Skip to content

Machine diagnostics

The Machine Diagnostics unit contains pages for checking the status of the machine and its components, manually operating machine and tool elements, carrying out tests, and viewing calibrations and certifications.

Pages in this unit:

  • PLC, Motor status, Machine test, Service, Manual movements, Calibrations and certifications;
  • Transducers: only on machines with position transducers;
  • Cooling system: only on certain laser models;
  • Laser system: only on laser machines;
  • Smart accessory: only when the smart accessory is installed; opens in a pop-up;
  • Periodic operations: only on IR and HP machines.

Tapping the unit on the Home page opens a pop-up showing, on the left, the icon, name and description of the unit and, on the right, the list of pages; these same pages are in the side menu.

Appearance: a green square icon with a crossed-out key and screwdriver.

Position: on the Home page, third unit in the top row.

PLC

The PLC page displays the status of the signals and cards in the PLC that controls the machine. It is used for troubleshooting: to check whether a sensor is sending a signal to the PLC, whether an output is being activated, or whether a card has a fault.

The page is divided into tabs:

  • Card Monitoring: inputs and outputs for each card, voltage presences and PLC scan time;
  • PLC Hardware: the cards installed in the PLC and their status;
  • Pin Decoding: status of the tool connector pins and code read;
  • Smart accessory: signals exchanged with the smart accessory, only if present and configured;
  • Signals: signals exchanged with external devices (remote buttons, indicators, robots, traceability), only if configured.

The page is always accessible, even without logging in.

PLC

Position: Machine Diagnostics > PLC menu.

Card monitoring

The Card Monitoring tab displays the status of the PLC’s inputs and outputs in real time, card by card.

The tab is divided into four areas:

  • Inputs, top left: the input cards;
  • Voltage Presences, bottom left: the monitored power supply circuits, if configured;
  • Outputs, top right: the output cards;
  • PLC Scan Time, bottom right: the PLC cycle times.

The complete list of signals, with the meaning of each address, is shown in the machine’s wiring diagram.

Card Monitoring

Position: Machine Diagnostics > PLC page, Card Monitoring tab, first tab at the top left.

Input

The Inputs area displays a card for each input card present, in address order.

  • Digital cards: the title is DI- followed by the first byte of the address; each input has an indicator light and the address in the form byte.bit (e.g. 4.3). The indicator light is green when the input is active, and grey when it is not.
  • Analogue cards: the label is AI- followed by the address; each channel displays the address (e.g. IW102) and the value read.

A symbol to the right of the label indicates the card type:

Icon Card type
No icon No icon: machine input/output module card.
Safety Safety: card for safety functions.
Generic connector Generic connector: signals from decentralised peripherals, such as PROFINET patch panels or remote modules.

If not all cards fit within the area, the list scrolls vertically.

Appearance: grey cards with the title in capital letters and two columns of round indicator lights with the address next to them.

Inputs

Analogue card

Position: Machine Diagnostics > PLC page, Card Monitoring tab, top-left area with the heading INPUTS.

Voltage presences

The Voltage Presences section displays the status of the power supply circuits controlled by the PLC. Each circuit has an indicator light, a name and, in square brackets, the control number: the indicator light is green when voltage is present, and grey when it is absent.

The following circuits are usually present on the machines:

  • Aux: auxiliary voltage supply (24 V);
  • 24B: emergency circuit;
  • 24C: operator safety circuit, which allows the machine to safely perform movements that are hazardous to the operator.

The names and numbers of the circuits depend on the machine’s configuration. This section appears only if at least one voltage monitor has been configured.

Availability: machine option: appears if at least one voltage monitoring function is configured (Machine settings > General settings > Components, Voltage presences).

Appearance: list of round indicator lights showing the circuit name.

Voltage Presences

Position: Machine Diagnostics > PLC page, Card Monitoring tab, bottom-left area titled VOLTAGE PRESENCES.

Outputs

The Outputs area displays a card for each output card present, in address order.

  • Digital cards: the title is DO- followed by the first byte of the address; each output has an indicator light and the address in the form byte.bit. The indicator light is green when the PLC is driving the output, and grey when it is not.
  • Analogue cards: the label is AO- followed by the address; each channel shows the address (Q followed by the type and the address, such as QW) and the written value.

The symbol to the right of the label indicates the type of card, as with Inputs.

Appearance: grey cards with the title in capital letters and two columns of round indicator lights with the address next to them.

Outputs

Active outputs

Position: Machine Diagnostics > PLC page, Card Monitoring tab, top-right area with the heading OUTPUTS.

PLC scan time

The PLC scan time section shows how long it takes the PLC to complete a full cycle of its programme, in milliseconds (ms):

  • Current: duration of the last cycle;
  • Minimum: shortest cycle recorded;
  • Maximum: longest cycle recorded.

Long cycle times or a maximum value significantly higher than the current value may indicate that the PLC is overloaded. Minimum and Maximum are reset to zero every time the PLC restarts (when switching from STOP to RUN).

Appearance: three values in white digits followed by ms, each with its own grey icon.

PLC scan time

Position: Machine Diagnostics > PLC page, Card Monitoring tab, bottom-right area titled PLC SCAN TIME.

PLC hardware

The PLC Hardware tab displays a diagram of the cards installed in the PLC’s input/output module, showing their installed positions and the status of each one. The position number is shown beneath each card; the address is indicated on the cards themselves.

Above each card there is an indicator:

  • green tick: the card is functioning correctly;
  • red exclamation mark: the card has a fault and must be checked by a maintenance technician.

The most common causes of a faulty board are:

  • the card is not correctly inserted into its socket;
  • faulty socket (check by moving a working card into that position);
  • faulty or damaged card: replace it with one of the same model.

This tab is read-only: card configuration is set in Machine Settings > General Settings, which is restricted to authorised operators.

Appearance: a diagram showing cards side by side, with a round green or red icon above each one.

PLC Hardware

Faulty card

Position: Machine Diagnostics > PLC page, second tab at the top.

PLC Hardware – Lasers

On laser machines, the PLC may have several input and output modules: on the left, there is a column of vertical tabs labelled IM1, IM2 and IM3, one for each module with at least one configured card, and each tab displays the cards for its respective module.

PLC configuration

The configuration of the PLC cards (which cards are fitted and in which position) is set by CEMAS when the machine is put into service. The PLC Hardware tab displays this information in read-only mode, together with the status of each card.

If a card is replaced with a different model, or a new card is added, the configuration must be updated by a CEMAS technician; otherwise, the card will be flagged as faulty.

Warning Do not replace a card with a different model without CEMAS’s intervention: the machine will report the card as faulty and will not be able to operate.

Position: Machine Diagnostics > PLC page, PLC Hardware tab.

PIN Decoding

The Pin Decoding tab displays the pins on the tools’ connectors and their status, so that you can check which tool code the machine is reading.

Each pin has an indicator light: grey when the pin is off, green when it is on. Each pin is assigned a binary weight (1, 2, 4, 8, 16, 32): the sum of the weights of the active pins gives the code of the connected tool. The tab is therefore used for diagnostics: to locate the pin in the connector, check its status and verify the code read.

The connectors are grouped by machine section (Table, Head, Spindle) and by socket type (24-pin, 32-pin, 64-pin bus), according to those installed and enabled. If no connectors are enabled, the tab displays the message No connectors to display.

Position: Tool Change > Tool Change, top tab; the same tab can also be found on the Machine Diagnostics > PLC page.

24-pin

The 24-pin tab shows the layout of the tools’ 24-pin socket, with an indicator for each coding pin and its weight, from Weight 1 to Weight 32. The indicator is green when the pin is active; the sum of the weights of the active pins is the tool code read by the machine.

Availability: machine option: appears if the 24-pin socket is enabled for that part of the machine; this option is configured via CEMAS.

Appearance: diagram of the socket with round grey or green indicator lights and the weight labels.

Position: Tool Change > Tool Change page, Pin Decoding tab, 24-Pin tab under the machine section (Table, Head, Mirror); also in Machine Diagnostics > PLC.

32-pin

The 32-pin tab shows the layout of the tools’ 32-pin socket, with the indicator for each coding pin and its weight, from Weight 1 to Weight 64, and the word Columns on the column pin. The indicator is green when the pin is active; the sum of the weights of the active pins is the tool code read by the machine.

Availability: machine option: appears if the 32-pin socket is enabled for that part of the machine; this option is configured via CEMAS.

Appearance: illustration of the socket with round grey or green indicator lights and the weight labels.

Position: Tool Change > Tool Change page, Pin Decoding tab, 32-Pin tab under the relevant machine section; also in Machine Diagnostics > PLC.

64-pin bus

The 64-pin bus tab displays a diagram of the tool’s 64-pin bus socket, showing the indicator for each coding pin and its weight. The indicator is green when the pin is active; the sum of the weights of the active pins is the tool code read by the machine.

Availability: machine option: appears if the 64-pin bus socket is enabled for that machine section; this option is configured via CEMAS.

Appearance: diagram of the socket with round grey or green indicator lights and weight labels.

Position: Tool Change > Tool Change page, Pin Decoding tab, 64-pin Bus tab under the machine section; also in Machine Diagnostics > PLC.

Customised

The Custom tab appears for a custom tool holder, which differs from CEMAS tool holders. The tool holder drawing is not available: a generic image appears instead.

Availability: machine option: appears if the custom tool holder is enabled and is of a displayable type; this option is configured by CEMAS.

Position: Tool Change > Tool Change page, Pin Decoding tab, Custom tab under the machine section; also in Machine Diagnostics > PLC.

Smart accessory

Option

The Smart accessory tab displays the signals exchanged between the machine and the smart accessory.

  • Inputs, on the left: the signals that the smart accessory sends to the machine;
  • Outputs, on the right: the signals that the machine sends to the smart accessory.

Each signal is a row containing the configured name and a status indicator, which is green when the signal is active. If a column has no signals, the message No commands available appears.

This tab appears only if the smart accessory is present and at least one signal is configured for the smart accessory. Signals are defined according to the system and are configured only by an authorised CEMAS technician. Other signals to external devices are in the Signals tab.

Availability: machine option: appears if the Smart accessory is present (Machine settings > General settings > Optionals, Smart accessory) and at least one signal is assigned to the smart accessory (Machine settings > General settings > Components, Input commands or Output commands).

Appearance: rounded black lines with an icon, the name in capital letters and the indicator light on the right.

Smart accessory

Position: Machine Diagnostics > PLC page, Smart accessory tab at the top, after Pin Decoding.

