saved in the tool configuration using the floppy disk button at the top. As long as there are unsaved changes, the machine signals a tool alarm and does not allow the automatic cycle, except when Putting into Service or Configuration Mode is active; after saving a change, the machine requires a test cycle until a cycle completes successfully.

Configuration

Configuration, lower section

Configuration, advanced view

Position: Equipment Settings > Configuration menu.

Configuration

The Configuration tab contains general information about the tools:

  • Height of tools in column configuration: total height of the assembled tools, in millimetres (mm);
  • Loading onto the head and Unloading from the head: switches indicating whether the workpiece is loaded onto the head and unloaded from the head; Loading onto the head cannot be changed when using the Simple piece taking gripper. The cycle movements remain unchanged: these are only used to display the correct images during the cycle stages on the CONTROL PAGE;
  • Total tool weight and Lower tool weight: weights in kilograms (kg), available only in the advanced view. These are for information purposes only: the machine does not use them during the cycle, neither to compensate for force nor to control the load.

Load on the head, Unload from the head and the weights are visible only to users with the machine configurator profile.

On laser machines, the fields change: see the related entries. The Alternative automatic cycle card displays the same help text: see the related entry.

Appearance: dark grey card with the title in white capital letters in the top left-hand corner and white fields with a green border followed by the unit.

Configuration

Position: Equipment Settings > Configuration page, first card at the top left.

Height of column-mounted tools

The Height of stacked tools field refers to the total height of the tools mounted on the machine, with the top and bottom sections stacked on top of one another, in millimetres (mm), to one decimal place.

Availability: on all machines except lasers, which have Tool height instead.

Configuration

Appearance: white field with a green border followed by mm.

Position: Machine Settings > Configuration page, Configuration tab, first row.

Load on the head

The Load onto head switch indicates that the top workpiece is loaded onto the head (on the upper fixture) rather than onto the table. It does not alter the machine cycle movements: it simply serves to display the correct images during the cycle stages on the Machine status > CONTROL PAGE.

It cannot be modified with the Simple piece taking gripper; with the Simple without slide piece taking gripper, the machine always considers it deactivated.

Availability: Visible only to users with the machine configurator profile.

Appearance: slide switch, green when active, grey when not editable.

Position: Tooling Settings > Configuration page, Configuration tab, below the tool height.

I’ve got it out of my head

The Unload from head switch indicates that, at the end of the cycle, the welded part remains on the head and is unloaded from there. It does not alter the cycle movements: it simply serves to display the correct images for the cycle stages on the Machine Status > CONTROL PAGE.

Availability: Visible only to users with the machine configurator profile.

Appearance: slide switch, green when active.

Position: Equipment Settings > Configuration page, Configuration tab, under Load on Head.

Total weight of tools

The Total tool weight field is the weight of the complete tool, comprising the upper and lower sections, in kilograms (kg), without decimals. This is for information purposes only: the machine does not use this data during the cycle, either to compensate for force or to control the load.

Availability: visible only in the advanced view and to users with the machine configurator profile.

Appearance: white field with a green border followed by kg.

Position: Equipment Settings > Configuration page, Configuration card, penultimate row.

Lower tool weight

The Lower tool weight field is the weight of the lower part of the tool alone, mounted on the table, in kilograms (kg), without decimals. This is for information purposes only: the machine does not use this data during the cycle.

Availability: visible only in the advanced view and to users with the machine configurator profile.

Appearance: white field with a green border followed by kg.

Position: Equipment Settings > Configuration page, Configuration card, last row.

Automatic alternating cycle

The Alternative Automatic Cycle card allows you to have multiple automatic cycles on the same tool and to choose which one to run:

  • Enable activates the function;
  • the drop-down menu allows you to select the cycle to run from among those enabled: Operator (the main cycle) and the alternative cycles;
  • the button on the right opens the Alternative Automatic Cycle pop-up, where each cycle has a tick box to enable it and a field for the name.

The menu and button can only be used when the function is enabled. The stages of each enabled cycle are set in a dedicated tab on the Tool Settings > Cycle Settings page.

The selected cycle takes effect from the next start of the automatic cycle: whilst the machine is in automatic mode, the selection has no effect until you return to manual mode. If the machine option or the function on the tool is disabled, or the selected cycle is not enabled, the machine runs the main cycle. The selected cycle determines the stages performed and the external input commands used by actuators and vacuums.

The card appears in the advanced view if the machine has the alternative cycles option, or whenever the function is enabled on the tools.

Appearance: a dark grey card with the title in white capital letters in the top left-hand corner, the Enable box, a drop-down menu and a round green button with a black pencil icon; the menu and button are grey or dark green when they are not available.

Alternative automatic cycle

Position: Equipment Settings > Configuration page, in the advanced view to the right of the Configuration card.

Automatic alternating cycle

The Alternative Automatic Cycle pop-up lists the tools’ automatic cycles, up to four in total: the first is the main cycle (Operator), and the others are the alternative cycles. For each cycle:

  • the box on the left enables it: enabled cycles appear in the card’s drop-down menu and have a tab on the Tool Settings > Cycle Settings page;
  • the field on the right contains the cycle name, displayed in the menu and on the tab; it can only be edited whilst the cycle is enabled. If no name is provided, the cycle is referred to by its default name.

This is opened using the pencil button on the Alternative Automatic Cycle card, which can only be used if the function is enabled on the card (Enable). Close the pop-up using the down arrow.

Availability: machine option configured by CEMAS: the card appears in the advanced view with the Alternative Automatic Cycle option; if the function is already enabled on the tools, the card always appears.

Appearance: full-screen pop-up with a list of rows, each containing a square box and a white text field (grey when the cycle is not enabled); the button that opens it is a green circle with a black pencil icon.

Alternative Automatic Cycle

Position: Equipment Settings > Configuration page, Alternative Automatic Cycle card, button to the right of the drop-down menu.

User feedback

The User Feedback tab determines whether, at the end of the cycle, the CONTROL PAGE prompts the operator to inspect the workpiece and indicate whether it is good or a reject, selecting the type of reject where applicable. The drop-down menu has three options:

  • Disabled: no prompt;
  • Rejects only: prompt only for cycles that the machine classifies as rejects;
  • Always: prompt for every cycle.

The button on the right, which can be used when feedback is enabled, opens the Reject Type pop-up, displaying the list of reject types available to the operator for this tool.

With this option enabled, after the part has been removed, the cycle waits for the operator to confirm the part as good or mark it as a reject. The operator’s judgement overrides that of the machine in the production history.

The card appears in the advanced view or whenever feedback is active.

Appearance: a dark grey card with the title in white capital letters in the top left-hand corner, a drop-down menu and a round green button with a black pencil icon, which turns dark green when it is unavailable.

User feedback

Position: Equipment Settings > Configuration page, in the advanced view, in the first row of cards, on the right.

Type of waste

The Scrap Type pop-up defines the scrap types suggested to the operator for this tool when, at the end of the cycle, the CONTROL PAGE asks for a judgement on the workpiece (User Feedback card). The types are saved for the tool (serial number) in the machine’s database, not in the PLC parameters.

On the left is the Scrap list; on the right, after selecting or adding a type, are the Scrap and Description fields, the Allow description and Description required checkboxes, and the buttons to save or close.

It opens via the pencil button on the User Feedback tab, which can only be used when feedback is active (Only with reject or Always).

Availability: the User Feedback tab appears in the advanced view, or whenever feedback is active.

Appearance: full-screen pop-up; the button that opens it is a green circle with a black pencil icon, dark green when it cannot be used.

Position: Equipment Settings > Configuration page, User Feedback card, button to the right of the drop-down menu.

Waste

The Scrap list shows the types of scrap configured for the tool, along with their names. Tap a row to edit it in the panel that opens on the right; the − button to the left of the row deletes the type immediately; the + button at the bottom of the list adds a new one, indicated by the word New at the top of the panel.

Appearance: rows with a round green button bearing the − symbol and the name; the selected row is lighter in colour; at the bottom, a round green button bearing the + symbol.

Position: Waste type pop-up, left-hand half.

Discard

The Scrap field is the short name of the scrap type, up to 20 characters long, displayed to the operator in the list of scrap types when they select a scrap piece and in the production history.

Appearance: white field with a green border, with the title above it.

Position: Scrap type pop-up, right-hand panel, first field.

Description

The Description field provides an explanation of the type of reject, limited to a maximum of 50 characters, which helps the operator select the correct type.

Appearance: a white field with a green border, with the title above it.

Position: Type of waste pop-up, right-hand panel, below Waste.

Show description

The Allow description tick box enables the operator, when selecting this type of rejection, to enter a free-form description of the defect. Deselecting this box also removes Description required.

Appearance: a square box with a tick when active.

Position: Rejection type pop-up, right-hand panel, below Description.

Description of the request

The Request description box makes it compulsory to provide a free-form description of the defect when the operator selects this type of rejection. It can only be used when Allow description is enabled.

Appearance: a square box with a tick when active, grey when unavailable.

Position: Rejection type pop-up, right-hand panel, last box.

Save

The button with the floppy disc saves the added or modified waste type and closes the panel; the button with the X next to it closes the panel without saving. Any unsaved changes to the fields will be lost.

Appearance: two round green buttons with black icons of a floppy disk and an X.

Position: Waste Type pop-up, at the bottom of the right-hand panel.

Cycle time

The Cycle Time tab defines the duration limits for the automatic cycle, in seconds (s):

  • Minimum and Maximum: if the cycle duration falls outside these limits, an alarm is triggered; for the maximum limit, as soon as the time is exceeded; for the minimum limit, at the end of the cycle. The alarm is merely a warning: the cycle does not stop, the part is not rejected and the alarm is cleared upon reset. During the test cycle required following a modification, the maximum limit is not checked;
  • Ideal: reference cycle time, visible only in the advanced view and to authenticated users. It is sent only to the factory data collection system (IoT): the machine does not use it for statistics.

Regardless of these limits, the machine has a fixed time limit of 180 s; if this is exceeded, the cycle is interrupted and an alarm is triggered.

Appearance: dark grey card with the title in white capital letters in the top left-hand corner and white fields with a green border followed by s.

Cycle time

Position: Equipment Settings > Configuration page, second tab in the first row (in advanced view, first tab in the second row).

Minimum

The Minimum field on the Cycle Time card is the expected minimum duration of the automatic cycle, in seconds (s), with one decimal place. If, at the end of the cycle, the duration is shorter than this, an alarm is triggered; this is merely a signal: the part is not rejected and the alarm is cleared upon reset. A cycle that is too short may indicate, for example, a skipped stage or missing parts.

Cycle time

Appearance: white field with a green border followed by s.

Position: Machine Settings > Configuration page, Cycle Time tab, first line.

Massimo

The Maximum field on the Cycle Time tab is the maximum duration of the automatic cycle, in seconds (s), with one decimal place. As soon as this time is exceeded, an alarm is triggered; this is merely a signal: the cycle does not stop and the part is not rejected. During the test cycle required following a modification, the maximum value is not checked. Regardless of this value, the machine will anyhow stop the cycle after 180 s.

Appearance: white field with a green border followed by s.

Position: Machine Settings > Configuration page, Cycle Time tab, second row.

Ideal

The Ideal field on the Cycle Time card is the tool’s reference cycle time, in seconds (s), with one decimal place. It is sent only to the factory data collection system (IoT), which uses it to compare the actual time with the expected time: the machine does not use it during the cycle or for its own statistics.

Availability: visible only in the advanced view and to authenticated users.

Appearance: white field with a green border followed by s.

Position: Equipment Settings > Configuration page, Cycle Time card, last row.

Piece taking

The Piece Taking tab determines how the parts to be welded are loaded:

  • Disabled: the operator loads the parts onto the fixtures by hand;
  • Simple: the welding machine automatically performs the operations to pick up the upper part from the upper fixture, without operator intervention.

The other modes and additional parameters depend on the machine’s technology: see the related entries. The dimensions used by the piece taking socket are set on the Equipment Settings > Positions page.

On machines with a sliding table, the Sliding Table tab is used instead of this tab.

Availability: machine option: appears if the Sliding Table is not present (Machine Settings > General Settings > Components, Sliding Table).

Appearance: dark grey tab with the title in white capital letters in the top left-hand corner and a list of round white selection buttons with green borders; the selected one has a black dot in the centre.

Piece taking device

Position: Equipment Settings > Configuration page, third card in the first row (in advanced view, in the centre of the second row).

Piece taking – Vibration

On machines with no infrared heating, there is also Simple with Centering, the simple piece taking method using centerings. The gripping mechanism skips the slide movements and moves the table to the piece taking height, which acts as a stop for the centering process, then moves out of the way. The centerings do not have a dedicated control: they move in the steps for which they are programmed within the cycle phases (usually the piece taking step) and the cycle waits for them to reach their position.

Plug type

The Plug Type cards determine the type of plug used to connect the tool to the welding machine; the tool’s signals, such as those for presence sensors and actuators, pass through this plug. There is one card for each interface:

  • Table Plug Type: always, if the machine has at least one connector on the table;
  • Head connector type: on IR, HP and laser machines;
  • Mirror connector type: on machines with a mirror, where the tool is fitted with a mirror;
  • Right-hand mirror connector type: on machines with two mirrors (912-IR).

The options are the connectors enabled on the machine: CEMAS 24, CEMAS 32, Custom, GVX, IoLink (with the number of nodes) and, except for the table, None. The Pneumatic box indicates that the tool also uses the pneumatic connector; when IoLink is selected for the table, the Smart tool box appears.

The selected connectors determine the pins available on the Tool settings > Actuators and presences page.

Availability: Head plug type only on IR, HP and laser machines; Mirror plug type only on IR, HP, 911MK2-IR, 912-IR and 918MK2-IR machines; Right-hand mirror plug type only on the 912-IR. Machine option: each card appears if at least one connector is enabled for that section (Machine Settings > General Settings > Tool Interfaces, Connectors). Tool option: Mirror plug type appears with a tool that has a mirror, i.e. where the Tool type is other than Without mirror (Tool settings > Configuration, Tool type tab).

Appearance: dark grey card with the title in white capital letters in the top left-hand corner, round selection buttons for the connector and the square Pneumatic box.

Plug type

Position: Equipment Settings > Configuration page, second row of cards.

CEMAS 24

Selecting Cemas 24 indicates that the tool is connected via the 24-pin CEMAS connector, with digital inputs and outputs. The Equipment Settings > Actuators and Presences page lists the pins on this connector.

Availability: machine option configured by CEMAS: appears if the Cemas 24 connector is enabled for that part.

Appearance: round selection button labelled Cemas 24.

Position: Equipment Settings > Configuration page, Plug Type tab (table, head, mirror).

CEMAS 32

Selecting Cemas 32 indicates that the tool is connected via the 32-pin CEMAS connector, with digital inputs and outputs. The Equipment Settings > Actuators and Presence page lists the pins on this connector.

Availability: machine option configured by CEMAS: appears if the Cemas 32 connector is enabled for that part.

Appearance: round selection button labelled Cemas 32.

Position: Equipment Settings > Configuration page, Plug Type tab (table, head, mirror).

Customised

The Custom option indicates that the tools are connected via a non-standard plug, configured for the machine.

Availability: machine option configured by CEMAS: this appears if the Custom connector is enabled for that part.

Appearance: round selection button labelled Custom.

Position: Equipment Settings > Configuration page, Plug Type tab (table, head, mirror).

GVX

The GVX selection indicates that the tool is connected via the 64-pin GVX connector, used for non-Cemas tools with CANopen communication.

Availability: machine option configured by CEMAS: this appears if the GVX connector is enabled for that part.

Appearance: round selection button labelled GVX.

Position: Equipment Settings > Configuration page, Connector Type tab (table, head, mirror).

Selecting IoLink indicates that the tools communicate with the machine via IO-Link modules. The field next to it, followed by nodes, shows the number of IO-Link modules (nodes) present on the tools. When IoLink is selected, the Smart Tools box also appears on the table.

Availability: machine option configured by CEMAS: appears if the IoLink connector is enabled for that part.

Appearance: round selection button labelled IoLink and, to the right, a white field with a green border followed by nodes.

Position: Equipment Settings > Configuration page, Plug Type tab (table, head, mirror).

Pneumatics

The Pneumatic tick box indicates that the tool also uses the pneumatic connector on that part of the machine (table, head or mirror) for the compressed air supply to the actuators.

Appearance: a square tick box which is ticked when active.

Position: Equipment Settings > Configuration page, Connector Type tab (table, head, mirror), below the connector options.

Smart tools

The Smart Tool box indicates that the tool connected via IoLink is a smart tool, which exchanges signals with the machine. When the smart tool is loaded, the Synoptic and Smart Tool pages appear, and on the Tool Settings > Actuators and Presences page, commands can utilise the smart tool’s signals.

Availability: machine option configured by CEMAS: appears if the IoLink connector is enabled on the table. Tool option: appears when the IoLink plug is present on the table (Tool Settings > Configuration, Table Plug Type tab).

Appearance: a square box with a tick when active.

Position: Tool Settings > Configuration page, Table Connector Type tab, last row.

Model selection

The Model Selection tab appears when using a multi-cavity mould. The Automatic box enables automatic model selection: the welding machine recognises, via the presences, whether parts from all cavities or only those on one side are to be welded during the cycle. The sensors to be used are specified on the Mould Settings > Actuators and Sensors page, under the Sensors tab, in the Model Selection unit.