Signals

The Signals tab displays the status of digital signals exchanged with external devices, such as remote buttons, indicators, robots or tracking systems. It is divided into two columns:

  • Inputs, on the left: the signals that external devices send to the machine;
  • Outputs, on the right: the signals that the machine sends to external devices.

Each signal is a row containing the configured name (or Input command or Output command followed by a number, if it has no name) and an indicator light, which is green when the signal is active. If a column has no signals, the message No commands available appears. Here, the signals are for reference only: manually controllable outputs are activated on the Machine Diagnostics > Manual Movements page, under the Signals tab.

Availability: machine option: appears if at least one input or output is configured as a digital signal (Input commands and Output commands), an option configured via CEMAS.

Appearance: tab with the heading Signals at the top; two columns with a grey icon and the headings INPUTS and OUTPUTS; rounded black rows with an icon, the name in capital letters and the indicator light on the right.

Position: Machine Diagnostics > PLC page, topmost tab.

Motor status

The Motor Status page displays the operating values of the machines’ drives: current, torque, force, position, temperature and homing status. It is used for diagnostics and to check the behaviour of the axes during movements.

In the Machine tab, there is a card for each drive, with its name in the top left-hand corner. Which cards appear depends on the machine’s technology and configuration:

  • Mirror/Head (infrared and hot plate machines) or Mirrors (vibration machines with two IR mirrors);
  • Rotation axis, on IR and HP machines where mirror rotation is enabled;
  • Table motor, on all machines;
  • Translating table, on hydraulic vibration machines with a translating table.

The Gates tab appears only on machines with motorised gates and displays the same values for the gate motors.

Each card has an i icon in the top right-hand corner, which opens the drive diagnostics pop-up: drive fault and warning codes, and the status of individual status, alarm and warning bits; tapping a bit displays its description.

The Referenced indicator for each axis is green when the axis is at the reference position: the encoder was reset to the correct position during putting into service. If a motor is replaced, contact CEMAS to carry out the position reset procedure.

This page is always accessible, even without logging in.

Motor status

Drive diagnostics

Appearance: the Home indicator is green when the axis is home-positioned, and grey when it is not.

Home-positioned

Position: Machine diagnostics > Motor status menu.

Table motor

The Table Motor card displays the operating values of the electric motor that drives the table:

  • Motor Current and Torque (torque only for certain drive types);
  • Thrust Force and, where present, Load cell;
  • Table position and transducers;
  • Motor temperature;
  • Referenced indicator light; on machines with an IR cam mirror, also the In Cam indicator light.

The i icon in the top right-hand corner opens the drive diagnostics pop-up.

Appearance: a tab with a grey table icon and the title TABLE MOTOR; each row has the name on the left, the value in white digits in the centre and a grey icon on the right.

Table motor

Position: Machine Diagnostics > Motor Status page, Machine tab, Table motor card, to the right of the mirror and rotation axis cards, if present.

Current

The Current row displays the current drawn by the motor, in amperes (A), to one decimal place. The value is updated in real time and is zero when the motor is stationary and not powered.

Availability: on the Table Motor card, this does not appear on hydraulic vibration machines (901-ST, 901-HL, 902-HL, 911, 918, 950-ST, 950-HL, 999-HL, 999-XT).

Appearance: a row showing the value in white digits followed by A and a grey lightning bolt icon.

Current

Position: Machine Diagnostics > Motor Status page, Machine tab, in the drive cards; in the Table Motor card, it is the first row.

Couple

The Torque row shows the torque produced by the motor, in newton-metres (Nm), to one decimal place. It appears only for certain types of drive.

Availability: on the Table Motor tab, this does not appear on hydraulic vibration machines (901-ST, 901-HL, 902-HL, 911, 918, 950-ST, 950-HL, 999-HL, 999-XT). Machine option: appears only for Siemens-type axes; option configured by CEMAS.

Appearance: a row showing the value in white digits followed by Nm and a grey icon of a circle with two curved arrows.

Torque

Position: Machine Diagnostics > Motor Status page, Machine tab, in the drive cards, under Current.

Come on

The Force row shows the force of the table, in kgf, without decimals. This is the force calculated by the machine, via force calibration, based on:

  • the motor torque, on electric machines;
  • the oil pressure, on hydraulic machines;
  • the internal load cell, if the machine uses it to regulate force.

If the load cell is installed, the force measured by it also appears in the Load Cell row.

Appearance: a row showing the value in white digits followed by kgf and the grey icon of downward-pointing arrows on a base.

Force

Position: Machine Diagnostics > Motor Status page, Machine tab, Table Motor card, under Torque.

Load cell

Option

The Load cell row displays the force measured by the load cell installed beneath the table, in kgf. The load cell is optional and allows for more precise adjustment of the force.

This row appears only on machines fitted with a load cell.

Availability: machine option: appears if the table is fitted with a load cell, an option configured by CEMAS.

Appearance: line displaying the value in white digits followed by kgf and the same icon as Force.

Load cell

Position: Machine Diagnostics > Motor Status page, Machine tab, Table Motor card, under Force.

Position

The Position line shows the position of the axis as read by the motor, in millimetres (mm): with three decimal places for the table, and two for the other axes.

Appearance: a line displaying the value in white digits followed by mm and a grey ruler icon.

Position

Position: Machine Diagnostics > Motor Status page, Machine tab, in all drive cards.

Temperature

The Temperature row displays the motor temperature in degrees Celsius (°C), to one decimal place. On the mirror and head cards, this appears only with certain drive types.

Availability: on the Table motor card, this does not appear on hydraulic vibration machines (901-ST, 901-HL, 902-HL, 911, 918, 950-ST, 950-HL, 999-HL, 999-XT).

Appearance: a line showing the value in white digits followed by °C and a grey thermometer icon.

Temperature

Position: Machine Diagnostics > Motor Status page, Machine tab, in the drive cards; in the Table Motor card under Position.

Transducers

The Transducers line displays the absolute position of the table, as measured by the position transducers, relative to machine zero, in millimetres (mm), to three decimal places. The transducers are configured on a machine-by-machine basis: either at the bottom only, two sensors on a single transducer, or two transducers. With transducers, the measurement is independent of the Position read by the motor; on machines without transducers, the line displays the position read by the table motor.

Appearance: a line with the value in white digits followed by mm and a grey ruler icon.

Transducers

Position: Machine Diagnostics > Motor Status page, Machine tab, Table Motor card, above the Referenced indicator light.

Cited

The Referenced indicator shows whether the axis has a reference position: the motor encoder was zeroed to the correct position during putting into service, so the positions read are reliable. If the indicator is off, the axis cannot move to a specific position. If a motor is replaced, contact CEMAS for the procedure to reset the reference position.

Appearance: a row with a grey house icon and a round indicator light, which is green when the axis is referenced and grey when it is not.

Referenced

Position: Machine Diagnostics > Motor Status page, Machine tab and Gates tab, last row for each motor.

Cited

The Referenced indicator shows whether the axis has a reference position: the motor encoder was zeroed to the correct position during putting into service, so the positions read are reliable. If the indicator is off, the axis cannot move to a specific position. If a motor is replaced, contact CEMAS for the procedure to reset the reference position.

Appearance: a row with a grey house icon and a round indicator light, which is green when the axis is referenced and grey when it is not.

Referenced

Position: Machine Diagnostics > Motor Status page, Machine tab and Gates tab, last row for each motor.

Gates

The Gates tab displays the operating values for the motors of the motorised gates, with one card for the Front gate and one for the Rear gate.

Availability: Machine option: appears if the gate is present and is motorised with a single shaft (Gates, HDT or Siemens type), an option configured by CEMAS.

Appearance: tab labelled Gates at the top, to the right of the Machine tab.

Gates

Position: Machine Diagnostics > Motor Status page, second tab at the top.

Gate motor

The Front and Rear cards display the gate motor’s values: Current, Position in millimetres (mm) and the Referenced indicator light; with the Siemens drive, Torque and Temperature are also shown.

The i icon in the top right-hand corner opens the drive diagnostics pop-up.

Availability: Machine option: appears if the gate is present and is motorised with a single axis (Gates, type HDT or Siemens), an option configured by CEMAS.

Appearance: a card with a grey vertical axis icon and the title FRONT or REAR; each row has the name on the left, the value in white digits and a grey icon on the right.

Gate motor

Position: Machine Diagnostics > Motor Status page, Gates tab, with the Front card on the left and the Rear card on the right.

Cited

The Referenced indicator shows whether the axis has a reference position: the motor encoder was zeroed to the correct position during putting into service, so the positions read are reliable. If the indicator is off, the axis cannot move to a specific position. If a motor is replaced, contact CEMAS for the procedure to reset the reference position.

Appearance: a row with a grey house icon and a round indicator light, which is green when the axis is referenced and grey when it is not.

Referenced

Position: Machine Diagnostics > Motor Status page, Machine tab and Gates tab, last row for each motor.

Status word

The drive diagnostics pop-up opens via the i icon on each card and has a tab for each motor. At the top, for Siemens drives, there are Drive fault code and Drive warning code – the drive’s fault and warning codes to be reported to support. Below, the Status word and Status word 2 cards list the axis status bits, for example Enable (axis enabled), HomingDone (axis homed), Standstill (axis at a standstill) or software and hardware limits that have been reached.

Tapping a bit opens its description. The bit names are the standard drive names and remain in English.

Appearance: a card with a list of rows, each containing a round indicator light (green when the bit is active) and the bit name; the arrow on the right opens the description.

Status word

Position: Machine Diagnostics > Motor Status page, Machine tab, pop-up open with the i icon of a card, card on the left.

Alarms word

The Alarms word tab lists the drive’s alarm bits, such as DriveFault (drive fault), SensorFault (encoder fault), FollowingErrorFault (tracking error) or HomingError (homing error). An active bit indicates the cause of the axis alarm; tapping it displays the description.

Appearance: a list of rows with a round red indicator when the bit is active, grey otherwise.

Position: Machine Diagnostics > Motor Status page, Machine tab, pop-up window opened via the i icon (card icon), Alarms word card.

Warnings

The Warnings word card lists the drive’s warning bits, for example DriveWarning, SWLimitMin and SWLimitMax (software limits reached) or FollowingErrorWarning. A warning does not stop the axis but indicates a condition that requires checking; tapping the bit displays the description.

Appearance: a list of rows with a round yellow indicator when the bit is active, grey otherwise.

Position: Machine Diagnostics > Motor Status page, Machine tab, pop-up window open with the i icon (representing a card), Warnings word card.

Machine test

The Machine Test page lists the test procedures used to verify the operation of the welding machine. It is divided into side-by-side tabs:

  • VCU: vibration test, for vibration welding machines only;
  • Thrust: verification of the table’s force;
  • Dry run cycle: automatically repeated test cycles.

The controls on this page may only be used whilst the machine is in manual mode (the MANUAL CYCLE button on the panel frame) and only by users with access to the page; they are disabled whilst the machine is in automatic cycle mode.

Warning Testing is restricted to CEMAS Elettra personnel or authorised personnel: during tests, the machine performs actual movements and cycles.

Machine test

Position: Machine Diagnostics > Machine Test menu.

Force

The Thrust card allows you to check the table’s force.

With the machine in manual mode, move the table using the arrow keys on the panel frame to the required position for the test: the card displays the force in real time, along with a green horizontal bar ranging from 0 to the machine’s maximum force.

Appearance: a card titled FORCE, featuring a line displaying the value and a green horizontal bar on a grey background, with the scale in kgf.

Force

Position: Machine Diagnostics > Machine Test page, Thrust card: first on the left, or to the right of the VCU card on machines with vibration.

Force

The Force row shows the thrust force of the table during the test, in kgf, without decimal places.

Appearance: a row with the value in white digits followed by kgf and the grey icon of downward-pointing arrows on a base.

Force

Position: Machine Diagnostics > Machine Test page, Force tab, first row.

Dry run cycle

The Dry run cycle card sets the welding machine’s test cycle: the machine carries out repeated processing cycles on its own, for the set number of times and with a pause between each cycle.

  • Skip welding: carries out the cycles without the welding phase; this option is always visible.
  • Enabled, Repeat and Delay: these only appear when Putting into service is active, which is enabled via the tool icon in the top bar.

When the test cycle is enabled, the yellow DRY icon appears in the top bar; if only Skip welding is active, the icon is grey.

On vibration machines with an IR mirror, the tab has an extra row: see the related entries.

Appearance: tab with the title DRY RUN CYCLE and rows containing switches and fields.

DRY icon

DRY icon

Position: Machine Diagnostics > Machine Test page, Dry run cycle card, on the right.

Authorised

The Enabled switch activates the test cycle. When the switch is active, you can adjust the Repetition and Delay settings, and the yellow DRY icon appears in the top bar.

Test cycles are performed only in automatic mode with Putting into service enabled. The first cycle is started using the START CYCLE button; subsequent cycles start automatically after the Delay (2 s as standard), up to the number set in Repetition. On vibration welding machines, the machine returns to manual mode at the end of the cycle. Alarms on the welding machine do not halt the test cycles.

This line appears only when Putting into Service is active.

Availability: only when Putting into service is active; this can be enabled by users authorised to manage the machine.

Appearance: grey switch with an X when disabled, green with a tick when enabled.

Enabled

Position: Machine Diagnostics > Machine Test page, Dry run cycle tab, first row.

Skip welding

The Skip Welding switch causes the cycles to run without the welding phase: the cycle movements are carried out, but:

  • on machines with vibration, even those with infrared heating, the head does not vibrate;
  • on laser machines, the laser source does not emit;
  • on IR and HP machines, heating takes place, then the cycle skips the contact between the workpieces and the welding stage, and returns the table to the loading position.

When the switch is active, the DRY icon appears in the top bar.

Appearance: grey switch with an X when deactivated, green with a tick when activated.

Skip welding

Position: Machine Diagnostics > Machine Test page, Dry run cycle tab, under Enabled; without Putting into service, it is the first line.

Revision

The Repetition row shows, on the left, the number of test cycles already carried out and, in the field on the right, the number of cycles to be carried out. Usually, 250 cycles are set for hydraulic welding machines and 500 for electric ones.

The field can only be edited when Enabled is active. The row only appears when Putting into service is active.

Availability: only when Putting into service is active, which can be activated by users authorised to manage the machine.

Appearance: counter with white digits, a slash / and a white field showing the number of cycles.

Repetition

Position: Machine Diagnostics > Machine Test page, Dry run cycle card, under Skip welding.

Delay

The Delay field sets the pause between the end of one test cycle and the start of the next, in seconds (s), to two decimal places.

This field can only be edited when Enabled is active. The row only appears when Putting into service is active.

Availability: only when Putting into Service is active; this can be enabled by users authorised to manage the machine.

Appearance: blank field with the value followed by s.

Delay

Position: Machine Diagnostics > Machine Test page, Dry run cycle card, under Repetition.

Support

The Support page displays the welding machine’s identification data and operating counters, the status of remote support, and contact details for the CEMAS Elettra assistance service. These are the details you should provide when requesting support.

The page is divided into two columns:

  • on the left, the machine details: Technology, Model, Date of manufacture, Serial number, HMI release, PLC release, Operating hours, Total cycles, Pieces produced, PLC serial number and Memory card serial number;
  • on the right, the Remote Support section, the QR code for the Documentation and, at the bottom, Contact details.

The page is always accessible, even without logging in.

Support

Position: Machine Diagnostics > Support menu.

Support information

The column on the left-hand side of the Support page contains the welding machine’s identification details to be provided to CEMAS Support: Technology, Model, Date of manufacture, Serial number, HMI release, PLC release, Operating hours, Total cycles, Pieces produced, PLC serial number and Memory card serial number. Each row has its own help entry.

The data is read-only.

Appearance: a column of rows with the heading in grey on the left, the value in white and a grey icon.

Position: Machine Diagnostics > Support page, machine data column on the left.

Technology

The Technology row indicates the welding machine’s welding technology, for example Infrared welding.

Appearance: a row with the heading Technology in grey, the coloured symbol for the technology and the name in white.

Technology

Position: Machine Diagnostics > Service page, machine data column on the left, first row.

Model

The Model row indicates the model of the welding machine, for example IR9.

Appearance: a row with the heading Model in grey, the grey model logo and the name in white.

Model

Position: Machine Diagnostics > Support page, machine data column on the left, second row.

Remote Support Information

The section on the right-hand side of the Support page covers remote support and the welding machine’s documentation:

  • Remote support, with the Machine connected and Support connected indicators;
  • Documentation, with the QR code and the link to the welding machine’s online documentation;
  • Email, the address for requesting support from CEMAS.

Each item has its own help entry.

Position: Machine Diagnostics > Support page, right-hand column.

Date of manufacture

The Production date row shows the date on which the welding machine was manufactured (day, month and year), as recorded by CEMAS during testing. Together with the Serial number, this identifies the machine in service requests.

Appearance: a row with the heading Production date in grey, a grey calendar icon and the value in white.

Production date

Position: Machine Diagnostics > Service page, machine data column on the left, third row.

Serial number

The Serial number line shows the welding machine’s serial number, which should be provided to the assistance service.

Appearance: a line with the heading Serial number in grey, a grey barcode icon and the value in white.

Serial number

Position: Machine Diagnostics > Support page, in the machine data column on the left, below Date of manufacture.

HMI Release

1.1.16

The Release HMI line shows the versions of the software installed on the panel: HMI (the interface), API (the service that connects the interface to the machine and its database) and API Docs (the documentation service).

Tapping the row opens the CHANGELOG - HMI pop-up, which lists the new features and fixes for each version of the interface; the down arrow closes the pop-up.

On trial versions, a yellow triangle and the text pre-release appear after the version numbers.

Appearance: a row with the title HMI Release in grey, a grey rocket icon and the value in white.

HMI Release

Position: Machine Diagnostics > Service page, in the machine data column on the left, below Serial number.

PLC Release

The Release PLC line indicates the version of the programme installed on the PLC.

If the version is not compatible with that of the interface, the text Supported PLC version appears alongside it, showing the required version and a yellow triangle: in this case, please contact the assistance service.

Tapping the line opens a pop-up showing the version followed by the PLC programme control code, which helps the assistance service to identify the exact programme installed; the red icon with the X closes the pop-up.

Appearance: a row with the title PLC Release in grey, a grey icon of a rocket with a cog, and the value in white.

PLC Release

PLC Release Details

Position: Machine Diagnostics > Support page, machine data column on the left, below HMI Release.

Hours worked

The Working hours row shows the total operating time of the welding machine, in the format hours:minutes:seconds. It counts the time during which the machine is running the automatic cycle, excluding any waiting time for rejection confirmation; time during which the machine is simply switched on is not counted.

Appearance: a row with the heading Operating hours in grey, a grey clock icon with a tick, and the value shown in white.

Operating hours

Position: Machine Diagnostics > Service page, machine data column on the left, below PLC Release.

Total cycles

The Total cycles row shows the total number of processing cycles carried out by the welding machine. The counter increases at the end of each recorded cycle, including test cycles (Dry run cycle) and cycles that were interrupted after the initial stages. It cannot be reset from the control panel.

Appearance: a row with the heading Total cycles in grey, the grey icon of two circular arrows and the value in white.

Total cycles

Position: Machine Diagnostics > Service page, in the machine data column on the left, below Operating hours.

Items produced

The Pieces produced row shows the total number of pieces produced by the welding machine: on the left, the good pieces; on the right, the scrap pieces.

Appearance: a row with the heading Pieces produced in grey, a grey conveyor belt icon, the number of good pieces in green preceded by a tick, and the number of rejects in red preceded by an X.

Pieces produced

Position: Machine Diagnostics > Service page, machine data column on the left, below Total cycles.

PLC serial number

The PLC serial number row shows the serial number of the PLC CPU installed on the welding machine.

Appearance: a row with the heading PLC serial number in grey, a grey PLC icon and the value in white.

PLC serial number

Position: Machine Diagnostics > Service page, in the machine data column on the left, below Pieces produced.

Memory card serial number

The Memory card serial number row shows the serial number of the PLC’s memory card, which contains the machine programme.

Appearance: a row with the heading Memory card serial number in grey, a grey memory card icon and the value in white.

Memory card serial number

Position: Machine Diagnostics > Service page, machine data column on the left, bottom row.

Remote support

The Remote Support section displays the status of the remote connection to the CEMAS Elettra assistance service, with two indicator lights: Machine connected and Support connected.

Whilst a technician is connected, a round grey icon depicting an operator wearing headphones appears in a corner of the screen on all pages; tapping it moves it to the next corner, freeing up the required part of the screen.

Appearance: REMOTE SUPPORT heading in grey and two lines featuring a grey icon and a round indicator light.

Remote Support

Connected support

Position: Machine Diagnostics > Support page, Remote Support area in the top right-hand corner.

Connected machine

The Machine Connected indicator shows whether the machine is ready for remote connection to the assistance service:

  • green: the machine is ready for connection;
  • red: a remote connection is scheduled, but the machine is not ready;
  • grey: the signal is not configured on this machine.