When automatic selection is disabled, the side to be used is selected manually.

Availability: tool option: appears with a multi-cavity tool (Tool Settings > Configuration, Cavity Configuration tab).

Appearance: a dark grey tab with the title in white capital letters in the top left-hand corner and the Automatic box, which is ticked when enabled.

Model selection

Position: Equipment Settings > Configuration page, after the Plug Type tabs.

Front gate

The Front gate tab appears on machines fitted with a front gate and configures its use with this tool:

  • Bypass: excludes the gate from the cycle, meaning it is neither opened nor closed and the machine starts with the gate in its current position; the emergency stop and doors remain active, and operator safety is ensured by the safety barrier;
  • Move with the table: only if the gate is designed to move with the press, and never with the two-hand control; the table moves whilst the gate closes and, on machines with vibration, the gate begins to open as soon as the table returns to the loading position;
  • Open home position: can only be used with Bypass active; this determines where the gate goes when it is returned to its home position in manual mode or during tool change: open when the box is ticked, closed when the box is unticked. The automatic cycle does not move it.

The Rear Gate card, on machines equipped with one, has the same settings for the rear gate.

Appearance: dark grey card with the title in white capital letters in the top left-hand corner and square tick boxes; Open home position is grey when unavailable.

Position: Tool Settings > Configuration page, at the bottom of the card grid.

Front gate and rear gate

The Front Gate and Rear Gate tabs appear on machines fitted with the corresponding gate and configure its use with this tool:

  • Bypass: excludes the gate from the cycle, meaning it is neither opened nor closed and the machine starts with the gate in its current position; the emergency stop and doors remain active, and operator safety is ensured by the safety barrier;
  • Move with the table: only if the gate is designed to move with the press, and never with the two-hand control; the table moves whilst the gate closes and, on vibration machines, the gate begins to open as soon as the table returns to the loading position (if there is a scrap piece requiring an action, the gate remains closed). On IR and HP machines, simultaneous movement occurs only whilst waiting for the gate to close;
  • Open home position: usable only with Bypass active; this determines where the gate goes when returned to its home position in manual mode or during tool change: open when the box is active, closed when the box is deactivated. The automatic cycle does not move it.

Appearance: dark grey card with the title in white capital letters in the top left-hand corner and square boxes; Open home position is grey when unavailable.

Front gate

Location: Tool Settings > Configuration page, at the bottom of the card grid.

Optional connectors

The Optional Connectors tab appears on machines with at least one optional connector and features a tick box for each one, labelled with the connector’s name: ticking the box enables the connector for that tool. For an enabled connector, the machine checks for the presence of the plug: the tool load waits until all enabled connectors are connected, and the unload waits until they are all disconnected, triggering an alarm if this condition is not met. The connector can only be enabled if the machine has the corresponding presence sensor.

Appearance: a dark grey card with the title in white capital letters in the top-left corner and a square box for each connector.

Position: Equipment Settings > Configuration page, at the bottom of the card grid.

Cavity configuration

The Cavity Configuration tab specifies whether the tool has a single cavity or two cavities. The cavity determines the set of welding parameters used in the automatic cycle; with two cavities, the Model Selection tab appears, which determines whether the working cavity is selected automatically based on the presence of workpieces or manually.

This tab does not appear on single-side configured machines. Editing it requires write permissions.

Availability: machine option: appears if Single-cavity machine is not active (Machine settings > General settings > Optionals).

Appearance: a column with the title in capital letters and two diagrams of the tool (one cavity, two cavities), each with its own selection button.

Position: Tool Settings > Configuration page, column to the right of the card grid.

Actuators and Presences

The ACTUATORS AND PRESENCES page allows you to view and control the parameters of the objects on the tool, i.e. presences, actuators and vacuums. In ADVANCED CONFIGURATION, you can view and control the input and output commands of the tool.

Presences

The PRESENCE card allows you to view and control the parameters of the objects on the tool that control the parts to be welded. The objects performing the control can be:

  • sensors;
  • photocells;
  • mechanical microswitches;
  • fibre optics;
  • more.

Attendance list

The left-hand side of the Attendance tab lists the configured presences. Each row shows the presence number, the name and, in the Status column, an indicator:

  • green: active presence;
  • grey: inactive presence;
  • red: presence in alarm mode.

Tap a row to view its parameters on the right. The − button to the left of the row deletes the presence; the + button at the bottom of the list adds a presence by selecting from the available numbers, until the maximum number allowed by the machine is reached. If the machine does not support presences, No presence available appears.

Appearance: rows with a round green button displaying the − symbol, the number in a circle, the name in white and the round indicator light; the selected row is lighter in colour. At the bottom, a round green button displaying the + symbol.

List of presences

Indicator statuses

Position: Equipment settings > Actuators and presences page, Presences tab, left-hand side.

Presence settings

The right-hand side of the Presences tab displays the parameters for the selected presence, listed in rows: name (Presence with the number), Cavity, Input and Commands, Time-out, Delay, Model selection, Anti-repeat, Contact, Check during tool change and Mode. If no presences are selected, the message Select or add a presence appears.

Check during tool change, visible only in the advanced view, determines with Yes or No whether the presence is also checked during tool change. During tool unloading, at the part removal stage, the machine waits – subject to operator confirmation – until all monitored presences are free. During tool change, table and head movements are blocked until a monitored presence is occupied, with a message indicating the presence, without an alarm.

Check during tool change

Position: Tool Settings > Actuators and Presences page, Presences tab, right-hand side.

Presence

The Presence field, which contains a number, holds the identification name of the presence record, as displayed in the list and on other pages (e.g. Manual Movements). This name cannot be edited during the configuration wizard.

Appearance: white text field with a green border.

Presence

Position: Equipment Settings > Actuators and Presences page, Presences tab, first row of the right-hand panel.

T02000-0.XX - Presence - Presence timeout

What this means: when a presence is expected (automatically or during a tool change), the sensor has not been triggered within the Presence time specified in the Time-out unit (Tool Settings > Actuators and Presences, Presences tab; default 2 s, 0 disables the check). In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): with the presence in Safety mode (Mode unit), the machine switches to manual mode; the automatic cycle and tool change remain blocked. In Normal mode, this is merely a warning.

Probable causes:

  • workpiece missing or incorrectly positioned (Object not present or incorrectly positioned);
  • sensor displaced or out of alignment (Check not carried out);
  • time-out too short (Insufficient time).

How to resolve:

  1. Position the workpiece correctly.
  2. Check in Machine Diagnostics > Manual Movements, under the Fixture tab, that the presence indicator turns green.
  3. If it remains grey whilst the workpiece is in place: check the sensor (maintenance technician).
  4. If it activates too late: increase the Presence time.

Reset: whilst the cycle is running, it remains stored (Reset in the Alarm Monitor); otherwise, it clears automatically.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Item missing or incorrectly positioned

How to identify the problem: the presence indicator remains grey because the part is missing or is not in the position where the sensor detects it.

Check:

  1. Check that the part is in its correct position and correctly seated.
  2. Remove and reinsert the part, observing the presence indicator in Machine Diagnostics > Manual Movements, Tool tab (green = presence active) and the sensor LED.

Remedy: position the workpiece correctly; if the indicator light does not change state with the workpiece in place, the cause is the sensor (see Check not performed or Sensors not working).

Warning Before working in the tools area, secure the machine in accordance with the user manual: moving parts.
# Not enough time

How to recognise it: the presence sensor is activated, but only after the time-out has expired, for example because the workpiece reaches the sensor following a movement.

Check:

  1. Observe automatically how long it takes for the presence indicator light to turn green.
  2. Compare this with the Presence field in the Time-out unit (Equipment settings > Actuators and presence, Presence tab; default 2 s).

Remedy: increase the Presence field, leaving a margin, and save (Save changes).

# Check not carried out

How to identify this: the part is in place but the presence sensor does not detect it: the sensor LED is off and the presence indicator light is grey.

Check:

  1. Check the sensor LED whilst the component is in place.
  2. Check the sensor’s position, mounting and cleanliness.
  3. Check the calibration (sensitivity or activation distance) in accordance with the sensor manual.

Remedy: reposition, calibrate or replace the sensor (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02001-0.XX – Presence – Absence timeout

What this means: when an absence is expected (either automatically or during a tool change), the sensor has not deactivated within the Absence time specified in the Time-out unit (Equipment settings > Actuators and Presences, Presences tab; default 2 s, 0 disables the check). In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): with the presence in Safety mode (Mode unit), the machine switches to manual mode; the automatic cycle and tool change remain blocked. In Normal mode, this is merely a warning.

Probable causes:

  • workpiece or residue in front of the sensor (Object present or incorrectly positioned);
  • sensor out of calibration or constantly active (Check not carried out);
  • time-out too short (Insufficient time).

How to resolve:

  1. Remove the workpiece and any debris.
  2. Check in Machine Diagnostics > Manual Movements, under the Tool tab, that the presence indicator turns grey.
  3. If it remains green without a workpiece: check the sensor (maintenance technician).
  4. If it takes too long to deactivate: increase the Absence time.

Reset: whilst the cycle is in progress, it remains stored (Reset in the Alarm Monitor); otherwise, it clears automatically.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Object present or incorrectly positioned

How to recognise this: the presence indicator remains green because the workpiece, or a residue, is still in front of the sensor.

Check:

  1. Check that the workpiece has been removed and that there are no scraps or residues remaining in front of the sensor.
  2. Replace and remove the workpiece whilst observing the presence indicator in Machine Diagnostics > Manual Movements, Tooling tab (grey = presence not active).

Remedy: remove the workpiece and any residue; if the indicator light remains green without a workpiece present, the cause is the sensor (see Check not performed or Sensors not working).

Warning Before working in the tools area, secure the machine in accordance with the user manual: moving parts.
# Not enough time

How to recognise it: the presence indicator switches off, but only after the time-out has expired – for example, because the part is slowly moving away from the sensor.

Check:

  1. Observe automatically how long it takes for the presence indicator to turn grey.
  2. Compare this with the Absence field in the Time-out unit (Equipment settings > Actuators and presence, Presence tab; default 2 s).

Remedy: increase the Absence field, leaving a margin, and save (Save changes).

# Check not carried out

How to recognise this: the object has been removed but the sensor continues to detect it: the sensor LED is on and the green presence indicator is lit.

Check:

  1. Check that the sensor is not detecting fixed parts of the tools or reflections.
  2. Check the sensor’s position, mounting and cleanliness.
  3. Check the calibration in accordance with the sensor manual.

Remedy: reposition, calibrate or replace the sensor (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02002-0.XX - Presence - Incorrect connector pin address

What this means: the presence sensor is assigned to a pin that does not exist on the connector: for a 24-pin connector, pins 3–24 are valid; for a 32-pin connector, pins 3–32 are valid; for a 64-pin or custom connector, pins 1–64 are valid. In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • unassigned or invalid pin (Reset inputs);
  • interface or connector changed after configuration.

How to resolve:

  1. Open the Input pop-up for the presence sensor (Equipment settings > Actuators and presence sensors, Presences tab) and check the selected pin (orange).
  2. Assign the pin from the tool’s wiring diagram.
  3. Check the interface selected in the Cavities unit.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Reset the inputs

How to recognise this: the presence indicator does not match the status of the component, or the Input pop-up does not have a valid pin.

Check:

  1. Open the Input pop-up for the presence sensor (Equipment Settings > Actuators and Presence Sensors, Presence tab): the selected pin (orange) must be the one shown in the wiring diagram and should light up green when the part is detected.
  2. Check the interface selected in the Cavity unit.
  3. Check the Contact unit (visible in the advanced view): Normally Open or Normally Closed depending on the sensor.

Remedy: correct the pin, interface or contact type and save (Save changes).

# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02003-0.XX - Presence - Absent

What this means: A movement requiring active presence (presence constraint) has been requested, but the sensor does not detect the workpiece: the movement is not executed. In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • workpiece missing or incorrectly positioned (Object not present or incorrectly positioned);
  • sensor displaced or faulty (Sensors not working);
  • pins or contacts incorrectly set (Reset the inputs).

How to resolve:

  1. Position the part correctly.
  2. Check in Machine Diagnostics > Manual Movements, under the Tools tab, that the presence indicator turns green.
  3. If it remains grey: check the sensor (maintenance technician), the pin in the Input pop-up and the Contact unit (Tool Settings > Actuators and Presences, Presence tab).
  4. Repeat the movement.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, ensure the machine is safely shut down in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Item missing or incorrectly positioned

How to identify the problem: the presence indicator remains grey because the part is missing or is not in the position where the sensor detects it.

Check:

  1. Check that the part is in its correct position and correctly seated.
  2. Remove and reinsert the part, observing the presence indicator in Machine Diagnostics > Manual Movements, Tool tab (green = presence active) and the sensor LED.

Remedy: position the workpiece correctly; if the indicator light does not change state with the workpiece in place, the cause is the sensor (see Check not performed or Sensors not working).

Warning Before working in the tools area, secure the machine in accordance with the user manual: moving parts.
# Reset the inputs

How to recognise this: the presence indicator does not match the status of the component, or the Input pop-up does not have a valid pin.

Check:

  1. Open the Input pop-up for the presence sensor (Equipment Settings > Actuators and Presence Sensors, Presence tab): the selected pin (orange) must be the one shown in the wiring diagram and should light up green when the part is detected.
  2. Check the interface selected in the Cavity unit.
  3. Check the Contact unit (visible in the advanced view): Normally Open or Normally Closed depending on the sensor.

Remedy: correct the pin, interface or contact type and save (Save changes).

# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02004-0.XX – Presence – Not absent

What this means: A movement has been requested that requires non-active presence (movement constraint), but the sensor is still detecting an object: the movement is not carried out. In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • workpiece or residue in front of the sensor (Object present or incorrectly positioned);
  • sensor out of calibration or constantly active (Sensors not functioning);
  • pins or contacts incorrectly set (Reset the inputs).

How to resolve:

  1. Remove the part or residue.
  2. Check in Machine Diagnostics > Manual Movements, under the Tools tab, that the presence indicator turns grey.
  3. If it remains green: check the sensor (maintenance technician), the pin in the Input pop-up and the Contact unit (Tool Settings > Actuators and Presences, Presence tab).
  4. Repeat the movement.

Reset: once the cause has been rectified, select Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, ensure the machine is safely shut down in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Object present or incorrectly positioned

How to recognise this: the presence indicator remains green because the workpiece, or a residue, is still in front of the sensor.

Check:

  1. Check that the workpiece has been removed and that there are no scraps or residues remaining in front of the sensor.
  2. Replace and remove the workpiece whilst observing the presence indicator in Machine Diagnostics > Manual Movements, Tooling tab (grey = presence not active).

Remedy: remove the workpiece and any residue; if the indicator light remains green without a workpiece present, the cause is the sensor (see Check not performed or Sensors not working).

Warning Before working in the tools area, secure the machine in accordance with the user manual: moving parts.
# Reset the inputs

How to recognise this: the presence indicator does not match the status of the component, or the Input pop-up does not have a valid pin.

Check:

  1. Open the Input pop-up for the presence sensor (Equipment Settings > Actuators and Presence Sensors, Presence tab): the selected pin (orange) must be the one shown in the wiring diagram and should light up green when the part is detected.
  2. Check the interface selected in the Cavity unit.
  3. Check the Contact unit (visible in the advanced view): Normally Open or Normally Closed depending on the sensor.

Remedy: correct the pin, interface or contact type and save (Save changes).

# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02005-0.XX - Presence - Incorrect command address

What this means: an output command associated with a presence (Commands pop-up, Outputs unit) does not exist or is invalid, for example because it has been deleted from the Output Commands tab. In the code, XX is the presence number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • output command deleted or invalid (Reset commands).

How to resolve:

  1. Open the Commands pop-up for presence (Tool Settings > Actuators and Presences, Presences tab, visible in the advanced view).
  2. Select the command for Presence and Absence, or Select signal if not required.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.

# Reset the controls

How to recognise it: the alarm appears after deleting or modifying the tools’ output commands.

Check:

  1. Open the Commands pop-up for presence (Equipment settings > Actuators and presences, Presence tab, visible in the advanced view).
  2. Check that the commands selected for Presence and Absence exist in the Output Commands tab.

Solution: select the commands again or Select the signal if they are not required, then save (Save changes).

# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T02006-0.XX - Presence - Anti-duplicate check

What this means: at the start of a new cycle, a presence with Anti-repeat enabled (Equipment settings > Actuators and presences, Presences tab) still detects the part welded in the previous cycle: the machine waits for it to be removed, so as not to weld it twice. In the code, XX is the presence number (from 01 to 20).

Effect: Info (grey line): the cycle does not start until the workpiece is removed; this is not a fault.

Possible causes:

  • Welded part not unloaded (Remove welded part);
  • Sensor out of calibration or constantly active (Sensors not working).

How to resolve:

  1. Remove the welded part.
  2. If the error persists: check under Machine Diagnostics > Manual Movements, Tools tab, that the presence indicator is grey; if it is green, check the sensor (maintenance technician).

Reset: the error clears automatically once the condition no longer exists.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Remove the welded part

How to recognise this: when the cycle starts, the anti-repeat check appears and the welded part is still in the tool.