The signal is received by the PLC as an input from the remote assistance device installed in the machine.

Appearance: a row with a grey icon of an electrical cabinet and a round indicator light on the right.

Machine not ready

Machine ready

Position: Machine Diagnostics > Support page, Remote Support area at the top right, first row.

Attached bracket

The Support connected indicator is green when a CEMAS Elettra S.r.l. assistance service technician is connected to the machine remotely, and grey when there is no connection.

Whilst connected, a round icon of an operator wearing headphones also appears in one corner of the screen; tapping it moves it to the next corner.

Appearance: a row with a grey icon of an operator wearing headphones and the round indicator light on the right.

Support connected

Connected device icon

Position: Machine Diagnostics > Support page, Remote Support area at the top right, below Connected machine.

Documentation

The Documentation section displays a QR code and, below it, the address of the welding machine’s online documentation in the language selected on the panel. Scanning the code with a smartphone opens the documentation for that machine model.

When Putting into Service is active, the code links to documentation reserved for CEMAS personnel.

Availability: appears if the machine type is set; this option is configured by CEMAS.

Appearance: white QR code with the address below.

Documentation

Position: Machine Diagnostics > Support page, under the Remote Support section.

Email

The Email line shows the email address for the CEMAS Elettra assistance service, [email protected], which should be used for support enquiries along with the machine’s Model and Serial number.

Appearance: a line with a grey snail icon and a blank address field.

Email

Position: Machine Diagnostics > Support page, Contacts section at the bottom right.

Manual movements

The Manual Movements page allows you to manually control the components of the installed tools and the machine’s main movements, for example to check that it is working correctly or to release a workpiece. It is divided into tabs:

  • Tools: presences, actuators and vacuums configured on the loaded tools;
  • Machine: machine axes, gates and, where present, safety guards;
  • Smart accessory: manual controls for the smart accessory, only if present and having at least one manually controllable output;
  • Signals: digital signals to external devices, only if at least one is manually controllable.

Controls are available in the following modes:

  • Table: manual movements in manual mode; during tool change, the tool-change movements are used, with speed limited to 30 per cent (50 per cent during Putting into Service);
  • Gates: opening and closing in manual mode and during tool change;
  • centerings: in all modes except the automatic cycle;
  • clamps, actuators, vacuum and blow: only in manual mode.

Gates, clamps and, on electric machines, the table moves only when the operator’s safety measures are in place (emergency stop restored, doors closed and safety barrier or gate closed and not bypassed); on hydraulic machines, the table requires only that the emergency stop be restored. Actuators move only if their safety constraints are met.

Warning The controls actually move axes and actuators: before using them, check that no one is in the work area and that the movements will not impact tools or workpieces.

Manual movements

Position: Machine Diagnostics > Manual movements menu.

Tools

The Tool tab displays the elements configured on the loaded tool, divided into three columns: Presences, Actuators and Voids. Each element is a row showing the name assigned in the configuration and its controls or indicator light.

The elements are configured on the Equipment Settings > Actuators, Presences and Voids page; a column with no elements displays a message, for example No actuators available.

Equipment

Appearance: tab labelled Tools in the top left-hand corner; three side-by-side columns, each with a grey icon and a title in capital letters.

Position: Machine Diagnostics > Manual Movements page, first tab at the top.

Attendance

The Presence column lists the equipment’s presence sensors, such as those that detect when a workpiece is in position. Each row contains the name of the presence sensor and an indicator showing the sensor’s status.

Presence sensors are configured on the Equipment Settings > Actuators, Presence Sensors and Vacuum page, under the Presence tab.

Appearance: a rounded black row with the name in white and a round indicator light on the right: green when the presence sensor is active, grey when it is not, red when the presence sensor is in alarm mode.

Presences

Indicator statuses

Position: Machine Diagnostics > Manual Movements page, Tools tab, left-hand column.

Actuators

The Actuators column lists the tool’s actuators, such as cylinders and grippers. Each row contains the name of the actuator and two buttons:

  • Rest moves the actuator to the rest position;
  • Work moves it to the working position.

Movement only occurs whilst the button is held down. When the actuator is in alarm mode, the buttons are disabled.

Actuators are configured on the Equipment Settings > Actuators, Presences and Vacuums page, under the Actuators tab.

Appearance: a rounded black bar with the name in white and two green buttons labelled REST and WORK. The button has a green halo when the actuator has reached the corresponding position; when the actuator is in alarm mode, the two buttons turn dark green with a red halo.

Actuators

Button states

Position: Machine Diagnostics > Manual Movements page, Tools tab, central column.

Vacuums

The Vacuum column lists the tools’ vacuum sockets, which hold the workpieces in place by suction. Each row contains the name of the vacuum socket and two buttons:

  • Vacuum activates the suction;
  • Blow activates the blow function, which releases the workpiece.

Commands are given with a single tap. Vacuum remains active until the blow function is activated, an alarm is triggered, or the vacuum is deactivated in the configuration. The blow function deactivates the vacuum and switches off automatically after the blow duration (2 s by default). The machine’s physical clamp button alternates between vacuum and blow. When the vacuum is in alarm mode, the buttons are disabled.

Vacuum settings are configured on the Equipment Settings > Actuators, Presences and Vacuums page, under the Vacuum tab.

Appearance: a rounded black row with the name in white and two green buttons labelled BLOW and VACUUM. Vacuum has a green halo when vacuum is achieved, Blow when blowing is active; when vacuum is in alarm mode, the two buttons turn dark green with a red halo.

Vacuum levels

Button states

Position: Machine Diagnostics > Manual Movements page, Tools tab, right-hand column.

Machine

The Machine tab manually controls the main movements of the welding machine. On the left, a column of tabs is used to select the unit:

  • Axes: a second column of tabs, one for each axis; on all machines there is Table, and on machines with a sliding table there is also Sliding Table;
  • Gates: only if the machine has at least one motorised gate;
  • Guards: only if a mirror guard is present.

Each axis tab displays a schematic diagram of the machine in the centre, with the moving part highlighted in yellow; on the right are the movement buttons and at the bottom is the Go to position bar.

The available axes depend on the machine’s technology: see the related entries.

Machine

Appearance: a tab labelled Machine at the top; grey tab columns on the left, with the selected tab shown in white.

Position: the Machine Diagnostics > Manual Movements page, second tab at the top.

Axes

The Axes tab lists the manual axis controls used during tool change, in a second column of tables:

  • Table: on all machines;
  • Mirror or Mirrors: on machines with an infrared heating mirror;
  • Mirror rotation: on IR and HP machines with mirror rotation enabled;
  • Translating table: on machines with a translating table;
  • Head: on IR and HP machines.

Each tab displays a schematic diagram of the machine, with the moving part highlighted in yellow, and the movement buttons.

Appearance: a column of tabs with a grey background to the right of the main column; the selected tab has white text.

Axes

Position: Tool Change > Tool Change page, Manual tab, first tab in the vertical column on the left.

Table

The Table tab controls the table axis during tool change.

  • On the right, two buttons with up and down arrows move the table; the target heights, in millimetres (mm), are shown above and below the buttons. Movement occurs only whilst the button is held down and only when the machine is in tool change mode.
  • At the bottom, the Trolley bar moves the table to the trolley coupling height.
  • In the centre, a schematic diagram of the machine with the table highlighted in yellow.

Appearance: a black vertical bar with two round green buttons featuring arrows; the button has a green outline when the table is at the height indicated next to it.

Table

Position: Tool Change > Tool Change page, Manual tab > Axes > Table.

Trolley

Option

The Trolley line raises the table to the height at which the trolley carrying the tools is attached, so that loading and unloading can take place safely.

The field displays the height in millimetres (mm) and can be edited by tapping it. The button on the right moves the table to the specified height: movement only occurs whilst the button is held down and only when the machine is in tool change mode. The height is reached when the button is highlighted in green.

Appearance: the text Trolley, a white field showing the height followed by mm, and a round green button with a black angled arrow.

Trolley

Position: Tool Change > Tool Change page, Manual tab > Axes > Table, bottom row.

# Go to position

The Go to position line moves the axis to a selected position. Enter the position in the field, in millimetres (mm), then hold down the button on the right: the axis moves whilst the button is held down and stops at the entered position.

The entered position is restricted to the limits defined in the Machine settings. The button is disabled when movement is not permitted.

Appearance: a line labelled Go to position, a white field containing the value followed by mm, and a round green button with a play arrow; the button has a green halo when the axis is at the entered height.

Go to position

Position: Machine Diagnostics > Manual Movements page, Machine > Axes tab, at the bottom of each axis’s tab.

Movement

The arrow buttons move the table up or down. The table only moves whilst the button is held down and stops at the height indicated above (top button) or below (bottom button), in millimetres (mm).

The target heights depend on the page and the machine’s status:

  • in Tool Change, these are the tool change heights;
  • in Manual Movements, with no tool loaded, these are the maximum stroke and minimum opening of the table; with the tool loaded, they are the workpiece contact height (or preheating height, with the mirror in position) and the loading height.

On hydraulic machines with the sliding table in undercut mode, the top button moves the table to the insertion height, indicated to the right of the buttons, and a third button appears which moves it to the piece taking height.

Appearance: a black vertical bar with two round green buttons featuring arrows; the button has a green outline when the table is at the height indicated beside it.

Movement

Position: Machine Diagnostics > Manual Movements page, Machine > Axes > Table tab, to the right of the drawing; Tool Change > Tool Change page, Manual > Axes > Table tab.

Gates

The Gates tab controls the machine’s gates during tool change. There is one row for each gate: Front and Rear.

The Open and Close buttons move the gate whilst they are held down, but only when the machine is in tool change mode. The button is highlighted in green when the gate is fully open or closed; if the gate is in alarm mode, the buttons turn dark with a red highlight and cannot be used.

On machines with two-hand control, instead of buttons there is a drop-down menu from which you select the movement, which is then initiated using the physical START button.

Availability: machine option: appears if at least one gate is present, either front or rear (Machine settings > General settings > Components, Gates).

Appearance: a rounded black bar displaying the gate name and two green buttons labelled OPEN and CLOSE; on the left, a schematic diagram of the machine with the gates highlighted in yellow.

Gates

Gate controls

Position: Tool Change > Tool Change page, Manual tab, Gates tab in the vertical column on the left.

Definition of a gate

Each motorised gate has a row labelled with its name, Front or Rear, and Open and Close buttons, which move the gate whilst they are held down. The gates move in both manual mode and during tool change only when the operator’s safety devices are in place (emergency stop restored, doors closed and safety barrier or gate closed and not retracted); closing the pneumatic gates also requires the gate’s safety devices (barriers and safety ribs) to be in place. During the tool change procedure, the gates are not moved automatically.