Check:

  1. Check whether the part from the previous cycle is still in the tool.
  2. Check which presences have Anti-repeat set to Yes (Tool settings > Actuators and presences, Presences tab).

Remedy: remove the welded part and restart the cycle.

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.
# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Cavities

The Cavity unit indicates where the selected element is located (presence, actuator, vacuum or control):

  • Select position: the tool interface to which it is wired, selected using the buttons next to the diagram (top: head; centre: mirror; bottom: table); appears on machines with a head or a mirror;
  • Select cavity: for multi-cavity tools, the cavities to which it belongs, with a box beneath each cavity.

The selected interface determines the pins suggested in the Input pop-up and, for actuators, the available valves. This unit does not appear on machines without a head or mirror when using a single-cavity tool, nor for actuators in mirror mode.

Availability: Select position only on machines with a head or mirror (IR, HP, laser, 911MK2-IR, 912-IR and 918MK2-IR). Tooling option: Select Cavity appears with multi-cavity tools (Tool Settings > Configuration, Cavity Configuration tab).

Appearance: a row in the right-hand panel with the title in white capital letters on the left; in the centre, a schematic diagram of the head, mirror and table with the selected part highlighted in yellow and three selection buttons; on the right, diagrams of the cavities with checkboxes.

Cavities

Position: Equipment Settings > Actuators and Presences page, Presences tab, Actuators, Voids, Input Commands and Output Commands, second row of the right-hand panel.

Input

The Input button opens the input assignment pop-up, with the element’s name in the title. The pop-up displays the pins of the selected interface’s connector in the Sockets unit: tap the pin to which the sensor is connected to assign it. Below is the pin colour key:

  • Free: white;
  • Occupied: black, already assigned to another element;
  • Unusable: dark grey;
  • Selected: orange, the pin assigned to the element;
  • Active input: green indicator next to the pin where signals are present.

For actuators, the pop-up has two tabs, Rest and Work, one per sensor. For input controls, the button only appears in Plug mode. Close the pop-up using the down arrow.

Appearance: a round green button with a black gear icon next to the word INPUT.

Input

Input Pop-up

Position: Equipment Settings > Actuators and Presences page, Presences, Actuators and Input Commands tabs, right-hand panel.

Presence time-out

Set the presence timeout, that is, the maximum time required for the selected presence to activate. If the timeout is exceeded, an alarm signal is generated.

Cavities

With multi-cavity moulds, the boxes beneath the cavity diagrams indicate which cavities the element belongs to: on the Infrared Parameters page, the selected zone of the mirror, which heats the parts in the chosen cavities; on the Actuators and Presences page, the selected presence, actuator, vacuum or control. The boxes are active only when the zone is enabled. For mirror zones, during the cycle, Standby power is supplied to all enabled zones, whilst Full power 1 and Full power 2 are supplied only to the zones of the cavity currently being processed and to those assigned to both cavities; manual tests activate the zones regardless of the cavity.

Availability: tooling option: appears with multi-cavity tools (Tooling Settings > Configuration, Cavity Configuration tab).

Appearance: yellow drawings of the cavities side by side, each with a white square box underneath.

Cavities

Position: Tool Settings > Infrared Parameters page, central row, Cavities unit; Tool Settings > Actuators and Presences page, Cavities unit.

Commands

Advanced view

The Commands button opens a pop-up window that associates the tool’s output commands – configured in the Output Commands tab – with the element. In the Outputs unit, you can use a drop-down menu to select which output to activate: for presence signals, choose between Present and Absent; for actuators and vacuums, choose between the two positions. Visible only in the advanced view. The output is not a pulse: it remains active whilst the selected condition is present, with the On and Off delays set in the output command.

Availability: machine option: this appears in the Vacuum tab if the machine has at least one vacuum (Machine settings > General settings > Components, Vacuum).

Appearance: a round green button with a black gear icon next to the text COMMANDS.

Commands

Commands Pop-up

Position: Equipment Settings > Actuators and Presences page, Presences, Actuators and Vacuums tabs, right-hand panel.

Absence time-out

Set the absence timeout, that is, the maximum time required for the selected presence to deactivate. If the timeout is exceeded, an alarm signal is generated.

Delay ON

Advanced view

Set the delay time for switching on the presence, or the minimum presence detection time. The signal received by the presence is not stable when switched on. The definition of an ON time allows you to stabilise the signal received by the presence. After the minimum time entered, the signal operation will certainly be stable. The field is visible only in ADVANCED CONFIGURATION mode.

Delay OFF

Advanced view

Set the delay time for presence switch-off. The signal received by the presence is not stable when switched off. The definition of an OFF time allows you to stabilise the signal received by the presence. After the minimum time entered, the signal operation will certainly be stable. The field is visible only in ADVANCED CONFIGURATION mode.

Model selection

The Automatic checkbox in the Model Selection unit uses the presence to recognise the feature in the cavity and automatically select the model – that is, the welding parameters for the corresponding side. Only one presence can be used per side.

This unit only appears when automatic mould selection is enabled on the Tool Settings > Configuration page, with a multi-cavity tool and with the presence assigned to a single cavity in the Cavities group.

Availability: tool option: appears with a multi-cavity tool (Tool Settings > Configuration, Cavity Configuration tab) and with automatic template selection (Template Selection tab).

Appearance: a square Automatic box, ticked when active.

Model selection

Position: Equipment Settings > Actuators and Presences page, Presences tab, right-hand panel, after Time-out.

Anti-repeat

The Anti-repeat unit enables (Yes) or disables (No) the anti-repeat check on the presence sensors: when this check is enabled, a new cycle cannot be started until the workpiece welded in the previous cycle has been unloaded. When a new cycle is started, the machine waits until all presences with this check enabled are clear; by default, this check is disabled. Detection of the workpiece unloaded at the end of the cycle is a separate check, carried out using the safety light curtain.

Appearance: two round selection buttons, No and Yes.

Anti-repeat

Position: Machine Settings > Actuators and Presences page, Presences tab, right-hand panel.

Contact

Advanced view

The Contact unit indicates the type of sensor signal: Normally Open (signal present when the part is detected) or Normally Closed (signal absent when the part is detected). Visible only in the advanced view.

Appearance: two round selection buttons.

Contact

Position: Equipment Settings > Actuators and Presences page, Presences tab, right-hand panel.

Check during tool change

The Check during tool change unit determines whether presence is also checked during a tool change: Yes checks it, No excludes it from the check. Visible only in the advanced view.

With Yes, during tool unloading, at the stage of removing the workpieces, the machine waits for the operator’s confirmation that all monitored presences are clear; in tool change mode, the table and head movements remain locked until a monitored presence is occupied, with a message indicating the presence, without an alarm. Use No for sensors that remain occupied even when the tools are empty.

Appearance: row in the right-hand panel with the title in white capital letters on the left, with two round selection buttons labelled Yes and No.

Position: Equipment Settings > Actuators and Presences page, Presences tab, right-hand panel, after Contact.

Actuators

The ACTUATORS card enables the display and control of the parameters of the objects on the tool that move the tool instrumentation. The objects performing the movements can be:

  • clamps;
  • slides;
  • ejectors;
  • actuators;
  • more.

List of actuators

The left-hand side of the Actuators tab lists the configured actuators. Each row shows the number, name and two indicator lights, in the Rest and Operating columns:

  • green: the actuator is in that position;
  • grey: position not reached;
  • both red: actuator in alarm mode.

Tap a row to view its parameters on the right. The − button removes the actuator; the + button at the bottom of the list adds one to one of the free slots. If the machine does not have any actuators, No actuators available is displayed.

Appearance: rows with a round green button bearing the − symbol, the circled number, the name and two round indicator lights; at the bottom, a round green button bearing the + symbol.

List of actuators

Position: Equipment Settings > Actuators and Presences page, Actuators tab, left-hand side.

Actuator configuration

The right-hand side of the Actuators tab displays the parameters for the selected actuator, arranged in rows: name with test buttons (Actuator with the number), Mode, Cavity, valve with Input and Safety constraints, Commands, Time-out, Rest delay, Work delay and Tool change position. If no actuators are selected, the message Select or add an actuator appears.

Tool Change Position, visible only in the advanced view, selects the actuator’s position during tool change: Not used, Rest or Work. The actuator is moved to that position as soon as the machine enters tool change mode, in accordance with the tool change safety constraints; the loading and unloading procedures wait for the position to be reached and have dedicated confirmation steps.

Tool change position

Location: Tool Settings > Actuators and Presences page, Actuators tab, right-hand side.

Actuator

Enter the identification name of the selected actuator. On the side are two buttons: work and rest. They allow a work and rest test of the selected actuator if the machine is set in non-automatic cycle. The LED associated with the button provides more specific information on the action of the selected test:

  • green LED: work/rest achieved;
  • yellow LED: work/rest in operation;
  • red LED: work/rest in error; an alarm is triggered.
T01000-0.XX - Actuator - Rest position timeout

What this means: following the sleep command, the sleep sensor did not activate within the Sleep time specified in the Time-out unit (Equipment settings > Actuators and Presence, Actuators tab; default 5 s, −1 disables the check). In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • stroke obstructed (Movement not completed);
  • insufficient air supply or damaged hoses (Pneumatic check);
  • sensor displaced or faulty (Sensors not working);
  • time-out shorter than the stroke (Insufficient time).

How to resolve:

  1. Reset and select Standby in Machine Diagnostics > Manual Movements, Equipment tab: the button must display a green ring.
  2. If the actuator does not move: clear the stroke, check the air supply and hoses (maintenance technician).
  3. If it moves but the green halo does not appear: check the sensor and pins (Input pop-up, Rest tab).
  4. If it is delayed: increase the Rest time.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
# Move not completed

How to identify it: the actuator stops before reaching the position or reaches it without the sensor sending signals.

Check:

  1. Control the actuator from Machine Diagnostics > Manual Movements, Tools tab, and check whether it reaches the position: the button must display a green halo.
  2. If it stops before reaching the position: check for mechanical obstructions, incorrectly positioned parts or other actuators in the travel path.
  3. If it reaches the position but the green halo does not appear: in the actuator’s Input pop-up (Equipment settings > Actuators and sensors, Actuators tab), under the Idle or Work tab, the assigned pin must light up green when the actuator is in position.

Remedy: clear the travel path; correct the assigned pin (operator authorised to access tool settings) or the sensor wiring (maintenance technician).

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.
# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Not enough time

How to recognise this: the actuator reaches the position, but only after the time-out has expired (the green halo appears late).

Check:

  1. Control the actuator via Machine Diagnostics > Manual Movements, Tool tab, and estimate the travel time.
  2. Compare this with the Idle and Operating fields in the Timeout unit (Equipment settings > Actuators and Presences, Actuators tab).

Remedy: if the stroke is smooth but slow, increase the time-out, leaving a margin; if the stroke has become slower than usual, first check the air supply and flow regulators (maintenance technician).

# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01001-0.XX – Actuator – Working position timeout

What this means: following the work command, the work sensor did not activate within the Work time specified in the Time-out unit (Equipment settings > Actuators and Presences, Actuators tab; default 5 s, −1 disables the check). In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • stroke obstructed (Movement not completed);
  • insufficient air or damaged pipes (Pneumatic control);
  • sensor displaced or faulty (Sensors not working);
  • time-out shorter than the stroke (Insufficient time).

How to resolve:

  1. Reset and select Work in Machine Diagnostics > Manual Movements, Tools tab: the button must display a green ring.
  2. If the actuator does not move: clear the stroke, check the air supply and hoses (maintenance technician).
  3. If it moves but the indicator does not appear: check the sensor and pins (Input pop-up, Work tab).
  4. If it is delayed: increase the Job time.

Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance by a qualified maintenance technician.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Move not completed

How to identify it: the actuator stops before reaching the position or reaches it without the sensor sending signals.

Check:

  1. Control the actuator from Machine Diagnostics > Manual Movements, Tools tab, and check whether it reaches the position: the button must display a green halo.
  2. If it stops before reaching the position: check for mechanical obstructions, incorrectly positioned parts or other actuators in the travel path.
  3. If it reaches the position but the green halo does not appear: in the actuator’s Input pop-up (Equipment settings > Actuators and sensors, Actuators tab), under the Idle or Work tab, the assigned pin must light up green when the actuator is in position.

Remedy: clear the travel path; correct the assigned pin (operator authorised to access tool settings) or the sensor wiring (maintenance technician).

Warning Before working in the tool area, secure the machine in accordance with the user manual: moving parts.
# Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
# Not enough time

How to recognise this: the actuator reaches the position, but only after the time-out has expired (the green halo appears late).

Check:

  1. Control the actuator via Machine Diagnostics > Manual Movements, Tool tab, and estimate the travel time.
  2. Compare this with the Idle and Operating fields in the Timeout unit (Equipment settings > Actuators and Presences, Actuators tab).

Remedy: if the stroke is smooth but slow, increase the time-out, leaving a margin; if the stroke has become slower than usual, first check the air supply and flow regulators (maintenance technician).

# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01002-0.XX – Actuator – Rest position not released

What this means: after the job command, when the time-out expires (the Job field in the Time-out unit, Equipment settings > Actuators and Presences, Actuators tab), the idle sensor is still active: either the actuator has not started, or the sensor remains on even though the actuator has moved. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until a reset is performed.

Probable causes:

  • actuator held in position (Actuator jammed);
  • no air supply or valve not controlled (Pneumatic control);
  • idle sensor always active (Sensors not working).

How to resolve:

  1. Reset and select Work in Machine Diagnostics > Manual Movements, Tools tab, whilst observing the actuator.
  2. If it does not start: release the components holding it in place, check Safety constraints, air supply and valve (maintenance technician).
  3. If it starts but the idle sensor LED remains lit: adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
# Actuator jammed

How to recognise this: the actuator does not move, or does not move from its position, when commanded.

Check:

  1. Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
  2. Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
  3. Check that the stroke is free from mechanical obstructions.

Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.
# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01003-0.XX - Actuator - Operating position not released

What this means: after the standby command, when the time-out expires (the Standby field in the Time-out unit, Equipment settings > Actuators and Presences, Actuators tab), the work sensor is still active: either the actuator has not started, or the sensor remains on even though the actuator has moved. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until a reset is performed.

Probable causes:

  • actuator held in position (Actuator jammed);
  • no air supply or valve not controlled (Pneumatic control);
  • work sensor constantly active (Sensors not working).

How to resolve:

  1. Reset and select Rest in Machine Diagnostics > Manual Movements, Tool tab, whilst observing the actuator.
  2. If it does not start: release the components holding it in place, check Safety constraints, air supply and valve (maintenance technician).
  3. If it starts but the work sensor LED remains lit: adjust or replace the sensor (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
# Actuator jammed

How to recognise this: the actuator does not move, or does not move from its position, when commanded.

Check:

  1. Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
  2. Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
  3. Check that the stroke is free from mechanical obstructions.

Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.
# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01004-0.XX – Actuator – External alarm

What this means: external actuator alarm, i.e. a fault signalled by a device connected to the actuator rather than by its position sensors. In current versions of the machine software, this alarm is provided for but is not activated. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): none.

If this appears: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

T01005-0.XX - Actuator - Both position feedback signals

What this means: the actuator’s idle and operating sensors are active simultaneously: the actuator’s position cannot be determined. Control is continuous. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • a sensor also detects the opposite position (Sensor positioning);
  • faulty sensor or sensor always active (Sensors not working);
  • same pin assigned to both sensors.

How to resolve:

  1. Move the actuator via Machine Diagnostics > Manual Movements, Tools tab, whilst observing the LEDs: only one sensor should light up in each position.
  2. If an LED remains lit at all times: reposition or replace the sensor (maintenance technician).
  3. If the LEDs are correct: check in the Input pop-up (Equipment settings > Actuators and presence, Actuators tab) that Rest and Work have different pins.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Sensor positioning

How to identify this: the component’s two position sensors are active at the same time.

Check:

  1. Move the component to one position and check that only the LED for the corresponding sensor is lit.
  2. Repeat in the other position.
  3. Check that each sensor is securely fitted and detects only its own position.

Remedy: reposition or replace the sensor that remains active (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01006-0.XX – Actuator – Both commands

What this means: the actuator receives both the ‘rest’ and ‘work’ commands simultaneously, for example from two external commands linked in the Input unit of the actuator pop-up window (Equipment settings > Cycle settings). In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • external ‘Idle’ and ‘Work’ commands active simultaneously (Reset the commands);
  • external device sending both signals.

How to resolve:

  1. Note down the input commands associated with Rest and Work (Equipment settings > Cycle settings, actuator pop-up, Inputs unit).
  2. Check in Machine diagnostics > PLC that they are not active simultaneously.
  3. Correct the association or the device sending the commands (maintenance technician).

Reset: once the cause has been eliminated, press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Reset the controls

How to recognise it: the Both commands alarm appears when the actuator’s external commands are activated.

Check:

  1. In Equipment settings > Cycle settings, in the actuator pop-up window, under the Input unit, note down the input commands selected for Idle and Operate.
  2. Check in the Signals tab under Machine Diagnostics > PLC that the two commands are not active at the same time.

Remedy: pair commands so that they cannot be active simultaneously, or rectify the device sending them (maintenance technician).

# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01007-0.XX - Actuator - Not in the rest position

What this means: A movement (table, head, other actuators, repositioning) has been requested that requires the actuator to be in the rest position, but the rest position sensor is not active: the safe position constraint is not met and the movement is not executed. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • actuator out of position or stuck (Actuator jammed);
  • air pressure dropped or absent (Pneumatic control);
  • rest position sensor displaced or faulty (Sensors not working).

How to resolve:

  1. Reset and select Rest in Machine Diagnostics > Manual Movements, Tools tab: the button must display a green ring.
  2. If the actuator does not move: check for obstructions, air supply and the valve (maintenance technician).
  3. If it is in the rest position but the green halo does not appear: check the LED and the sensor position (maintenance technician).
  4. Repeat the required movement.

Reset: once the cause has been rectified, select Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
# Actuator jammed

How to recognise this: the actuator does not move, or does not move from its position, when commanded.

Check:

  1. Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
  2. Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
  3. Check that the stroke is free from mechanical obstructions.

Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.
# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01008-0.XX – Actuator – Not in operating position

What this means: A movement (table, head, other actuators, repositioning) has been requested that requires the actuator to be in operation, but the operational sensor is not active: the safe position constraint is not met and the movement is not executed. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The actuator valves are not controlled until the alarm is reset.

Probable causes:

  • actuator has retracted or is stuck (Actuator jammed);
  • air pressure has dropped during the cycle (Pneumatic control);
  • work sensor displaced or faulty (Sensors not working).

How to resolve:

  1. Reset and select Operation in Machine Diagnostics > Manual Movements, Tool tab: the button must display a green ring.
  2. If the actuator does not move: check for obstructions, air supply and the valve (maintenance technician).
  3. If it is operating but the green halo does not appear: check the LED and the sensor position (maintenance technician).
  4. Repeat the required movement.

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working in the vicinity of the tool, secure the machine in accordance with the user manual: moving parts.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
# Actuator jammed

How to recognise this: the actuator does not move, or does not move from its position, when commanded.

Check:

  1. Check that another part of the tool (for example, a shutter or a clamp) is not preventing its movement.
  2. Check the actuator’s Safety Constraints (Equipment Settings > Actuators and Presences, Actuators tab): if the other actuators are not in the required position, the movement will not be executed.
  3. Check that the stroke is free from mechanical obstructions.

Remedy: release the components holding it in place and repeat the command from Machine Diagnostics > Manual Movements, Equipment tab; check for mechanical obstructions and seals whilst the machine is in a safe state (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician only.
# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01009-0.XX – Actuator – Incorrect control address

What this means: a command associated with the actuator refers to a non-existent input or output command, for example one that was deleted after the association was made. This is a tool configuration error. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • command deleted or invalid (Reset commands).

How to resolve:

  1. Check the outputs in the actuator’s Commands pop-up (Tooling Settings > Actuators and Presences, Actuators tab, visible in the advanced view).
  2. Check the external commands in the Input unit of the actuator pop-up (Tool settings > Cycle settings).
  3. Choose the correct command or Select signal if it is not required.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.

# Reset the controls

How to recognise it: the alarm appears after deleting or modifying the tools’ input or output commands.

Check:

  1. Open the actuator’s Commands pop-up (Equipment Settings > Actuators and Presences, Actuators tab, visible in the advanced view) and check that the selected outputs exist in the Output Commands tab.
  2. Check the external commands in the Input unit of the actuator pop-up (Tool Settings > Cycle Settings).

Remedy: select the correct commands again or Select Signal if they are not required, then save (Save Changes).

# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01010-0.XX – Actuator – Incorrect valve address

What this means: the valve assigned to the actuator is invalid: the valve number is outside the machine’s range (up to 10). The valve menu is next to the Input button (Equipment settings > Actuators and presences, Actuators tab). In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • valve not selected or does not exist on the interface (Reset the valve);
  • tools created on a machine with different valves.

How to resolve:

  1. In the Cavities unit, check the interface on which the actuator is mounted.
  2. Select the valve that controls the actuator from the menu.
  3. Test the actuator via Machine Diagnostics > Manual Movements, Tooling tab.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Reset the valve

How to recognise it: the alarm appears on a new actuator or after changing the interface in the Cavity unit.

Check:

  1. Check in the Cavity unit (Tooling settings > Actuators and presences, Actuators tab) the interface on which the actuator is mounted.
  2. Check in the valve menu, next to the Input button, that the valve controlling the actuator is selected.

Remedy: correct the interface and valve, save (Save changes) and test the actuator via Machine diagnostics > Manual movements, Equipment tab. With the machine option General valve pack, configured by CEMAS, the valves suggested are always those shown on the table.

# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T01011-0.XX - Actuator - Incorrect actuator connector pin address

What this means: an actuator sensor is assigned to a pin that does not exist on the connector: for a 24-pin connector, pins 3–24 are valid; for a 32-pin connector, pins 3–32; and for a 64-pin or custom connector, pins 1–64. In the code, XX is the actuator number (from 01 to 20).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Possible causes:

  • unassigned or invalid pin (Reset inputs);
  • interface or connector changed after configuration.

How to resolve:

  1. Open the actuator’s Input pop-up (Machine Settings > Actuators and Presences, Actuators tab) and check the selected pin (orange) in the Idle and Work tabs.
  2. Assign the pins from the tool’s wiring diagram.
  3. Check the interface selected in the Cavity unit.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Reset the inputs

How to recognise this: in the actuator’s Input pop-up, the selected pin (orange) is missing from one of the tabs, or an invalid pin has been assigned to the plug.

Check:

  1. Open the actuator’s Input pop-up (Equipment settings > Actuators and presences, Actuators tab) and check the Rest and Work tabs.
  2. Compare the pins with the tool’s wiring diagram.
  3. Check that the interface selected in the Cavities unit is the one to which the sensors are wired.

Remedy: assign the correct pins and save (Save changes).

# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Cavities

The Cavity unit indicates where the selected element is located (presence, actuator, vacuum or control):

  • Select position: the tool interface to which it is wired, selected using the buttons next to the diagram (top: head; centre: mirror; bottom: table); appears on machines with a head or a mirror;
  • Select cavity: for multi-cavity tools, the cavities to which it belongs, with a box beneath each cavity.

The selected interface determines the pins suggested in the Input pop-up and, for actuators, the available valves. This unit does not appear on machines without a head or mirror when using a single-cavity tool, nor for actuators in mirror mode.

Availability: Select position only on machines with a head or mirror (IR, HP, laser, 911MK2-IR, 912-IR and 918MK2-IR). Tooling option: Select Cavity appears with multi-cavity tools (Tool Settings > Configuration, Cavity Configuration tab).

Appearance: a row in the right-hand panel with the title in white capital letters on the left; in the centre, a schematic diagram of the head, mirror and table with the selected part highlighted in yellow and three selection buttons; on the right, diagrams of the cavities with checkboxes.

Cavities

Position: Equipment Settings > Actuators and Presences page, Presences tab, Actuators, Voids, Input Commands and Output Commands, second row of the right-hand panel.

Mode

Select the type of actuator selected. The actuator mode is automatically selected, namely, the generic mode that allows freer management of the object in the cyclogram. If I select one of the more specific actuator types present, it is no longer possible to manage the actuator in the cyclogram because it is automatically managed based on its function.

Labelling of vouchers

The Voucher Marking mode in the Modes unit dedicates the actuator to marking correctly welded parts, for example using a punch that leaves a mark on the part. Marking takes place at the end of the cycle, during the marking and reject confirmation step, and only if the cycle is successful.

Appearance: round Goods Marking selection button, in the second column of the Mode unit.

Position: Equipment Settings > Actuators and Presences page, Actuators tab, right-hand panel, Mode unit.

Waste marking

The Scrap Marking mode in the Modes unit dedicates the actuator to marking scrap pieces, so that they can be identified even when removed from the machine. Marking takes place at the end of the cycle, during the marking and reject confirmation step, and only if the cycle is a scrap cycle.

Appearance: round Scrap Marking selection button, below Goods Marking.

Position: Equipment Settings > Actuators and Presences page, Actuators tab, right-hand panel, Mode unit.

Workpiece piece taking slide

The Workpiece Gripper Slide mode in the Mode unit dedicates the actuator to the workpiece gripper slide, which moves the workpiece into the gripping position and returns it once gripping is complete. Only one actuator on the tool can be set to this mode: on the others, the button is greyed out.

The slide operates in Simple piece taking mode: it moves into position before piece taking and returns to rest after the piece has been released. On IR, HP and IR cam-type vibration machines, the machine controls the slide itself during the piece taking steps and leaves it at rest if the piece taking mode does not use it; on other machines, the slide moves according to the rows in the piece taking cycle table (Equipment Settings > Cycle Settings).

Availability: tool option: appears when piece taking is active (Tool Settings > Configuration, Piece Taking tab).

Appearance: round selection button Workpiece Gripper Slide, in the last column of the Mode unit.

Position: Equipment Settings > Actuators and Presences page, Actuators tab, right-hand panel, Mode unit, last column.

Select the valve

From the drop-down menu that appears, select the valve present on the machine relating to the chosen tool interface.

Input

The Input button opens the input assignment pop-up, with the element’s name in the title. The pop-up displays the pins of the selected interface’s connector in the Sockets unit: tap the pin to which the sensor is connected to assign it. Below is the pin colour key:

  • Free: white;
  • Occupied: black, already assigned to another element;
  • Unusable: dark grey;
  • Selected: orange, the pin assigned to the element;
  • Active input: green indicator next to the pin where signals are present.

For actuators, the pop-up has two tabs, Rest and Work, one per sensor. For input controls, the button only appears in Plug mode. Close the pop-up using the down arrow.

Appearance: a round green button with a black gear icon next to the word INPUT.

Input

Input Pop-up

Position: Equipment Settings > Actuators and Presences page, Presences, Actuators and Input Commands tabs, right-hand panel.

Cavities

With multi-cavity moulds, the boxes beneath the cavity diagrams indicate which cavities the element belongs to: on the Infrared Parameters page, the selected zone of the mirror, which heats the parts in the chosen cavities; on the Actuators and Presences page, the selected presence, actuator, vacuum or control. The boxes are active only when the zone is enabled. For mirror zones, during the cycle, Standby power is supplied to all enabled zones, whilst Full power 1 and Full power 2 are supplied only to the zones of the cavity currently being processed and to those assigned to both cavities; manual tests activate the zones regardless of the cavity.

Availability: tooling option: appears with multi-cavity tools (Tooling Settings > Configuration, Cavity Configuration tab).

Appearance: yellow drawings of the cavities side by side, each with a white square box underneath.

Cavities

Position: Tool Settings > Infrared Parameters page, central row, Cavities unit; Tool Settings > Actuators and Presences page, Cavities unit.

Commands

Advanced view

The Commands button opens a pop-up window that associates the tool’s output commands – configured in the Output Commands tab – with the element. In the Outputs unit, you can use a drop-down menu to select which output to activate: for presence signals, choose between Present and Absent; for actuators and vacuums, choose between the two positions. Visible only in the advanced view. The output is not a pulse: it remains active whilst the selected condition is present, with the On and Off delays set in the output command.

Availability: machine option: this appears in the Vacuum tab if the machine has at least one vacuum (Machine settings > General settings > Components, Vacuum).

Appearance: a round green button with a black gear icon next to the text COMMANDS.

Commands

Commands Pop-up

Position: Equipment Settings > Actuators and Presences page, Presences, Actuators and Vacuums tabs, right-hand panel.

Safety requirements

The Safety Constraints button opens a pop-up window that defines the positions the other actuators must be in for the selected actuator to move, in order to avoid collisions. The pop-up has three tabs: Manual, Automatic and Tool Change, one for each machine mode; on the left, you select the movement (Rest or Work) and, in the table, for each other actuator, the required position: Not specified, Rest or Work.

If the constraint is not met, the movement is not executed – without triggering an alarm – and the other actuators are not moved. In automatic mode, the cycle remains paused until the cycle phases move the other actuator to the required position.

Appearance: a round green button with a black gear icon next to the text SAFETY CONSTRAINTS; in the pop-up, lines displaying the actuator’s name and three selection buttons, greyed out for the actuator itself.

Safety Constraints

Safety Constraints Pop-up

Position: Equipment Settings > Actuators and Presences page, Actuators tab, right-hand panel, to the right of the Input button.

Rest time-out

The Rest field in the Time out unit is the maximum time, in seconds (s), within which the actuator must reach its rest position; if this time is exceeded, an alarm is triggered, both when the actuator fails to complete its movement and when the actuator’s sensors are not functioning correctly.

Appearance: white field with a green border followed by s.

Time out

Position: Equipment Settings > Actuators and Presence page, Actuators tab, Time out unit, on the left.

Time out from work

The Work field in the Time out unit is the maximum time, in seconds (s), within which the actuator must reach its working position; if this time is exceeded, an alarm is triggered, both when the actuator fails to complete the movement and when the actuator’s sensors are not functioning correctly.

Appearance: white field with a green border followed by s.

Time out

Position: Equipment Settings > Actuators and Presence page, Actuators tab, Time out unit, on the right.

Delayed sleep

Advanced view

The Rest delay unit has two fields, On and Off, in seconds (s): the time for which the rest sensor signal must remain on or off before it is considered stable. If the actuator does not have a sensor, this delay affects the time taken to reach the rest position. Visible only in the advanced view.

Appearance: two white fields with a green border followed by s.

Rest delay

Position: Equipment Settings > Actuators and Presences page, Actuators tab, right-hand panel, under Time-out.

Late for work

Advanced view

The Work delay unit has two fields, On and Off, in seconds (s): the time for which the work sensor signal must remain on or off before it is considered stable. If the actuator does not have a sensor, this delay affects the time taken to reach the working position. Visible only in the advanced view.

Appearance: two white fields with a green border followed by s.

Work delay

Position: Equipment Settings > Actuators and Presence page, Actuators tab, right-hand panel, under Rest delay.

Tool change position

The Tool Change Position unit uses a drop-down menu to select where the actuator should be positioned during a tool change: Not used (the actuator is not moved), Rest or Work. Visible only in the advanced view.

The actuator is moved to the selected position as soon as the machine enters tool change mode, in accordance with the Safety Constraints in the Tool Change tab; the tool loading and unloading procedures wait until this position has been reached. This is used, for example, to keep clamps open to remove workpieces or to move a slide out of the way.

Appearance: row in the right-hand panel with the title in white capital letters on the left, with a drop-down menu to the left.

Position: Tool Settings > Actuators and Presences page, Actuators tab, last row of the right-hand panel.

Vacuums

The VACUUMS card enables the display and control of the parameters of the objects on the tool that hold the piece to be welded by means of vacuum. The holding objects can be:

  • suction cups;
  • vacuum cavities;
  • more.

List of vacancies

The left-hand side of the Vacuum tab lists the configured vacuum systems. Each row shows the number, name and two indicators in the Blow and Vacuum columns:

  • Green Blow: the blow function is active, to detach the part;
  • Green Vacuum: the vacuum has been established;
  • Both red: vacuum alarm.

Tap a row to view its parameters on the right. The − button removes the vacuum; the + button at the bottom of the list adds one from those provided by the machine but not yet used. If the machine does not support vacuums, No vacuums available is displayed.

Appearance: rows with a round green button bearing the − symbol, the number in a circle, the name and two round indicator lights; at the bottom, a round green button bearing the + symbol.

List of slots

Position: Equipment Settings > Actuators and Presences page, Slots tab, left-hand side.

Configuration of vacuums

The right-hand side of the Vacuum tab displays the parameters of the selected vacuum, arranged in rows: name with test buttons (Vacuum with the number), Cavities, Times, Commands and Delay. If no vacuums are selected, the message Select or add a vacuum appears.

The Delay unit, visible only in the advanced view, has two fields, On and Off, in seconds (s), which filter the switching on and off of the vacuum signal. The delay applies to the vacuum signal once it has been reached, not to the valve; the time-outs, on the other hand, use the unfiltered signal.

Position: Equipment Settings > Actuators and Presences page, Vacuum tab, right-hand side.

Vacuum

The Vacuum unit, alongside the number, contains the vacuum’s identification name – to be entered in the field – and the Blow and Vacuum buttons, which, when the machine is in manual mode, activate the blow or suction functions to test them. The name cannot be edited during the configuration wizard.

Availability: machine option: appears if the machine has at least one vacuum (Machine Settings > General Settings > Components, Vacuums).

Appearance: a white text field and two green buttons labelled BLOW and VACUUM; Vacuum has a green outline when the vacuum has been reached, Blow when blowing is active; if the vacuum is in alarm mode, the outline is red.

Vacuum

Position: Equipment Settings > Actuators and Presences page, Vacuum tab, first row of the right-hand panel.

T03000-0.XX - Vacuum - Vacuum timeout

What this means: with the vacuum valve open, the vacuum switch did not signal a vacuum within the Vacuum timeout set in the Timings unit (Equipment settings > Actuators and Presences, Vacuum tab; default 10 s). In the code, XX is the vacuum number (from 01 to 10).

Effect: Warning (yellow line): the workpiece is not being held; the valve remains open.

Probable causes:

  • workpiece not correctly positioned (Vacuum not reached);
  • damaged suction cups or hoses (Check holding, Pneumatic check);
  • vacuum switch out of calibration or faulty (Check not carried out);
  • time-out too short (Insufficient time).