If the welding machine has a two-hand control, instead of buttons there is a drop-down menu from which the movement is selected, which is then executed using the machine’s physical buttons.

Availability: machine option: the row for each gate appears if that gate is present (Machine settings > General settings > Components, Gates).

Appearance: a rounded black row with the name in white and two green buttons labelled OPEN and CLOSE. The button has a green outline when the gate is fully open or closed; when the gate is in alarm mode, the buttons turn dark with a red outline and cannot be used.

Gate definition

Position: Machine Diagnostics > Manual Movements page, Machine tab > Gates, to the right of the machine diagram; Tool Change > Tool Change page, Manual tab > Gates.

Movement

The arrow buttons move the table up or down. The table only moves whilst the button is held down and stops at the height indicated above (top button) or below (bottom button), in millimetres (mm).

The target heights depend on the page and the machine’s status:

  • in Tool Change, these are the tool change heights;
  • in Manual Movements, with no tool loaded, these are the maximum stroke and minimum opening of the table; with the tool loaded, they are the workpiece contact height (or preheating height, with the mirror in position) and the loading height.

On hydraulic machines with the sliding table in undercut mode, the top button moves the table to the insertion height, indicated to the right of the buttons, and a third button appears which moves it to the piece taking height.

Appearance: a black vertical bar with two round green buttons featuring arrows; the button has a green outline when the table is at the height indicated beside it.

Movement

Position: Machine Diagnostics > Manual Movements page, Machine > Axes > Table tab, to the right of the drawing; Tool Change > Tool Change page, Manual > Axes > Table tab.

Go to position

The Go to position line moves the axis to a selected position. Enter the position in the field, in millimetres (mm), then hold down the button on the right: the axis moves whilst the button is held down and stops at the entered position.

The entered position is restricted to the limits defined in the Machine settings. The button is disabled when movement is not permitted.

Appearance: a line labelled Go to position, a white field containing the value followed by mm, and a round green button with a play arrow; the button has a green halo when the axis is at the entered height.

Go to position

Position: Machine Diagnostics > Manual Movements page, Machine > Axes tab, at the bottom of each axis’s tab.

Laser system manual movements

The LASER SYSTEM card allows the main movements of the laser emission system installed on the welding machine to be operated in manual mode. Movements must be previously configured in the MACHINE SETTINGS menu.

Laser source

The laser sources area lists the laser sources installed on the welding machine. The laser sources on the welding machine must be defined in the MACHINE SETTINGS menu, GENERAL SETTINGS page, COMPONENTS card.

Laser source definition

Each source is assigned to an object bearing the identification name of the source itself. The object contains: an editable field in which to enter the laser emission power, expressed in %, and the on, key to activate the source. The key must be held down to activate the source. If the LED for the key is lit green, the source is active.

Smart accessory

The Smart accessory tab allows you to manually control the outputs to the smart accessory that have been enabled for manual control. Each output is a row containing its configured name, the On button and an indicator light: the button activates the output with a tap and deactivates it with the next tap; the indicator light is green when the signals are active.

Availability: machine option: appears if the Smart accessory is present and at least one of its outputs is enabled for manual control (Output controls), an option configured by CEMAS.

Appearance: OUTPUTS column with rounded black rows; each row has a name, a green ON button with a green halo when the output is active, and a round indicator light.

Position: Machine Diagnostics > Manual Movements page, Smart accessory tab at the top, after Machine.

Signals

The Signals tab manually controls the digital outputs to external devices that support manual control, such as signals or commands to a robot. Each output is a row containing its configured name, the On button – which activates the output with a tap and deactivates it with the next tap – and a green indicator light when the signal is active.

Warning The outputs actually control the connected devices: before activating them, check the effect on the system.

Availability: machine option: appears if at least one digital output is enabled for manual control (Output Commands), an option configured by CEMAS.

Appearance: OUTPUTS column with rounded black rows; each row has a name, a green ON button and a round indicator light.

Position: Machine Diagnostics > Manual Movements page, topmost tab.

Calibrations and certifications

The Calibrations and Certifications page displays the results of the procedures that verify the force of the axes and, on machines with vibration, the vibration amplitude: measured values, outcome and date of the last test. This is a read-only page: procedures cannot be initiated from here.

The page is divided into tabs:

  • Table: calibration, certification and capability of the table force;
  • Planarity: planarity measurements taken on the table and, on IR and HP machines, on the mirrors;
  • Head: calibration, certification and capability of the head force, on IR and HP machines only;
  • VCU: calibration, certification and capability of the vibration amplitude, on vibration machines only;
  • Laser sources: calibration and certification of each enabled laser source, on laser machines only.

If the calibration of the table or head has been manually modified, the tab displays only Calibration, with the text Manually edited calibration on an orange band, and the Certification and Capability tabs are not displayed.

The page is always accessible, even without logging in.

Calibrations and Certifications

Head Calibration

Manually Edited Calibration

Position: Machine Diagnostics > Calibrations and Certifications menu.

Definition of calibration

Calibration establishes a relationship between the value set by the machine and the actual value measured by a reference instrument, such as a load cell for force or a power meter for laser power. Thanks to calibration, the value set in the parameters corresponds to what the machine actually produces.

Calibration is different from adjustment: calibration determines the current characteristics of an instrument and its accuracy, whilst calibration corrects the machine’s response to make it more accurate.

On the welding machine, calibration of the table force (and of the head, on IR and HP machines) ensures accurate force during the cycle; the procedures are carried out by CEMAS or authorised technicians, and the results can be viewed on this page.

Position: Machine Diagnostics > Calibrations and Certifications page.

Definition of ‘capability’

Statistical Process Control (SPC) is a set of statistical checks carried out on a process or an individual machine to monitor quality, prevent errors and reduce waste. The capability test assesses the variability of the machine using two indices:

  • Cm (machine capability): the proportion of times the machine’s variation falls within the tolerance range. It describes repeatability, without considering whether the values are centred on the nominal value; the higher the value, the better the machine.
  • Cmk: combines capability with centering relative to the nominal value. A high Cmk indicates low dispersion and values that are well centred within the tolerance.

A good Cm is essential: if it is low, the only alternative to repair is to widen the tolerance. If the Cmk is low but the Cm is high, the machine can be brought back within limits by a new calibration.

Cm

Cmk

Cm KO

Cm OK

Cm and Cmk

Position: Machine Diagnostics > Calibrations and Certifications page, Capability tab.

Table

The Table tab displays the results of the tests on the table’s force in a column on the left-hand side of the tab:

  • Calibration: the relationship between the force command for the axis and the measured force;
  • Certification: verification that the force falls within the tolerance range across multiple readings;
  • Capability: verification of force repeatability.

When calibration is adjusted manually, only Calibration appears. The Head tab, on IR and HP machines, has the same structure and displays the same data for the head axis.

Table

Appearance: tab labelled Table at the top; a column of grey tabs on the left, with the selected tab highlighted in white.

Position: Machine Diagnostics > Calibrations and Certifications page, first tab at the top.

Calibration

The Calibration tab displays the result of the last axis force calibration: calibration establishes a relationship between the axis force command and the force measured by a reference load cell, so that the force set in the parameters corresponds to the actual force.

At the top are the Minimum Force, Maximum Force and Calibration Result cards; below, the calibration graph.

Calibration

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Calibration tab in the left-hand column.

Minimum force

The Minimum Force card shows the minimum force that the scale can exert according to the latest calibration, in kgf: below this value, the force is not guaranteed.

Appearance: a card with the title MINIMUM FORCE, a grey icon showing downward-pointing arrows on a base, and the value in white digits followed by kgf.

Minimum force

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Calibration, Certification or Capability tab, top card.

Maximum force

The Maximum Force card shows the maximum force that the axis can exert according to the latest calibration, in kgf: exceeding this value may damage the machine.

Appearance: a card with the title MAXIMUM FORCE, a grey icon showing downward-pointing arrows on a base, and the value in white digits followed by kgf.

Maximum force

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Calibration, Certification or Capability tab, second card from the top.

Calibration result

The Calibration Result box shows the status of the procedure:

  • OK followed by the date (day/month/year), if the calibration has been completed;
  • In progress... whilst the procedure is running;
  • Interrupted if the last procedure was interrupted;
  • Not performed if the procedure has never been completed.

Appearance: a card with the title CALIBRATION RESULT and the status shown in white numerals; whilst the procedure is in progress, a white circle rotates to the left of the text.

Calibration result

In progress

Not performed

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Calibration tab, card in the top right-hand corner.

Calibration chart

The graph shows the data points recorded during calibration. The horizontal axis shows the Axis force reference, i.e. the force command given to the axis as a percentage (%) of the maximum force, ranging from 5 to 100; the curves are:

  • Force (Calibration cell): the force measured by the reference load cell, in kgf;
  • Axis force feedback: the force read by the axis, as a percentage (%);
  • Load cell: the force read by the machine’s load cell, as a percentage (%), only if the load cell is installed.

Each curve has its own vertical scale on the left, with an eye icon below it: tapping the eye hides or shows the curve. Tapping the graph brings up a vertical cursor showing the curve values at that point.

Availability: machine option: the Load Cell curve appears if the table is fitted with a load cell, an option configured by CEMAS.

Appearance: graph with blue lines on a dark grey background, with vertical scales on the left in the same colour as the curve; the crossed-out eye indicates a hidden curve.

Calibration graph

Visible curve

Hidden curve

Cursor

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Calibration tab, below the cards.

Certification

The Certification tab displays the result of the most recent axle force certification: the machine applies a series of preset forces (check points) and verifies that the force measured by the reference load cell falls within the tolerance.

At the top are the Minimum force, Maximum force and Certification result cards; below, the certification graph.

This tab does not appear if the calibration has been modified manually.

Certification

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Certification tab in the left-hand column.

Minimum force

The Minimum Force card shows the minimum force that the scale can exert according to the latest calibration, in kgf: below this value, the force is not guaranteed.

Appearance: a card with the title MINIMUM FORCE, a grey icon showing downward-pointing arrows on a base, and the value in white digits followed by kgf.

Minimum force

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Calibration, Certification or Capability tab, top card.

Maximum force

The Maximum Force card shows the maximum force that the axis can exert according to the latest calibration, in kgf: exceeding this value may damage the machine.

Appearance: a card with the title MAXIMUM FORCE, a grey icon showing downward-pointing arrows on a base, and the value in white digits followed by kgf.

Maximum force

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Calibration, Certification or Capability tab, second card from the top.