How to resolve:

  1. Reposition the workpiece.
  2. Activate Vacuum in Machine Diagnostics > Manual Movements, Tool tab: the button must display a green ring.
  3. If the green halo does not appear: check the suction cups, hoses and vacuum switch (maintenance technician).
  4. If the vacuum is delayed: increase the Vacuum time-out.

Reset: this disappears automatically once the vacuum is achieved.

Safety:

Warning Before carrying out any work on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Vacuum not achieved

How to recognise it: when the vacuum is activated, the green ring around the Vacuum button does not appear.

Check:

  1. Check that the workpiece is securely held by the suction cups or in the cavity.
  2. Check the vacuum switch calibration (typical value −0.65 bar) and its LED.
  3. Activate Vacuum via Machine Diagnostics > Manual Movements, under the Tool tab, and check whether a vacuum is achieved.

Remedy: reposition the workpiece; calibrate or replace the vacuum switch (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
# Check on withholding

How to recognise it: a vacuum is difficult to achieve, is lost shortly afterwards, or remains even after the valve is released.

Check:

  1. Check that the suction cups are undamaged, clean and not deformed.
  2. Check the vacuum lines and fittings: ensure no hoses are punctured, blocked or disconnected.
  3. Activate Vacuum and Blow from Machine Diagnostics > Manual Movements, under the Tools tab, whilst listening for any leaks.

Remedy: replace damaged suction cups or hoses and tighten the fittings (maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
# Check not carried out

How to identify this: the part is held in place but the vacuum switch does not signal a vacuum (LED off, no glow around Vacuum).

Check:

  1. Check the electrical connection and the vacuum switch LED.
  2. Check the calibration of the vacuum switch.

Remedy: Reconnect, calibrate or replace the vacuum switch (maintenance technician).

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
# Not enough time

How to recognise it: the vacuum is achieved, but only after the Vacuum Timeout has expired.

Check:

  1. Select Empty from Machine Diagnostics > Manual Movements, under the Equipment tab, and estimate the time required.
  2. Compare this with the Empty Timeout in the Times unit (Equipment Settings > Actuators and Presences, Empties tab; default 10 s).

Remedy: increase the Vacuum Timeout, allowing for a margin, and save (Save changes); if the vacuum is taking longer than usual, first check for leaks and the pump (maintenance technician).

# Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T03001-0.XX - Vacuum - Invalid pump

What this means: the vacuum is associated with an invalid pump: the machine supports a maximum of 4 pumps and the assigned number is outside the valid range. This association is part of the machine’s vacuum configuration (Machine Settings > General Settings > Components), set by CEMAS. In the code, XX is the vacuum number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The vacuum valve is closed.

Probable causes:

  • Incorrect pump configuration (Incorrect configuration).

How to resolve:

  1. Check in Equipment Settings > Actuators and Presences, under the Vacuum tab, that the tool is set to use vacuum XX.
  2. If so, have the vacuum and pump configuration checked (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited **Machine settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Incorrect configuration

How to identify it: the Invalid pump alarm appears as soon as the tool uses a vacuum.

Check:

  1. Note down the vacuum number (XX) indicated in the alarm code.
  2. Check under Equipment Settings > Actuators and Presences, in the Vacuums tab, that the tool is set to use that vacuum.

Remedy: the pump for each vacuum and the machines’ pumps are configured by CEMAS: contact CEMAS Elettra support (CEMAS technician).

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T03002-0.XX – Vacuum – Vacuum not released

What this means: with the vacuum valve closed, the vacuum switch still signals a vacuum after 5 s (fixed value): the workpiece may not be released. In the code, XX is the vacuum number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked.

Probable causes:

  • workpiece jammed or insufficient blow-off (Workpiece not released);
  • valve failing to close or blocked pipe (Check pneumatic system, Check retention);
  • vacuum switch constantly active (Sensors not working).

How to resolve:

  1. Initiate Blow in Machine Diagnostics > Manual Movements, Tools tab: the part should detach and the Vacuum indicator should go out.
  2. If the workpiece remains attached: increase the Blow time (Equipment settings > Actuators and presences, Vacuum tab, Times unit) and check that it is not jammed.
  3. If it detaches but the vacuum remains indicated: check the valve and vacuum switch (maintenance technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
# Check on withholding

How to recognise it: a vacuum is difficult to achieve, is lost shortly afterwards, or remains even after the valve is released.

Check:

  1. Check that the suction cups are undamaged, clean and not deformed.
  2. Check the vacuum lines and fittings: ensure no hoses are punctured, blocked or disconnected.
  3. Activate Vacuum and Blow from Machine Diagnostics > Manual Movements, under the Tools tab, whilst listening for any leaks.

Remedy: replace damaged suction cups or hoses and tighten the fittings (maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Unreleased track

How to recognise it: after the blow, the part remains attached to the suction cups or in the cavity.

Check:

  1. Initiate Blow from Machine Diagnostics > Manual Movements, Tool tab, and observe whether the part detaches.
  2. Check the Blow time in the Timings unit (Tool settings > Actuators and presences, Vacuum tab).
  3. Check that the part is not jammed in its seat.

Remedy: increase the Blow time and save (Save changes); safely remove the part from the machine.

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance by a qualified maintenance technician.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T03003-0.XX - Vacuum - Incorrect command address

What this means: a command associated with a vacuum (On and Off outputs in the Commands pop-up or external cycle commands) does not exist or is invalid, for example because it has been deleted. In the code, XX is the vacuum number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The vacuum valve is closed.

Probable causes:

  • command deleted or invalid (Reset commands).

How to resolve:

  1. Check the outputs in the Commands pop-up for the vacuum (Equipment Settings > Actuators and Presences, Vacuum tab, visible in the advanced view).
  2. Check the external commands in the vacuum pop-up (Equipment Settings > Cycle Settings, Input unit).
  3. Choose the correct command or Select signal if not required.

Reset: once the configuration has been corrected, save (Save changes) and press Reset in the Alarm Monitor.

If the problem persists: contact CEMAS Elettra support (Machine diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm history tab) and the checks carried out.

# Reset the controls

How to recognise it: the alarm appears after deleting or modifying the tools’ input or output commands.

Check:

  1. Open the Commands pop-up for the vacuum (Equipment Settings > Actuators and Presences, Vacuum tab, visible in the advanced view) and check the On and Off outputs.
  2. Check the external commands in the Inputs unit of the vacuum pop-up (Tool Settings > Cycle Settings).

Remedy: select the commands again or Select Signal if they are not required, then save (Save Changes).

# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T03004-0.XX - Vacuum - Input vacuum not configured

What this means: the tool is using vacuum XX, which is present on the machine but for which the vacuum switch input has not been enabled: the vacuum cannot be controlled. The input is configured in the Tool tab under Machine Settings > General Settings > Components, a CEMAS setting. A vacuum that is not present on the machine does not trigger an alarm. In the code, XX is the vacuum number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The vacuum valve is closed.

Probable causes:

  • Vacuum switch input not configured (Set inputs);
  • Tool using a vacuum not provided for on this machine.

How to resolve:

  1. Check in Equipment Settings > Actuators and Presences, under the Vacuum tab, that vacuum XX is required; if it is not required, delete it and save.
  2. If it is required, have the vacuum switch input configured (CEMAS technician).

Reset: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Prohibited **Machine Settings** may only be modified by authorised CEMAS Elettra personnel.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Set up the inputs

How to recognise it: the ‘Vacuum input not configured’ alarm appears as soon as the tools use vacuum.

Check:

  1. Check in Equipment Settings > Actuators and Presences, under the Vacuum tab, that the tool is set to use vacuum XX.
  2. If it is not required, remove it from the tool and save.

Remedy: if the vacuum is required, the vacuum switch input must be configured in the Equipment tab under Machine Settings > General Settings > Components by a CEMAS technician.

Prohibited The **Machine settings** may only be modified by authorised CEMAS Elettra personnel.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

T03005-0.XX – Vacuum – Vacuum loss

What this means: a vacuum was automatically established but was lost whilst the valve was still open. Control is suspended whilst the machine awaits loading or the start of the cycle. In the code, XX is the vacuum number (from 01 to 10).

Effect: Alarm (red line): the machine switches to manual mode; the automatic cycle and tool change remain blocked. The valve remains open.

Probable causes:

  • workpiece displaced or detached (Object incorrectly positioned);
  • leaks or damaged suction cups (Check grip, Pneumatic check);
  • vacuum switch out of calibration (Sensors not working).

How to resolve:

  1. Reposition the workpiece.
  2. Select Vacuum in Machine Diagnostics > Manual Movements, Tools tab: the green ring must remain steady.
  3. If it goes out: check suction cups, fittings and vacuum switch (maintenance technician).

Recovery: once the cause has been rectified, press Reset in the Alarm Monitor.

Safety:

Warning Before working on pipes, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician intervention.

If the problem persists: contact CEMAS Elettra support (Machine Diagnostics > Support), providing the full code, model and serial number, the time of the alarm (Alarm History tab) and the checks carried out.

# Pneumatic tyre pressure check

How to recognise it: pneumatic movements are slow, incomplete or absent, or air leaks can be heard.

Check:

  1. Check the supply air pressure on the machine’s pressure gauge.
  2. Check that the component’s hoses are not kinked, crushed, punctured or disconnected.
  3. Check that the valve is being actuated (output active in Machine Diagnostics > PLC) and that air is reaching the component.

Remedy: restore the pressure, replace damaged hoses and fittings, clean or replace the valve (by a maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Work to be carried out by a maintenance technician.
# Check on withholding

How to recognise it: a vacuum is difficult to achieve, is lost shortly afterwards, or remains even after the valve is released.

Check:

  1. Check that the suction cups are undamaged, clean and not deformed.
  2. Check the vacuum lines and fittings: ensure no hoses are punctured, blocked or disconnected.
  3. Activate Vacuum and Blow from Machine Diagnostics > Manual Movements, under the Tools tab, whilst listening for any leaks.

Remedy: replace damaged suction cups or hoses and tighten the fittings (maintenance technician).

Warning Before working on hoses, valves or actuators, secure the machine in accordance with the user manual and release the compressed air. Maintenance technician required.
# Sensors not working

How to recognise this: the status displayed by the machine does not correspond to reality: the position or presence does not change, the sensor LED remains on or off, or a measured value is fixed or out of range.

Check:

  1. Move the component into the condition to be detected (manually, where possible, via Machine Diagnostics > Manual Movements) and observe the sensor LED.
  2. Check that the signals are reaching the PLC: in Machine Diagnostics > PLC, on the Card Monitoring tab, the input status must change, or the analogue value must be plausible.
  3. Check the sensor’s connector, cable, mounting and calibration.

Remedy: Reconnect, secure or calibrate the sensor; if it is faulty, replace it with an equivalent one (maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Item in the wrong place

How to recognise this: the vacuum is lost during the cycle because the workpiece has moved or is not seated properly.

Check:

  1. Check that the workpiece is in its correct position and is resting on all the suction cups.
  2. Check that no movement of the tools displaces it during the cycle.

Remedy: reposition the workpiece; if it always shifts at the same point in the cycle, have the tools checked (by a maintenance technician).

Warning Before working in the vicinity of the tools, secure the machine in accordance with the user manual: moving parts.
# Further information

How to recognise it: the alarm reoccurs after a Reset, or the checks specified in the alarm entry do not resolve it.

Check:

  1. Note down the full alarm code, including the zone and element number, and the time (page Machine Status > Alarm Monitor, Alarm History tab).
  2. Note down the model, serial number and software versions (HMI Release, PLC Release) from the Machine Diagnostics > Support page.
  3. Note down the checks already carried out and their results.

Remedy: contact CEMAS Elettra support with the data you have collected: contact details and remote support are available on the Machine Diagnostics > Support page.

Cavities

The Cavity unit indicates where the selected element is located (presence, actuator, vacuum or control):

  • Select position: the tool interface to which it is wired, selected using the buttons next to the diagram (top: head; centre: mirror; bottom: table); appears on machines with a head or a mirror;
  • Select cavity: for multi-cavity tools, the cavities to which it belongs, with a box beneath each cavity.

The selected interface determines the pins suggested in the Input pop-up and, for actuators, the available valves. This unit does not appear on machines without a head or mirror when using a single-cavity tool, nor for actuators in mirror mode.

Availability: Select position only on machines with a head or mirror (IR, HP, laser, 911MK2-IR, 912-IR and 918MK2-IR). Tooling option: Select Cavity appears with multi-cavity tools (Tool Settings > Configuration, Cavity Configuration tab).

Appearance: a row in the right-hand panel with the title in white capital letters on the left; in the centre, a schematic diagram of the head, mirror and table with the selected part highlighted in yellow and three selection buttons; on the right, diagrams of the cavities with checkboxes.

Cavities

Position: Equipment Settings > Actuators and Presences page, Presences tab, Actuators, Voids, Input Commands and Output Commands, second row of the right-hand panel.

Blow-through timeout

The Blow-off time field in the Timings unit is the maximum time, in seconds (s), within which the part must be ejected from the mould cavity during the blow-off cycle; if this time is exceeded, an alarm is triggered.

Availability: machine option: appears if the machine has at least one vacuum (Machine Settings > General Settings > Components, Vacuums).

Appearance: white field with a green border followed by s.

Times

Position: Equipment Settings > Actuators and Presences page, Vacuums tab, Times unit, first field.

A breath of time

The Blow time field in the Times unit is the duration, in seconds (s), of the blow that the welding machine performs after each part is released.

Availability: machine option: appears if the machine has at least one vacuum (Machine Settings > General Settings > Components, Vacuums).

Appearance: white field with a green border followed by s.

Position: Equipment Settings > Actuators and Presences page, Vacuum tab, Times unit, second field.

Empty timeout

The Vacuum Timeout field in the Timers unit is the maximum time, in seconds (s), within which the vacuum must be achieved; if this time is exceeded, an alarm is triggered.

Availability: machine option: appears if the machine has at least one vacuum (Machine Settings > General Settings > Components, Vacuums).

Appearance: white field with a green border followed by s.

Position: Equipment Settings > Actuators and Presences page, Vacuum tab, Times unit, third field.

Cavities

With multi-cavity moulds, the boxes beneath the cavity diagrams indicate which cavities the element belongs to: on the Infrared Parameters page, the selected zone of the mirror, which heats the parts in the chosen cavities; on the Actuators and Presences page, the selected presence, actuator, vacuum or control. The boxes are active only when the zone is enabled. For mirror zones, during the cycle, Standby power is supplied to all enabled zones, whilst Full power 1 and Full power 2 are supplied only to the zones of the cavity currently being processed and to those assigned to both cavities; manual tests activate the zones regardless of the cavity.

Availability: tooling option: appears with multi-cavity tools (Tooling Settings > Configuration, Cavity Configuration tab).

Appearance: yellow drawings of the cavities side by side, each with a white square box underneath.

Cavities

Position: Tool Settings > Infrared Parameters page, central row, Cavities unit; Tool Settings > Actuators and Presences page, Cavities unit.

Commands

Advanced view

The Commands button opens a pop-up window that associates the tool’s output commands – configured in the Output Commands tab – with the element. In the Outputs unit, you can use a drop-down menu to select which output to activate: for presence signals, choose between Present and Absent; for actuators and vacuums, choose between the two positions. Visible only in the advanced view. The output is not a pulse: it remains active whilst the selected condition is present, with the On and Off delays set in the output command.

Availability: machine option: this appears in the Vacuum tab if the machine has at least one vacuum (Machine settings > General settings > Components, Vacuum).

Appearance: a round green button with a black gear icon next to the text COMMANDS.

Commands

Commands Pop-up

Position: Equipment Settings > Actuators and Presences page, Presences, Actuators and Vacuums tabs, right-hand panel.

Delay

The Delay unit on the Vacuum tab has two fields, On and Off, in seconds (s): the time for which the vacuum signal must remain on (On) or off (Off) before it is considered stable. The delay filters the vacuum switch signal; it does not control the valve; the time-outs in the Times unit use the unfiltered signal. Visible only in the advanced view.

Availability: machine option configured by CEMAS: appears if the machine has at least one vacuum present (Vacuums).

Appearance: row in the right-hand panel with the title in white capital letters on the left, with two white fields with a green border followed by s.

Position: Equipment Settings > Actuators and Presences page, Vacuum tab, last row of the right-hand panel.

Input commands

Advanced view

The Input Commands tab configures the tools’ input signals – such as buttons or pedals fitted to the tools – to be used in the cycle. On the left is the list of commands; on the right are the parameters for the selected command. Visible only in advanced view.

On laser machines, the same help is displayed on the Bundles tab: see the linked entry.

Input Commands

Appearance: tab labelled Input commands with an icon of an arrow entering a circle.

Position: Equipment settings > Actuators and presences page, top tab after Blanks.

List of commands

The left-hand side of the Input commands and Output commands tabs lists the configured commands, showing their name and type icon. Tap a row to view its parameters on the right; the − button deletes the command, whilst the + button at the bottom of the list adds a new one to one of the free slots.

Appearance: rows with a round green button bearing the − symbol and the name; at the bottom, a round green button bearing the + symbol.

List of commands

Position: Equipment Settings > Actuators and Presences page, Input Commands tab and Output Commands tab, left-hand side.

Input command configuration

The right-hand side of the Input Commands tab displays the parameters for the selected command, arranged in rows: name (Input Tool Command with the number), Cavity, Signal and Type. If no commands are selected, the message Select or add an input command appears.

The Type unit uses a drop-down menu to select the type of command, which is also indicated by the icon next to it: Generic, Button, Footswitch, Robot or Traceability. The type is used solely to select the icon and does not alter the command’s function within the cycle. The command is used in the cycle stages either as a condition (the cycle waits for it to be active or inactive) or as an external command for an actuator or a vacuum, separately for each alternative cycle.

Type

Position: Equipment Settings > Actuators and Presence page, Input Commands tab, right-hand side.

Input Tools Command

The Input Tool Command field, which contains a number, holds the command’s identification name, as displayed in the list and on the pages where the command is associated, for example Tool Settings > Cycle Settings.

Appearance: white text field with a green border.

Input Tool Command

Position: Equipment Settings > Actuators and Presences page, Input Commands tab, first row of the right-hand panel.

Cavities

The Cavity unit indicates where the selected element is located (presence, actuator, vacuum or control):

  • Select position: the tool interface to which it is wired, selected using the buttons next to the diagram (top: head; centre: mirror; bottom: table); appears on machines with a head or a mirror;
  • Select cavity: for multi-cavity tools, the cavities to which it belongs, with a box beneath each cavity.

The selected interface determines the pins suggested in the Input pop-up and, for actuators, the available valves. This unit does not appear on machines without a head or mirror when using a single-cavity tool, nor for actuators in mirror mode.

Availability: Select position only on machines with a head or mirror (IR, HP, laser, 911MK2-IR, 912-IR and 918MK2-IR). Tooling option: Select Cavity appears with multi-cavity tools (Tool Settings > Configuration, Cavity Configuration tab).

Appearance: a row in the right-hand panel with the title in white capital letters on the left; in the centre, a schematic diagram of the head, mirror and table with the selected part highlighted in yellow and three selection buttons; on the right, diagrams of the cavities with checkboxes.

Cavities

Position: Equipment Settings > Actuators and Presences page, Presences tab, Actuators, Voids, Input Commands and Output Commands, second row of the right-hand panel.

Signal

The Signal unit indicates where the input command comes from. The Mode menu allows you to select:

  • Plug: the signal comes from a pin on the tool’s plug; this must be assigned using the Input button;
  • Smart Tool: the signal comes from the smart tool and is selected from the Signal menu that appears in place of the button.

Appearance: the Mode drop-down menu and, on the right, the Input button or the Signal menu.

Signal

Position: Machine Settings > Actuators and Presences page, Input Commands tab, right-hand panel, under Cavities.

Input

The Input button opens the input assignment pop-up, with the element’s name in the title. The pop-up displays the pins of the selected interface’s connector in the Sockets unit: tap the pin to which the sensor is connected to assign it. Below is the pin colour key:

  • Free: white;
  • Occupied: black, already assigned to another element;
  • Unusable: dark grey;
  • Selected: orange, the pin assigned to the element;
  • Active input: green indicator next to the pin where signals are present.

For actuators, the pop-up has two tabs, Rest and Work, one per sensor. For input controls, the button only appears in Plug mode. Close the pop-up using the down arrow.

Appearance: a round green button with a black gear icon next to the word INPUT.

Input

Input Pop-up

Position: Equipment Settings > Actuators and Presences page, Presences, Actuators and Input Commands tabs, right-hand panel.

Cavities

With multi-cavity moulds, the boxes beneath the cavity diagrams indicate which cavities the element belongs to: on the Infrared Parameters page, the selected zone of the mirror, which heats the parts in the chosen cavities; on the Actuators and Presences page, the selected presence, actuator, vacuum or control. The boxes are active only when the zone is enabled. For mirror zones, during the cycle, Standby power is supplied to all enabled zones, whilst Full power 1 and Full power 2 are supplied only to the zones of the cavity currently being processed and to those assigned to both cavities; manual tests activate the zones regardless of the cavity.

Availability: tooling option: appears with multi-cavity tools (Tooling Settings > Configuration, Cavity Configuration tab).

Appearance: yellow drawings of the cavities side by side, each with a white square box underneath.

Cavities

Position: Tool Settings > Infrared Parameters page, central row, Cavities unit; Tool Settings > Actuators and Presences page, Cavities unit.

Type

The Type unit uses a drop-down menu to select the type of input command: Generic, Button, Footswitch, Robot or Traceability. The type only changes the icon displayed next to the menu and in the list of commands, so that they can be recognised at a glance; it does not change how the command is used within the cycle.

Appearance: a row in the right-hand panel with the title in white capital letters on the left, the drop-down menu and, on the right, the icon for the selected type.

Position: Equipment Settings > Actuators and Presences page, Input Commands tab, bottom row of the right-hand panel.

Input

The Inputs unit associates the input commands from the tools that control it externally – for example, a clamp button on the tool that confirms the action – with an actuator or a vacuum. For an actuator, there are the Idle and Operate menus; for a vacuum, Off and On: in each, you select the input command that moves the element to that position; Select signal leaves the position without an external command. Below the menus, a note outlines the typical use, for example the CLAMP button.

The available input commands are those configured in the Input Commands tab on the Equipment Settings > Actuators and Presences page, visible in the advanced view.

Availability: machine option configured by CEMAS: Alternative automatic cycle; when this option is enabled, the selection applies to the alternative cycle from which the pop-up was opened; when disabled, it applies to the single automatic cycle.

Appearance: unit with the title INPUTS and two side-by-side drop-down menus, followed by a small note.

Position: Equipment Settings > Cycle Settings page, at the bottom of the actuator or vacuum pop-up opened from the phase table.

Output commands

Advanced view

The Output Commands tab configures the output signals to the tools, such as indicator lights or commands for devices fitted to the tools, triggered by presences, actuators or vacuums. On the left is the list of commands; on the right are the parameters for the selected command. Visible only in advanced view.

Output Commands

Appearance: a tab labelled Output commands with an icon of an arrow emerging from a circle.

Position: Equipment settings > Actuators and Presences page, topmost tab.

List of commands

The left-hand side of the Input commands and Output commands tabs lists the configured commands, showing their name and type icon. Tap a row to view its parameters on the right; the − button deletes the command, whilst the + button at the bottom of the list adds a new one to one of the free slots.

Appearance: rows with a round green button bearing the − symbol and the name; at the bottom, a round green button bearing the + symbol.

List of commands

Position: Equipment Settings > Actuators and Presences page, Input Commands tab and Output Commands tab, left-hand side.

Output command configuration

The right-hand side of the Output Commands tab displays the parameters for the selected command, arranged in rows: name (Output Tool Command followed by a number), Cavity, Signal and Delay. If no commands are selected, the message Select or add an output command appears.

The Delay unit has two fields, On and Off, in seconds (s): the delay with which the output switches on and off relative to the command. The output switches on On seconds after the command and remains on for Off seconds after the command has ceased. The output is only activated during the cycle steps in which it is programmed.

Delay

Position: Equipment Settings > Actuators and Presences page, Output Commands tab, right-hand side.

Output tool control

The Output Equipment Command field, which contains a number, holds the command’s identification name, displayed in the list and in the Commands pop-ups for presences, actuators and voids, where the command is associated.

Appearance: white text field with a green border.

Output Equipment Command

Position: Equipment Settings > Actuators and Presences page, Output Commands tab, first row of the right-hand panel.

Cavities

The Cavity unit indicates where the selected element is located (presence, actuator, vacuum or control):

  • Select position: the tool interface to which it is wired, selected using the buttons next to the diagram (top: head; centre: mirror; bottom: table); appears on machines with a head or a mirror;
  • Select cavity: for multi-cavity tools, the cavities to which it belongs, with a box beneath each cavity.

The selected interface determines the pins suggested in the Input pop-up and, for actuators, the available valves. This unit does not appear on machines without a head or mirror when using a single-cavity tool, nor for actuators in mirror mode.

Availability: Select position only on machines with a head or mirror (IR, HP, laser, 911MK2-IR, 912-IR and 918MK2-IR). Tooling option: Select Cavity appears with multi-cavity tools (Tool Settings > Configuration, Cavity Configuration tab).

Appearance: a row in the right-hand panel with the title in white capital letters on the left; in the centre, a schematic diagram of the head, mirror and table with the selected part highlighted in yellow and three selection buttons; on the right, diagrams of the cavities with checkboxes.

Cavities

Position: Equipment Settings > Actuators and Presences page, Presences tab, Actuators, Voids, Input Commands and Output Commands, second row of the right-hand panel.

Signal

The Signal unit uses a drop-down menu to select the signal on the smart tool to which the output command is sent; until a selection is made, the menu displays Select signal.

Appearance: drop-down menu in the centre of the row.

Signal

Position: Equipment Settings > Actuators and Presences page, Output Commands tab, right-hand panel, under Cavities.

Delay

The Delay unit on the Output Commands tab has two fields, On and Off, in seconds (s): the output switches On seconds after the condition that controls it (presence, actuator or vacuum to which it is associated) becomes true, and remains on for Off seconds after the condition ceases. With 0 s, the output follows the condition immediately.

Appearance: row in the right-hand panel with the title in white capital letters on the left, with two white fields with a green border followed by s.

Position: Equipment Settings > Actuators and Presences page, Output Commands tab, last row of the right-hand panel.

Cavities

With multi-cavity moulds, the boxes beneath the cavity diagrams indicate which cavities the element belongs to: on the Infrared Parameters page, the selected zone of the mirror, which heats the parts in the chosen cavities; on the Actuators and Presences page, the selected presence, actuator, vacuum or control. The boxes are active only when the zone is enabled. For mirror zones, during the cycle, Standby power is supplied to all enabled zones, whilst Full power 1 and Full power 2 are supplied only to the zones of the cavity currently being processed and to those assigned to both cavities; manual tests activate the zones regardless of the cavity.

Availability: tooling option: appears with multi-cavity tools (Tooling Settings > Configuration, Cavity Configuration tab).

Appearance: yellow drawings of the cavities side by side, each with a white square box underneath.

Cavities

Position: Tool Settings > Infrared Parameters page, central row, Cavities unit; Tool Settings > Actuators and Presences page, Cavities unit.

Undercut

Advanced view

The UNDERCUT card, visible only in ADVANCED CONFIGURATION mode, if the undercut function is activated in the TOOL SETTINGS/CONFIGURATION, allows you to manage the elements for overcoming the undercut when loading the piece to be welded in the machine. An undercut occurs when the shape of the part to be welded is such that it cannot be split and extracted from the fixture cavity without damaging the part itself, i.e. when the part has angles of less than 90°, which effectively make the part indivisible from the fixture cavity. You can select:

  • rest, if the undercut system is to be at rest during the loading of the workpiece;
  • work, if the undercut system is to be at work during the workpiece loading phase.

Positions

The Positions page sets the coordinates reached by the machine axes (table, head, mirror, sliding table) during the machine cycle’s automatic movements with the tools fitted. The coordinates are in millimetres (mm) and are saved with the tools configuration. The fields cannot be edited whilst the machine is in automatic mode.

The tabs depend on the machine’s technology and configuration:

  • Table: machines with vibration and laser;
  • Positions: IR and HP machines, showing the table, head and mirror positions together;
  • Translating table: machines with a translating table;
  • Mirrors: vibration machines with two IR mirrors (912-IR);
  • Mirror and Cams: vibration machines with cam-operated IR mirrors (911MK2-IR, 918MK2-IR), depending on the type of mirror fitted to the tools.

The meaning of the dimensions depends on the machine’s technology: see the related entries.

Positions

Position: Tool Settings > Positions menu.

Table

The Table tab sets the table coordinates for the cycle’s automatic movements. On the left is the list of coordinates: Upper limit, Workpiece contact, Workpiece release, Centering and Piece taking (depending on the piece taking grip), Intermediate Translation (hydraulic vibration with a translating table in an undercut position), Undercut (piece taking in an undercut position), Preheating (with the IR mirror), Out of Envelope and Loading; below, Automatic table speed and Deceleration. In the centre is a schematic diagram of the machine.

On the right are the current table height and the buttons to move it manually: once the table has been moved to the desired position, the height is recorded using the button next to the field. At the bottom right is the Constraints button. The fields cannot be edited whilst the machine is in automatic mode.

Availability: only on vibration and laser machines.

Position: Equipment Settings > Positions page, first tab.

Take up position

The button next to a dimension field copies the current position of the axis into that field: move the axis to the desired position using the manual movement buttons, then tap the button to record it as the dimension for the automatic movement. The button does not appear during the tool configuration wizard.

Availability: only on machines with vibration and laser.

Appearance: a round green button with a black icon of an arrow entering a tray, to the right of the dimension field.

Capture position

Location: Tool Settings > Positions page, Table and Mirrors tabs, to the right of each position that can be captured.

Upper limit

The maximum height reached by the table when moving upwards, in millimetres (mm), for example when there are no workpieces to be welded in the tool. The value is entered in the field, in millimetres (mm), or is acquired using the button next to the field after moving the axis to the desired position.

Availability: only on vibration and laser machines.

Position: Jig Settings > Positions page, Table tab, first entry in the list.

Part contact

The height on the table, in millimetres (mm), at which the parts to be welded come into contact. The value is entered in the field, in millimetres (mm), or is acquired using the button next to the field after moving the axis to the desired position. This is the end point of the upward movement: within the contact tolerance, the table switches to force control based on the welding force, and from there the force is regulated by force. The height is limited between the loading position and the Upper limit. If, whilst in force control, the table is more than 10 mm above or more than 30 mm below the height, the machine signals an incorrect contact position alarm. With the cam follower, the height is determined by the cam and cannot be adjusted.

Availability: only on vibration and laser machines. Equipment option: does not appear with Equipment type With cam mirror (Equipment settings > Configuration, Equipment type tab).

Position: Equipment Settings > Positions page, Table tab, under Upper Limit.

Piece taking

The height reached by the table to enable the machine to pick up the top workpiece from the upper tool, without operator intervention, in millimetres (mm). The value is entered in the field, in millimetres (mm), or is acquired using the button next to the field after moving the axis to the desired position. It appears only when the piece taking tool is active (simple or with centering).

Availability: only on machines with vibration and laser. Tool option: appears with Simple or Simple with centering piece taking (Tool Settings > Configuration, Piece Taking tab).

Position: Tool Settings > Positions page, Table tab, in the list of dimensions under Part Removal.

External dimensions

The height reached by the table to allow other movements, such as the mirror, to pass freely during the cycle, in millimetres (mm). The value is entered in the field, in millimetres (mm), or is acquired using the button next to the field after moving the axis to the desired position. It appears when the IR mirror or the piece taking gripper is active.

With the Simple with centering piece taking gripper, the same clearance appears under the name Centering, but the clearance dimension remains: the table stops for centering at the Piece taking gripper clearance, then at this clearance and finally at Piece taking contact.

Availability: only on machines with vibration and laser. Tooling option: appears when Workpiece taking is active (Tooling settings > Configuration, Workpiece taking tab) or with mirror tools (Tooling type tab).

Position: Machine Settings > Positions page, Table tab, in the list of dimensions above Load.

Part cutting

The height reached by the table to detach the welded piece before the rapid descent, in millimetres (mm). The value is entered in the field, in millimetres (mm), or is acquired using the button next to the field after moving the axis to the desired position.

Availability: only on vibration and laser machines.

Position: Equipment Settings > Positions page, Table tab, under Workpiece Contact.

Load

The height at which the table stops for loading and unloading workpieces, in millimetres (mm). The value can be entered in the field, in millimetres (mm), or acquired using the button next to the field after moving the axis to the desired position.

Availability: only on vibration and laser machines.

Position: Equipment Settings > Positions page, Table tab, last dimension in the list.

Automatic table speed

1.4.14

Table speed during automatic movements between positions on the table, as a percentage (%) of the maximum speed. This also affects the point at which deceleration begins: see Deceleration.

Availability: on vibration and laser machines only.

Position: Machine Settings > Positions page, Table tab, below the list of positions.

Slowdown

Distance, in millimetres (mm), prior to the arrival position at which the table begins to slow down following the rapid ascent, before attempting to make contact between the workpieces. The actual distance is adjusted according to the Automatic table speed:

start of deceleration = arrival position − (deceleration × set speed)

For example, with a deceleration of 150 mm, the table decelerates by 150 mm before the arrival position at 100% speed, and by 30 mm before at 20% speed.

Deceleration example

Speed profile

Availability: only on vibration and laser machines.

Position: Machine settings > Positions page, Table tab, under Automatic table speed.

Restrictions

The Constraints button opens the axis’s Safety Constraints pop-up, which has three tabs: Manual, Automatic and Tool Change. In each tab, for each movement (for the table: Up and Down; for the mirror: Work and Rest), you specify the state in which the actuators and tool presences must be for the movement to be permitted, in order to avoid collisions:

  • actuators: Not specified, Rest or Work;
  • sensors: Not specified, Presence or Absence.

Close the pop-up using the down arrow. The same pop-up can be opened using the cog-shaped buttons next to the axis names in the Positions tab for IR and HP machines.

If a constraint is not met, movement stops without triggering an alarm; in automatic mode, the cycle waits until the cycle time limit (180 s) is reached or the maximum Cycle Time alarm is triggered. The axis alarm is triggered only if a movement that has started fails to reach the position (after 3 s on electric machines, 6 s on hydraulic ones). Positions outside their limits do not trigger alarms: they are automatically limited.