Certification result

The Certification Result box shows the status of the procedure:

  • OK followed by the date (day/month/year), if the measured force remained within tolerance at all checkpoints; Failed followed by the date if at least one checkpoint is out of tolerance;
  • In progress... whilst the procedure is running;
  • Interrupted if the last procedure was interrupted;
  • Not executed if the procedure was never completed.

Appearance: card with the title CERTIFICATION RESULT and the status shown in white text.

Certification result

Failed

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Header tab, Certification tab, card in the top right-hand corner.

Certification chart

The graph shows the certification point by point. The horizontal axis shows the Control points; the curves are:

  • Force setpoint: the required force at each point, in kilogram-force (kgf);
  • Force (calibration cell): the force measured by the reference load cell, in kgf;
  • two grey lines without a scale, the Upper limit and the Lower limit of the tolerance, calculated as a percentage of the maximum force or the setpoint at each point, depending on the machine settings.

Certification is passed if the measured curve lies between the two grey lines. As in the other graphs, the eye icon beneath each scale hides or shows the curve, and tapping the graph brings up the cursor displaying the values.

Appearance: a graph with two almost overlapping light blue lines, situated between two parallel grey lines.

Certification graph

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Certification tab, below the cards.

Capability

The Capability tab displays the result of the latest capability test for the axis force: the machine repeats the same force several times and verifies that the measured force is repeatable and centred on the required value.

At the top are the Minimum force, Maximum force, Cmk and Capability result cards; below, the test graph.

The tab does not appear if the calibration has been modified manually.

Capability

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Capability tab in the left-hand column.

Minimum force

The Minimum Force card shows the minimum force that the scale can exert according to the latest calibration, in kgf: below this value, the force is not guaranteed.

Appearance: a card with the title MINIMUM FORCE, a grey icon showing downward-pointing arrows on a base, and the value in white digits followed by kgf.

Minimum force

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Calibration, Certification or Capability tab, top card.

Maximum force

The Maximum Force card shows the maximum force that the axis can exert according to the latest calibration, in kgf: exceeding this value may damage the machine.

Appearance: a card with the title MAXIMUM FORCE, a grey icon showing downward-pointing arrows on a base, and the value in white digits followed by kgf.

Maximum force

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Calibration, Certification or Capability tab, second card from the top.

Cmk

The Cmk card shows the Cmk machine capability index calculated during the most recent capability test, to two decimal places. The higher the value, the more repeatable the force is and the closer it is to the required value within the tolerance. The test is passed if the Cmk is greater than 1.66. The Cmk is the smaller of the distances between the mean and the two limits (target value plus and minus the percentage tolerance), divided by three times the standard deviation of the measurements.

Appearance: card with the title Cmk and the value in white digits, without units.

Cmk

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Capability tab, third tab from the top.

Capability result

The Capability result box shows the status of the procedure:

  • OK followed by the date (day/month/year), if the test has been passed; Failed followed by the date if the test has failed;
  • In progress... whilst the procedure is running;
  • Interrupted if the last procedure was interrupted;
  • Not executed if the procedure has never been completed.

Appearance: card with the title CAPABILITY RESULT and the status shown in white text.

Capability result

Interrupted

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Header tab, Capability tab, card at the top right.

Capability chart

The graph shows the capability test, repetition by repetition. On the horizontal axis are the control points, from 1 to 50; the curves are:

  • Force setpoint: the required force, which is the same at all points, in kilogram-force (kgf);
  • Force (calibration cell): the force measured by the reference load cell at each repetition, in kgf;
  • two grey lines without a scale, the Upper limit and the Lower limit: the setpoint plus and minus the tolerance in per cent.

As in the other graphs, the eye icon beneath each scale hides or shows the curve, and tapping the graph brings up the cursor displaying the values.

Appearance: a graph with a light blue horizontal line (the setpoint), the measured curve in light blue, and two horizontal grey lines above and below.

Capability graph

Position: Machine Diagnostics > Calibrations and Certifications page, Table or Head tab, Capability tab, below the cards.

Planarity

1.4.14

The Planarity tab displays the measurements taken to check the planarity of the table and, on IR and HP machines, of the upper and lower mirrors (Table, Upper Mirror, Lower Mirror tabs in the left-hand column).

The measurements are taken by a CEMAS Elettra technician using a dial gauge, relative to the unit head, following any necessary adjustment. The top view drawing shows the deviation of the four corners in millimetres (mm), to three decimal places: the front right-hand corner, marked with a crosshair, is the reference point. The values are within specification if they fall within ± 0.05 mm of the reference point.

Above the diagram, the result and date of the last measurement are indicated (OK - followed by the date) or Not carried out.

Appearance: a grey drawing of the table viewed from above, with the operator at the bottom; three grey fields with the values next to the corners and the reference point value at the bottom right.

Planarity

Position: Machine Diagnostics > Calibrations and Certifications page, Planarity tab.

Laser sources

The Laser Sources tab displays the results of the calibration and power certification for each enabled laser source. On the left is a column of numbered tabs, one per source; for each source, a second column of tabs allows you to select either Calibration or Certification.

The procedures measure the output power using a power meter and are carried out by CEMAS or authorised technicians; the results can only be viewed here.

Availability: on laser machines only. Machine option: only enabled laser sources are displayed, up to the number specified by the Rack type, an option configured by CEMAS.

Appearance: a tab labelled Laser sources at the top; two columns of grey tabs on the left, the first of which is numbered.

Laser sources

Position: Machine Diagnostics > Calibrations and Certifications page, topmost tab.

Calibration – Laser source

The Calibration tab for a power source shows the result of the last calibration of the power: the calibration establishes a relationship between the power requested from the source, as a percentage, and the actual power measured by the power meter, in watts (W).

At the top are the Maximum laser source power and Calibration result cards; below, the calibration graph. If the calibration has been edited manually, the message Manually edited calibration appears.

Availability: on laser machines only.

Calibration – Laser source

Position: Machine Diagnostics > Calibrations and Certifications page, Laser sources tab, numbered source tab, Calibration tab.

Maximum source power

The Maximum Source Power card shows the maximum power that each source can emit, in watts (W), without decimals. It is the reference value for power percentages and is set by CEMAS.

Appearance: a card with the title MAXIMUM SOURCE POWER, the grey laser icon and the value in white digits followed by W.

Maximum source power

Position: Machine Diagnostics > Calibrations and Certifications page, Laser Sources tab, numbered laser source tab, Calibration or Certification tab, top card.

Calibration chart – Laser source

The calibration graph shows, for each measured point, the actual power emitted by the source, in watts (W), as a function of the required power, expressed as a percentage (horizontal axis Actual power (%), from 5 to 100). A smooth, rising curve indicates that the source is in good condition.

Appearance: line graph on a dark background, with a grid and a coloured power curve.

Calibration graph – Laser source

Position: Machine Diagnostics > Calibrations and Certifications page, Laser Sources tab, numbered laser source tab, Calibration tab, below the cards.

Certification – Laser source

The Certification tab for a source displays the result of the most recent power certification: the certification verifies, at several checkpoints, that the power measured by the power meter falls within the tolerance range relative to the required value.

At the top are the Maximum source power and Certification result cards; below, the certification graph.

Availability: on laser machines only.

Certification – Laser source

Position: Machine Diagnostics > Calibrations and Certifications page, Laser Sources tab, numbered laser source tab, Certification tab.

Maximum source power

The Maximum Source Power card shows the maximum power that each source can emit, in watts (W), without decimals. It is the reference value for power percentages and is set by CEMAS.

Appearance: a card with the title MAXIMUM SOURCE POWER, the grey laser icon and the value in white digits followed by W.

Maximum source power

Position: Machine Diagnostics > Calibrations and Certifications page, Laser Sources tab, numbered laser source tab, Calibration or Certification tab, top card.

Certification chart – Laser source

The certification graph shows, for each control point (horizontal axis Control points), the required power (Setpoint), the upper and lower tolerance limits, and the power measured by the Power meter, in watts (W). The certification is passed if all measured values remain within the two limits.

Appearance: graph with four coloured lines: setpoint, upper limit, lower limit and measured value.

Certification graph – Laser source

Position: Machine Diagnostics > Calibrations and Certifications page, Laser Sources tab, source-specific tab, Certification tab, below the cards.

Transducers

The Transducers page displays the readings from the position transducers – the linear sensors that measure the position of the table (and, on IR and HP machines, the head) independently of the motors. It is used to check the positions and alignment of the axes.

The page displays:

  • the transducer diagram, showing the reading from each sensor;
  • below the diagram, the Position (or Head Position) and Table Position tabs;
  • where there are two transducers, the Head Misalignment Error and Table Misalignment Error tabs.

This is a read-only page and is always accessible, even without logging in. The transducer configuration (number of sensors, sensor types, misalignment limits) is set by CEMAS.

Availability: machine option: appears if the machine has Transducers, an option configured by CEMAS.

Transducers

Position: Machine Diagnostics > Transducers menu.

Transducer diagram

The diagram shows the transducers mounted to the left and right of the machine: each transducer is represented by a vertical grey bar, the sensor magnets are yellow rectangles, and next to each sensor is the measured dimension, in millimetres (mm), to three decimal places.

The layout depends on the transducer configuration:

  • Single sensor: one sensor per transducer, at the bottom, on the table;
  • Double sensor: two sensors on the same transducer, one at the bottom (table) and one at the top (head);
  • Dual sensor on 2 transducers: two separate transducers, one for the table and one for the head.

A transducer that is not present is shown in light grey and without dimensions.

Availability: machine option: side, number of transducers and type of configuration depend on the configuration of the Transducers, an option configured by CEMAS.

Appearance: vertical grey bars on either side with yellow rectangles and dimensions in white numerals; in the centre, two grey lines representing the table and the head.

Single sensor

Dual sensor

Dual sensor on 2 transducers

Position: Machine Diagnostics > Transducers page, large card at the top.

Position

The Position card displays the coordinate of the transducer system, in millimetres (mm), to three decimal places. Without transducers, the value is the position read by the table encoder.

The value displayed depends on the machine’s technology: see the related entries.

Appearance: card with the title on the left and the value in large white digits followed by mm.

Position

Position: Machine Diagnostics > Transducers page, row of cards below the diagram, first card on the left.

Table position

The Table Position tab shows the position of the table, as read by the transducers, relative to machine zero, in millimetres (mm), to three decimal places.

Appearance: tab with the title on the left and the value in large white digits followed by mm.

Table position

Position: Machine Diagnostics > Transducers page, card row below the diagram, below the Position card.