Availability: only on vibration and laser machines.

Appearance: a round green button with a black gear icon and the text CONSTRAINTS; in the pop-up, rows with round selection buttons.

Safety constraints

Position: Equipment Settings > Positions page, Table tab, bottom right.

Intermediate translation

Option

The Intermediate Translation height of the table is the position, in millimetres (mm), to which the table moves before the sliding plate moves, with the sliding plate in Undercut mode: the table stops at this height before the sliding plate moves into the welding position and, after cooling, before the sliding plate returns to the insertion position. The value is entered in the field, in millimetres (mm), or acquired using the button next to the field after moving the axis to the desired position.

Availability: only on hydraulic vibration machines (901-ST, 901-HL, 902-HL, 911, 918, 950-ST, 950-HL, 999-HL, 999-XT). Machine option configured by CEMAS: appears with the Sliding table component. Tool option: appears with the Sliding table Undercut (Tool settings > Configuration, Sliding table tab).

Appearance: a row showing the name of the height, a white field with a green border followed by mm, a round green indicator light when the axis is at that height, and a round green acquisition button.

Position: Machine Settings > Positions page, Table tab, in the list of dimensions after Piece Taking.

Animation

The schematic diagram of the machine shows the position of the axes in a simplified manner and helps to identify the dimensions set in the tab.

Availability: only on vibration and laser machines.

Position: Tool Settings > Positions page, Table and Mirrors tabs, in the centre.

Movement

The arrow buttons move the table up or down. The table only moves whilst the button is held down and stops at the height indicated above (top button) or below (bottom button), in millimetres (mm).

The target heights depend on the page and the machine’s status:

  • in Tool Change, these are the tool change heights;
  • in Manual Movements, with no tool loaded, these are the maximum stroke and minimum opening of the table; with the tool loaded, they are the workpiece contact height (or preheating height, with the mirror in position) and the loading height.

On hydraulic machines with the sliding table in undercut mode, the top button moves the table to the insertion height, indicated to the right of the buttons, and a third button appears which moves it to the piece taking height.

Appearance: a black vertical bar with two round green buttons featuring arrows; the button has a green outline when the table is at the height indicated beside it.

Movement

Position: Machine Diagnostics > Manual Movements page, Machine > Axes > Table tab, to the right of the drawing; Tool Change > Tool Change page, Manual > Axes > Table tab.

Cycle settings

The Cycle Settings page specifies, for each stage of the automatic cycle, what the equipment components do: actuators, vacuums, presences and, in the advanced view, the input and output controls for the machine and the tool.

The page is a table:

  • columns: the cycle stages, in the order in which they are executed, each with a name and an image. A column with multiple dots beneath the image represents a unit of stages: tap it to expand it into individual stages; tap a stage to collapse the unit. Stages not used by the tool configuration are hidden;
  • rows: the units Actuators, Vacuum, Presences and, in the advanced view, Input commands, Output commands, Equipment input commands and Equipment output commands. Each unit expands into one row per component and has its own legend next to it; if the tool has no components of that type, the message No actuators available, No vacuums available, No presence sensors available or No commands available appears.

There is a tab for each enabled automatic cycle: Operator and, if alternative automatic cycles are enabled, a tab for each of them. If there are no alternative cycles, the tab bar does not appear.

Each cell indicates what a component does during a phase. Tap the cell to move to the next value, tap it twice to return to the previous one:

  • actuator: Not used, Work, Rest;
  • vacuum: Not used, Vacuum, Off (the machine performs the blowing cycle);
  • presence: Not used, Presence (the part must be present), Absence (the part must not be present);
  • controls: Not used, On, Off.

Holding down an actuator cell opens a pop-up with Delay (in seconds, s, before movement), Action with the Check box, Pulse duration (s), the Skip external command box and the Reset all button; for a vacuum, the pop-up only contains Action, Verification and Skip external command. If Verification is deselected, the action becomes Uncontrolled action: the machine issues the command but does not wait for it to be completed.

At each stage, the machine applies the column and waits for each programmed component to be in the specified state before moving on to the next stage; if the cycle halts at a stage, check the components in its column. With Not used, the actuator receives no commands and remains where it is. The programming applies only in automatic cycle mode.

The available stages depend on the machine’s technology: see the related entries.

In automatic cycle mode, the column for the current stage is highlighted and the page cannot be edited. The page is only available once the tool parameters have been loaded.

Appearance: a table with, in the first cell, the text Welding cycle stages with a right-pointing arrow and Tool components with a down-pointing arrow; at the top, the stage columns with the name and image; on the left, the unit names in capital letters (ACTUATORS, VACUMS, PRESENCES) followed by the KEY: a coloured square for each value (Presence in green, Absence in red) and the icons for Delay, Pulse, Uncontrolled action and external commands, which also appear in the cells.

Position: Tool Settings > Cycle Settings menu.

Stages of the cycle

The top row of the Cycle Settings page lists the stages of the automatic cycle, from left to right in the order in which they are carried out: each column contains the name of the stage and an image of the tool used in that stage. These are the same stages, with the same names and images, that the CONTROL PAGE displays during the cycle.

Some stages are grouped together (for example, Welding or End of Cycle): the unit occupies a single column, displaying the name and image of one of its stages and a row of dots, one for each stage. Tapping the unit expands the column to show the individual stages.

Phases not used by the tool or machine configuration (for example, when the piece taking gripper is disabled or the sliding table is absent) are hidden and the machine skips them. Each stage has a fixed number, which does not change when other stages are hidden: the tables of related entries show this in the No. column, which is useful for identifying the stage even when the numbering of the visible columns has gaps.

In automatic cycle mode, the column for the current stage is highlighted with a white border; for a unit, the unit’s column is highlighted.

The meaning of the stages depends on the machine’s technology: see the related entries.

Appearance: the table’s header row, with the phase name above a colour image and a row of dots below the image.

Position: the Equipment Settings > Cycle Settings page, top row of the table, to the right of the Welding cycle phases cell.

Stages of the cycle – Vibration

On vibration machines without infrared heating, the cycle comprises 28 stages, from 0 to 27. The piece taking stages depend on the Piece Taking tab, whilst those for the sliding table depend on the Sliding Table tab (Equipment Settings > Configuration), which is only available on machines with a sliding table (950-ST, 950-HL, 999-HL, 999-XT).

Image No. Step What the machine does When it is executed
Anti-repeat check 0 Anti-repeat check Checks for presences of parts to prevent the cycle from being repeated on the same parts. Always; with the moving table, the image shows the table
Part loading 1 Part loading No movement: the operator loads the parts; the machine waits for the conditions programmed in the column. Always; with the moving table, the image shows the table
Model selection 2 Model selection Identifies the model (left or right cavity) based on presences or manual selection and loads the parameters for that side. With multi-cavity tools (Cavity configuration tab in Tool settings > Configuration)
Cycle start 3 Cycle start Waits for the cycle start button to be pressed, with the operator’s safety devices in place. Resets the result of the last cycle. Always
Workpiece clamp 4 Workpiece clamp Clamps the workpieces using the clamps and vacuums programmed in the column; resets the welding time. Always
Sliding table positioning 5 Sliding table positioning Moves the sliding table to the welding position (Simple) or the insertion position (Undercut). If the machine has a sliding table and the tools use it (Sliding table card: Simple or Undercut)
Gate closure 6 Gate closure Closes the gates and waits for them to be closed; a missing or disabled gate is not waited for; a gate that moves with the table is checked for contact with the workpieces. Always
Positioning the piece taking gripper slide 7 Positioning the piece taking gripper slide (Piece taking gripper unit) Moves the piece taking gripper slide into position. With the Simple Piece taking gripper (Piece taking gripper card)
Positioning the table in the piece taking grip 8 Positioning the table in the piece taking grip (Piece taking grip unit) Moves the table to the piece taking grip height. With the Simple or Simple with centering Piece taking grip
Piece taking grip 9 Piece taking grip (Piece taking grip unit) Holds the table in the grip; actuators, vacuum points and piece taking centering are controlled from the column. With Piece taking grip active
Out-of-the-way positioning 10 Out-of-the-way positioning (Piece taking unit group) Moves the table to the out-of-the-way position. With the Piece taking unit active; with Simple with centering, the image changes
Positioning the piece taking gripper carriage in the rest position 11 Positioning the piece taking gripper carriage in the rest position (Piece taking gripper unit) Waits for the piece taking gripper carriage to reach the rest position (with Simple with centering, the carriage is not controlled). With Piece taking gripper active; with Simple with centering the image changes
Positioning the table in the insertion position 12 Positioning the table in the insertion position Moves the table to the insertion position. With the Sliding table set to Undercut
Positioning the sliding table in the welding position 13 Positioning the sliding table in the welding position Moves the sliding table to the welding position, without waiting for the column. With the Sliding table Undercut; with Simple, the column appears, but the table moves to the welding position as early as stage 5
Positioning the table in contact with the workpieces 14 Positioning the table in contact with the workpieces Moves the table into contact with the workpieces and waits for contact, clamping and the gates to close; then initiates welding. An alarm is triggered if contact is maintained for 5 seconds without clamping. Always; the image changes when the piece is taken or when load is applied to the head
Stabilisation 15 Stabilisation (Welding unit) Waits for the transducers to stabilise, with the table stationary. Always
Welding 16 Welding (Welding unit) Performs any adjustment and the force phases; the head vibrates. Ends when welding is complete or if a reject occurs. Always
Cooling 17 Cooling (Welding unit) Keeps the workpieces under pressure; the welding machine determines the outcome: pass or reject. Always
Positioning the table in the insertion position 18 Positioning the table in the insertion position (Positioning the sliding table in the insertion position unit) Moves the table into the insertion position. With the Sliding table Undercut
Positioning the sliding table in the insertion position 19 Positioning the sliding table in the insertion position (Positioning the sliding table in the insertion position unit) Moves the sliding table to the insertion position; the cycle then proceeds to phase 21. With the Sliding table Undercut
Part ejection 20 Part ejection Moves the table towards the ejection point, without waiting for the column. Without a transfer table or with the *Simple transfer table; with Unloading from the head*, the image changes
Positioning the table in the loading position 21 Positioning the table in the loading position Moves the table to the loading position. Always; the image changes with Head unloading and with the Undercut sliding table
Marking 22 Marking (End of cycle unit) Controls the marking actuators (good part or scrap piece). If an action is required for a reject, it waits for confirmation of the reject on the HMI. Always
Opening gates 23 Opening gates (End of cycle unit) Opens the gates and waits for them to open. Always
Positioning the sliding table in the loading position 24 Positioning the sliding table in the loading position (End of cycle unit) Moves the sliding table to the loading position, without waiting for the column. If the machine has a sliding table and the tool uses it
Release workpieces 25 Release workpieces (End of cycle unit) Releases the clamps programmed in the column. Always
Unloading workpieces 26 Unloading workpieces (End of cycle unit) Waits for the workpiece to be removed (interruption of the light curtains, if present); then, if required by User feedback, the operator’s confirmation. Always; with the moving table, the image shows the table
End of cycle 27 End of cycle (End of cycle unit) Ends the cycle, records it in the history and returns to phase 0. Always

Skipped and pending stages

  • Single-cavity tooling: stage 2 is hidden and the machine skips it immediately.
  • Piece taking Disabled: stages 7–11 skipped; Simple with centering: stage 7 skipped.
  • Machine without a sliding table, or table not used by the tools: stages 5, 12, 13, 18, 19 and 24 skipped. Sliding table Simple: steps 12, 18 and 19 are skipped; Undercut: step 20 is skipped.
  • Gates absent or excluded: steps 6 and 23 do not control them and do not wait for them.
  • Dry run cycle (card Dry run cycle in Machine Diagnostics > Machine Test): model selection has been completed; the cycle restarts automatically after the set delay and does not wait for rejection confirmation, the unloading barriers or the operator’s decision. With Skip welding, the weldings are carried out with all movements, but the head does not vibrate.

In each phase, in addition to the conditions described, the cycle waits for all components programmed in the column to be in the indicated state; phases 13, 20 and 24 apply the column without waiting for it.

Automatic cycles

The tabs at the top of the page – one for each enabled automatic cycle – allow you to select which cycle to programme: Operator, the main cycle, and the alternative automatic cycles, with the name shown in the Alternative Automatic Cycle pop-up. Each cycle has its own phase schedule and external commands; the cycle to be run by the machine is selected on the Equipment Settings > Configuration page, under the Alternative Automatic Cycle tab.

Availability: machine option configured by CEMAS: Alternative Automatic Cycle. Tool option: the tabs appear when the function and at least one alternative cycle are enabled (Tool Settings > Configuration, Alternative Automatic Cycle tab); without alternative cycles, the tab bar does not appear.

Automatic cycles

Appearance: tabs displaying the cycle name, with the selected tab highlighted.

Position: Tool settings > Cycle settings page, tab bar at the top.

Delay

The Delay field is the time, in seconds (s), to two decimal places, that the machine waits at the start of the phase before controlling the actuator to the position programmed in the cell. The Reset button below the field resets the delay to zero.

The pop-up has the name of the actuator in the title and, below that, the name of the phase.

Appearance: a box with the title in white capital letters and, on the right, a white icon (a stopwatch), a white field with a green border followed by s and the Reset button.

Position: Equipment Settings > Cycle Settings page; a pop-up that opens when you hold down an actuator cell, in the top-left box.

Action

The Action box displays the command programmed in the cell for the phase (for an actuator: Work, Rest or Not used; for a vacuum: Vacuum, Off or Not used) and features the Verification box:

  • with Verification enabled, the machine controls the actuator or vacuum and waits for it to reach the programmed state before moving on to the next phase;
  • when Verification is disabled, the action becomes Uncontrolled action: the machine controls it but does not wait for it to be completed, and the cell signals this with a dedicated icon.

The Reset button returns the cell to Not in use, with Verification enabled and Skip external command disabled.

Appearance: a box with the title in white capital letters and, on the right, a white icon (a play arrow), the name of the action, the Verify tick box and the Reset button.

Position: Equipment Settings > Cycle Settings page; a pop-up that opens when you hold down a cell for an actuator or vacuum; the Action box at the top.

Pulse duration

The Pulse Duration field is the time, in seconds (s), to two decimal places, for which the actuator is controlled to the programmed position; when set to zero, the command remains active. The Reset button resets the duration to zero.

Appearance: a box with the title in white capital letters and, on the right, a white icon (a pulse), a white field with a green border followed by s and the Reset button.

Position: Equipment Settings > Cycle Settings page, pop-up that opens when you hold down an actuator cell, top-right box.

Skip external command

Ticking the Skip external command box causes the external command associated with the actuator or vacuum to be ignored at this stage: when this box is ticked, the component is not controlled by the external input command (for example, a button or foot pedal on the tool) at this stage, but only by the cell’s programming. External commands are assigned in the Inputs box of the same pop-up window, separately for each automatic cycle.

Availability: appears only if at least one external command is assigned to the actuator or vacuum in the current cycle.

Appearance: a square box labelled Skip external command, with a tick when active.

Position: Tool Settings > Cycle Settings page, a pop-up that opens when you hold down the cell for an actuator or vacuum, next to the Inputs box.

Restore all

The Reset All button restores all cell settings to their default values: the Not used action with Verification enabled, Skip external command disabled and, for actuators, the delay and pulse duration set to zero. It also clears any external commands associated with the component in the current cycle.

Appearance: green button labelled RESET ALL.

Position: Tool Settings > Cycle Settings page; in the pop-up that appears when you hold down an actuator or vacuum cell, at the bottom of the pop-up.

Welding parameters

The Welding Parameters page sets the stages of the welding cycle for the fitted tool: a table with one row per stage and, for each stage, duration or depth, force and the other process parameters. The Welding Limits button at the top opens the workpiece acceptance limits.

With multi-cavity tools, the parameters are divided into the LH+RH, LH and RH tabs, one for each model; with a single cavity, there is only one table (Configuration). Upon opening, the tab for the side in use is selected.

At the bottom of the page, if supported by the machine, a button with a printer icon may appear, which displays a preview of the receipt containing the parameters and prints it, along with the Manual Welding switch: when activated, welding of the displayed side begins by pressing the START CYCLE button.

Manual welding performs only the welding sequence, without the cycle movements: stabilisation, settling, welding phases (with vibration on machines with vibration) and cooling; on IR and HP machines there is no heating and the process proceeds directly to the pushing phases. It can only be started in manual mode, with this page open, the welding machine ready, the side selected and the table already in force control mode, i.e. with the workpieces brought into contact by the operator. Switching off the power switch stops the welding process.

When the machine is in automatic mode, the parameters are only modified if the Automatic parameter change option in the machine’s general settings is enabled. The stages and their content depend on the machine’s technology: see the related entries.

Welding parameters

Two-cavity tool

Position: Tool settings > Welding parameters menu.

LH+RH, LH, RH

With multi-cavity tools, the welding parameters are divided into three tabs, one for each model: LH+RH, for welding cycles where both sides are welded, and LH and RH, for welding cycles involving only one side. Each tab has its own phase table and its own Welding Limits. When the page opens, the tab for the side currently in use in the cycle is selected; switching tabs deactivates Manual Welding.

Availability: tooling option: the tabs appear with multi-cavity tools (Tooling Settings > Configuration, Cavity Configuration card); with a single cavity, there is only one table, with no tabs.

Appearance: tabs labelled LH+RH, LH and RH; on IR and HP machines, the tabs are arranged in a column on the left.

Position: Tool Settings > Welding Parameters page, at the top (on IR and HP machines, on the left).

Stabilisation phase

The stabilisation phase is the first phase of the welding cycle: the workpieces are subjected to the set Force, in kgf, for the set Time, in seconds (s), to stabilise the position transducer readings prior to welding. The Time is counted only whilst the transducer readings are stable and restarts if stability is lost. At the end of the phase, the transducer readings are reset to zero and become the reference for the welding depth; on vibration machines with a cam-driven mirror and preheating, the reset takes place earlier, during the cycle. The dot to the left of the row turns green whilst the phase is in progress on the side shown.

On HP machines, this entry describes the Table and Head rows of the Heating tab: see the related entry.

Availability: does not appear on IR machines (IR9, IR14, IR20).

Position: Equipment Settings > Welding Parameters page, first row of the table.

Time / Altitude

The Time / Depth column contains the value that marks the end of the phase: the time, in seconds (s), for time-controlled phases and for stabilisation, settling and cooling phases; the depth or penetration, in millimetres (mm), for welding phases with the Type set to Relative depth or End-of-phase depth. Position: Equipment Settings > Welding Parameters page, Time / Depth column of the table.

Weather

The time field for a phase, in the Time / Elevation column, is the duration of the phase in seconds (s), to one decimal place, up to 99.9 s. In welding phases, it appears when the Type is Time; in stabilisation, settling and cooling phases, it is always present. If another Type is selected, the time is reset to zero and the depth or penetration field appears in its place.

Availability: Machine option configured by CEMAS: Automatic parameter change; without this option, the values cannot be modified whilst the machine is in automatic mode.

Appearance: white field with a green border followed by s.

Position: Tool Settings > Welding Parameters page, Time / Depth column of the table, in the row for the phase.

Force

The Thrust column shows the force with which the table pushes the workpieces during the operation, in kgf. On IR and HP machines, this column is called Maximum Thrust: see the related entry.

Position: Equipment Settings > Welding Parameters page, Force column of the table.

Settling-in period

OptionAdvanced view

The settling phase, which is optional, follows stabilisation and settles the parts within the tool once they are already in contact. It is activated using the switch next to the icon; switching it on or off resets the values in the row to zero. It features Time, in seconds (s), Force, in kgf, and, on machines with vibration, Amplitude, in millimetres (mm), or, on laser machines, the Laser Source button showing the power of the sources during the phase. During the phase, the table applies the set Force for the set Time and, on vibration machines, the head vibrates at the set Amplitude. With settling active, the transducer zeroing and the Welding Start Position control are repeated at the end of settling and replace those of the stabilisation phase. On IR machines, this phase is not performed. The dot to the left of the line turns green whilst the phase is in progress on the side shown.

The line appears in the advanced view or when settling is active.

Availability: does not appear on HP machines (HP9, HP14, HP20, HP-P125). Tool option: does not appear with the Welding Type set to Preheat Only (Tool Settings > Configuration, Welding Type tab).

Position: Tool Settings > Welding Parameters page, second row of the table.

Time / Altitude

The Time / Depth column contains the value that marks the end of the phase: the time, in seconds (s), for time-controlled phases and for stabilisation, settling and cooling phases; the depth or penetration, in millimetres (mm), for welding phases with the Type set to Relative depth or End-of-phase depth. Position: Equipment Settings > Welding Parameters page, Time / Depth column of the table.

Weather

The time field for a phase, in the Time / Elevation column, is the duration of the phase in seconds (s), to one decimal place, up to 99.9 s. In welding phases, it appears when the Type is Time; in stabilisation, settling and cooling phases, it is always present. If another Type is selected, the time is reset to zero and the depth or penetration field appears in its place.

Availability: Machine option configured by CEMAS: Automatic parameter change; without this option, the values cannot be modified whilst the machine is in automatic mode.

Appearance: white field with a green border followed by s.

Position: Tool Settings > Welding Parameters page, Time / Depth column of the table, in the row for the phase.

Force

The Thrust column shows the force with which the table pushes the workpieces during the operation, in kgf. On IR and HP machines, this column is called Maximum Thrust: see the related entry.

Position: Equipment Settings > Welding Parameters page, Force column of the table.

Amplitude

The Amplitude column shows the amplitude of the vibration in phase, in millimetres (mm). This cannot be changed when the Welding Type is set to Preheating only (on the Equipment Settings > Configuration page).

Availability: on machines with vibration only.

Position: Equipment Settings > Welding Parameters page, last column of the table.

Welding step

The WELDING STEP is a portion of the processing cycle in which welding is actually carried out. It is useful to divide a welding cycle into several steps to improve monitoring of the welding and thus obtain a higher quality of the welding joint. Each welding step can be monitored in different ways, by selecting the type of control to be carried out.

Type

The Type drop-down menu allows you to select how the welding phase ends:

  • Time: after the set time, in seconds (s);
  • Relative depth: when the workpieces have penetrated by the set amount, in millimetres (mm), from the start of this phase (on machines with vibration, only the table is measured; on IR and HP machines, both the table and the head are measured);
  • End-of-phase height: when the table reaches the set absolute position, in millimetres (mm), as measured by the transducers.

The total depth from the start of welding is shown separately as the welding depth. Changing the type resets the value of the previous type to zero.

Type

Position: Equipment Settings > Welding Parameters page, Type column of the table.

Time / Altitude

The Time / Depth column contains the value that marks the end of the phase: the time, in seconds (s), for time-controlled phases and for stabilisation, settling and cooling phases; the depth or penetration, in millimetres (mm), for welding phases with the Type set to Relative depth or End-of-phase depth. Position: Equipment Settings > Welding Parameters page, Time / Depth column of the table.

Weather

The time field for a phase, in the Time / Elevation column, is the duration of the phase in seconds (s), to one decimal place, up to 99.9 s. In welding phases, it appears when the Type is Time; in stabilisation, settling and cooling phases, it is always present. If another Type is selected, the time is reset to zero and the depth or penetration field appears in its place.

Availability: Machine option configured by CEMAS: Automatic parameter change; without this option, the values cannot be modified whilst the machine is in automatic mode.

Appearance: white field with a green border followed by s.

Position: Tool Settings > Welding Parameters page, Time / Depth column of the table, in the row for the phase.

Force

The Thrust column shows the force with which the table pushes the workpieces during the operation, in kgf. On IR and HP machines, this column is called Maximum Thrust: see the related entry.

Position: Equipment Settings > Welding Parameters page, Force column of the table.

Depth

The ‘Depth’ field for a welding phase, in the Time / Co-ordinate column, appears when the Type of the phase is Relative depth or End-of-phase co-ordinate, in millimetres (mm), to two decimal places:

  • with Relative Depth: by how much the workpieces must be sunk from the start of the phase;
  • with End-of-Phase Height: the absolute position of the table, measured by the transducers, at which the phase ends.

If you select the Time Type, the value is reset to zero and the time field appears in its place.

Availability: Machine option configured by CEMAS: Automatic parameter change; without this option, the values cannot be modified whilst the machine is in automatic mode.

Appearance: white field with a green border followed by mm.

Position: Tool Settings > Welding Parameters page, Time / Dimension column of the table, in the row for the phase.

Amplitude

The Amplitude column shows the amplitude of the vibration in phase, in millimetres (mm). This cannot be changed when the Welding Type is set to Preheating only (on the Equipment Settings > Configuration page).

Availability: on machines with vibration only.

Position: Equipment Settings > Welding Parameters page, last column of the table.

Cooling phase

The cooling phase follows the welding phases: the workpieces remain in contact with the set Force, in kgf, for the set Time, in seconds (s), so that the joint sets before unloading. The dot to the left of the line turns green whilst the phase is in progress on the side shown.

Availability: not available on HP machines (HP9, HP14, HP20, HP-P125).

Appearance: row with a white snowflake icon and fields for time and force.

Cooling phase in progress

Position: Equipment Settings > Welding Parameters page, last row of the table, below the + and − buttons.

Time / Altitude

The Time / Depth column contains the value that marks the end of the phase: the time, in seconds (s), for time-controlled phases and for stabilisation, settling and cooling phases; the depth or penetration, in millimetres (mm), for welding phases with the Type set to Relative depth or End-of-phase depth. Position: Equipment Settings > Welding Parameters page, Time / Depth column of the table.

Weather

The time field for a phase, in the Time / Elevation column, is the duration of the phase in seconds (s), to one decimal place, up to 99.9 s. In welding phases, it appears when the Type is Time; in stabilisation, settling and cooling phases, it is always present. If another Type is selected, the time is reset to zero and the depth or penetration field appears in its place.

Availability: Machine option configured by CEMAS: Automatic parameter change; without this option, the values cannot be modified whilst the machine is in automatic mode.

Appearance: white field with a green border followed by s.

Position: Tool Settings > Welding Parameters page, Time / Depth column of the table, in the row for the phase.

Force

The Thrust column shows the force with which the table pushes the workpieces during the operation, in kgf. On IR and HP machines, this column is called Maximum Thrust: see the related entry.

Position: Equipment Settings > Welding Parameters page, Force column of the table.

Welding limits

The Welding Limits button opens and closes the cycle acceptance limits panel above the phase table. For each parameter, there are Lower Limit, Upper Limit and Last Cycle Results; if the measured value is outside the limits, the workpiece is a scrap piece. The limits are set during the first cycle with new tools and are refined in subsequent cycles based on actual values. The button is also used when the machine is in automatic mode.

The parameters monitored are Welding time, Welding depth, Welding start position and End welding position; these vary on IR and HP models: see the relevant section.

Appearance: the text WELDING LIMITS with a round green button featuring a black gear icon; the open panel has a green border.

Welding limits

Position: Equipment settings > Welding parameters page, top right.

Welding time

Execution time of the entire welding cycle, i.e. time in which the vibration is actually generated, expressed in s. If the real welding time is not within the set limits, the automatic processing cycle of the welding machine will not be interrupted, but the machine will indicate a fault by means of an alarm and will generate a scrap piece.

Lower limit

Column showing the minimum acceptable values for each parameter in the panel: a measured value lower than this results in the part being declared a scrap piece. Enter the value in the field, using the unit indicated alongside.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, first column of fields.

Upper limit

Column showing the maximum acceptable values for each parameter on the panel: a measured value higher than this renders the part a scrap piece. Enter the value in the field, using the unit indicated alongside.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, second column of fields.

Results of the latest cycle
1.4.14

Column showing the values measured by the machine during the last cycle, to be compared with the limits in order to set or fine-tune them. If a value is outside the limits, the machine signals the fault with an alarm and the workpiece is a scrap piece.

Appearance: values in white digits with the unit, cannot be edited.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, the right-handmost column.

Welding depth

Row showing the limits for the total depth of workpieces during the cycle, in millimetres (mm): Lower limit, Upper limit and, in the Last cycle results column, the measured depth. On IR and HP machines, this row is called Cooling depth. If the value from the last cycle is outside the limits, the machine signals the fault with an alarm and the workpiece is rejected. The automatic cycle is not interrupted.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, below the time line.

Lower limit

Column showing the minimum acceptable values for each parameter in the panel: a measured value lower than this results in the part being declared a scrap piece. Enter the value in the field, using the unit indicated alongside.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, first column of fields.

Upper limit

Column showing the maximum acceptable values for each parameter on the panel: a measured value higher than this renders the part a scrap piece. Enter the value in the field, using the unit indicated alongside.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, second column of fields.

Results of the latest cycle
1.4.14

Column showing the values measured by the machine during the last cycle, to be compared with the limits in order to set or fine-tune them. If a value is outside the limits, the machine signals the fault with an alarm and the workpiece is a scrap piece.

Appearance: values in white digits with the unit, cannot be edited.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, the right-handmost column.

Welding start position

The line indicating the table height limit at which welding begins, in millimetres (mm), based on the value from the last cycle. On IR and HP machines, this line is called Cooling Start Height. With new tools, start with wide limits (for example, from 0.00 to 800.00 mm) and narrow them down after the first cycle based on the actual value.

On vibration machines, the position is checked at the end of stabilisation or settling: if it is outside the limits, welding does not start, the machine triggers an alarm and the workpiece is rejected. On IR and HP machines, the position is checked during welding: if it is outside the limits, the machine triggers an alarm and the workpiece is rejected, but welding and cooling are not interrupted.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, below the depth line.

Lower limit

Column showing the minimum acceptable values for each parameter in the panel: a measured value lower than this results in the part being declared a scrap piece. Enter the value in the field, using the unit indicated alongside.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, first column of fields.

Upper limit

Column showing the maximum acceptable values for each parameter on the panel: a measured value higher than this renders the part a scrap piece. Enter the value in the field, using the unit indicated alongside.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, second column of fields.

Results of the latest cycle
1.4.14

Column showing the values measured by the machine during the last cycle, to be compared with the limits in order to set or fine-tune them. If a value is outside the limits, the machine signals the fault with an alarm and the workpiece is a scrap piece.

Appearance: values in white digits with the unit, cannot be edited.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, the right-handmost column.

Welding end height

Line indicating the height limits of the table at which the welding ends, in millimetres (mm), based on the value from the last cycle. On IR and HP machines, this line is called Cooling End Height. If the value from the last cycle is outside the limits, the machine signals the fault with an alarm and the workpiece is rejected. The automatic cycle is not interrupted.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, under Welding Start Position.

Lower limit

Column showing the minimum acceptable values for each parameter in the panel: a measured value lower than this results in the part being declared a scrap piece. Enter the value in the field, using the unit indicated alongside.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, first column of fields.

Upper limit

Column showing the maximum acceptable values for each parameter on the panel: a measured value higher than this renders the part a scrap piece. Enter the value in the field, using the unit indicated alongside.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, second column of fields.

Results of the latest cycle
1.4.14

Column showing the values measured by the machine during the last cycle, to be compared with the limits in order to set or fine-tune them. If a value is outside the limits, the machine signals the fault with an alarm and the workpiece is a scrap piece.

Appearance: values in white digits with the unit, cannot be edited.

Position: Equipment Settings > Welding Parameters page, Welding Limits panel, the right-handmost column.

Welding parameters – Vibration

On vibration machines, the table shows, in order: the stabilisation phase, the settling phase (in the advanced view or if enabled), the welding phases and the cooling phase. The columns are Type, Time / Quota, Force and Amplitude, where the amplitude of the vibration is given in millimetres (mm). With the Welding type set to Preheating only, the amplitude cannot be adjusted.

The button with the printer icon opens a preview of the receipt showing the equipment parameters: a header with the equipment ID and the customer’s details, date and time; for each model, the welding stages and limits; the results of the last cycle; the table dimensions; and, on infrared machines, the times and parameters of the IR zones. The receipt is in the print language selected for the current language setting. The button with the printer icon below the preview sends it to the machine’s printer; the pop-up closes using the down arrow. The button can also be used whilst the machine is in automatic mode.

Availability: machine option configured by CEMAS: Printer; the button appears if the machine is fitted with a printer.

Appearance: round green button with a black printer icon.

Print parameters

Receipt preview

Position: Tools settings > Welding parameters page, bottom row, centred.

Manual welding

The Manual Welding switch prepares the machine for manual welding on the side shown on the tab: when activated, the text changes to Press the START CYCLE button to start manual welding and welding begins when START CYCLE is pressed. Manual welding performs only the welding sequence using the parameters on the page, without the cycle movements, and starts only in manual mode, with the welding machine ready and the table already in force control mode, i.e. with the workpieces in contact. Deactivating the switch, or changing the tab, stops the welding process.

The switch is grey when the machine does not allow manual welding.

Availability: machine option configured by CEMAS: Manual welding; the switch appears if the option is active.

Appearance: the text Manual welding and a switch on the right; when activated (green circle with a tick), the text is replaced by the message Press the START CYCLE button to start manual welding.

Manual welding

Manual welding enabled

Position: Equipment Settings > Welding Parameters page, bottom row on the right-hand side.

Synoptic

The Synoptic page is dedicated to the graphical representation of a smart tool. In the current version of the software, the page is still under development: it displays only a grid onto which you can drag certain test icons with your finger, and which can be zoomed in or out using two fingers. Any actions performed on this page are not saved and have no effect on the machine or the tool.

Availability: tool option: appears when a smart tool is loaded (Tool Settings > Configuration, Table Plug Type tab with the IoLink plug selected and the Smart Tool box ticked).

Appearance: a grey chequered grid on a dark background with several white square icons featuring a viewfinder.

Position: Equipment Settings > SYNOPTICS menu.

Smart tools

The Smart Tool page is dedicated to configuring a smart tool: a tool equipped with its own PLC that exchanges signals with the welding machine via the IoLink connector. In the current version of the software, this page is under development and does not display any content.

The signals from the Smart Tool are already used on the Tool Settings > Actuators and Presences page, in the Input Commands and Output Commands tabs, by selecting Smart Tool mode in the Signal unit. When a smart tool is loaded, the bar at the bottom displays, next to the tool, a blue icon labelled Smart Tool System.

Availability: tool option: appears when a smart tool is loaded (Equipment Settings > Configuration, Table Plug Type card with the IoLink plug and the Smart Tool box ticked).

Appearance: blank page.

Position: Equipment Settings > Smart Tools menu.