Head misalignment error

The Head Misalignment Error card displays the difference between the head position read by the right-hand transducer and that read by the left-hand transducer, in millimetres (mm), to three decimal places. A value other than zero indicates that the head is not parallel; if the limit set by CEMAS is exceeded, the machine signals an alarm.

Availability: machine option: appears if both the left and right transducers are present (Transducers, Left and Right), an option configured via CEMAS.

Appearance: card with the title on the left and the value in large white digits followed by mm.

Head misalignment error

Position: Machine Diagnostics > Transducers page, card row below the diagram, to the right of the Position card.

Table misalignment error

The Table Misalignment Error card displays the difference between the table height read by the right-hand transducer and that read by the left-hand transducer, in millimetres (mm), to three decimal places. A value other than zero indicates that the table is not parallel; if the limit set by CEMAS is exceeded, the machine signals an alarm.

Availability: machine option: appears if both the left and right transducers are present (Transducers, Left and Right), an option configured via CEMAS.

Appearance: card with the title on the left and the value in large white digits followed by mm.

Table misalignment error

Position: Machine Diagnostics > Transducers page, card row below the diagram, to the right of the Table Position card.

Cooling system

The Cooling System page displays the circuit diagram for the system that cools the laser head and the electric panel, showing the status of the components and the readings from the sensors. It is used to check that water and air are circulating correctly and to troubleshoot cooling alarms.

The circuit consists of:

  • Chiller: cools the water and sends it to the laser source racks and the dryer;
  • Dryer: dehumidifies the air entering the head;
  • Isolation valve: opens the water flow to the head racks;
  • temperature and dew point sensors on the outside, at the input, at the output and inside the head, and flow sensors on the racks and on the dryer.

In the diagram, the coloured lines indicate the circuits: light blue for dry air at the input to the head, yellow for hot, humid air at the output from the head, blue for cold water, and orange for hot water returning to the chiller. The legend below the diagram explains the symbols.

Each value appears only if its corresponding sensor is present in the machine’s configuration. If the cooling system is disabled, the message Cooling system disabled appears in place of the diagram.

The diagram depends on the machine model: see the related entries.

The page is always accessible, even without logging in.

Availability: only on MF240, MF480, MF960 and MF960-XT laser machines. Machine option: the diagram appears if the Cooling system is enabled, an option configured via CEMAS.

Cooling system

Position: Machine Diagnostics > Cooling system menu.

Status

1.4.14

In the legend, the Status indicator explains the meaning of the round indicators shown next to the chiller, dryer and isolation valve: green when the component is operating (or the valve is open), grey when it is stationary.

Appearance: green circular indicator light followed by the word Status.

Status

Position: Machine Diagnostics > Cooling System page, legend below the diagram, first item on the left.

Temperature in °C

1.4.14

In the legend, the thermometer symbol indicates the air temperature readings taken by the sensors, in degrees Celsius (°C). In the diagram, each temperature reading is preceded by the same symbol.

Appearance: a white thermometer icon followed by the text Temperature in °C.

Temperatures in °C

Position: Machine Diagnostics > Cooling System page, legend below the diagram, second entry.

Dew point in °C

1.4.14

In the legend, the drop symbol indicates the dew point values, in degrees Celsius (°C). The dew point is the temperature at which the air, at constant pressure, becomes saturated with water vapour: if a surface is colder than the dew point, condensation forms on it. For this reason, the air in the cylinder head must have a dew point lower than the temperature of the coolant.

Appearance: a white drop icon followed by the text Dew Point in °C.

Dew Point in °C

Position: Machine Diagnostics > Cooling System page, legend below the diagram, third entry.

Flow rate in l/min

1.4.14

In the legend, the animated arrow indicates the water flow sensors; the values are in litres per minute (l/min). In the diagram, the arrow moves when the flow exceeds the sensor’s minimum alarm threshold and remains still when the flow is insufficient.

Appearance: animated arrow followed by the text Flow in l/min.

Flow in l/min

Position: Machine Diagnostics > Cooling System page, legend below the diagram, last item on the right.

Chiller

The Chiller indicator light shows whether the chiller is running. The chiller cools the water in the circuit, which is supplied to the laser source racks, the dryer and, on the MF240 and MF480 models, to the electric panel cooling system. It starts up when the welding machine is switched on.

Appearance: a round green indicator light when the chiller is running, grey when it is off, above the chiller diagram.

Chiller

Position: Machine Diagnostics > Cooling System page, system diagram, top left.

Chiller

ICON ACTION
Chiller The chiller cools the water that is then distributed to the racks, the air/H2O exchanger and the dryer. When active, the LED lights up green.
Temperature Actual external temperature (expressed in °C) and dew point temperature (expressed in °C).

Outdoor temperatures

The figures in the top left-hand corner show the temperature and dew point of the air in the room where the machine is located, in degrees Celsius (°C), to one decimal place.

Availability: Machine option: appears if the sensor is included in the Cooling System configuration, an option configured by CEMAS.

Appearance: two values in white digits, the first preceded by a thermometer symbol, the second by a droplet symbol.

External temperatures

Position: Machine Diagnostics > Cooling System page, system diagram, top left-hand corner.

Dryer

The Dryer indicator light shows whether the dryer is in operation. The dryer dehumidifies the air entering the head and recirculates it at the output to dehumidify it again; it is cooled by water from the chiller. It starts up when the welding machine is switched on.

Appearance: a round green indicator light when the dryer is running, grey when it is off, above the diagram of the dryer.

Dryer

Position: Machine Diagnostics > Cooling System page, system diagram, at the top, to the right of the chiller.

Dryer

ICON ACTION
Dryer The dryer allows the air entering the welding machine head to be dehumidified. When active, the LED lights up green.

Shut-off valve

The Shut-off valve indicator light shows whether the valve supplying cold water to the head racks is open. The valve opens when the water has reached the correct temperature; whilst it is closed, water does not circulate through the racks. If the machine is fitted with an open-valve sensor, the indicator light follows the sensor; otherwise, it follows the opening command.

Availability: machine option: appears if the isolation valve is configured in the Cooling System, an option configured by CEMAS.

Appearance: round green indicator light when the valve is open, grey when it is closed.

Shut-off valve

Position: Machine Diagnostics > Cooling System page, system diagram, at the top of the water line leading to the head.

Shut-off valve

ICON ACTION
Valve The shut-off valve allows water to flow to the welding machine head racks when the correct water temperature is reached. When active, the LED lights up green.

Fan

ICON ACTION
Fan If a fan is present, its symbol appears inside the head. The fan is used to promote proper air flow inside the welding machine head.

Inlet temperature at the head

The values at the head inlet show the temperature and dew point of the dry air entering the head, in degrees Celsius (°C). A high dew point indicates that the dryer is not dehumidifying sufficiently.

Availability: Machine option: appears if the sensor is present in the Cooling System configuration, an option configured by CEMAS.

Appearance: two values in white digits, the first preceded by a thermometer symbol, the second by a drop symbol.

Header inlet temperature

Position: Machine Diagnostics > Cooling System page, system diagram, on the light blue line to the left of the header.

Head temperatures

ICON ACTION
Temperature Actual temperature (expressed in °C) and Dew Point temperature (expressed in °C) at the head inlet.
Temperatures Actual temperature (expressed in °C) and dew point temperature (expressed in °C) at the top of the head.
Temperatures Actual temperature (expressed in °C) and dew point temperature (expressed in °C) at the bottom of the head.
Temperatures Actual temperature (expressed in °C) and dew point temperature (expressed in °C) at head outlet.

Temperature at the top

The values at the top of the head show the temperature and dew point of the air inside the head, at the top, in degrees Celsius (°C).

Availability: Machine option: appears if the sensor is included in the Cooling system configuration, an option configured by CEMAS.

Appearance: two values in white digits, the first preceded by a thermometer symbol, the second by a droplet symbol.

Upper head temperature

Position: Machine Diagnostics > Cooling System page, system diagram, inside the head, at the top.

Temperature at the bottom

The values at the bottom of the head show the temperature and dew point of the air inside the head, at the bottom, in degrees Celsius (°C).

Availability: Machine option: appears if the sensor is included in the Cooling system configuration, an option configured by CEMAS.

Appearance: two values in white digits, the first preceded by a thermometer symbol, the second by a droplet symbol.

Lower head temperature

Position: Machine Diagnostics > Cooling System page, system diagram, inside the head, at the bottom.

Header output temperature

The values at the head output show the temperature and dew point of the air leaving the head and returning to the dryer, in degrees Celsius (°C).

Availability: Machine option: appears if the sensor is included in the Cooling system configuration, an option configured by CEMAS.

Appearance: two values in white digits, the first preceded by a thermometer symbol, the second by a drop symbol.

Head output temperature

Position: Machine Diagnostics > Cooling System page, system diagram, on the yellow line to the right of the head.

Rack flow

Beneath each rack, the value shows the flow rate of the cooling water passing through the rack, in litres per minute (l/min), to one decimal place. Next to it, the arrow moves when the flow rate exceeds the sensor’s minimum alarm threshold; a stationary arrow indicates insufficient flow, which triggers the flow alarm after the set delay.

There are three racks on the MF240 and MF480 models, and six on the MF960 and MF960-XT models.

Availability: Machine option: appears if the sensor is included in the Cooling System configuration, an option configured by CEMAS.

Appearance: animated vertical arrow and value in white digits, without a symbol.

Rack flow

Position: Machine Diagnostics > Cooling System page, system diagram, below the head racks, one per rack.

Flows

ICON ACTION
Flow Flow rate (expressed in l/min) of hot water leaving rack 1.
Flow Flow rate (expressed in l/min) of hot water leaving rack 2.
Flow Flow rate (expressed in l/min) of hot water at the outlet of rack 3.
Flow Flow rate (expressed in l/min) of hot water at the outlet of rack 4.
Flow Flow rate (expressed in l/min) of hot water leaving rack 5.
Flow Flow rate (expressed in l/min) of hot water leaving rack 6.
Flow Flow rate (expressed in l/min) of hot water leaving the dryer, flow 1.
Flow Flow rate (expressed in l/min) of hot water leaving the dryer, flow 2.

Dryer flow

The readings on the dryer circuit show the dryer’s cooling water flow rate, in litres per minute (l/min); there may be two sensors, one per circuit. The arrow next to the reading flashes when the flow rate exceeds the minimum alarm threshold.

Availability: Machine option: appears if the sensor is included in the Cooling System configuration, an option configured by CEMAS.

Appearance: animated horizontal arrow and value displayed in white digits.

Dryer flow

Position: Machine Diagnostics > Cooling System page, system diagram, at the bottom, on the dryer water line.

Control panel cooling flow

This value indicates the flow rate of the water used to cool the electric panel, in litres per minute (l/min). The arrow next to it flashes when the flow rate exceeds the minimum alarm threshold.

Availability: only on MF240 and MF480 machines. Machine option: appears if the sensor is included in the Cooling System configuration, an option configured by CEMAS.

Appearance: animated arrow pointing upwards and value displayed in white digits.

Control panel cooling flow

Position: Machine Diagnostics > Cooling System page, system diagram, bottom right.

Cooling system – MF240 and MF480

On the MF240 and MF480 machines, the diagram shows three racks, each with its own flow sensor, and the electric panel cooling circuit with the value Electric panel cooling flow. The fan is not shown in the diagram.

Cooling system – MF240 and MF480

Position: Machine diagnostics > Cooling system page, system diagram.

Laser system

The Laser System page displays the status of the laser sources installed in the head and allows them to be controlled manually, along with the rack shutters. It is used for source diagnostics and maintenance checks.

The page is divided into tabs:

  • Laser Sources: a tab for each source, displaying operating parameters and the manual emission control;
  • Racks: controls for opening and closing the fibre and lens shutters on each rack.

The number of sources and racks depends on the machine’s rack type: 4 racks with 3 sources each (12 sources), 3 racks with 8 sources each (24 sources) or 6 racks with 16 sources each (96 sources).

The commands require access to the page; without logging in, the values can only be viewed.

Warning The manual emission command actually switches on the laser source: before using it, check that the work area is clear and that the safety guards are closed.

Availability: on laser machines only.

Laser system

Position: Machine diagnostics > Laser system menu.

Laser sources

The Laser Sources tab has a column of numbered tabs on the left, one for each laser source in the machine (12, 24 or 96 depending on the Rack Type). Each tab displays the Laser Source card with the operating values and, below that, the source’s manual controls.

If a source is not present in the configuration, the message Source not present appears at the top and the controls are disabled.

Availability: machine option: appears if the Rack type includes at least one laser source; this option is configured by CEMAS.

Appearance: tab with the text Laser sources at the top; a column of grey, numbered tabs on the left, with the selected tab highlighted in white.

Laser sources

Source not present

Position: Machine Diagnostics > Laser System page, first tab at the top.

Laser source

The Laser Source tab, followed by a number, displays the operating values of the selected source in two columns:

  • on the left: Powered, Power in watts and as a percentage, Photodiode 1 and Photodiode 2;
  • on the right: Emission, Diode temperature and the values for the driver powering the source: Driver input voltage, Driver output voltage, Driver output current and Driver temperature.

The values are updated in real time.

Appearance: a card with a grey laser icon and the title LASER SOURCE followed by a number; a row with the name on the left, the value in white digits in the centre and a grey icon on the right.

Laser source

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered laser source tab, top card.

Powered

The Power indicator shows whether the light source is powered. The indicator flashes whilst the light source is switching on.

Appearance: a round green indicator that is lit when the light source is powered, flashes whilst switching on, and is grey when switched off.

Powered

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered tab for the source, Laser Source card, first row on the left.

Power

The Power row, with the unit W, shows the power currently being emitted by the source, in watts (W), to one decimal place. When the source is not emitting, the value is zero.

Appearance: a row with the name on the left, the value in white digits in the centre and a grey icon on the right; the value is followed by W.

Power

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered laser source tab, Laser Source card, left-hand column, second row.

Power %

The Power row, with the unit %, shows the power currently being emitted by the source as a percentage of its maximum power, to one decimal place.

Appearance: a row with the name on the left, the value in white digits in the centre and a grey icon on the right; the value is followed by %.

Power %

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered laser source tab, Laser Source card, left-hand column, third row.

Photodiode 1

The Photodiode 1 row shows the level read by the first photodiode of the source, the sensor that detects the emitted light. The value is an integer without units.

Appearance: row with the name on the left, the value in white digits in the centre and a grey icon on the right; value without units.

Photodiode 1

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered source tab, Laser Source card, left-hand column, fourth row.

Photodiode 2

The Photodiode 2 row shows the level read by the source’s second photodiode. The value is an integer without units.

Appearance: row with the name on the left, the value in white digits in the centre and a grey icon on the right; value without units.

Photodiode 2

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered source tab, Laser Source card, left-hand column, last row.

Issue

The Emission indicator shows whether the laser source is emitting the laser, either in cycle mode or when the manual On command is active.

Appearance: a round green light is on during emission; otherwise, it is grey.

Emission

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered laser source tab, Laser Source card, first row on the right.

Diode temperature

The Diode temperature row displays the temperature of the laser source’s diode, in degrees Celsius (°C), to one decimal place. A high temperature generally indicates a rack cooling problem: check the Machine diagnostics > Cooling system page.

Appearance: a row with the name on the left, the value in white digits in the centre and a grey icon on the right; the value is followed by °C and a thermometer icon.

Diode Temperature

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered laser source tab, Laser Source card, right-hand column, second row.

Driver input voltage

The Driver input voltage row displays the supply voltage at the input to the light source driver, in volts (V), to one decimal place.

Appearance: a row with the name on the left, the value in white digits in the centre and a grey icon on the right; the value is followed by V.

Driver input voltage

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered laser source tab, Laser Source card, right-hand column, third row.

Driver output voltage

The Driver output voltage row shows the voltage that the driver applies to the laser diode, in volts (V), to one decimal place.

Appearance: a row with the name on the left, the value in white digits in the centre and a grey icon on the right; the value is followed by V.

Driver output voltage

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered source tab, Laser Source card, right-hand column, fourth row.

Driver output current

The Driver output current row shows the current supplied by the driver to the laser diode, in amperes (A), to one decimal place. It increases as the power demanded from the laser source increases.

Appearance: a row with the name on the left, the value in white digits in the centre and a grey icon on the right; the value is followed by A.

Driver output current

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered laser source tab, Laser Source card, right-hand column, fifth row.

Driver temperature

The Driver temperature row displays the temperature of the light source driver, in degrees Celsius (°C), to one decimal place.

Appearance: a row with the name on the left, the value in white digits in the centre and a grey icon on the right; the value is followed by °C and a thermometer icon.

Driver temperature

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered laser source tab, Laser Source card, right-hand column, last row.

Manual source control

The tab below the values allows manual control of the source’s output:

  • the field, expressed as a percentage (%), with one decimal place, sets the manual output power;
  • the On button switches the output on whilst it is held down and switches it off when released.

The field and button are disabled if the source is not present or is in alarm mode.

Warning The **On** button actually switches on the laser source: use it only when the work area is clear and the safety guards are closed.

Appearance: white field displaying the value followed by % and a green button labelled ON; the button has a green halo whilst the laser is emitting, and a red halo when the laser source is in alarm.

Manual laser source control

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered laser source tab, card below the Laser Source card.

On

The On button activates manual emission from the source at the power level set in the adjacent field, but only whilst the button is held down. It is disabled if the source is not present or is in alarm mode.

Appearance: green button labelled ON, with a green halo whilst the source is emitting and a red halo when the source is in alarm.

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered laser source tab, command card, to the right of the power field.

On

The On button activates manual emission from the source at the power level set in the adjacent field, but only whilst the button is held down. It is disabled if the source is not present or is in alarm mode.

Appearance: green button labelled ON, with a green halo whilst the source is emitting and a red halo when the source is in alarm.

Position: Machine Diagnostics > Laser System page, Laser Sources tab, numbered laser source tab, command card, to the right of the power field.

Racks

The Racks tab allows you to manually control the shutters on the racks – the drawers containing the laser sources. It is divided into two columns:

  • Fibre shutters: the shutters for the optical fibres;
  • Lens shutters: the shutters for the lenses.

Each column lists the configured shutters, one per rack; if there are none, the message No shutters available appears.

Appearance: a tab labelled Racks at the top; two columns with the grey icon and the title in capital letters.

Racks

Position: Machine Diagnostics > Laser System page, Racks tab at the top.

Fibre shutters

The Fibre Shutter column lists the fibre shutters, one for each rack on which they are configured, with the name Fibre Shutter followed by the rack number.

Availability: machine option: each row appears if the rack’s fibre shutter is configured; this option is configured via CEMAS.

Appearance: column with a grey icon of a beam of fibres and the heading FIBRE SHUTTER.

Fibre shutter

Position: Machine Diagnostics > Laser System page, Racks tab, left-hand column.

Definition of fibre shutter

Each row has Close and Open buttons, which close or open the fibre shutter on the rack with a single tap. The buttons are disabled if the rack is not present or if the shutter is in alarm mode.

Appearance: a rounded black row with the name in white and two green buttons labelled CLOSE and OPEN; the button has a green halo when the shutter has reached the corresponding position, and both have a red halo when the shutter is in alarm mode.

Shutter fibre definition

Position: Machine Diagnostics > Laser System page, Racks tab, Shutter fibre column.

Lens shutters

The Lens Shutters column lists the lens shutters, one for each rack on which they are configured, with the name Lens Shutters followed by the rack number.

Availability: machine option: each row appears if the lens shutter for the rack is configured; this option is configured via CEMAS.

Appearance: column featuring a grey icon of a beam of fibres and the heading LENS SHUTTER.

Lens shutter

Position: Machine Diagnostics > Laser System page, Racks tab, right-hand column.

Definition of lens shutters

Each row has Close and Open buttons, which close or open the rack’s lens shutter at the touch of a button. The buttons are disabled if the rack is not present or if the shutter is in alarm mode.

Appearance: similar to the fibre shutter rows: two green buttons, CLOSE and OPEN, with a green highlight when the position is reached and a red highlight when in alarm.

Lens shutter definition

Position: Machine Diagnostics > Laser System page, Racks tab, Lens Shutters column.

Smart accessory

The Smart accessory menu item opens the web interface for the smart accessory connected to the machine in a full-screen window: the smart accessory is an external device that exchanges signals with the welding machine and has its own configuration and diagnostics page.

When opened, the window displays Connecting to the device... until the smart accessory page has loaded. If the smart accessory is not connected, the message Ooops... The device is disconnected!!!: check the device’s power supply and network connection.

The signals exchanged with the smart accessory can be viewed on the Machine Diagnostics > PLC page, under the Smart accessory tab.

Availability: machine option: appears if the Smart accessory is present and has a Web server, an option configured by CEMAS. The page is restricted to users authorised to manage the machine and to CEMAS technicians.

Appearance: in the menu, the Smart accessory item is displayed with an icon of a window featuring an arrow, indicating that it opens in a separate window.

Position: Machine Diagnostics > Smart accessory menu.